• 제목/요약/키워드: a three-dimensional

검색결과 12,965건 처리시간 0.054초

ONE-DIMENSIONAL TREATMENT OF MOLECULAR LINE RADIATIVE TRANSFER IN CLUMPY CLOUDS

  • Park, Yong-Sun
    • 천문학회지
    • /
    • 제54권6호
    • /
    • pp.183-190
    • /
    • 2021
  • We have revisited Monte Carlo radiative transfer calculations for clumpy molecular clouds. Instead of introducing a three-dimensional geometry to implement clumpy structure, we have made use of its stochastic properties in a one-dimensional geometry. Taking into account the reduction of spontaneous emission and optical depth due to clumpiness, we have derived the excitation conditions of clumpy clouds and compared them with those of three-dimensional calculations. We found that the proposed approach reproduces the excitation conditions in a way compatible to those from three-dimensional models, and reveals the dependencies of the excitation conditions on the size of clumps. When bulk motions are involved, the applicability of the approach is rather vague, but the one-dimensional approach can be an excellent proxy for more rigorous three-dimensional calculations.

안면골 외상환자의 전산화단층상을 이용한 삼차원재구성상의 비교연구 (A COMPARATIVE STUDY OF THREE DIMENSIONAL RECONSTRUCTIVE IMAGES USING COMPUTED TOMOGRAMS OF FACIAL BONE INJURIES)

  • 최은숙;고광준
    • 치과방사선
    • /
    • 제24권2호
    • /
    • pp.413-423
    • /
    • 1994
  • The purpose of this study was to clarify the spatial relationship in presurgical examination and to aid surgical planning and postoperative evaluation of patients with facial bone injury. For this study, three-dimensional images of facial bone fracture were reconstructed by computed image analysis system and three-dimensional reconstructive program integrated in computed tomography. The obtained results were as follows: 1. Serial conventional computed tomograms were value in accurately depicting the facial bone injuries and three-dimensional reconstructive images demonstrated an overall look. 2. The degree of deterioration of spatial resolution was proportional to the thickness of the slice. 3. Facial bone fractures were the most distinctly demonstrated on inferoanterior views of three-dimensional reconstructive images. 4. Although three-dimensional reconstructive images made diagnosis of fracture lines, it was difficult to identify maxillary fractures. 5. The diagnosis of zygomatic fractures could be made equally well with computed image analysis system and three-dimensional reconstructive program integrated in computed tomography. 6. The diagnosis of mandibular fractures could be made equally well with computed image analysis system and three-dimensional reconstructive program integrated in computed tomography.

  • PDF

Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition

  • Rhee, Ye-Kyu;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권6호
    • /
    • pp.460-467
    • /
    • 2015
  • PURPOSE. The aim of this study is to evaluate the appropriate impression technique by analyzing the superimposition of 3D digital model for evaluating accuracy of conventional impression technique and digital impression. MATERIALS AND METHODS. Twenty-four patients who had no periodontitis or temporomandibular joint disease were selected for analysis. As a reference model, digital impressions with a digital impression system were performed. As a test models, for conventional impression dual-arch and full-arch, impression techniques utilizing addition type polyvinylsiloxane for fabrication of cast were applied. 3D laser scanner is used for scanning the cast. Each 3 pairs for 25 STL datasets were imported into the inspection software. The three-dimensional differences were illustrated in a color-coded map. For three-dimensional quantitative analysis, 4 specified contact locations(buccal and lingual cusps of second premolar and molar) were established. For two-dimensional quantitative analysis, the sectioning from buccal cusp to lingual cusp of second premolar and molar were acquired depending on the tooth axis. RESULTS. In color-coded map, the biggest difference between intraoral scanning and dual-arch impression was seen (P<.05). In three-dimensional analysis, the biggest difference was seen between intraoral scanning and dual-arch impression and the smallest difference was seen between dual-arch and full-arch impression. CONCLUSION. The two- and three-dimensional deviations between intraoral scanner and dual-arch impression was bigger than full-arch and dual-arch impression (P<.05). The second premolar showed significantly bigger three-dimensional deviations than the second molar in the three-dimensional deviations (P>.05).

디지털 화상처리를 이용한 유동장의 비접촉 3차원 고속류 계측법의 개발 (Developemet of noncontact velocity tracking algorithm for 3-dimensional high speed flows using digital image processing technique)

  • 도덕희
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권2호
    • /
    • pp.259-269
    • /
    • 1999
  • A new algorithm for measuring 3-D velocity components of high speed flows were developed using a digital image processing technique. The measuring system consists of three CCD cameras an optical instrument called AOM a digital image grabber and a host computer. The images of mov-ing particles arranged spatially on a rotation plate are taken by two or three CCD cameras and are recorderd onto the image grabber or a video tape recoder. The three-dimensionl velocity com-ponents of the particles are automatically obtained by the developed algorithm In order to verify the validity of this technique three-dimensional velocity data sets obtained from a computer simu-lation of a backward facing step flow were used as test data for the algorithm. an uncertainty analysis associated with the present algorithm is systematically evaluated, The present technique is proved to be used as a tookl for the measurement of unsteady three-dimensional fluid flows.

  • PDF

3차원 공간 위상 관계 연산자의 설계 (Design of Three Dimensional Spatial Topological Relational Operators)

  • 김상호;강구;류근호
    • 정보처리학회논문지D
    • /
    • 제10D권2호
    • /
    • pp.211-220
    • /
    • 2003
  • 지리정보시스템은 3차원 위상정보를 표현함으로써 사용자에게 정확하고 정교한 서비스를 제공한다. 이 때에 3차원 위상정보연산을 위해 차원변경방식과 서로 이질적인 공간모델을 사용해야 하는데, 이 방식을 사용할 때는 공간 연산이 어려울 뿐 아니라 서로 호환성이 부족한 문제가 발생한다. 따라서 이 논문에서는 이 문제를 해결하기 위하여 2차원 공간 객체 모델을 수용하는 3차원 공간 객체 모델을 제안하였고, 타당성을 보이기 위하여 구현하여, 그 실행을 보였다. 3차원 공간 위상 관계 연산자를 위하여 DE-9IM 방식을 3차원 개념으로 정의한 DE-9IM을 이용해서 설계하였고, 객체지향 개념을 지원하는 컴포넌트 환경에서 3차원 공간 위상 연산자를 구현하였다. 이 논문에서 제안된 3차원 공간 위상 연산자는 타 시스템과의 상호 운용성을 보장하며, 구현된 공간 위상 관계 연산을 이용하여, 3차원 공간 객체에 대한 효율적인 공간 질의를 수행할 수 있다.

A camera calibration technique and landscape simulation

  • Fujimoto, Kazutaka;Watase, Motoaki;Yamamoto, Masayuki;Ishimatsu, Takakazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.295-298
    • /
    • 1995
  • In this paper, one simple technique to calibrate the system setting of the three-dimensional measuring system is presented. Due to this technique, the three-dimensional shape of the huge structures and the buildings can be readily obtained. This technique is applied to the three-dimensional landscape simulation. Two examples are shown in this paper.

  • PDF

3차원 곡면에 정밀 인쇄를 위한 공정 변수에 따른 이미지 보정에 관한 연구 (A study of correction dependent on process parameters for printing on a three-dimensional surface)

  • 송민섭;김효찬;이상호;양동열
    • 한국정밀공학회지
    • /
    • 제23권2호
    • /
    • pp.181-190
    • /
    • 2006
  • In the industry, three-dimensional coloring has been needed for a realistic prototype. The Z-corporation developed a 3D printer which provides a three-dimensional colored prototype. However, the process cannot be adopted to models fabricated by other rapid prototyping processes. In addition, time and cost for manufacturing colored prototypes still remain to be improved. In this study, a new coloring process using an ink-jet head is proposed for color printing on a three-dimensional surface. Process parameters such as the angle and the distance between the ink-jet nozzle and the three-dimensional surface should be investigated through experiments. In order to minimize the distortion of a 2D image, the correction matrix according to the sloped angle is proposed and obtained by analysis of printing errors. An image on the doubly curved surface is printed so as to verify the proposed method. As a practical example, a helmet is chosen for printing images on the curved surface. The practical applicability of the correction matrix is then demonstrated by printing the character images on the surface of the helmet.

Tomographic Reconstruction of a Three-Dimensional Flow Field with Limited Interferometric Data

  • Cha, Dong-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권2호
    • /
    • pp.11-22
    • /
    • 2000
  • Holographic interferometric tomography can provide reconstruction of instantaneous three-dimensional gross flow fields. The technique however confronts ill-posed reconstruction problems in practical applications. Experimental data are usually limited in projection and angular scanning when a field is captured instantaneously or under the obstruction of test models and test section enclosures. An algorithm, based on a series expansion method, has been developed to improve the reconstruction under the ill-posed conditions. A three-dimensional natural convection flow around two interacting isothermal cubes is experimentally investigated. The flow can provide a challenging reconstruction problem and lend itself to accurate numerical solution for comparison. The refractive index fields at two horizontal sections of the thermal plume with and without an opaque object are reconstructed at a limited view angle of 80$\circ$. The experimental reconstructions are then compared with those from numerical calculation and thermocouple thermometry. It confirms that the technique is applicable to reconstruction of reasonably complex, three-dimensional flow fields.

  • PDF

A Three-dimensional Magnetic Field Mapping System for Deflection Yoke of Cathode-Ray Tube

  • Park, K.H.;Yoon, M.;Lee, S.M.;Joo, H.D.;Lee, S.D.;Yang, W.Y.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.868-871
    • /
    • 2002
  • In this paper, we introduce an efficient three-dimensional magnetic field mapping system for a Deflection Yoke (DY) in Cathode-Ray Tube (CRT). A three-axis Hall probe mounted in a small cylindrical bar and three stepping motors placed in a nonmagnetic frame are utilized for the mapping. Prior to the mapping starts, the inner contour of DY is measured by a laser sensor to make a look-up table for inner shape of DY. Three-axis magnetic fields are then digitized by a three-dimensional Hall probe. The results of the mapping can be transformed to various output formats such as multipole harmonics of magnetic fields. Field shape in one, two and three-dimensional spaces can also be displayed. In this paper, we present the features of this mapping device and show some analysis results.

  • PDF

Numerical Analysis of Three Dimensional Supersonic Flow around Cavities

  • Woo Chel-Hun;Kim Jae-Soo;Kim Jong-Rok
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2006년도 PARALLEL CFD 2006
    • /
    • pp.311-314
    • /
    • 2006
  • The supersonic flow around tandem cavities was investigated by three- dimensional numerical simulations using the Reynolds-Averaged Navier-Stokes(RANS) equation with the $\kappa-\omega$ thrbulence model. The flow around a cavity is characterized as unsteady flow because of the formation and dissipation of vortices due to the interaction between the freestream shear layer and cavity internal flow, the generation of shock and expansion waves, and the acoustic effect transmitted from wake flow to upstream. The upwind TVD scheme based on the flux vector split using van Leer's limiter was used as the numerical method. Numerical calculations were performed by the parallel processing with time discretizations carried out by the 4th-order Runge-Kutta method. The aspect ratio of cavities are 3 for the first cavity and 1 for the second cavity. The ratio of cavity interval to depth is 1. The ratio of cavity width to depth is 1 in the case of three dimensional flow. The Mach number and the Reynolds number were 1.5 and $4.5{\times}10^5$, respectively. The characteristics of the dominant frequency between two-dimensional and three-dimensional flows were compared, and the characteristics of the second cavity flow due to the fire cavity flow cavity flow was analyzed. Both two dimensional and three dimensional flow oscillations were in the 'shear layer mode', which is based on the feedback mechanism of Rossiter's formula. However, three dimensional flow was much less turbulent than two dimensional flow, depending on whether it could inflow and outflow laterally. The dominant frequencies of the two dimensional flow and three dimensional flows coincided with Rossiter's 2nd mode frequency. The another dominant frequency of the three dimensional flow corresponded to Rossiter's 1st mode frequency.

  • PDF