• Title/Summary/Keyword: a longitudinal case study

Search Result 326, Processing Time 0.023 seconds

Behavior Character Analysis of Super Long Suspension Bridge using GNSS (GNSS를 활용한 초장대 현수교의 거동 특성 분석)

  • Park, Je-Sung;Hong, Seunghwan;Kim, Mi-Kyeong;Kim, Tai-Hoon;Sohn, Hong-Gyoo
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.5_2
    • /
    • pp.831-840
    • /
    • 2019
  • Recently, the span length of long-span bridges is getting longer. As a result, it has been suggested that a new concept called 'super long-span bridge'. In case of super long span bridges, the structure is being complicated and the importance of structural stability is being emphasized. However, until recently, the most commonly used sensors (dual axis clinometer, anemometer, strain gauge, etc.) have got limit about the bridge monitoring. Consequently, we researched the application of a Global Navigation Satellite System (GNSS) to improve the limit of the existing sensors. In this study, the dual axis clinometer, the anemometer and the strain gauge together with the GNSS were used to analyze the behavior of a super-long suspension bridge. Also, we propose the detailed method of bridge monitoring using the GNSS. This study consisted of three steps. First step calculated the absolute coordinates of the towers and the longitudinal axis direction of the study bridge using the GNSS. In second step, through the analysis of the long-term behavior in shortly after construction, we calculated the permanent displacement and evaluated the stability of main towers. Third step analyzed the behavior of bridge by the wind direction and was numerically indicated. Consequently, the bridge measurement using the GNSS appeared that the acquired data is able to easy processing according to the analysis purpose. If we will use together the existing measurement sensors with the GNSS on the maintenance of the super long-span bridge, we figure each error of measurement data and improve the monitoring system through calibration. As a result, we acquire the accurate displacement of bridge and figure the behavior of bridge. Consequently, we identified that it is able to construct the effective monitoring system.

Psycho-Social Determinants of Subjective Well-being and Physical Health of a Retired Elders in Korea: A Longitudinal Study on the occupational classification (은퇴 노인의 주관안녕과 신체건강에 영향을 미치는 요인들: 은퇴전 직종에 따른 종단 연구)

  • Kun-Seok Park
    • Korean Journal of Culture and Social Issue
    • /
    • v.15 no.2
    • /
    • pp.291-318
    • /
    • 2009
  • The purpose of this study was to find out the impact of psycho-social factors (social relationship and personal) as well as illness history and economic status on physical health and subjective well-being among the retired Koreans elderly. Data were collected from 1,315 elders (mean age = 72.70yrs) residing in Seoul and Chuncheon regional area via interviews(Time 1), and them were re-interviewed two year later(Time 2). Multiple regression analyses indicated that the retired elders' illness history, economic status, marital satisfaction, fulfillment of self-esteem need, drinking behavior, positive affectivity, negative affectivity and physical health to predict their subjective well-being at Time 1(R2=.705). The retired elders' economic status, marital satisfaction, positive affectivity, negative affectivity and physical health to predict their subjective well-being at Time 2(R2=.418). The retired elders' illness history, economic status, expectations for one's offspring, drinking behavior and subjective well-being to predict their physical health at Time 1(R2=.364). And the retired elders' illness history, economic status, marital satisfaction, positive affectivity and negative affectivity to predict their physical health at Time 2(R2=.265). In case of retired elderly, suggested for the psycho-social determenants of subjective well-being and physical health by occupational classification. The implications of this study and the suggestions for furture study were discussed.

  • PDF

Empirical Study on Effects of Disk Shape Filler Content and Orientation on Thermal Expansion Coefficient of PP Composites (판상형 충전제의 함량과 배향에 따른 PP복합체의 열팽창계수 영향 연구)

  • Lee, Yong-Hyun;Jeoung, Sun-Kyoung;Hwang, Hyo-Yeon;Lee, Seung-Goo;Lee, Kee-Yoon
    • Polymer(Korea)
    • /
    • v.36 no.3
    • /
    • pp.281-286
    • /
    • 2012
  • Experimental study was performed regarding the effects of disc-like filler orientation and contents on the coefficient of thermal expansion (CTE) of polypropylene composites using the three dimensional ellipsoids ($a_1$ > $a_2$ > $a_3$) analyzed by two aspect ratios(${\rho}_{\alpha}=a_1/a_3$and ${\rho}_{\beta}=a_1/a_2$). Measured data were compared with the theoretical approaches proposed by Lee et al. Mica and talc were useed as disk-like fillers in the composites. As experimental results, ${\alpha}_{11}/{\alpha}_m$ decreased down to ca. 0.56 with mica content of 20 wt% and the aspect ratios, ${\rho}_{\alpha}=13.5$, ${\rho}_{\beta}=1.8$. However, ${\alpha}_{33}/{\alpha}_m$ increased to more than 1. In the case of talc, ${\alpha}_{11}/{\alpha}_m$ decreased to ca. 0.63 with 20 wt% and ${\rho}_{\alpha}=3.7$, ${\rho}_{\beta}=1.4$. Finally, the longitudinal CTEs (${\alpha}_{11}$) of polypropylene composites decreased as filler contents increased, but normal CTE (${\alpha}_{33}$) increased in the low filler contents like the theory.

Safety and Health Culture Change Stages: A Reflection on 40 years of Hearing Conservation History at a Multinational Company (일개 기업의 40년 소음으로 인한 청력 손실 예방 활동을 통해 본 청력보존문화의 변화 단계)

  • Park, Mijin;Yoon, Chungsik;Paek, Domyung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.3
    • /
    • pp.298-309
    • /
    • 2019
  • Objectives: This study aimed to investigate stages of safety and health culture change through a reflection on 40 years of hearing conservation history at a multinational company. Methods: The target workplaces were multinational companies with more than 1,000 employees. The research used the clinical case study and system analysis methods based on direct observation of the research from 1994 to 2009. The latter method performed an analysis of the equilibrium state of the cross-section in the given period and the longitudinal profile of the change during the given period. Results: The stages of cultural change are divided into five stages and summarized as follows. In the first stage, workplace noise was not widely recognized as a hazard, while in the second stage, the measurement of noise levels and audiometric testing were conducted under the Korean Occupational Safety and Health Act (KOSHA). The driving force for change in the second stage was the amendment of the KOSHA. In the third stage, noise came to be recognized as a hazard factor through awareness training. The driving force of change during the third stage was the strong executive power exerted by the audit of the industrial hygiene program from the US head office. In the fourth step, there was a change to actually reduce noise. The driving force in this stage was a change in company executives' risk perception resulting from lawsuits over noise-induced hearing loss and the task force team activities for culture change based on the action learning protocol. At the fifth stage, a 'buy quiet policy' was institutionalized. The management's experience that noise reduction was difficult was the motivation to manage noise from the time of purchase of equipment. Conclusions: The activities of a hearing conservation program are determined by the improvement of the legal system and by the way it is enforced. Noise control activities to reduce noise areas may be possible through the shared risk perception of noise-induced hearing loss and by a change agent role as a facilitator to implement noise control.

DENTIN PERMEABILITY CHANCE ACCORDING TO THE PROCESS OF COMPOMER RESTORATION (컴포머 충전과정에 따른 상아질 투과도의 변화)

  • Cho, Hye-Jin;Lee, Kyung-Ha;Lee, Se-Joon;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.4
    • /
    • pp.382-388
    • /
    • 2002
  • Compomer is composed of matrix and filler : matrix is made of the combination of resins and polycarboxylic molecules that are light-cured, and a filler is a glass component which is capable of ion-release. The resin content of compomers produces polymerization shrinkage which can adversely affect marginal adaptation. Pretreatment is a fundamental step which is treated with conditioner or primer in the use of these materials. Microleakage of restorative materials has been investigated mostly by dye penetration method. Dye penetration method was not quantitative and not measured repeatedly. Fluid filtration method, introduced and developed by Pashley's group, has been extensively used for 20 years for research purpose to understand the physiology of dentin, as well as the effects of various restorative treatments on dentin permeability. It permits quantitative, nondestructive measurment of microleakage in a longitudinal manner. The purpose of this study was to evaluate the change of dentin permeability according to the process of compomer restoration. In this study. Cl V cavities were prepared on buccal surface of thirty extracted human molars. The prepared cavities were etched by 37% phosphoric acid. The experimental teeth were randomly divided into three groups. Each group was treated with following materials Group 1 : Prime & Bond NT/Dyract AP, Group2: Single Bond/F2000 compomer, Group 3 : Syntac Single Component/Compoglass. The bonding agent and compomer were applied for each group following manufacturers information. Dentin permeability of each group was measured at each process by fluid filtration method; Step 1 : preparation(smear layer). Step 2 : etching(smear layer removal), Step 3 : applying the bonding agent, Step 4 : filling the compomer. Dentin permeability was expressed by hydraulic conductance ($\mu\textrm{l}$ min$^{-1}$cm$H_2O$$^{-1}$). The data were analysed statistically using One-way ANOVA and Sheffe's method. The results were as follows : 1. Dentin permeability differences between each process were significant except between step 1 and step 2(p<0.01). 2. Dentin permeability after removal of smear layer was highly increased(p<0.01). 3. In most case, decrease of dentin permeability was obtained by applying bonding agent(p<0.01). 4. Dentin permeability differences among the experimental groups were not significant(p>0.05). 5. None of compomers used in this study showed perfect seal at the interface.

A Theoretical Study on the FRP Retrofit of Existing Circular Bridge Piers for Seismic Performance Enhancement (기존 원형교각의 내진성능 향상을 위한 FRP 보강에 대한 이론적 연구)

  • Kwon Tae-Gyu;Choi Young-Min;Hwang Yoon-Knok;Yoon Soon-Jong
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.1 s.79
    • /
    • pp.61-69
    • /
    • 2004
  • The bridge piers under service suffered a brittle failure due to the deterioration of lap-spliced longitudinal reinforcement without developing its flexural capacity or ductility. The earthquake induced lateral force results in tension which causes bond-slip failure at the lap-spliced region in circular bridge piers. In this case, such a brittle failure can be controlled by the seismic retrofit using FRP laminated circular tube. The retrofitted piers using FRP laminated circular tube showed significant improvement in seismic performance due to FRP's confinement effect. This paper presents the analytical results on the seismic strengthening effect of circular bridge piers with poor lap-splice details and strengthened with FRP laminated circular tube. FRP's confinement effect is predicted by the classical elasticity solution for the laminated circular tube manufactured with several layers. The FRP laminated circular tube induces the flexural failure instead of a bond-slip failure of the circular reinforced concrete piers under seismic induced lateral forces. To investigate the correctness and effectiveness of analytical solution derived in this study, the analytical results were compared with the experimental data and it was confirmed that the results were correlated well each other, The effects on the confinement of FRP laminated circular tube, such as the number of layers, the fiber orientations, and the mechanical properties, were investigated. From the parametric study, it was found that the number of layers, the fiber orientations, and the major Young's modulus (E11) of the FRP laminated circular tube were the dominant parameters affecting the confinement of reinforced concrete circular bridge piers.

An Empirical Study on the Influencing Factors of Intention to Adoption of Mobile Government Service (모바일 전자정부 서비스 수용의도의 영향요인에 관한 연구)

  • Han, Kihun;Kim, Jinsoo
    • Asia pacific journal of information systems
    • /
    • v.23 no.3
    • /
    • pp.77-104
    • /
    • 2013
  • Mobile technology is accelerating innovative changes across all fields of our society as well as business environments. Especially, demands on mobile government (M-government) services have been increased gradually since e-government has improved national administration services dramatically. However, high-quality services which are acceptable to may users are not actually supplied because technical issues such as security on mobile e-government services have not solved and governance policy was not established yet. Previous studies show that most researches are devoted to technical ones or limited to theoretical exploratory study. As a result, developing useful guidelines which are practically and theoretically proved is one of the very important research issues. This study reviews the previous research works such as concept of mobile, e-government, M-government, technical trends of mobile, market situations, present status, and various case studies. And then we develop a research model with five factors, twenty four variables and seventy six measurement for measuring the influencing factors to adoption of M-government services. The model is composed of total 16 hypotheses, 22 variables, and 76 measurements. The model is analyzed by using statistical package SPSS (18.0) and AMOS (18.0) together with structural equation method based on 294 samples. The results show that the model is valid and there are statistically significant influence between ease of use and usefulness, ease of use and user's satisfactions, usefulness and intent of re-use, and user's satisfactions and intent of re-use, excepting usefulness and user's satisfaction, ease of use and intent of re-use did not affect significant influences. Especially, service quality, system quality, and relationship quality are identified as influencing factors to adaption of M-government service. The results are expected to provide a theoretical research framework which generate new research issues in M-government service area. It also can provide an useful guidelines to practical experts in successfully implementing M-government services. Further research directions are as follows. User's intents have to be studied in details by classifying users by individual, enterprise, and government as well as developing a new hypothetical model. Since M-government service is at the initial stage, longitudinal studies have to be conducted to trace the peoples' need in order to develop new high-quality mobile services.

Dynamic Response and Control of Airship with Gust (외란이 작용하는 비행선의 동적 반응 및 제어)

  • Woo, G.A.;Park, I.H.;Oh, S.J.;Cho, K.R.
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.6
    • /
    • pp.69-77
    • /
    • 2002
  • To acquire the dynamic response and design the controller of the airship, the longitudinal motion of the airship with respect to the vertical gust, which is the nonlinear system, was studied. The effects of the apparent mass and moment of the airship delay the dynamic response and the settling time, which are slower than those of conventional airplanes. The current object of the airship is designed to cruise at 500~1000m altitude. At that height, the atmospheric conditions are generally unstable by wind gust. In this paper, it has been studied for the case of vertical gust, since the apparent mass effects are dominant in has been studied for the case of vertical gust, since the apparent mass effects are dominant in that plane. In addition to the study of the dynamic responses of the airship, the controller was designed using the PID-controller. When the gust was applied, airship responses were recovered of equilibrium states. However, it takes too ling time for recovery and the speed of airship is reduced. So, the aim in this paper was to fasten the recovery speed and to get back the cruising velocity. The control parameters were determined from the stability mode analysis, and the control inputs were the thrust and the elevator deflection angle.

A study on the design of tunnel lining insulation based on measurement of temperature in tunnel (터널 온도계측을 통한 라이닝 단열 설계에 관한 연구)

  • Kim, Dea-Young;Lee, Hong-Sung;Sim, Bo-Kyoung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.4
    • /
    • pp.319-345
    • /
    • 2011
  • In case of tunnels in cold regions, a freeze of groundwater around tunnel may act as a barrier of tunnel drainage in winter, or may cause the inner extrusion of lining. In spite of that, a design of insulation for preventing the frost damage of tunnel lining has not been introduced in Korea, while foreign countries such as Norway and so on have a standard on insulation. In this study, a few freezing cases of road tunnels have been reviewed, and the results show that the freezing protection is necessary. In order to characterize the thermal distribution in the tunnel, following measurements have been performed at Hwa-ak tunnel; the temperature distribution by longitudinal lengths, the internal temperature of lining and the temperature distribution of the ground under pavement. From these measurements, the characteristics of the tunnel's internal temperature distribution due to temperature change in the air has been analyzed. Based on the measurement results on the temperature distribution at Hwa-ak tunnel, thermal flow tests on the rock specimen with and without insulation have been performed in the artificial climate chamber to investigate the performance of the insulation. Also, a number of 3D numerical analyses have been performed to propose appropriate insulation and insulation thicknesses for different conditions, which could prevent the frost damage of tunnel lining. As a result of the numerical analysis, air freezing index of 291$^{\circ}C{\cdot}$ Hr has been suggested as the threshold value for freezing criteria of groundwater behind the tunnel lining.

A study on the determination of location of the detention pond in trunk sewer for reducing runoff amounts (우수유출저감을 위한 간선저류지 위치선정에 관한 연구)

  • Lee, Sung Ho;Yoon, Sei Eui;Lee, Jae Joon
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.4
    • /
    • pp.223-232
    • /
    • 2017
  • The ability to defend against floods in urban areas was weakened, because the increase in the impervious rate of urban areas due to urbanization and industrialization and the increase in the localized torrential rainfall due to abnormal climate. In order to reduce flood damage in urban areas, various runoff reduction facilities such as detention ponds and infiltration facilities were installed. However, in the case of domestic metropolitan cities, it is difficult to secure land for the installation of storm water reduction facilities and secure the budget for improving the aged pipelines. Therefore, it is necessary to design a storage system (called the detention pond in trunk sewer) that linked the existing drainage system to improve the flood control capacity of the urban area and reduce the budget. In this study, to analyze the effect of reducing runoff amounts according to the volume of the detention pond in trunk sewer, three kinds of virtual watershed (longitudinal, middle, concentration shape) were assumed and the detention pond in trunk sewer was installed at an arbitrary location in the watershed. The volume of the detention pond in trunk sewer was set to 6 cases ($1,000m^3$, $3,000m^3$, $5,000m^3$, $10,000m^3$, $20,000m^3$, $30,000m^3$), and the installation location of the detention pond in trunk sewer was varied to 20%, 40%, 60%, and 80% of the detention pond upstream area to the total watershed area (DUAR). Also, using the results of this study, a graph of the relationship and relational equation between the volume of the detention pond in trunk sewer and the installation location is presented.