• 제목/요약/키워드: a slip frequency vector control

검색결과 59건 처리시간 0.021초

퍼지 알고리즘을 이용한 유도전동기 간접벡터제어기의 설계와 엘리베이터 속도제어 시스템의 응용 (Design of Indirect Vector Controller of Induction Motor using Fuzzy Algorithm and apply to the Speed Control System of Elevator)

  • 경제문;김훈모
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.110-113
    • /
    • 2000
  • In general, speed control method of the elevator system has used motor pole change type or motor primary voltage control type. But it will change to vector control type in order to increase it's reliability, riding comfort and decrease material cost. It is the conception of vector control type in order to increase it's reliability, riding comfort and decrease material cost. It is the conception of vector control that primary current of the induction motor be controlled independently with magnetizing current(field current of DC motor) and torque current(armature current of DC motor). In this paper, by analyzing the effect of the time constant variation of rotor of the induction motor on the slip frequency type indirect vector control, a drive system for the motor will be constructed using a fuzzy slip frequency type indirect vector controller with fuzzy control method for estimating the vector time constant in the slip frequency type indirect vector control. The goal of this study is to enabling even more efficient speed control by constructing on elevator driver based on the newly developed drive system.

  • PDF

가변구조제어 이론을 이용한 유도 서보 전동기의 위치제어 (Position Control for Induction Servo Motors Using a Theory of Variable Structure Control)

  • 홍순일;홍정표
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권1호
    • /
    • pp.132-139
    • /
    • 2005
  • This paper describes the application of sliding mode control based on the variable structure control(VSC) concept for high-performance position control of an induction servo motor A design method based on external load parameters has been developed for the robust control of AC induction servo drive. Also, a slip frequency vector control with software current control technique has been adopted to achieve fast response of an induction motor drive The position control scheme is comprised of a variable structure controller and slip frequency vector control for inverter fed induction servo motor. Simulated results are given to verify the proposed design method by adoption of sliding mode and show robust control for a change of shaft inertia, viscous friction and torque disturbance.

High performance torque control of induction motor by speed sensorless vector control

  • Harashima, Fumio;Kondo, Seiji;Inoue, Shuji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.1410-1414
    • /
    • 1990
  • A method of speed sensorless vector control of induction motor is proposed in this paper. This method uses the slip frequency estimated by only the primary voltage and current. As this slip frequency accords with the command value of it, the commanded primary frequency is controlled. The validity of the method is confirmed by the simulation and experimental results.

  • PDF

블록 적응알고리즘을 이용한 유도전동기 적응벡터제어 (Adaptive Vector Control for Induction Motor Using Block Adaptive Algorithm)

  • 박영산;조성훈;배철오;이성근;김윤식
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 1999년도 춘계종합학술대회
    • /
    • pp.324-329
    • /
    • 1999
  • This paper proposes new torque control of an induction motor, which is robust against time verying parameters. The control is based on adaptive vector control with serial block adaptive algorithm. Motor parameters used to estimates slip frequency and torque. Frequency mismatch in the control system detrimentally affects slip frequency estimation and torque response. In order to compensate for degradation of the responses an adaptive identifier for the magnetizing inductance and the secondary time constand is introduced. adaptive vector control system consisted of two subsystems, a vector control system realized on synchronous frame and a parameter identification system on stationary frame. the effectiveness of the proposed method was verified by some digital simulations.

  • PDF

유도전동기 회전자 저항 보상을 위한 벡터제어 (Vector Control for the Rotor Resistance Compensation of Induction Motor)

  • 박현철;이수원;김영민;황종선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.65-68
    • /
    • 2001
  • In the vector control methods of induction motor, the stator current is divided into the flux and torque component current. By controlling these components respectively, the methods control independently flux and torque as in the DC motor and improve the control effects. To apply the vector control methods, the position of the rotor current is identified. The indirect vector control use the parameters of the machine to identify the position of rotor flux. But due to the temperature rise during machine operation, the variation of rotor resistance degrades the vector control. To solve the problem, the q-axis is aligned to reference frame without phase difference by comparing the real flux component with the reference flux component. Then to compensate the slip, PI controller is used. The proposed method keeps a constant slip by compensating the gain of direct slip frequency when the rotor resistance of induction motor varies. To prove the validations of the proposed algorithm in the paper, computer simulations is executed.

  • PDF

열차 추진제어장치의 알고리즘에 관한 연구 (A Study of Control Algorithm for Propulsion System)

  • 최재호;김형철
    • 한국철도학회논문집
    • /
    • 제10권1호
    • /
    • pp.51-56
    • /
    • 2007
  • In this paper, control schemes are developed for a propulsion system(Converter/Inverter) in electrical train. A robust controller for PWM converter is proposed. The converter controller consists of a PI controller for DC output voltage and a current controller using error-space approach for maintaining the sinusoidal current waveform and unity power factor. This proposed method is based on characteristic ratio assignment(CRA) method which has the advantage to design the optimal gain to meet the referenced response and overshoot within the limit range. Inverter system is controlled by vector control and slip frequency control. At low speed region, vector control scheme is applied to control instantaneous torque and slip frequency control is performed under overmodulation region and one pulse mode. Because output voltage of converter contains harmonics ripple at twice input ac line frequency, control scheme is developed to reduce the pulsating torque current. The performance of propulsion system will be verified by simulation and prototype experimental results.

도시형 자기부상열차 적용을 위한 추진제어장치의 개발 (Development of propulsion system for the Urban Transit Maglev System)

  • 이은규;송영신;최재호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 추계학술대회 논문집(I)
    • /
    • pp.440-445
    • /
    • 2002
  • In this paper, traction system for urban transit maglev system is proposed. Using vector control strategy to control magnitude and frequency of output voltage transiently is general. But in case of traction system for railway vehicle, it is impossible that adapt vector control because there is one-pulse mode in a high speed region. So this paper proposes the control strategy using vector control in a low speed region and slip frequency control in a high speed region. And also proposes overmodulation method that makes to change in one-pulse mode softly. The performance of traction system will be verified by simulation results using ACSL.

  • PDF

슬립추정 센서리스 벡터 제어기 (Slip Estimated Sensorless Vector Controller)

  • 한상수
    • 한국정보통신학회논문지
    • /
    • 제14권10호
    • /
    • pp.2299-2304
    • /
    • 2010
  • 유도 모터의 센서리스벡터 제어시스템은 모터의 시정수를 이용하여 자극의 위치를 추정하는 제어 시스템으로서 중 고속영역의 경우 벡터 제어가 잘 구현된다. 그러나 저속의 경우 모터로부터 얻는 전압정보가 너무 작아서 벡터 제어기의 구현이 어렵다. 본 논문에서는 슬립 주파수 추정을 이용하여 저속에서의 센서리스벡터제어 문제점을 개선시켜 광범위한 속도 영역에서 벡터제어가 가능한 센서리스 벡터제어기를 설계하였다. 제어기의 성능은 실험을 통하여 확인하였다.

A new flux observer based vector control in induction motors

  • Tsuji, Mineo;Li, Hanqiang;Izumi, Katsuhiro;Kobuchi, Taiki;Yamada, Eiji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1994년도 Proceedings of the Korea Automatic Control Conference, 9th (KACC) ; Taejeon, Korea; 17-20 Oct. 1994
    • /
    • pp.708-713
    • /
    • 1994
  • A new flux observer based vector control system of an induction motor is constructed by using an observer in which the commanded stator currents are used to estimate the rotor flux. In this system, the flux observer is formulated by using a model of induction motor in a stationary coordinate system. By considering an observer of induction motor in a fixed co-ordinate system located on its secondary flux, a slip frequency controlled type of vector control system is also proposed. From these control schemes, the relation between the conventional slip frequency controlled type system and the observer based one is clarified. The steady-state error of the developed torque which is caused by the parameter change of induction motor is analyzed and discussed for the selection of observer gains. The poles of the observer error dynamics and those of the observer based vector control system are calculated analytically by neglecting the machine parameter change. In order to analyze the robust stability, a linear model of the observer based vector control system is proposed taking into account the machine parameter change. By using this model, the trajectories of the poles and zeros of the torque transfer function are computed and discussed. To test validity of the theoretical analysis, experiments are conducted by using a digital signal processor (TMS320C30) and a current controlled voltage source PWM inverter.

  • PDF

유도전동기 회전자 저항 보상을 위한 벡터제어 (Vector Control for the Rotor Resistance Compensation of Induction Motor)

  • 박현철;이수원;김영민;황종선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.65-68
    • /
    • 2001
  • In the vector control methods of induction motor, the stator current is divided into the flux and torque component current. By controlling these components respectively, the methods control independently flux and torque as in the DC motor and improve the control effects. To apply the vector control methods, the position of the rotor current is identified. The indirect vector control use the parameters of the machine to identify the position of rotor flux. But due to the temperature rise during machine operation, the variation of rotor resistance degrades the vector control. To solve the problem, the q-axis is aligned to reference frame without phase difference by comparing the real flux component with the reference flux component. Then to compensate the slip, PI controller is used. The proposed method keeps a constant slip by compensating the gain of direct slip frequency when the rotor resistance of induction motor varies. To prove the validations of the proposed algorithm in the paper, computer simulations is executed.

  • PDF