• 제목/요약/키워드: a remote radiation measurement

검색결과 39건 처리시간 0.027초

네트워크를 이용한 온실 감시 시스템의 개발 (Development of a Greenhouse Monitoring System Using Network)

  • 임정호;류관희;진제용
    • Journal of Biosystems Engineering
    • /
    • 제28권1호
    • /
    • pp.53-58
    • /
    • 2003
  • This study was carried out to design, construct, and test a greenhouse monitoring system fur the environment and status of control devices in a greenhouse from a remote site using internet. The measuring items selected out of many environmental factors were temperature, humidity, solar radiation, CO$_2$, SOx, NOx concentration, EC, pH of nutrient solution, the state of control devices, and the image of greenhouse. The developed greenhouse monitoring system was composed of the network system and the measuring module. The network system consists of the three kinds of monitors named the Croup Monitor. the Client Monitor and the Server Monitor. The results of the study are summarized as follows. 1. The measuring module named the House Monitor. which is used to watch the state of the control device and the environment of the greenhouse, was developed to a embedded monitoring module using one chip microprocessor 2. For all measuring items. the House Monitor showed a satisfactory accuracy within the range of ${\pm}$0.3%FS. The House Monitors were connected to the Croup Monitor by communication method of RS-485 type and could operate under power and communication fault condition within 10 hours. The Croup Monitor was developed to receive and display measurement data received from the House Monitors and to control the greenhouse environmental devices. 3. The images of the plants inside greenhouse were captured by PC camera and sent to the Group Monitor. The greenhouse manager was able to monitor the growth state of plants inside greenhouse without visiting individual greenhouses. 4. Remote monitoring the greenhouse environment and status of control devices was implemented in a client/server environment. The client monitor of the greenhouse manager at a remote site or other greenhouse manager was able to monitor the greenhouse environment and the state of control devices from the Server Monitor using internet.

원격 측정 기법을 이용한 토양 함수비의 측정 (Soil Moisture Content Estimation Using Remote Sensing Technique)

  • 이재수
    • 대한토목학회논문집
    • /
    • 제14권3호
    • /
    • pp.535-542
    • /
    • 1994
  • 원격 측정 방법은 지표로부터 방출된 방사선의 관측으로부터 지표면의 특성을 추정하는데 기초를 두고 있으며 이 방법을 사용하여 연구되어지는 수문학적 인자에는 지표면 온도, 증발산, 토양 함수비, 강우 그리고 강설 등이 있다. 본 연구에서는 관측된 광명온도와 모의된 광명온도로부터 피복이 안된 토양의 함수비 산정에 대한 방법을 소개한다. 피복이 안된 토양에서의 초단파 방출은 함수비, 토양의 온도와 표면 조도에 의존하게 된다. 이 방법은 표면 조도의 영향을 고려하기 위한 Fresnel 반사 계수의 수정과 함께 방사선 전달 모델(radiative transfer model)에 기본을 두고 있는데 피복이 안된 매끈한 표면과 서로 다른 표면 조도를 가진 표면에 대해 분석을 실시한다. 연구의 결과는 표면 조도의 영향이 토양의 광명온도를 증가시키고 광명온도와 함수비 사이의 감소경사를 작게함을 보여주고 있다.

  • PDF

Sensing Technology for Rapid Detection of Phosphorus in Water: A Review

  • Islam, Sumaiya;Reza, Md Nasim;Jeong, Jin-Tae;Lee, Kyeong-Hwan
    • Journal of Biosystems Engineering
    • /
    • 제41권2호
    • /
    • pp.138-144
    • /
    • 2016
  • Purpose: Phosphorus is an essential element for water quality control. Excessive amounts of phosphorus causes algal bloom in water, which leads to eutrophication and a decline in water quality. It is necessary to maintain the optimum amount of phosphorus present. During the last decades, various studies have been conducted to determine phosphorus content in water. In this study, we present a comprehensive overview of colorimetric, electrochemical, fluorescence, microfluidic, and remote sensing technologies for the measurement of phosphorus in water, along with their working principles and limitations. Results: The colorimetric techniques determine the concentration of phosphorus through the use of color-generating reagents. This is specific to a single chemical species and inexpensive to use. The electrochemical techniques operate by using a reaction of the analyte of interest to generate an electrical signal that is proportional to the sample analyte concentration. They show a good linear output, good repeatability, and a high detection capacity. The fluorescence technique is a kind of spectroscopic analysis method. The particles in the sample are excited by irradiation at a specific wavelength, emitting radiation of a different wavelength. It is possible to use this for quantitative and qualitative analysis of the target analyte. The microfluidic techniques incorporate several features to control chemical reactions in a micro device of low sample volume and reagent consumption. They are cheap and rapid methods for the detection of phosphorus in water. The remote sensing technique analyzes the sample for the target analyte using an optical technique, but without direct contact. It can cover a wider area than the other techniques mentioned in this review. Conclusion: It is concluded that the sensing technologies reviewed in this study are promising for rapid detection of phosphorus in water. The measurement range and sensitivity of the sensors have been greatly improved recently.

OPTICAL PROPERTIES OF ASIAN DUST ESTIMATED FROM GROUND BASED POLARIZATION MEASUREMENTS

  • KUSAKA Takashi;NISHISAKA Tomoya
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.385-387
    • /
    • 2005
  • Polarimetric measurements of the sky radiation by the PSR-I000, which is the multi-spectral polarimeter developed by the Opt Research Corporation and has the same wavelength regions (443nm, 490nm, 565nm, 670nm, 765nm and 865nm) as the ADEOSII/POLDER sensor, have been carried out at the ground station in Kanazawa city, Japan from March to May. First of all, the wavelength dependency of degrees of polarization is examined and it is shown that degrees of polarization measured under the hazy dust cloud are lower than those measured in the clear sky and decrease as the wavelength increases. Next, a new method for estimating optical properties, such as the optical thickness, the number size distribution and the refractive index, of the Asian dust and the ground reflectance from degrees of polarization measured by PSR-I000 is described. Finally, this method is applied to polarization data acquired on April 15,2002. As a result, it is shown that our estimation algorithm provides a good result.

  • PDF

Derivation of the Ambient Nitrogen Dioxide Mixing Ratio over a Traffic Road Site Based on Simultaneous Measurements Using a Ground-based UV Scanning Spectrograph

  • Lee, Han-Lim;Noh, Young-Min;Ryu, Jae-Yong;Hwang, Jung-Bae;Won, Yong-Gwan
    • Journal of the Optical Society of Korea
    • /
    • 제15권1호
    • /
    • pp.96-102
    • /
    • 2011
  • Simultaneous measurements using a scanning spectrograph system and transmissometer were performed for the first time over an urban site in Gwangju, Korea, to derive the ambient $NO_2$ volume mixing ratio. The differential slant column densities retrieved from the scanning spectrograph system were converted to volume mixing ratios using the light traveling distance along the scanning line of sight derived from the transmissometer light extinction coefficients. To assess the performance of this system, we compared the derived $NO_2$ volume mixing ratios with those measured by an in situ chemiluminescence monitor under various atmospheric conditions. For a cloudless atmosphere, the linear correlation coefficient (R) between the two data sets (i.e., data derived from the scanning spectrograph and from the in situ monitor) was 0.81; the value for a cloudy atmosphere was 0.69. The two sets of $NO_2$ volume mixing ratios were also compared for various wind speeds. We also consider the measurement errors, as estimated from an error propagation analysis.

POST-LAUNCH RADIOMETRIC CALIBRATION OF KOMPSAT2 HIGH RESOLUTION IMAGE

  • Yoon, Jong-Suk;Lee, Kyu-Sung;Chi, Jun-Hwa;Lee, Dong-Han
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.402-405
    • /
    • 2006
  • Radiometric calibration of optical image data is necessary to convert raw digital number (DN) value of each pixel into a physically meaningful measurement (radiance). To extract rather quantitative information regarding biophysical characteristics of the earth surface materials, radiometric calibration is often essential procedure. A sensor detects the radiation of sunlight interacted atmospheric constituents. Therefore, the amount of the energy reaching at the sensor is quite different from the initial amount reflected from the surface. To achieve the target reflectance after atmospheric correct, an initial step is to convert DN value to at-sensor radiance. A linear model, the simplest radiometric model, is applied to averaged spectral radiance for this conversion. This study purposes to analyze the sensitivity of several factors affecting on radiance for carrying out absolute radiometric calibration of panchromatic images from KOMPSAT2 launched at July, 2006. MODTRAN is used to calculate radiance at sensor and reflectance of target is measured by a portable spectro-radiometer at the same time the satellite is passing the target for the radiometric calibration. As using different contents of materials composing of atmosphere, the differences of radiance are investigated. Because the spectral sensitivity of panchromatic images of KOMPSAT2 ranges from 500 to 900 nm, the materials causing scattering in visible range are mainly considered to analyze the sensitivity. According to the verified sensitivity, direct measurement can be recommenced for absolute radiometric calibration.

  • PDF

자궁경부암의 강내치료를 위한 선량측정 (Dose Distribution&Calibration in HDR Intracavitary Irradiation for Uterine Cervical Cancer)

  • 김진기;김정수;김형진;권형철
    • 한국의학물리학회지:의학물리
    • /
    • 제6권1호
    • /
    • pp.13-18
    • /
    • 1995
  • 고선량의 RALS(Remote Afterloding Syetem)를 이용한 근접조사에서 선원의 위치에 따라 선량분포는 거리제곱의 반비례 형태로 변화되므로, 관심점의 흡수선량은 선원의 교정에 의해 크게 영향을 받는다. 자궁경부암 강내치료시 정확한 흡수선량을 결정하고자 선원을 교정하고, 선원의 위치에 따른 선량분포도에 의한 계산값과 반도체 검출기와 전리함을 이용한 설측값과 차이를 비교하고 보정 방법을 논의 하였다. Bulcher-RALS를 이용하여 치료에 사용된 선원의 교정은 공기커마와 사각형 아크랄 팬톰을 이용하여 r 인자에 의한 거리 역자승법칙으로 계산하였고, Co-60 선원의 8cm 거리에서 검교정된 측정기를 이용한 선량율을 비교치로 이용하였다. 선량측정치의 재현성은 팬톰내에서 0.3~1.1% 였으며, 측정치의 분포는 Bulcher-RALS 선량분포도에 의한 계산값과 팬톰측정치의 비교에서 -3~17%, 강내치료를 받은 18 명의 환자를 대상으로한 직장내 흡수선량에서 체내 실측값과 차이는 환자와 선원의 위치에 따라 -6~+21%로 측정값이 평균 6.3% 높게 나타났다.

  • PDF

다목적 실용위성 1호 탑재 센서의 특성 (Characteristics of Remote Sensors on KOMPSAT-I)

  • 조영민;백홍렬
    • 대한원격탐사학회지
    • /
    • 제12권1호
    • /
    • pp.1-16
    • /
    • 1996
  • 한국항공우주연구소 총괄주관하에 개발 중인 다목적 실용위성(KOMPSAT) 1호기는 지도 제작, 해양관측, 우주과학실험에 활용할 지구저궤도용 실용위성으로서 고해상도 전자광학 카메라 (Electro-Optical Camera: ECO), 해양관측카메라(Ocean Color Images: OCI), 과학실험 탑재체 (Space Physics Sensor: SPS)를 탑재한다. 다목적 실용위성 1호기는 무게 약 500kg의 위성으로 고도 685km의 태양동기궤도에서 궤도주기 98분과 재방문 주기 28일을 갖는다. 본 위성은 1999년 8-9월 발사 예정이며 최소 3년의 궤도 수명을 갖는다. EOC는 한반도 표준 지도 제작을 위한 위 성영상정보 획득의 임무를 가지며, 가시광선 영역의 관측 파장 대역 510-730nm으로 주어지는 흑 백 단일 채널을 통해 수직촬영시 지상해상도 6.6m와 최소 15km 이상의 지상관측폭을 갖고 push-broom방식으로 한 궤도당 800km의 지상 길이를 촬영한다. OCI의 임무는 생물학적 해양지 리학 연구를 위한 전세계 해표면 색깔 관측이다. OCI는 다중 스펙트랄 영상 카메라로서 whisk-broom방식을 사용하여 지상관측폭 800km이내에서 1km 이하의 지상해상도를 갖는 6가지 색의 해표면 영상을 만들어낸다. OCI는 중심 파장이 443, 490, 510, 555, 670, 865nm인 6개의 관측 파장대역을 수시로 선정할 수 있다. SPS는 고에너지 입자 검출기(High Energy Particle Detector: HEPD)와 이온 측정기 (Ionosphere Measurement Sensor: IMS)로 구성된다. HEPD는 저고도 우 주 공간의 방사선입자 측정을 수행하며 이를 통해 우주방사선이 전자회로에 미치는 영향을 연구 할 수 있으며, IMS는 지구 이온층의 전자 밀도와 전자 온도 측정을 통해 KOMPSAT 궤도상의 이온층의 전지구적 특성 조사에 이용된다.

CAGEX 관측자료를 이용한 LOWTRAN7의 대기 복사전달 모의에 대한 조사 (Study on the LOWTRAN7 Simulation of the Atmospheric Radiative Transfer Using CAGEX Data.)

  • 장광미;권태영;박경윤
    • 대한원격탐사학회지
    • /
    • 제13권2호
    • /
    • pp.99-120
    • /
    • 1997
  • 위성 탐사 지구 관측 자료, 특히 가시광선 영역의 자료는 태양광이 지구 대기계와 복잡 한 상호 작용을 거친후 위성센서에 의해서 감지되어 수집된 것이다. 따라서 가시광선 영역의 지 구 관측 위성 자료를 정량적으로 분석하기 위해서는 대기의 산란과 흡수에 의한 대기효과에 대한 정량적 보정이 필요하다. 본 연구에서는 대기효과에 대한 정량적 보정을 위해서 복사 전달 모델 의 활용 가능성을 조사하였다. 이를 위해 위성 원격탐사 응용 분야에 이용되고 있는 복사 전달 모델 중의 하나인 LOWTRAN7의 복사 전달 모의 결과 중 단파 자료를 복사 관측 자료인 CAGEX 자료와 비교하였다. CAGEX 관측 자료는 대기복사 모델의 검정을 위하여 NASA Langley Research Center에서 수집한 자료로써, 1)대기 sounding, aerosols, 구름의 특성 자료, 2) 지구복사계, 직달일사계, 차광전천일사계에 의해 측정된 ARM(Aerosol Radiation Measurement) 자료, 3)Fu-Luio 모델에 의해 모의된 장파, 단파 flux 등의 자료로 구성되어 있다. 대기복사 전달 모의를 위하여 에어로졸의 광학적 특성은 CAGEX의 column optical depth, Spinhime의 산란 계 수 수직 분포와 D' Almeida의 에어로졸 복사 특성 값으로부터 도출되었다. LOWTRAN7의 복사 모의는 완전히 맑은 날에 해당하는 31개의 경우에 대하여 수행되었으며, 이 모의 결과 중 단파영 역에서의 지표면에서의 상향복사와 지표면으로의 하향직달복사 및 하향 확산 복사 그리고 대기 상단에서의 상향 복사를 CAGEX 관측 자료와 각각 비교 하였다. 비교 결과 CAGEX 자료에 대한 LOWTRAN7 결과의 표준 오차는 지표면에서의 하향 확산 복사(6.9%)를 제외한 모든 복사 항목 들이 5%이내였다. 이 결과로 보아 하향 확산 복사항의 오차가 가장 크며 이 오차가 관련된 나머 지 항목의 오차를 일으키는 역할을 하는 것으로 추측할 수 있다. 결론적으로 지표면에서의 하향 확산 복사 항목은 에어로졸에 의해 생기는 항목이므로 향후 복사 모델을 고려할 때 에어로졸의 산란에 의한 부분이 더 고려 된다면 복사 전달 모델을 이용하여 정량적으로 대기 효과를 보정하 는데 오차를 줄일 수 있을 것으로 기대된다.

선형가속기의 6 MV X-선에 대한 소형 조사면 측정과 몬테 카를로 시뮬레이션 (Measurement and Monte Carlo Simulation of 6 MV X-rays for Small Radiation Fields)

  • 정동혁;이정옥;강정구;김수곤;김승곤;문성록
    • Radiation Oncology Journal
    • /
    • 제16권2호
    • /
    • pp.195-202
    • /
    • 1998
  • 목적 : 방사선수술의 치료계획에 필요한 기본자료를 얻기 위하여, 6 MV X-선의 소형 조사면을 측정하고, 동일 조사면에 대한 몬테칼로 계산을 수행하여 그 결과를 측정한 자료와 비교하였다. 재료 및 방법 : 연구에 사용한 조사면은 SSD 100 cm에서 직경 1.0, 2.0, 그리고 3.0 cm인 원형의 소형 조사면이며, 각 조사면에 대한 심부선량백분율 (PDD)과 빔측면도 (Beam profile)를 구하였다. 측정에는 소형 반도체검출기, 물팬텀 그리고 원격조정 장치를 이용하였다. 몬테칼로 계산은 EGS4를 이용하여 수행하였으며, 계산에는 6 MV X-선의 에너지 분포와 확산빔 (divergent beam), 원형 조사면 그리고 물팬텀을 고려하였다. 결과 : 심부선량백분율의 경우, 계산값은 측정간에 비하여 낮은 경향을 보였으며, 모든 조사면에 대하여 물팬텀속 깊이 2.0-20.0 cm에서 차이는 0.3-5.7%의 범위로 평가 되었고, 표면 영역에서는 0.0-8.9%로 나타났다. 물팬텀속 깊이 10.0 cm에서 90% 선량폭은 몬테칼로 계산과 잘 일치하였으나, 반음영의 계산값은 모든 조사면에 대하여 측정값보다 0.1 cm 작게 나타났다. 결론 : 측정한 소형 조사면에 대한 심부선량백분율과 빔측면도는 몬테칼로 계산과 근사적으로 일치하였다. 팬텀 표면영역과 반음영 영역에서 측정값과 계산값의 차이가 많이 발생하였으며, 이러한 이유는 몬테칼로 계산 수행시 단순한 기하구조를 가정했기 때문이다. 따라서 실제의 기하구조와 조사면에 대한 보다 정확한 자료를 적용 할 수 있도록, 지속적인 연구를 해야 할 것이며, 몬테칼로 계산은 측정과 검증이 어려운 경우에 대하여 정확한 정보를 얻을 수 있는 유용한 도구로서 많이 이용 될 것이다

  • PDF