• Title/Summary/Keyword: a relay control

Search Result 414, Processing Time 0.023 seconds

Development of Ground Fault Protective Relaying Schemes for DC Traction Power Supply System (DC 급전시스템의 지락보호계전시스템 개발)

  • Chung Sang-Gi;Jeong Rag-Gyo;Cho Hong-Sik;Lee Ahn-Ho;Kwon Sam-Young
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.9
    • /
    • pp.427-433
    • /
    • 2005
  • In DC tracking power supply system, ground faults are currently detected by the potential relay, 64P. Though 64P relay detects ground fault, it cannot Identify the faulted region which causes long traffic delays and safety problem to passengers. Two new ground fault protective relay schemes that can identify the faulted region are presented in this paper. One is bus differential protective relay and the other is ground overcurrent protective relay. Both type of relays is similar in principle to the ordinary bus differential protective relay and the ground overcurrent relay used in other power system. In DC traction power supply system, since it is ungrounded, ground fault current is not big enough to operate those relays. To solve the problem, a current control device, called device 'X', is newly introduced in both system, which enables large amount of ground fault current flow upon the positive line to ground fault. Algorithms for these relays are developed and their validity are verified by EMTP simulation.

A Study on Design of Digital Protective Relay for Transformer Using a DSP (DSP를 이용한 변압기용 디지털 보호계전기 설계에 관한 연구)

  • 서희석;권기백
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.39-46
    • /
    • 2003
  • In this papers, We studied system requirement specification, hardware design and implementation, protective algorithm and software design method to implement digital protective relay which has high trust and high function of protection as well as control and metering for power transformers. Protective relay for transformer is implemented on real time using DSP, which is the specific processor for digital signal processing, as a result, it is completed by the wide improvement of arithmetic capability of protective relay. Reliability is proved testing operating value and operating time, reset value and reset time of an relaying element using protective relay tester made in NF Corporation of Japan.

A Study on the Optimal Wireless Resource Allocation for the Access and Relay Zones of Downlink in a 2-hop Cellular Relay System based on IEEE802.16j (IEEE802.16j 기반의 2-홉 셀룰러 중계시스템에서 하향링크 접근영역과 중계영역에 대한 최적 무선자원 할당방법 연구)

  • Lee, In-Hwan;Kim, Se-Jin;Cho, Sung-Ho
    • Journal of Internet Computing and Services
    • /
    • v.11 no.3
    • /
    • pp.43-51
    • /
    • 2010
  • In this paper, we evaluate the system throughput and the method of optimal wireless resource allocation for the access zone (AZ) and relay zone (RZ) in downlink when the cell coverage is extended using the non-transparent Relay Station (RS) in a 2-hop cellular relay system based on IEEE802.16j, which uses the OFDMA-TDD structure. For the analyses, we first introduce the MAC (Media Access Control) frame structure in the non-transparent mode, then we investigate the interfering elements in both AZ and RZ for the network devices such as the Mobile Station (MS) and RS. Through computer simulation, we analyze the cell coverage extension and system throughput in terms of the distance between Base Station (BS) and RS, then we present the amount of the optimal allocation of wireless resource for the AZ and RZ in downlink using our results.

A Reporting Interval Adaptive, Sensor Control Platform for Energy-saving Data Gathering in Wireless Sensor Networks

  • Choi, Wook;Lee, Yong;Kim, Sang-Chul
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.5 no.2
    • /
    • pp.247-268
    • /
    • 2011
  • Due to the application-specific nature of wireless sensor networks, the sensitivity to such a requirement as data reporting interval varies according to the type of application. Such considerations require an application-specific, parameter tuning paradigm allowing us to maximize energy conservation prolonging the operational network lifetime. In this paper, we propose a reporting interval adaptive, sensor control platform for energy-saving data gathering in wireless sensor networks. The ultimate goal is to extend the network lifetime by providing sensors with high adaptability to application-dependent or time-varying, reporting interval requirements. The proposed sensor control platform is based upon a two phase clustering (TPC) scheme which constructs two types of links within each cluster - namely, direct link and relay link. The direct links are used for control and time-critical, sensed data forwarding while the relay links are used only for multi-hop data reporting. Sensors opportunistically use the energy-saving relay link depending on the user reporting, interval constraint. We present factors that should be considered in deciding the total number of relay links and how sensors are scheduled for sensed data forwarding within a cluster for a given reporting interval and link quality. Simulation and implementation studies demonstrate that the proposed sensor control platform can help individual sensors save a significant amount of energy in reporting data, particularly in dense sensor networks. Such saving can be realized by the adaptability of the sensor to the reporting interval requirements.

A Study on the Fault Diagnoais of Protected Facility using Relay Information (보호계전기 정보를 이용한 피보호 설비의 고장진단에 관한 연구)

  • Lee, Tae-Young;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.151-153
    • /
    • 2002
  • This paper proposes a concept for fault diagnosis system based on the relay coordination to deal with unavoidable uncertainties imposed on fault dignosis of substation. This system uses information on the relay setting values and tripped data to identify the faulted element of power system. The proposed concept will be very useful and efficient for substation and control center operator.

  • PDF

Performance Analysis of Dual-Hop MBST-ADF Relay Networks Over Quasi-Static Rayleigh Fading Channels

  • Kim, Min-Chan;Lim, Sungmook;Ko, Kyunbyoung
    • International Journal of Contents
    • /
    • v.14 no.1
    • /
    • pp.18-27
    • /
    • 2018
  • The objective of this study was to derive approximate closed-form error rates for M-ary burst symbol transmission (MBST) of dual-hop adaptive decode-and-forward (ADF) cooperative relay systems over quasi-static Rayleigh fading channels. Within a burst, there are pilot symbols and data symbols. Pilot symbols are used for channel estimation schemes and each relay node's transmission mode selection schemes. At first, our focus was on ADF relay systems' error-events at relay nodes. Each event's occurrence probability and probability density function (PDF) were then derived. With error-event based approach, we derived a tractable form of PDF for combined signal-to-noise ratio (SNR). Averaged error rates were then derived as approximate expressions for arbitrary link SNR with different modulation orders and numbers of relays. Its accuracy was verified by comparison with simulation results.

Approximated Outage Probability for ADF Relay Systems with Burst MPSK and MQAM Symbol Transmission

  • Ko, Kyunbyoung;Lim, Sungmook
    • International Journal of Contents
    • /
    • v.11 no.1
    • /
    • pp.7-14
    • /
    • 2015
  • In this paper, we derive the outage probability for M-ary phase shifting keying (MPSK) and M-ary quadrature amplitude modulation (MQAM) burst transmission (BT) of adaptive decode-and-forward (ADF) cooperative relay systems over quasi-static Rayleigh fading channels. Within a burst, there are pilot symbols and data symbols. Pilot symbols are used for channel estimation schemes and each relay node's transmission mode selection schemes. At first, we focus on ADF relay systems in which the probability density function (PDF) is derived on the basis of error events at relay nodes corresponding to channel estimation errors. Next, the average outage probability is derived as an approximate expression for an arbitrary link signal-to-noise ratio (SNR) for different modulation orders. Its accuracy is demonstrated by comparison with simulation results. Further, it is confirmed that BT-ADF relay systems with pilot symbol based channel estimation schemes enables to select correctly decoded relay nodes without additional signaling between relay nodes and the destination node, and it is verified that the ideal performance is achieved with small SNR loss.

Switched-voltage control of electrostatic suspension system

  • Woo, Shao-Ju;Jeon, Jong-Up;Higuchi, Toshiro
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10a
    • /
    • pp.401-404
    • /
    • 1996
  • A new method for the electrostatic suspension of disk-shaped objects is proposed which is based on a switched-voltage control scheme. It operates according to a relay feedback control and deploys only a single high-voltage power supply capable of delivering a dc voltage of positive and/or negative polarity. In addition to the unique feature that no high-voltage amplifiers are needed, this method provides a remarkable system simplification relative to conventional methods. It is shown that despite the inherent limit cycle property of relay feedback based control, an excellent performance in vibration suppression is attained due to the presence of a relatively large squeeze film damping. In this paper, the functional principle of the switched voltage control scheme, numerical analysis, stator electrode design, and a nonlinear dynamic model of the suspension system are described. Experimental results will be presented for a 4-inch silicon wafer that clearly reveal the capability of the proposed control structure to suspend the wafer stably at an airgap length of 50 .mu.m.

  • PDF

Design and Fabrication of a Digital Protection Relay for Reverse-Open Phase (디지털 역결상 보호 계전기의 설계 및 제작)

  • Kim, Woo-Hyun;Kil, Gyung-Suk;Kim, Sung-Wook
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.4
    • /
    • pp.313-319
    • /
    • 2019
  • Induction motors connected with a three-phase AC system may malfunction due to reverse phase or open phase faults. Conventional overcurrent relays and overheating relays are used to prevent such accidents; however, their drawbacks include a low response speed and false operation. Therefore, in this study, a digital relay for the reverse-open phase was designed and fabricated. This relay can detect the reverse phase and open phase faults and send a trigger signal to the control circuit. The proposed relay was developed based on a microcontroller. The detection times of the reverse phase and open phase were verified as 320ms and 80ms, respectively. Compared with conventional relays that only protect the motor from one type of fault, the proposed relay can detect both, reverse phase and open phase faults. In addition, the fault detection, identification criterion, and trigger signal patterns can be modified by programming according to the requirements of users.

Multiuser Precoding and Power Allocation with Sum Rate Matching for Full-duplex MIMO Relay (전이중 MIMO 릴레이를 위한 다중 사용자 Precoding 및 Sum Rate 정합 기반 전력 할당 기법)

  • Lee, Jong-Ho;Shin, Oh-Soon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.12C
    • /
    • pp.1020-1028
    • /
    • 2010
  • Relay has attracted great attention due to its inherent capability to extend the service coverage and combat shadowing in next generation mobile communication systems. So far, most relay technologies have been developed under the half-duplex (HD) constraint that prevents relays from transmitting and receiving at the same time. Although half-duplex relay (HDR) is easy to implement, it requires partitioning of resource for transmission and reception, reducing the whole system capacity. In this paper, we propose a multinser precoding and power control scheme with sum rate matching for a full-duplex (FD) multiple-input multiple-output (MIMO) relay. Full-duplex relay (FDR) can overcome the drawback of HDR by transmitting and receiving on the same frequency at the same time, while it is crucial to reduce the effect of self-interference that is caused by its own transmitter to its own receiver. The proposed precoding scheme cancels the self-interference of the FDR as well as to support multiuser MIMO. Moreover, we suggest a power allocation scheme for FD MIMO relay with the constraint that the sum rate of the relay's received data streams is equal to that of the relay's transmit data streams.