• 제목/요약/키워드: abrasion

검색결과 1,209건 처리시간 0.024초

칼날형 마모시험기를 이용한 SBR 배합고무의 마모속도 결정 (Determination of Abrasion Rate of SBR Rubber Compounds using a Knife-blade Abrader)

  • 김동희;강신영
    • Elastomers and Composites
    • /
    • 제49권2호
    • /
    • pp.149-154
    • /
    • 2014
  • 실리카와 카본블랙을 함유한 SBR 배합고무를 대상으로 마찰 및 마모거동을 조사하였다. 인열에너지 이론을 배경으로 설계된 칼날형 마모시험기를 이용하였으며 마찰일의 크기가 SBR 배합고무의 마모속도에 미치는 영향을 평가하였다. 마찰일이 증가할수록 마모속도가 증가하는 power law관계를 확인하였다. 칼날형 마모시험기를 통해 기존의 간헐적 마모손실무게 측정 대신 연속적 마모이동거리 측정이 가능했으며 보다 정확한 마모속도를 결정할 수 있었다.

SCP-1재료 적용을 위한 초경재료 펀치의 내마모성에 대한 연구 (A study on the abrasion resistance of punching carbide material of die for the application of SCP-1 material)

  • 김승수;이민;이춘규
    • Design & Manufacturing
    • /
    • 제13권2호
    • /
    • pp.44-48
    • /
    • 2019
  • Motor core products are used as materials for electrical steel sheets and cold-rolled steel sheets according to the performance of motors. The cemented carbide material of the mold punch applied to the motor core material causes many troubles due to abrasion and burr problem. The selection of these materials has a great effect on the production life, mass production, product quality as well as mold life. The cemented carbide applied to the products of the motor core is recognized as a very important part. In this study, cold rolled steel sheet was applied to motor core SCP-1 steel 1.0mm, and The effects of abrasion and punching oil on the shear process were investigated for the selection of cemented carbide. Experiments were conducted to select and apply cemented carbide only for the motor core punch optimized for cold rolled steel. The results showed that the cemented carbide material of $CDK3^{***}$ produced the least wear and burrs.

아라미드 섬유강화 및 고무조성에 따른 콘크리트 도킹호스의 파열압력과 내마모도 특성 (Characteristics of Burst Pressure and Abrasion Resistance of Concrete Hose with Aramid Fiber Reinforcement and Rubber Composition)

  • 김용환;이승환;성일경;이여울;강명창
    • 한국기계가공학회지
    • /
    • 제17권6호
    • /
    • pp.105-110
    • /
    • 2018
  • A concrete docking hose of pump car's boom pipe line have been used in many construction sites. They are long structures with continuous cornering, similar to a trunk of the elephant, characterized by a very high pressure resistance of 20MPa. They need flexible materials and structure in order to move the hose smoothy. But commercial concrete hose is hard to handle and heavy owing to adaption of steel reinforcement. In this study, it is tried an experimental approach to the characteristic of inner rubber layer and abrasion resistance. Also, we are investigated the bursting pressure according to the reinforcement of the hose and propose the usefulness of the hose reinforced with high strengthened aramid fiber.

Characterization of Cr-P-C/MoS2 composite plating electro-deposited from trivalent chromium

  • Park, Jong-Kyu;Seo, Sun-Kyo;Byoun, Young-Min;Lee, Chi-Hwan
    • Journal of Ceramic Processing Research
    • /
    • 제19권6호
    • /
    • pp.445-449
    • /
    • 2018
  • Chromium plating is a common surface treatment technique extensively applied in industry due its excellent properties which include substantial hardness, abrasion resistance, corrosion resistance, surface color, and luster. In this study, the effect of $MoS_2$ particles of the composite coating was investigated. To improve the lubrication of mold, $Cr-P-C/MoS_2$ composite plating was studied by varying the $MoS_2$ content. The current efficiency of the composite plating incorporated $MoS_2$ particles was increased at $MoS_2$ contents of 0.5 and 1.0 g/l due to the incorporation of fine particles. On the other hand, when the content of $MoS_2$ is 1.0 g/l or more, the current efficiency is lowered due to an increase in impact on the cathode surface. In order to evaluate the mechanical properties of Scratch test were conducted. Scratch test confirmed the lubricity and abrasion resistance characteristics revealed that the composite plating with added $MoS_2$ had relatively low surface roughness and uniform surface modification to improve its properties.

Effect of granite fines on mechanical and microstructure properties of concrete

  • Jain, Kishan Lal;Sancheti, Gaurav
    • Advances in concrete construction
    • /
    • 제13권6호
    • /
    • pp.461-470
    • /
    • 2022
  • Solid waste management is of great concern in today's world. An enormous amount of waste is generated from various industrial activities. Concrete production utilizing some of the potential waste materials will add to the benefit of society. These benefits will include reduction of landfill burden, improved air quality, riverbed protection due to excessive sand excavation, economical concrete production and much more. This study aims to utilize waste granite powder (GP) originating from granite industries as a sand replacement in concrete. Fine GP was collected in the form of slurry from different granite cutting industries. In this study, GP was added in an interval of ten percent as 10%, 20%, 30%, 40% and 50% by weight of sand in concrete. Mechanical assets; compressive strength, flexural strength and splitting tensile strength were prominent for control and blended mixes. Modulus of elasticity (MoE) and abrasion tests were also performed on control and blended specimens of concrete. To provide a comprehensive clarification for enhanced performance of GP prepared concrete samples, scanning electron microscopy (SEM) and X-ray diffraction (XRD) were performed. Results indicate that 30% replacement of sand by weight with GP enhances the mechanical assets of concrete and even the results obtained for 50% replacement are also acceptable. Comprehensive analysis through SEM and XRD for 30% replacement was better than control one. The performance of GP added to concrete in terms of abrasion and modulus of elasticity was far better than the control mix. A significant outcome shows the appropriateness of granite fines to produce sustainable and environmentally friendly concrete.

강한 교합력과 과도한 마모를 보이는 환자의 전악수복 증례 (Case report: Full mouth rehabilitation for patient with heavy occlusal force and excessive abrasion)

  • 박지희;방몽숙;양홍서;박상원;윤귀덕;임현필
    • 대한치과보철학회지
    • /
    • 제51권2호
    • /
    • pp.119-124
    • /
    • 2013
  • 과도한 마모를 보이는 환자는 광범위한 수복 치료를 필요로 하는 경우가 많다. 마모의 원인은 주로 교모에 의해 발생하나 이외에도 여러 가지 유발 요인이 있으며 치료 계획은 이러한 마모의 양상과 병인 분석에서 가장 먼저 시작되어야 한다. 발달된 저작근과 치조돌기, 높은 교합력을 보이며 수축 상태와 안정 상태의 근육길이 차이가 적어 악간 간격이 많지 않은 환자는 수직 고경 상실에 대한 평가와 수복물의 설계가 더욱 신중하게 이루어져야 한다. 치아 길이의 감소는 그에 상응하는 치조골 높이 신장에 의해 보상될 수 있으며 수직고경의 항상성이 유지되는 것이므로, 이 경우 수직고경의 섣부른 증가는 근피로감, 치아의 압하 및 통증, 보철물의 파절등을 초래할 수 있다. 본증례의 환자는 다수 치아의 마모와 이 악물기 습관이 관찰된 환자로, 수직고경의 증가를 동반하여 상악 무치악 부위는 아말감을 삽입한 가철성 국소의치, 상하악 유치악 부위는 고정성 보철물로 수복을 하였으며, 이에 기능적인 면과 심미적인 면에서 만족스러운 결과를 얻었기에 치험례를 보고하고자 한다.

생불활성 질화물 이온도금된 티타늄 임프란트의 표면특성 및 생체적합성 (Surface characteristics and biocompatibility of bioinert nitrides ion plated titanium implant)

  • 장갑성;김흥중;박주철;김병옥;한경윤
    • Journal of Periodontal and Implant Science
    • /
    • 제29권1호
    • /
    • pp.209-231
    • /
    • 1999
  • Even though titanium(Ti) and its alloys are the most used dental implant materials, there are some problems that Ti wears easily and interferes normal osteogenesis due to the metal ions. Ti coated with bioactive ceramics such as hydroxyapatite has also such problems as the exfoliation or resorption of the coated layer, Recent studies on implant materials have been proceeding to improve physical properties of the implant substrate and biocompatibility of the implant surfaces. The purpose of the present study was to examine the physical property and bone tissue compatibility of bioinert nitrides ion plated Ti, Button type specimens(14mm in diameter, 2.32rrun in height) for the abrasion test and cytotoxicity test and thread type implants(3.75mm in diameter, 6mm in length) for the animal experiments were made from Ti(grade 2) and 316LVM stainless steel. Ti specimens were ion plated with TiN, ZrN by the low temperature arc vapor deposition, and the depth profile of the TiN/Ti, ZrN/Ti ion plated surface was examined by Auger Electron Spectroscopy. Three kind of button type specimens .of TiN/Ti, ZrN/Ti and Ti were used for abrasion test, and HEPAlClC7 cells and CCD cells were cultivated for 4 days with the specimens for cytotoxicity test. Thread type implants of TiN/Ti, ZrN/Ti, Ti, 316LVM were implanted on the femur of 6 adult dogs weighing 10kg-13kg. Two dogs were sacrified for histological examination after 45 days and 90 days, and four dogs were sacrified for the removal torque test of the implant') after 90 days. The removal torque force was measured by Autograph (Shimadzu Co., AGS-1000D series, Japan). Abrasion resistance of TiN/Ti was the highest, and that of ZrN/Ti and Ti were followed. The bioinert nitride ion plated Ti had much better abrasion resistance, compared with Ti, In the cytotoxicity test, the number of both cells were increased in all specimens, and there were no significant difference in cytotoxic reaction among all groups (p>0.1), In histological examination, 316LVM showed the soft tissue engagement in interface between the implant and bone, but the other materials after 45 days noted immature new bone formation in the medullary portion along the implant surface, and those after 90 days showed implant support by new bone formation in both the cortical and the medullary portion, The removal torque force of Tilv/Ti showed significantly higher than that of Ti(p(O,05). The difference in removal torque force between TiN/Ti and ZrN/Ti was not significant(p>0.05), and that of 316LVM was lowest among all groups(p<0.05). These results suggest that bioinert nitrides ion plated Ti can resolve the existing problems of Ti and bioactive ceramics, and it may be clinically applicable to human.

  • PDF

표면처리방법에 따른 복합레진의 결합강도에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON THE SHEAR BOND STRENGTHS OF COMPOSITE RESIN TO AIR-ABRADED ENAMEL AND DENTIN)

  • 신재호;장기택;한세현
    • 대한소아치과학회지
    • /
    • 제24권1호
    • /
    • pp.112-124
    • /
    • 1997
  • According to extensive use of composite resin which have superior esthetic property, every effort on improving bonding strength between a tooth and composite resin has been continued. Acid etching technique is a method that micro-etches the tooth surface which provides bonding with composite resin possible. Recently, there were several reports that mechanical treatment obtained from air-abrasion can provide similar bonding strength with acid etching technique. So, this experimental study was designed to compare the shear bonding strength between using air-abrasion technique and using acid etching technique. Initially, bovine teeth were divided into enamel and dentin experimental groups. Respectively each group was categorized into three subgroups. One subgroup was acid etched with 35% phosphoric acid, then bonded with composite resin. The other subgroup was air-abraded with $50{\mu}m$ $Al_2O_3$ particles sprayed with 160psi air pressure using air abrasion unit(KCP-1000, A.D.T., U.SA), and composite resin was bonded. In another subgroup, composite resin was bonded after acid etching following air-abrasion. So, enamel experimental groups were made of E1 (acid etched only), E2(air-abraded only), E3(acid etched following air-abraded), and dentin experimental groups were made of D1(acid etched only), D2(air-abraded only), D3(acid etched following air-abraded). Each subgroup had 10 specimens. Dentin bonding system(Scotchbond Multi-purpose, 3M Co., U.S.A.) and composite resin(Z-100, 3M Co., U.S.A.) were applied on treated surface using 5mm diameter gelatin capsule as manufacturer's direction. After 1200 times thermocycling between $5^{\circ}C$ and $55^{\circ}C$, shear bond strength was measured in 5mm/min crosshead speed with Instron(Instron Co., U.S.A.), and also treated enamel and dentin were observed with SEM(JEOL Co., Japan). The following results were obtained: 1. In the enamel experimental groups, acid etched following air-abraded group had highest shear bond strength, but there was no significant difference compared to acid etched group. Air-abraded only group had lowest shear bond strength, and there was significant difference compared to the rest of groups. 2. In the dentin experimental groups, acid etched following air-abraded group had highest shear bond strength, but there was no significant difference compared to acid etched group. Air-abraded only group had lowest shear bond strength, and there was significant difference compared to the rest of groups. 3. In the SEM study, air-abraded enamel and dentin had irregular and rough surfaces.

  • PDF

재생 폴리에틸렌/비산회 분말 충전 복합체 제조와 기계적 물성, 내마모성 및 저속균열성장 저항성에 관한 연구 (A Study on the Manufacturing, Mechanical Properties,Abrasion Resistance, and Slow Crack Growth Resistance of the Recycled Polyethylene/Fly Ash Composites)

  • 계형산;신경철
    • Elastomers and Composites
    • /
    • 제46권4호
    • /
    • pp.335-342
    • /
    • 2011
  • 비산회를 첨가한 폐 PE의 직접적인 재활용 및 용도 개발을 위하여 재생 폴리에틸렌 수지와 순수 HDPE를 기본으로 비산회(fly ash)와 블렌드하여 비산회/재생 PE 복합재료를 치합형 동방향 회전 이축 압출기(fully intermeshing co-rotating twin screw extruder)를 이용하여 각 조성별로 제조하였다. 본 연구에서는 플라스틱 수지(재생 PE, HDPE)와 비산회의 혼합비를 (0~40) wt.%로 하였고 비산회의 함량 변화에 따른 물성을 비교하였다. 세 종류의 PE 모두 비산회 함량이 증가할수록 항복인장강도가 감소하고, 파단신율이 감소한다. 내마모성 시험 결과는 사포 거칠기가 증가할수록 내마모성이 떨어지고 거칠기가 감소할수록 충전제의 함량에 따라 내마모성이 증가한다. Notched Constant Ligament Stress 시험에서는 신재 PE와 재생 PE의 경우 하중의 변화에 따라 파괴 시간이 짧아지는 결과를 나타냈고, 비산회가 혼합된 KRPE 복합체는 신재 PE, 폐 PE 그리고 신재 PE 복합체 및 JRPE 복합체와 비교할 때 상대적인 파괴 시간은 짧게 나타나지만 매설용 구조물에 대한 한국산업표준에서 정하는 20% 노치 깊이, 15%의 하중에서 24시간 이상의 저속 균열저항성을 나타내어 지하매설용 구조체로서 하수 이음관/받침대와 옥외구조물로서 가로수 보호의자와 같은 구조물에 적용할 수 있을 것으로 판단한다.

Peel strength of denture liner to PMMA and polyamide: laser versus air-abrasion

  • Korkmaz, Fatih Mehmet;Bagis, Bora;Ozcan, Mutlu;Durkan, Rukiye;Turgut, Sedanur;Ates, Sabit Melih
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권3호
    • /
    • pp.287-295
    • /
    • 2013
  • PURPOSE. This study investigated the effect of laser parameters and air-abrasion on the peel strength of silicon-based soft denture liner to different denture resins. MATERIALS AND METHODS. Specimens (N=180) were prepared out of three different denture base resins (Rodex, cross-linked denture base acrylic resin; Paladent, heat-cured acrylic resin; Deflex, Polyamide resin) ($75mm{\times}25mm{\times}3mm$). A silicon-based soft denture liner (Molloplast B) was applied to the denture resins after the following conditioning methods: a) Air-abrasion ($50{\mu}m$), b) Er,Cr:YSGG laser (Waterlase MD Turbo, Biolase Technology) at 2 W-20 Hz, c) Er,Cr:YSGG laser at 2 W-30 Hz, d) Er,Cr:YSGG laser at 3 W-20 Hz, e) Er,Cr:YSGG laser at 3 W-30 Hz. Non-conditioned group acted as the control group. Peel test was performed in a universal testing machine. Failure modes were evaluated visually. Data were analyzed using two-way ANOVA and Tukey's test (${\alpha}$=.05). RESULTS. Denture liner tested showed increased peel strength after laser treatment with different parameters ($3.9{\pm}0.4-5.58{\pm}0.6$ MPa) compared to the control ($3.64{\pm}0.5-4.58{\pm}0.5$ MPa) and air-abraded groups ($3.1{\pm}0.6-4.46{\pm}0.3$ MPa), but the results were not statistically significant except for Paladent, with the pretreatment of Er,Cr:YSGG laser at 3 W-20 Hz. Polyamide resin after air-abrasion showed significantly lower peel strength than those of other groups ($3.1{\pm}0.6$ MPa). CONCLUSION. Heat-cured acrylic resin, PMMA, may benefit from Er,Cr:YSGG laser treatment at 3 W-20 Hz irradiation. Air-abrasion of polyamide resins should be avoided not to impair their peel bond strengths to silicon-based soft denture liners.