• Title/Summary/Keyword: a squid

Search Result 655, Processing Time 0.027 seconds

Design and Construction of an HTS DC SQUID Electronic Gradiometer NDE system

  • Kim, J.Y.;Han, S.G.;Kang, J.H.;Lee, E.H.;Song, I.H.
    • Progress in Superconductivity
    • /
    • v.1 no.2
    • /
    • pp.115-119
    • /
    • 2000
  • We designed and constructed a non-destructive evaluation system using an HTS DC SQUID electronic gradiometer. Our DC SQUID electronic gradiometer is composed of two DC SQUID magnetometers. The system included a non-magnetic stainless steel cryostat and a set of coaxial exciting coils, which were used to induce an eddy current in the test piece. We also have calculated the eddy current density produced by an exciting coil in any direction of the testing object. We could compute the eddy current density distribution in 3D. The SQUIDs were computer controlled and the output data from the electronic gradiometer was obtained by using a Labview software.

  • PDF

A semispherical SQUID magnetometer system using high sensitivity double relaxation oscillation SQUIDs for magnetoencephalographic measurements

  • Lee, Yong-Ho;Hyukchan Kwon;Kim, Jin-Mok;Kim, Kwoong;Park, Yong-Ki
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.21-26
    • /
    • 2003
  • We designed and constructed a multichannel superconducting quantum interference device (SQUID) magnetometer system to measure magnetic fields from the human brain. We used a new type of SQUID, the double relaxation oscillation SQUID (DROS). With high flux-to-voltage transfers of the DROS, about 10 times larger than the dc SQUIDs, simple flux-locked loop circuits could be used for SQUID operation. Also the large modulation voltage of the DROS, typically being 100 $mutextrm{V}$, enabled stable flux-locked loop operation against the thermal offset voltage drift of the preamplifier. The magnetometers were fabricated using the Nb/AlOx/Nb junction technology. The SQUID system consists of 37 signal magnetometers, distributed on a semispherical surface, and 11 reference channels were installed to pickup background noises. External feedback was used to eliminate the magnetic coupling with the adjacent channels. The liquid helium dewar has a capacity of 29 L and boil-off rate of about 4 L/d with the total 48 channel insert. The magnetometer system has an average noise level of 3 fT/√Hz at 100 Hz, inside a shielded loon, and was applied to measure auditory-evoked fields.

Construction of a 40-channel SQUID System and Its Application to Neuromagnetic Measurements

  • Lee, Y.H.;Kim, J.M.;Kwon, H.C.;Park, Y.K.;Park, J.C.;Lee, D.H.;Ahn, C.B.
    • Progress in Superconductivity
    • /
    • v.2 no.1
    • /
    • pp.20-26
    • /
    • 2000
  • A 40-channel superconducting quantum interference device (SQUID) system was constructed for measuring neuromagnetic fields. Main features of the system are the use of double relaxation oscillation SQUIDs (DROSs), and planar gradiometers measuring magnetic field components tangential to the head surface. The DROSs with high flux-to-voltage transfers enabled direct readout of the SQUID output by room-temperature dc preamplifiers and simple flux-locked loop circuits could be used for SQUID operation. The pickup coil is an integrated first-order planar gradiometer with a baseline of 40 mm. Average noise level of the 40 channels is around 1.2 $fT/cm/{\surd}Hz$ at 100 Hz, corresponding to a field noise of 5 $fT/{\surd}Hz$, operated inside a magnetically shielded room. The SQUID insert was designed to have low thermal load, minimizing the loss of liquid helium. The constructed system was applied to measure auditory-evoked neuromagnetic fields.

  • PDF

Measurement of weak magnetic signals using high-$T_c$ SQUID magnetometers in magnetically disturbed environment (High-$T_c$ SQUID 자력계를 이용한 자기잡음 환경에서의 미세자기신호 측정 및 분석)

  • 김인선;유권규;박용기
    • Progress in Superconductivity
    • /
    • v.4 no.2
    • /
    • pp.121-126
    • /
    • 2003
  • The single layer direct-coupled YBCO SQUID magnetometers have been fabricated and characterized for the purpose of the measurement of weak magnetic signals in unshielded environment. Two types of magnetometers have been designed and fabricated using 10 mm$\times$ 10 mm substrates. We could operate the conventional 3-mm-wide solid pickup loop magnetometers more stably than the 12-parallel-line pickup loop magnetometers in laboratory environment. We developed a first-order electronic gradiometer system using the SQUID sensors with axial displacement of 80 mm without any mechanical alignment of magnetometers. The system with a software filter using calculation of discrete Fourier transform could record clearly weak pulse signal of 100 pT in a magnetically disturbed environment.

  • PDF

Numerical study of topological SQUIDs

  • Soohong, Choi;Yeongmin, Jang;Sara, Arif;Yong-Joo, Doh
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.4
    • /
    • pp.11-15
    • /
    • 2022
  • We conducted numerical calculations to obtain the critical current as a function of the magnetic flux through the topologically trivial and non-trivial superconducting quantum interference devices (SQUIDs), with varying the capacitive and inductive couplings of Josephson junctions (JJs). Our calculation results indicate that a nontrivial SQUID is almost indistinguishable from trivial SQUID, considering the effective capacitance coupling. When the SQUID contains 2π- and 4π-periodic supercurrents, the periodicity of the current-flux relation can be distinguished from the purely trivial or nontrivial SQUID cases, and its difference is sensitive to the relative ratio between the topologically trivial and nontrivial supercurrents. We believe that our calculation results would provide a practical guide to quantitatively measure the portion of the topologically nontrivial supercurrents in experiments.

Construction and Operation of a 40-channel SQUID System for Neuromagnetic Measurements (40-채널 SQUID 시스템의 제작 및 뇌자도 측정)

  • Lee, Yong-Ho;Kim, Jin-Mok;Kwon, Hyuk-Chan;Lee, Sang-Kil;Lim, Cheong-Moo;Park, Yong-Ki;Park, Jong-Chul
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.27-32
    • /
    • 1999
  • We developed a 40-channel superconducting quantum interference device (SQUID) system for neuromagnetic measurements. The main features of the system are use of double relaxation oscillation SQUID (DROS), and planar gradiometer for measuring tangential field components. The DROSS with high flux-to-voltage transfers enabled direct readout of the SQUID output by room-temperature electronics and simple flux-locked loop circuits could be used for SQUID operation. The pickup coil is an integrated first-order planar gradiometer with a baseline of 40 mm. The average noise of the 40 channels is around 1.2 fT/cm/${\sqrt{Hz}}$ at 100 Hz, corresponding to the field noise of 5 fT/${\sqrt{Hz}}$ at 100 Hz, operated inside a magnetically shielded room. The 40-Channel system was applied to measure auditory-evoked neuromagnetic fields.

  • PDF

Biofunctional Properties of Enzymatic Squid Meat Hydrolysate

  • Choi, Joon Hyuk;Kim, Kyung-Tae;Kim, Sang Moo
    • Preventive Nutrition and Food Science
    • /
    • v.20 no.1
    • /
    • pp.67-72
    • /
    • 2015
  • Squid is one of the most important commercial fishes in the world and is mainly utilized or consumed as sliced raw fish or as processed products. The biofunctional activities of enzymatic squid meat hydrolysate were determined to develop value-added products. Enzymatic squid hydrolysate manufactured by Alcalase effectively quenched 1,1-diphenyl-2-picrylhydrazyl radical, hydroxyl radical, and hydrogen peroxide radical with $IC_{50}$ values of 311, 3,410, and $111.5{\mu}g/mL$, respectively. Angiotensin I-converting enzyme inhibitory activity of squid hydrolysate was strong with an $IC_{50}$ value of $145.1{\mu}g/mL$, while tyrosinase inhibitory activity with an $IC_{50}$ value of 4.72 mg/mL was moderately low. Overall, squid meat hydrolysate can be used in food or cosmetic industries as a bioactive ingredient and possibly be used in the manufacture of seasoning, bread, noodle, or cosmetics.

Influences of Squid Ink Added to Low Salt Fermented Squid on Its Changes in Lactic Acid Bacteria (저염 오징어 젓갈의 숙성 중 오징어 먹즙 첨가가 젖산균의 변화에 미치는 영향)

  • Oh, Sung-Cheon
    • The Korean Journal of Food And Nutrition
    • /
    • v.26 no.4
    • /
    • pp.678-684
    • /
    • 2013
  • This study measured the change of lactic acid bacteria during the ripening fermentation process of low salt fermented squid with no squid ink added. All study groups showed increase of Leuconostoc and rapid growth of total plate count at the beginning stage of ripening and the maximum microbial count showed at the optimum stage of ripening which gradually reduced after the optimum stage. It is believed that Lactobacillus occupied the major part of the total plate count after the optimum stage of the squid fermentation, and it was related to the quality after the optimized ripening stage. Streptococcus and Pediococcus were gradually increased until the optimum stage of the ripening, and then decreased rapidly. Yeasts were detected in the middle stage of the fermentation and rapid increase was shown after the last stage of the fermentation which suggests that yeasts participate in putrefaction of the low salt fermented squid. The change of lactic acid bacteria observed during the ripening fermentation of low salt fermented squid with squid ink added was that the total plate count increased until ripening middle stage but showed a tendency to slightly reduce after the middle stage. The length of time to reach the maximum value was longer than the no treatment groups. Among the lactic acid bacteria, Leuconostoc, Streptococcus and Pediococcus has increased until the middle stage of the ripening while Lactobacillus constantly increased to the end part of the ripening. Yeasts had no increasing in the early ripening stage, but after middle of the ripening, it started to increase. That kind of tendency was similar to the case of no treatment groups. However, the amount of lactic acid bacteria tended to be less than no treatment groups. The tendency of decreasing number of all bacteria in low salt fermented squid with squid ink added shows squid ink restricts the growth of all bacteria.

Fabrication of sing1e layer $d^2B_{z}$/dxdy second-order SQUID gradiometer (단일층 $d^2B_{z}$/dxdy SQUID 2차 미분기 설계 및 제작)

  • 황윤석;박승문;이순걸;김인선;박용기
    • Progress in Superconductivity
    • /
    • v.4 no.2
    • /
    • pp.109-113
    • /
    • 2003
  • We have developed a planar-type single layer second-order $high-T_{c}$ SQUID gradiometer, which can detect the $d^2$$B_{z/}$dxdy of the second-order field gradient. This SQUID gradiometer consists of four-way 'clover-leaf' pick-up loops and is coupled directly to a 4-junction dc SQUID in such a way that the coupling polarity of the two diagonal loops is opposite to that of the other two loops. The pickup loops are intrinsically balanced for both uniform field and the 1 st-order field gradient. The $YBa_2$$Cu_3$$O_{7}$ thin film was made by pulsed laser deposition method on $SrTiO_3$ single crystal substrate and patterned by photolithography with Ar ion milling technique. Response of this gradiometer was tested for both uniform field and the 2nd-order field gradient. Details of the design, fabrication, and results will be discussed.

  • PDF

Fabrication of HTS SQUID Sensors for the Application to a High S/N Ratio Magnetocardiograph System (저잡음 심자도측정시스템 개발을 위한 고온초전도 SQUID 센서의 제작)

  • Kim I. S;Yu K. K;Park Y. K
    • Progress in Superconductivity
    • /
    • v.6 no.1
    • /
    • pp.19-23
    • /
    • 2004
  • YBCO do superconducting quantum interference device (SQUID) magnetometers based on bicrystal Josephson junctions on 10 mm ${\times}$ 10 mm $SrTiO_3$ substrates have been fabricated. The pickup coil of the device was designed to have 16 parallel loops with 50-fm-wide lines. We could obtain optimised direct coupled YBCO SQUID magnetometer design with field sensitivity $B_{N}$ $\Phi$/ of $4.5 nT/\Phi_{0}$ and magnetic field noise $B_{N}$ of about $22 fT/Hz^{1}$2/ with an I/f corner frequency of 2 Hz measured inside a magnetically shielded room. Preliminary results of magnetocardiograph measurement using the HTS SQUID magnetometers show signal to noise ratio of about 110, which is comparable to the quality of a commercial MCG system based on Nb-SQUIDs.

  • PDF