• 제목/요약/키워드: a remote radiation measurement

검색결과 39건 처리시간 0.026초

원전 이동감시 및 방사선 측정용 원격조종 로봇 개발 (Development of a remote controlled mobile robot system for monitoring nuclear power plant)

  • 구관모;이범희;우희곤
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.511-515
    • /
    • 1996
  • A remote controlled mobile robot system has been developed and tested to monitor the radiation area in the nuclear power plant. The mobile robot system operates according to car-driving-like commands and is capable of radiation measurement and visual inspection in unmanned situations under radiation. The robot system is equipped with a radiation sensor and two cameras with appropriate illumination set-ups. The camera with auto-focus function and 8-times zoom lens is mounted on the pan/tilt rotational base and the other is mounted on the front panel of the robot system. All commands regarding the motion of the mobile robot and various sensors are given through the monitoring system which is designed to provide an integrated man-machine interface.

  • PDF

무인 원격 방사선 검출 모듈 개발 (Development of Unmanned Remote Radiation Detection Module)

  • 장보석
    • 한국방사선학회논문지
    • /
    • 제15권6호
    • /
    • pp.795-801
    • /
    • 2021
  • 원전 해체 작업장의 요구에 따라 드론 기반 무인 원격 방사선 검출 모듈을 개발하였다. 사람이 접근해서 방사선을 측정할 수 없는 원자력 발전소 격납용기 내부 상공 및 외부로 누설되는 방사선 측정을 위한 목적으로 저준위에 민감한 GM-tube를 사용하여 제작하였다. 드론 기반 방사선 검출 모듈의 무게는 200g 미만으로 원자력 발전소 격납용기 내부의 상공과 외부 공중에서도 운용이 가능하다. 설계된 장비의 성능 확인을 위해 국제 기준 (IEC60864)을 참고하여 성능평가 실험을 시행하였다. 현장의 요구에 맞게 설계된 방사선 검출 모듈의 안정성은 측정 정확도를 평가하기 위한 변동률 실험에서 반복 측정에 의한 통계적 변동률은 ±4.6%. 선량률 의존성을 평가하기 위한 선형성 실험에서 정확도 ± 7.3%, 전체 선형도는 ± 3.5%이며 성능평가를 위한 국제기준을 만족하였다. 본 연구에서 개발한 무인 원격 방사선 검출 모듈은 원전 해체 작업장 맞춤형 장비로, 방사선 분진이 많은 현장에서 정확한 공간선량률의 측정과 방사선 작업장 안전관리에 도움을 줄 수 있을 것으로 확신한다.

극한환경 원격조작을 위한 거리측정시스템 개발 (A noncontact distance and dimension measurement system for remote handling in hostile environment)

  • 정우태;이재설;박현수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.602-607
    • /
    • 1990
  • Spent nuclear fuel is very dangerous substance emitting strong ionizing radiation which is harmful to human body. The remote handling of spent nuclear fuel is essential because people cannot access this substance without protecting radiation. To handle highly radioactive material or nuclear waste, many kinds of teleoperators such as master slave manipulator, electro mechanical manipulator, servo manipulator, mobile robot was developed. The distance and dimension of target object cannot be measured easily when highly radioactive material is handled by teleoperator because one should use lead glass or TV camera and monitor to protect radiation and see target object. During experiments on the remote handling of spent nuclear fuel by electro mechanical manipulator, we often felt that a distance and dimension measurement system is necessary to handle the objects which is in the highly radioactive environment, so we developed a system which is appropriate for this purpose.

  • PDF

인터넷을 통한 방사선 측정 원격 제어 실험실 개발 (Development of Remote Control Laboratory for Radiation. Detection via Internet)

  • 박상태;이희복;육근철
    • Journal of Radiation Protection and Research
    • /
    • 제27권1호
    • /
    • pp.59-66
    • /
    • 2002
  • 과학 교육에 있어서 실험의 역할은 자연 현상과 그와 관련된 원리를 이해하는데 필수적이다. 따라서, 인터넷을 통한 원격 제어 실험은 원격으로 과학 교육을 가르치기 위한 중요한 해법 중의 하나이다. 원격 실험은 오랜 시간이 걸리는 실험뿐만 아니라, 원격지 사람들끼리 협동을 통한 실험, 피교육자들이 접하기 힘든 고가의 장비가 필요한 실험, 절차가 위험한 실험 등에 적합하다. 본 연구에서는, 인터넷과 인터페이스 기술을 사용하여 원격으로 실험실 장비를 제적하는 일반적인 방법을 개발하였다. 인터넷을 통하여 사용자들은 원격으로 실제 장비를 제어하고 실험을 함으로써 핵물리를 배우게 된다. 본 연구에서는 원격실험의 응용 예로써 방사선 측정 시스템을 구성하였다. 본 연구의 결과를 원자력 발전소 주변 환경방사선 모니터링 시스템에 적용할 경우, 모니터링 값에 대한 신뢰도를 높일 수 있을 것으로 기대된다.

중성자, 감마선, 엑스선 방사선 측정 및 통합 제어 시스템 개발 (Development of Neutron, Gamma ray, X-ray Radiation Measurement and Integrated Control System)

  • 고태영;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제21권4호
    • /
    • pp.408-411
    • /
    • 2017
  • 본 논문에서는 중성자, 감마선, 엑스선 등의 방사선을 측정하는 통합 제어 시스템을 제안한다. 제안하는 시스템은 원격 또는 네트워크상으로 측정 및 분석한 데이터를 디스플레이를 통해 모니터링 및 제어할 수 있는 장비로서, 현장에 가지 않고도 시스템 각 구성 부분의 상태를 보고 변경하여 원격으로 감시 및 관리할 수 있다. 제안하는 시스템은 감마선/엑스선 센서부, 중성자 센서부, 주제어 임베디드 시스템부, 전용 디스플레이 장치 및 GUI부, 원격 UI부 등으로 구성된다. 감마선/엑스선 센서부는 NaI(Tl) Scintillation Detector를 사용하여 저준위의 감마선 및 엑스선을 측정한다. 중성자 센서부는 Proportional Counter Detector(저준위 중성자)와 Ion Chamber Type Detector(고준위 중성자)를 사용하여 중성자를 측정한다. 주제어 임베디드 시스템부는 방사선을 검출하여 초단위로 샘플링하고 누적된 펄스 및 전류값에 대한 방사선량으로 변환한다. 전용 디스플레이 장치 및 GUI부는 방사선 측정 결과와 변환된 방사선량 및 방사능량 측정 수치를 출력하고, 사용자에게 제어 조건 설정 및 검출부에 대한 캘리브레이션 기능을 제공한다. 원격 UI부는 측정된 값들을 취합, 저장하여 원격 감시 시스템에 전달한다. 제안된 시스템의 성능을 평가하기 위하여 공인시험기관에서 실험한 결과는 중성자 검출부는 ${\pm}8.2%$ 이하의 측정 불확도가 측정되었고, 감마선, 엑스선 검출부는 7.5%이하의 불확도가 측정되어 국제 표준인 ${\pm}15%$ 이하에서 정상동작 됨이 확인되었다.

Development of underwater 3D shape measurement system with improved radiation tolerance

  • Kim, Taewon;Choi, Youngsoo;Ko, Yun-ho
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1189-1198
    • /
    • 2021
  • When performing remote tasks using robots in nuclear power plants, a 3D shape measurement system is advantageous in improving the efficiency of remote operations by easily identifying the current state of the target object for example, size, shape, and distance information. Nuclear power plants have high-radiation and underwater environments therefore the electronic parts that comprise 3D shape measurement systems are prone to degradation and thus cannot be used for a long period of time. Also, given the refraction caused by a medium change in the underwater environment, optical design constraints and calibration methods for them are required. The present study proposed a method for developing an underwater 3D shape measurement system with improved radiation tolerance, which is composed of commercial electric parts and a stereo camera while being capable of easily and readily correcting underwater refraction. In an effort to improve its radiation tolerance, the number of parts that are exposed to a radiation environment was minimized to include only necessary components, such as a line beam laser, a motor to rotate the line beam laser, and a stereo camera. Given that a signal processing circuit and control circuit of the camera is susceptible to radiation, an image sensor and lens of the camera were separated from its main body to improve radiation tolerance. The prototype developed in the present study was made of commercial electric parts, and thus it was possible to improve the overall radiation tolerance at a relatively low cost. Also, it was easy to manufacture because there are few constraints for optical design.

Development of a real-time mobile gamma-ray measurement system for shipboard use

  • Chang-Jong Kim;Mee Jang;Hyuncheol Kim;Jong-Myoung Lim;Wanno Lee;Gyu-Seong Cho
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4077-4082
    • /
    • 2023
  • Large areas must be rapidly screened to monitor radiation in marine environments. For this purpose, this study developed a mobile real-time gamma-ray measurement system for shipboard use and evaluated its performance. The system was developed to measure engine or generator cooling water by installing a canister inside the ship. The minimum detectable activity of the system is about 0.8 Bq/L for a 60 s measurement period, and real-time data transmission and remote control are possible. The system was tested in the field and is currently being installed and operated on ships in service. Such a ship-based real-time gamma-radiation measurement system is suitable for a wide range of marine radiation surveillance applications and is expected to be rapidly deployed.

방사선 분포 모니터링 시스템 (Radiation level distribution monitoring system)

  • 최영수;박순용;이종민
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.828-831
    • /
    • 1996
  • Radiation monitoring system is needed at nuclear power plant and nuclear facility. Manual survey techniques are commonly used, but they are time consuming and somewhat inaccurate. Automatic radiation surveys are very important because it provides significant savings in men-rem and wages. Unmanned, remote automatic radiation measurement system should be small and light-weighted in order to mount on robotic system. The system we have developed consists of detection parts, signal processing part, interface, and software part. Position information is provided by using of a collimator. The measurement process is achieved by the scanning of detector and image processing techniques are used to display radiation levels. We designed collimators, detectors, signal processing circuit, and constructed prototype system. The goal of this system is the mapping of camera image and radiation level distribution.

  • PDF

USING MODIS DATA TO ESTIMATE THE SURFACE HEAT FLUXES OVER TAIWAN'S CHIAYI PLAIN

  • Ho, Han-Chieh;Liou, Yuei-An;Wang, Chuan-Sheng
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2008년도 International Symposium on Remote Sensing
    • /
    • pp.317-319
    • /
    • 2008
  • Traditionally, it is measured by using basin or empirical formula with meteorology data, while it does not represent the evaportransporation over a regional area. With the advent of improved remote sensing technology, it becomes feasible to assess the ET over a regional scale. Firstly, the IMAGINE ATCOR atmospheric module is used to preprocess for the MODIS imagery. Then MODIS satellite images which have been corrected by radiation and geometry in conjunction with the in-situ surface meteorological measurement are used to estimate the surface heat fluxes such as soil heat flux, sensible heat flux, and latent heat flux. In addition, the correlation coefficient between the derived latent heat and the in-situ measurement is found to be over 0.76. In the future, we will continue to monitor the surface heat fluxes of paddy rice field in Chiayi area.

  • PDF

무인자동 일사측정시스템의 개발 및 독도에서의 성능평가 (The Un-Manned Automated Weather(Insolation) Station at the Island "Dok-do")

  • 이태규;조서현;조덕기;오정무
    • 태양에너지
    • /
    • 제11권3호
    • /
    • pp.3-8
    • /
    • 1991
  • 우리나라의 오지 또는 섬 등지에 태양에너지 이용기기의 설치는 대체에너지 이용차원에서도 실현되어야 할 분야이다. 이러한 태양에너지 이용기기의 설계를 위한 필수자료는 신뢰성있는 일사량의 측정 및 그의 분석이다. 그러나 국내에는 15개 지역에 일사량을 측정할 수 있는 시스템이 설치되어 있지만 전력수급이 쉽지 않은 오지에서의 정확한 일사자원의 평가는 불가능하다. 따라서 본 연구를 통하여 무인자동일사량 측정시스템(KIER 시스템)을 개발하여 기존의 HWS 시스템과 같이 우리나라의 독도에 설치하여 그 성능을 비교하였다. 그 결과 절대오차가 3% 내외로 신뢰도가 높았으며, 1989년 10월부터 8개월 동안의 전 일사량의 평균치는 약 $2,330W/m^2$ day로 독도에서 태양에너지 이용시스템의 설치 및 활용가능성이 높은 것을 알 수 있었다. 본 KIER 시스템은 앞으로 독도 이외의 오지지역에도 설치를 추진할 예정이다.

  • PDF