• 제목/요약/키워드: a pin-hole

검색결과 164건 처리시간 0.028초

펄스형 Nd:YAG 레이저를 이용한 FTO 식각에 대한 연구 (A Study on the Scribing of FTO using Pulsed Nd:YAG Laser)

  • 김희제;박성준;손민규;이동길;이경준
    • 전기학회논문지
    • /
    • 제57권8호
    • /
    • pp.1407-1411
    • /
    • 2008
  • In material processing, a laser system with optimal laser parameters has been considered to be significant. Especially, the laser scribing technology is thought to be very important for fabricating DSSC(Dye sensitized solar eel!) modules with good quality. Moreover, the $TEM_{00}$ mode laser beam is the most dominant factor to decide the IPCE(Incident photon to current conversion efficiency) characteristics. In order to get the $TEM_{00}$ mode, a pin-hole is inserted within a simple pulsed Nd:YAG laser resonator. And the spatial field distribution is measured by using three size pin-hole diameters of 2.0, 6.0mm respectively. At that moment, each case has the same laser beam energy by adjusting the discharge voltage and pps(pulse per second). From those results, it is known that the pin-hole size of 2.0mm has the perfect $TEM_{00}$ mode. In addition, at the charging voltage of 1000V, 10pps and the feeding speed of 1.11mm/sec, the SEM photo of FTO(Fluorine-doped tin oxide) thin film layers shows the best scribing trace.

방사성 물질 감시를 위한 부호화 구경 감마카메라 개발 (Development of a Coded-aperture Gamma Camera for Monitoring of Radioactive Materials)

  • 조규성;신형주;지용기;윤정현
    • Journal of Radiation Protection and Research
    • /
    • 제29권4호
    • /
    • pp.257-261
    • /
    • 2004
  • 핀홀 감마카메라의 민감도를 향상시키기 위하여 픽셀화된 CsI(Tl) 섬광체와 위치민감형 광증배관을 이용하여 부호화 구경 감마카메라를 개발하였다. Rounded-hole로 이루어진 $13{\times}11$ 픽셀구조의 개조된 uniformly reductant array (URA) 가 계측기의 공간해상도를 고려하여 부호화된 마스크로 선택되었다. 부호화된 구경 카메라와 핀홀 카메라의 성능을 비교하기 위하여 Tc-99m 소스의 여러 가지 형태를 이용하여 테스트 하였으며, 신호 대 잡음비 또는 민감도의 향상에 대한 카메라의 성능을 분석하였다. 그 결과 공간해 상도에 있어서 약간의 저하가 있었으나 영상의 질은 매우 향상되었다. 비록 카메라의 개발과 테스트가 저에너지 영역에서 이루어졌지만, 부호화 구경 카메라의 구상은 방사성 물질 감시 그리고 다른 응용들에 있어서도 효과적으로 사용되어질 수 있을 것이다.

기류형성을 위한 고전압 이온풍 발생장치와 코로나 제어기술에 관한 기초적 연구 (Investigation of the HV Ionic Wind Generator and the Control of Corona Discharge for Air-flow Formation)

  • 이복희;엄주홍;강성만;장근철;안창환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1707-1709
    • /
    • 2002
  • Ionic wind may be produced by DC corona discharges. In this work, the electrical effect has studied to evaluate applicability in fields of electrostatic cooling, ozone generation, electrostatic precipitation, heat transfer, air flow modification, and etc. The ionic wind velocity was measured as a function of the distance of pin to plate and the diameter of punched hole. The pin to punched-plate electrode generates airflow from pin to plate and the flow direction is controlled by the hole size of punched-plate, input voltage and distance between two electrodes. As a consequence, the ionic wind velocity is nearly proportional to the applied voltages and ranges from 1 to 3 m/sec.

  • PDF

풍력발전기용 3점 지지 기어박스에서 캐리어 핀홀 위치 오차가 유성기어의 하중분할에 미치는 정성적 영향에 관한 실험적 연구 (An Experimental Study for the Qualitative Effect of Carrier Pin Hole Position Error on Planet Load Sharing of Wind Turbine Three-point Suspension Gearbox)

  • 남주석;한정우
    • 한국생산제조학회지
    • /
    • 제25권2호
    • /
    • pp.97-104
    • /
    • 2016
  • In this study, the qualitative effects of the positional error of carrier pin holes on the planet load sharing characteristics of the three-point suspension gearbox of wind turbines were investigated experimentally. A 35-kW gearbox comprising two planetary gear stages and a parallel gear stage and size one-fourth of that of a 2-MW three-point suspension gearbox was used as the test gearbox. The strain gauges attached to the ring gear teeth of the input planetary gear stage were used for the purpose of this study. The applied loading conditions were 50%, 75%, and 100% of the rated torque, and the mesh load factor was used as the load sharing index. The experimental results indicated that both the magnitude and direction of the positional error of pin holes had a significant effect on the planet load sharing characteristics of the three-point suspension gearbox. In addition, an increase in the applied torque results in uniform load sharing.

통신 교환기 고밀도 접속용 탄성 압입 핀의 특성 평가 (Evaluation of Complaint Press-Fit pin for Telecommunications)

  • 신동필;정명영;홍성인
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.481-485
    • /
    • 2000
  • A new type of compliant press-fit pin has been developed and evaluated for use packaging of electronic telecommunications equipments. Main requirements for design are defined the upper limit of pin insertion force and the lower limit of pin retention force. Upper limit of pin insertion force is set to protect the copper plate of the inner PTH wall. Lower limit of pin retention force is set to satisfy a wire-wrapping specification. Results are represented by insertion force and retention force variations according to the front angle, rear angle and material, etc.

  • PDF

3상 골신티그램을 이용한 급성 일과성 활막염의 진단 (Three-Phase Bone Scintigraphic Diagnosis of Acute Transient Synovitis)

  • 정수교;이명희;김춘열;박용휘
    • 대한핵의학회지
    • /
    • 제19권1호
    • /
    • pp.73-75
    • /
    • 1985
  • Acute transient synovitis of the hip presents clinically pain and limping. But in the majority of the cases, definite positive findings are not manifest in roentgenogram in its early phase. However radionuclide bone imaging combines with the assessment of vascularization and bone tracer uptake is of great value in solving this diagnostic problem. The materials for this study consisted of 29 children with acute transient synovitis of the hip, characterized by symptoms and physical signs of an arthritis, negative X-ray findings and disappearance of all symptoms and signs within a short period of time. They were twenty males and 9 females and age ranged from 1 to 12 years. We took pelvic reontgenogram in AP and frog-leg views. After intravenous bolus injection of 10 to 15 mCi of $^{99m}Tc-methylene$ diphosphonate, 24 sequential image of the pelvis was taken at 2-second interval for blood flow study. The scintigrams were made using a gamma camera with high resolution parallel hole collimator. Blood pool imaging was obtained at 2 minutes after tracer administration. After 3 hours, static images were taken and then closeup image of the hip using pin-hole collimator was followed. The results were as follows: 1) Bone scintigram was much more sensitive than conventional roentgenogram in diagnosis of acute transient synovitis of the hip. 2) Three-phase imagings showed increased vascular activities in blood pool scintigrams in 96%. 3) Pin-hole imaging showed increased tracer uptake in the regional bones of the hip, par ticularly in the medial aspect of femoral head and acetabulum. 4) We confirmed that three-phase imaging reinforced with pin-hole technique were very useful in diagnose of acute transient synovitis of the hip.

  • PDF

PIN 다이오드 - PNP 트랜지스터 결합모델에 의한 1,700 V급 NPT 트랜치 IGBT의 해석에 관한 연구 (A Study on the 1,700 V Rated NPT Trench IGBT Analysis by PIN Diode - PNP Transistor Model)

  • 이종석;경신수;강이구;성만영
    • 한국전기전자재료학회논문지
    • /
    • 제21권10호
    • /
    • pp.889-895
    • /
    • 2008
  • This paper presents a comprehensive mathematical analysis and simulation of trench IGBT with the help of PIN-PNP combinational model. Since trench IGBT is characteristically influenced by PIN diode, it may be almost impossible to analyze the trench IGBT using PNP-MOS modeling methods, even PIN-MOS techniques which neglect the hole current components coming into p-base region. A new PIN-PNP complementary cooperational model is developed in order to make up the drawbacks of existing models. It would allow us to make qualitative analysis as well as simulation about switching and on-state characteristics of 1,700 V trench IGBT. Moreover, if we improve the PIN diode effects through the optimization of trench structure, trench IGBT is expected to be one of the most promising devices in the not only high-voltage but also high speed switching device field.

Differential gear case와 피니언 샤프트 체결을 위한 핀 압입 장치설계 및 측정에 관한 연구 (A Study on the Design and Measurement of Pin Press-Fit Device for Fastening Differential Gear Case and Pinion Shaft)

  • 장태환;권진욱;엄지현;김정아;김태규
    • 열처리공학회지
    • /
    • 제34권1호
    • /
    • pp.25-30
    • /
    • 2021
  • The differential gear system is a device designed to distribute the driving force of both vehicle wheels and control the rotational speed when the vehicle turns on a curve. The differential device consists of a differential gear case, a ring gear, and a pressure ring. A differential pinion gear and side gear are mounted on the differential pinion shaft inside the differential gear case. In this study, a pin press-fitting device that mounts the pinier gear and side gear to the differential pinion shaft in the differential gear case was designed, and a jig device for pin press-fitting using servo press was developed. In addition, by precisely measuring the pin press-in load and press-in distance according to the pin hole diameter of the differential gear shaft, the optimization of the pin pressin process was established.

R.P.I.(ring pin implant)를 응용한 치아의 재식과 이식 (Transplantation and Replantation Using R.P.I.(ring pin implant))

  • 김재철
    • 대한심미치과학회지
    • /
    • 제8권1호
    • /
    • pp.36-44
    • /
    • 1999
  • No one really doubts that the hottest area of dentistry in 21st century would most likely be 'implant'. With the support of a vast amount of research, implant has been successfully and rapidly absorbed into the field of general dentistry including private practitioners. For teeth with hopeless(or refractory) periodontitis or periapical pathosis, with no hesitation most dentists would think extraction as the sole treatment option followed by prosthodontic replacement possibly including implant. Not many dentists would take Trasplantation/Replantation as another treatment option for a particular condition. Dentistry is often more focused on 'Restoration' than 'Preservation' of natural dentition. 'Biologic Implant' is obviously much closer to the concept of 'Preservation'. Many different types of biologic implant system have been introduced to clinical dentistry so far. Many of those have failed to earn reasonable acknowledgement despite of the clinical success they brought. For some reason biologic implant has rather been alienated for long time. RPI(Ring Pin Implant) is designed to improve the prognosis and success rate of transplanted/replanted teeth. RPI is a Ti-based custom made implant system. It is fabricated either by electric casting or milling process. The major feature RPI gas is the 'ring & hole' structure. The hole should be no less than 1mm diameter to allow bone bridge formation thru it. The ring structure and bone bridge formation creates anti-torque activity, which largely increases the 'initial stability' of the transplanted/replanted teeth. It is also reported that RPI is beneficial in the aspect of resisting root resorption following replantation/transplantation procedure.

  • PDF

이중 현미경 구조를 이용한 마이크로 렌즈 및 핀홀 어레이 기반 병렬 공초점 시스템 (A Parallel Mode Confocal System using a Micro-Lens and Pinhole Array in a Dual Microscope Configuration)

  • 배상우;김민영;고국원;고경철
    • 제어로봇시스템학회논문지
    • /
    • 제19권11호
    • /
    • pp.979-983
    • /
    • 2013
  • The three-dimensional measurement method of confocal systems is a spot scanning method which has a high resolution and good illumination efficiency. However, conventional confocal systems had a weak point in that it has to perform XY axis scanning to achieve FOV (Field of View) vision through spot scanning. There are some methods to improve this problem involving the use of a galvano mirror [1], pin-hole array, etc. Therefore, in this paper we propose a method to improve a parallel mode confocal system using a micro-lens and pin-hole array in a dual microscope configuration. We made an area scan possible by using a combination MLA (Micro Lens Array) and pin-hole array, and used an objective lens to improve the light transmittance and signal-to-noise ratio. Additionally, we made it possible to change the objective lens so that it is possible to select a lens considering the reflection characteristic of the measuring object and proper magnification. We did an experiment using 5X, 2.3X objective lens, and did a calibration of height using a VLSI calibration target.