• Title/Summary/Keyword: absorption coefficient (a)

Search Result 845, Processing Time 0.03 seconds

Manufacturing Characteristics of Cement-Bonded Wood Composite Board as Sound Absorption Type-Noise Barrier

  • Suh, Jin-Suk;Kang, Eun-Chang;Park, Jong-Young
    • Journal of the Korean Wood Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.50-56
    • /
    • 2004
  • This study was conducted to investigate the performance of sound absorption type-noise barriers manufactured with a combination of wood particles used for particleboard, recycled waste newspaper, and cement. An average density of wood-combined cement board was in the range from 0.83 to 0.96 g/cm3, showing relatively low-density board. Regardless of types of cement bonded board or wooden board, the board with concave holes(凹)-formed surfaces showed greater sound absorption coefficient compared to those of flat surface boards. The board density was not related with those coefficients. Accordingly, it was concluded that concave or deep corrugated surface structure has played an important role in sound absorption for the application of sound absorption type-noise barrier.

Design of the Acoustical Diffuser using the ISO method (ISO 방법론을 이용한 음향 확산체 설계)

  • Seo, Choon-Ki;Lee, Pyoung-Jik;Jeong, Jeong-Ho;Jin, Yong-Jeon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.29-32
    • /
    • 2008
  • In this study, acoustic diffusers were designed as to the ISO method, which measured the random-incidence scattering coefficient of surfaces in a diffuse field. The diffusers which were made of GFRG (Glass Fiber Reinforced Gypsum), consisted of the cubes with different height and width. The height was from 50 to 250 mm and the maximum height was at the center of the diffusers to provide the early reflections. The surfaces were irregularly designed in order to add the lateral reflections. The scattering coefficient of the diffusers was measured in a 1;10 reverberation chamber, but the absorption coefficient was measured in a real scale reverberation chamber. The result of the scattering coefficient was compared to the hemisphere diffusers and the absorption coefficient was compared to ISO 354 data. To validate the measurement results, the scattering coefficient of the diffusers will be measured in a real scale reverberation chamber.

  • PDF

An Experimental Study on Acoustic Absorption in a Model Chamber with a Half-Wave Resonator (반파장 공명기를 장착한 모형연소실의 흡음특성에 대한 실험적 연구)

  • Sohn, Chae-Hoon;Park, Ju-Hyun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.3
    • /
    • pp.34-40
    • /
    • 2008
  • Acoustic design parameters of a half-wave resonator are studied experimentally for acoustic stability in a model chamber. According to the standard acoustic-test procedures, acoustic-pressure signals are measured. Quantitative acoustic properties of damping factor and sound absorption coefficient are evaluated and thereby, the acoustic-damping capacity of the resonator is examined. The diameter and the number of a half-wave resonator, its distribution, and the diameter of an enclosure are selected as the design parameters for optimal tuning of the resonator. Aroustic-damping capacity of the resonator increases with its diameter. When the open-area ratio of the resonator exceeds the optimum value, over-damping appears, leading to the decrease in the peak absorption coefficient and the broadening of absorption bandwidth. As the resonator diameter increases, optimum open-area ratio decreases.

Absorption of d-Limonene in Orange Juice into a Laminated Food Package Studied with a Solid Phase Micro-extraction Method

  • Lee, Hahn-Bit;Yang, Hee-Jae;Min, Sea-C.
    • Food Engineering Progress
    • /
    • v.14 no.4
    • /
    • pp.354-358
    • /
    • 2010
  • The methods for determining the diffusion parameters for the diffusion of d-limonene, a major volatile compound of orange juice, through a multi-layered food packaging material and predicting its absorption into the packaging material have been investigated. The packaging material used was the 1.5-mm thick multi-layered packaging material composed of high impact polystyrene (HIPS), polyvinylidene chloride (PVDC), and low density polyethylene (LDPE). Orange juice was placed in a cell where volatiles were absorbed in the sample package and kept at $23{\pm}2^{\circ}C$ for 72 hr. The d-limonene absorbed in a 1.5-mm thick multi-layered food packaging material was analyzed by a solid phase micro-extraction (SPME). The absorption parameters for the absorption of d-limonene in the packaging material were determined and absorption of d-limonene into the packaging material was predicted using absorption storage data. The SPME desorption at $60^{\circ}C$ for 1 hr resulted in the most sensitive and reproducible results. The diffusion coefficients of d-limonene in the packaging material and the partition coefficient at $23{\pm}2^{\circ}C$ were approximately $1-2{\times}10^{12}m^2$/s and 0.03, respectively. The absorption profile no earlier than 30 hr was fit well by a model derived from the Fick's law.

A New Method for Determining the Absorption Coefficient of Oxy- and Deoxyhemoglobin by use of a Thin-fi im Optical Waveguide Sensor (박막광도파로 센서를 이용한 산화 및 환원 혈색소의 새로운 흡광계수 측정법)

  • 강신원
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.387-394
    • /
    • 1995
  • A simple method for determining the absorption coefficient of oxyhemoglobin and deoxyhemoglobin in human blood is proposed as an application of the complex propagation constant of a guided wave in a thin-film optical waveguide. A serial multichannel sample chamber is constructed on the waveguide to vary the interaction length between the evanescent field and the sample, and the dependence of the sensor response on the interaction length is investigated for the various concentration of two hemoglobins. The sensor response is linearly proportional to the interaction length and the concentration of two hemoglobins. The attenuation constant due to the evanescent field absorption between the samples is experimentally obtained with the designed sensor, and then the absorption coefficient is determined by the proposed method. The absorption coefficients determined by the proposed method fairly well coincided with those obtained by the conventional transmission measurement.

  • PDF

Investigation on Femtosecond Laser Processing of Polymeric Thin Films (펨토초 레이저를 이용한 폴리머 박막 재료 초미세 공정에 관한 연구)

  • Jeoung S.C.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.669-670
    • /
    • 2006
  • Two-photon absorption coefficient of a series of dyes in polymer thin films was determined by measuring the femtosecond laser ablation threshold. The threshold value of polymeric thin films decreased gradually when the dopant increased. The two-photon absorption coefficient of the dye molecules dispersed in the polymer film was estimated by using the theoretical relationship between the ablation threshold of the blended polymeric thin films and the dye concentration. The relative values of two-photon absorption cross-section are in good agreement with those measured in solution. On the other hand, the absolute values are smaller than the latter.

  • PDF

A Study on Characteristic of Photoelectric Absorption with Diagnostic X-ray Contrast Media (X-선 진단용 조영제의 광전흡수 특성에 관한 연구)

  • Kim, Young-Keun;Han, Jae-Jin;Lee, Kyung-Sup
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.46-51
    • /
    • 1998
  • The absorption coefficient of contrast media was measured in region of diagnostic radiology. Relative values of absorption coefficient was found the largest peak in the range of $60{\sim}70\;kVp$ for barium sulfate and 60 kVp for iodine. Increasing the thickness of contrast media and patient, the values of absorption coefficient was rising. In the Radiograph, desired $70{\sim}80\;kVp$ in the gastrointestinal digestion tract with barium sulfate and the vascular tract is before and behind 65 kVp of exposure.

  • PDF

An Experimental Study on the Grazing Incidence Sound Absorption of a Perforated Panel System (다공판 시스템의 접선입사 흡음성능에 관한 실험적 연구)

  • Je, Hyun-Su;Yang, Soo-Young;Hong, Byung-Kuk;Song, Hwa-Young;Lee, Dong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1052-1055
    • /
    • 2004
  • This paper introduces an experimental study on the grazing incidence sound absorptions for duct silencers filed with a glass wool and consisted of a perforated panel. The experimental results are discussed in comparison with the normal incidence sound absorption. And also the transmission loss for duct silencers are measured and compared with the sound absorption performances. From the experimental results, it is shown that the resonance frequency bandwidth on the transmission loss and sound absorption coefficient for duct silencers has a good agreement.

  • PDF

A Numerical Study on Heat and Mass Transfer in a Falling Film of Vertical Plate Absorber Cooled by Air (공랭형 수직평판 흡수기 액막에서의 열 및 물질전달에 관한 수치적 연구)

  • 김선창;오명도;이재헌
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.4
    • /
    • pp.1071-1082
    • /
    • 1995
  • Numerical analyses have been performed to obtain the absorption heat and mass transfer coefficients and the absorption mass flux from a falling film of the LiBr aqueous solution which is cooled by cooling air. Heat flux at the wall is specified in terms of the heat transfer coefficient of cooling air and the cooling air temperature. Effects of operating conditions, such as the heat transfer coefficient, the cooling air temperature, the system pressure and the solution inlet concentration have been investigated in view of the local absorption mass flux and the total mass transfer rate. Effects of film thickness and film Reynolds number on the heat and mass transfer coefficients have been also estimated. Analyses for the constant wall temperature condition have been also carried out to examine the reliability of present numerical method by comparing with previous investigations.

Performance Characteristic of the compression-absorption hybrid cycles (흡수압축 하이브리드 사이클의 성능특성)

  • Kim Jae-Man;Kwon Oh-Kyung;Moon Choon-Geun;Seol Won-Sil;Yoon Jung-In
    • 한국가스학회:학술대회논문집
    • /
    • 1998.09a
    • /
    • pp.255-260
    • /
    • 1998
  • This study describes the results of Coefficient Of Performance(COP) analysis by cycle simulation for two types of absorption-compression hybride cycle using the water/Lithium Bromide solution pair, These types are basic hybride systems introducing a mechanical compression process into the refrigerant vapor phase of the single effect absorption cycle. In absorption-compression hybrid cycles, coefficient of performance is improved compared with absorption cycle. Hybride cycle Type ll is considered as a key technology to support energy utilization system, given its capability of utilizing waste heat to drive system with a high level of efficiency.

  • PDF