• 제목/요약/키워드: a frequency response

검색결과 4,799건 처리시간 0.041초

단자유도 건물의 지진응답제어를 위한 마찰감쇠기 설계 (Design of Friction Dampers for Seismic Response Control of a SDOF Building)

  • 민경원;성지영
    • 한국소음진동공학회논문집
    • /
    • 제20권1호
    • /
    • pp.22-28
    • /
    • 2010
  • Approximate analysis for a building installed with a friction damper is performed to get insight of its dynamic behavior. Energy balance equation is used to have a closed analytical form solution of dynamic magnification factor(DMF). It is found out that DMF is dependent on friction force ratio and resonance frequency. Approximation of DMF and equivalent damping ratio of a friction damper is proposed with such assumption that the building with a friction damper shows harmonic steady-state response and narrow banded response behavior near resonance frequency. Linear transfer function from input external force to output building displacement is suggested from the simplified DMF equation. Root mean square of a building displacement is derived under earthquake-like random excitation. Finally, design procedure of a friction damper is proposed by finding friction force corresponding to target control ratio. Numerical analysis is carried out to verify the proposed design procedure.

Nonlinear dynamic analysis of laterally loaded pile

  • Mehndiratta, S.;Sawant, V.A.;Samadhiya, N.K.
    • Structural Engineering and Mechanics
    • /
    • 제49권4호
    • /
    • pp.479-489
    • /
    • 2014
  • In the present study a parametric analysis is conducted to study the effect of pile dimension and soil properties on the nonlinear dynamic response of pile subjected to lateral sinusoidal load at the pile head. The study is conducted on soil-pile model of different pile diameter, pile length and soil modulus, and results are compared to get the effect. The soil-pile system is modelled using Finite element method. The programming is done in MATLAB. Time history analysis of model is done for varying non-dimensional frequency of load and the results are compared to get the non-dimensional frequency at which pile head displacement is maximum in each case. Maximum possible bending moment and soil-pile interacting forces for the dynamic excitation of the pile is also compared. When results are compared with the linear response, it is observed that non-dimensional frequency is reduced in nonlinear response on account of reduction in the soil stiffness due to yielding. Nonlinear response curve shows high amplitude as compared to linear response curve.

하중의 주파수에 지배받는 흙의 동적거동을 고려하는 등가선형해석방법 개발 (Development of equivalent linear algorithm procedure that accounts for the loading frequency dependent soil behavior)

  • 박두희;이현우;이승찬;김재연;천병식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.617-624
    • /
    • 2006
  • Site response analysis is widely used in estimating local seismic site effects. The soil behavior in the analysis is assumed to be Independent of the rate of the seismic loading laboratory results, however, indicate that cohesive soil behavior is greatly influenced by the rate of loading. A new equivalent linear analysis method is developed that accounts for the rate-dependence of soil behavior and used to perform a series of one dimensional site response analyses. Results indicate that while rate-dependent shear modulus has limited influence on computed site response, rate-dependent soil damping greatly filters out high frequency components of the ground motion and thus results in lower response.

  • PDF

탄소접지극 접지임피던스의 주파수의존성과 과도응답특성의 해석 (Analysis of Transient Response Behavior and Frequency-Dependent Ground Impedances of the Carbon Ground Electrodes)

  • 이복희;이강수;김유하;엄상현
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.54-61
    • /
    • 2013
  • This paper presents transient response behavior and frequency-dependent ground impedance of a single carbon ground electrode. The ground impedance of the carbon ground electrode was measured as a function of frequency of injected currents and simulated by using the distributed parameter circuit model with due regard to the frequency-dependent soil parameters, and the transient response behavior of the carbon ground electrode against impulse currents were investigated. As a consequence, the frequency-dependent ground impedance of the carbon ground electrode showed the capacitive behavior, that is, the ground impedance decreases with increasing the frequency of injected currents and lowers at the fast front time of impulse current. It was found that the carbon ground electrode is effective in grounding system for lightning protection. The ground impedance simulated with due regard to the frequency-dependent soil parameters was in good agreement with the measured data. The adequacy of the simulation technique and the distributed parameter circuit model for the carbon ground electrode was verified. It is expected that the simulation methodology, which analyzes the frequency-dependent ground impedance of the carbon ground electrode proposed in this work, can be used in the design of a grounding system for protection against lightning.

Role of Rostroventrolateral Medulla in Somatosympathetic Pressor and Depressor Response Evoked by Peripheral Nerve Stimulation

  • Jun, Jae-Yeoul;Yeum, Cheol-Ho;Goo, Yong-Sook;Kim, Jun
    • The Korean Journal of Physiology
    • /
    • 제25권2호
    • /
    • pp.201-209
    • /
    • 1991
  • The rostral ventrolateral medulla (RVLM) has been established recently as a sympathoexcitatory area. The present study was conducted to investigate whether the somatosympathetic pressor and/or depressor responses are mediated through RVLM in cats anesthetized with ${\alpha}-chloralose$. An occipital craniectomy was performed and ventrolateral medulla were stimulated either electrically or chemically to evoke changes in arterial blood pressure. And then the effect of lesions in the ventrolateral medulla on the changes in blood pressure elicited by the peripheral nerve stimulation was observed. Followings are the results obtained: 1) Pressor areas were found in the ventrolateral medulla, lateral reticular nucleus and rostral dorsal area. 2) Depressor areas were found mainly in the ventrolateral medulla rostral to the pressor areas. 3) Some areas showed biphasic responses: a depressor response to lower frequency and a pressor response to higher frequency stimulation. 4) After electrical lesion in pressor area in RVLM, the somatosympathetic pressor response was abolished or depressed markedly. The somatosympathetic depressor response, however, remained after the lesion. 5) Electrical lesion in the depressor area abolished somatosympathetic depressor response. From the above results it is concluded that somatosympathetic pressor response is mediated through RVLM, while somatosympathetic depressor response is not mediated through RVLM.

  • PDF

외부 가진력의 주파수에 따른 강제진동시스템의 특성 (Characteristics of Forced Vibration System According to the Frequency of External Exciting Force)

  • 김종도;윤문철
    • 융합정보논문지
    • /
    • 제11권9호
    • /
    • pp.130-137
    • /
    • 2021
  • 주파수를 갖는 외부 가진력에 의하여 강제 진동의 특성을 가진력의 진폭과 주파수에 따라 그 특성을 분석하였다. 변위, 속도 및 가속도를 얻기 위해 수치해석을 수행하여 주파수 응답을 얻었고 특히 주파수 영역에서 시스템 고유진동수와 가진 주파수의 발생 위치를 밝히고자 각각의 FRF의 분석을 하였다. 외부 가진에 의한 진동모델에서 변위, 속도 및 가속도의 거동과 주파수 응답함수에서 고유진동 주파수와 주변의 가진 모드 분포도 파워 스펙트럼과 실수부와 허수부의 FRF 에서 나타났으며 각 모드 특성도 구하였다. 진동의 응답은 가진 신호의 크기와 주파수를 주어 정현파의 가진력으로 외부 가진력을 근사화 하였고 이런 가진력에 의하여 발생하는 모드를 구별할 수 있었다. 상당 질량, 감쇠 및 강성을 변화시켜 수치 분석 후 외부 가진력에 의한 강제 진동 응답 특성을 체계적으로 분석하였다.

푸리에 변환과 주파수 민감도를 이용한 시변자장 시스템에서의 과도상태 해석 (Transient Analysis of Magnetodynamic Systems Using Fourier Transform and Frequency Sensitivity)

  • 최명준;김창현;박일한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.64-66
    • /
    • 1998
  • This paper presents a new efficient method for transient analysis in magnetodynamic systems of linear eddy current problems. This mehtod employs the Fourier transform and the high-order frequency sensitivity of harmonic finite element method. By taking into account the time-constant of magnetodynamic system, the Fourier integral of continuous frequency is converted into the Fourier series of discrete frequency. And with the results of Fourier series expansion of converted input wave form, the responses of each sinusoids is superposed to give the total response of the magnetodynamic systems. But, if the frequency band of input wave form is broad, it takes long computational time since all responses for each sinusoids must be calculated. Therefore, the high-order frequency sensitivity method is employed to estimate the response variation to frequency. The proposed algorithm is applied to an induction heating system to validate its numerical efficiency.

  • PDF

A Study on the Frequency Response Characteristics of High Response Flow Control Servo Valve

  • Seo Jong Soo;Shin You Sik;Chun Young Heung;Jeong Hyo Min;Chung Han Shik
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권3호
    • /
    • pp.131-140
    • /
    • 2004
  • The purpose of this research is to derive the principal design parameters governing the dynamic characteristics of the high response flow control servo valve. For this purpose, a numerical modeling of the servo valve system and a parameter sensitivity analysis to a frequency response characteristics were performed. As a result of these analysis, a basis for improvement of a dynamic characteristics of servo valve was arranged.