• 제목/요약/키워드: a frequency response

검색결과 4,805건 처리시간 0.037초

한반도 대기정체의 특성 및 지역기후모델 HadGEM3-RA를 이용한 미래 전망 (Characteristics of Air Stagnation over the Korean Peninsula and Projection Using Regional Climate Model of HadGEM3-RA)

  • 김도현;김진욱;김태준;변재영;김진원;권상훈;김연희
    • 대기
    • /
    • 제30권4호
    • /
    • pp.377-390
    • /
    • 2020
  • Not only emissions, but also atmospheric circulation is a key factor that affects local particulate matters (PM) concentrations in Korea through ventilation effects and transboundary transports. As part of the atmospheric circulation, air stagnation especially adversely affects local air quality due to weak ventilation. This study investigates the large-scale circulation related to air stagnation over Korea during winter and projects the climate change impacts on atmospheric patterns, using observed PM data, reanalysis and regional climate projections from HadGEM3-RA with Modified Korea Particulate matter Index. Results show that the stagnation affects the PM concentration, accompanied by pressure ridge at upper troposphere and weaken zonal pressure gradient at lower troposphere. Downscaling using HadGEM3-RA is found to yield Added-Value in the simulated low tropospheric winds. For projection of future stagnation, SSP5-8.5 and SSP1-2.6 (high and low emission) scenarios are used here. It has been found that the stagnation condition occurs more frequently by 11% under SSP5-8.5 and by 5% under SSP1-2.6 than in present-day climate and is most affected by changes in surface wind speed. The increase in the stagnation conditions is related to anticyclonic circulation anomaly at upper troposphere and weaken meridional pressure gradient at lower troposphere. Considering that the present East Asian winter monsoon is mainly affected by change in zonal pressure gradient, it is worth paying attention to this change in the meridional gradient. Our results suggest that future warming condition increase the frequency of air stagnation over Korea during winter with response of atmospheric circulation and its nonlinearity.

고 감쇠 폴리머 콘크리트를 활용한 지반진동 저감기술에 대한 연구 (Ground Vibration Reduction Technology Using High Damping Polymer Concrete)

  • 김정진;석원균;위준우;안소희
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권6호
    • /
    • pp.154-160
    • /
    • 2021
  • 최근에는 도심속에서 공사가 진행되는 경우가 크게 늘고 있는데, 이로 인해 기존 구조물 인근에서 공사에 의한 인위적인 진동이 자주 발생하기도 하고, 산업단지의 경우는 주변 기계류 작동 등에 의해서도 진동이 야기되어 문제가 발생하기도 한다. 한편, 구조물을 구성하고 있는 일반 콘크리트의 경우, 진동에 대한 감쇠성능이 작아, 구조물에 발생하는 진동뿐만 아니라 지반진동과 같이 외부로부터 구조물로 전달되는 다양한 진동을 차단하는데 어려움이 따른다. 이러한 지반을 통해 구조물로 전달되는 진동을 차단하기 위해서, 최근 폴리머 콘크리트를 활용하여 댐핑 성능을 크게 증가시킨 고 감쇠 시스템에 대한 연구가 활발히 진행되고 있다. 또한, 폴리머 콘크리트는 압축, 휨, 인장강도 등의 물리적 특성과 동적 특성이 매우 우수한 것으로 알려져 있어, 지반과 접한 구조물과 같이 큰 압력에 저항하면서 진동저감이 요구되는 구조물에의 폭넓은 활용이 기대되는 구조재료라 할 수 있다. 따라서, 본 연구에서는 폴리머 콘크리트의 지반진동 저감성능을 검토하기 위하여, 일반 콘크리트, 폴리우레탄 패드, 발포고무 패드와의 성능을 비교하였으며, 동적 특성으로 주파수 응답함수와 진동가속도에 대한 검토를 진행하여, 폴리머 콘크리트와 각각의 재료가 지하구조물에 적용될 경우의 동적 특성을 비교 검증한 후, 실 구조물에의 적용 가능성에 대해 검토하고자 한다.

2층 철골 구조물에 설치된 무정전전원장치의 실규모 진동대 실험연구 (Full-scale Shaking Table Test of Uninterruptible Power Supply Installed in 2-stories Steel Structure)

  • 이지언;박원일;최경규;오상훈;박훈양
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권3호
    • /
    • pp.29-38
    • /
    • 2022
  • 본 연구에서는 실규모의 2층 철골 구조물에 7종의 건축 및 비건축 비구조요소를 설치하여 진동대 실험을 수행하였다. 진동대 실험은 현행 비내진상세와 면진장치를 적용한 실험으로 두 차례 수행되었으며 본 연구에서는 무정전전원장치(UPS)의 내진성능에 대하여 실험 및 분석하였다. 비내진정착상세로는 UPS 하단에 ㄷ형강 다리부가 설치되었고, 면진장치로는 고감쇠고무와 와이어로프로 구성된 개발 복합면진장치가 사용되었다. 지진하중모사를 위하여 ICC-ES AC156 (2010)에 따라 인공지진파를 생성 후, 동일 지진파의 크기를 점증하여 가진하였다. 진동대실험을 통해 복합면진장치의 적용여부에 따른 UPS의 거동 및 동적 특성(응답가속도, 응답변위, 동증폭계수, 고유진동수, 감쇠비)을 비교 및 분석하였다. 실험결과, 복합면진장치를 적용함에 따라 UPS의 고유진동수가 감소하여 응답가속도 및 증폭계수가 크게 감소하는 것으로 확인되었다.

통계분석 기법과 머신러닝 기법의 비교분석을 통한 건물의 지진취약도 공간분석 (A Spatial Analysis of Seismic Vulnerability of Buildings Using Statistical and Machine Learning Techniques Comparative Analysis)

  • 김성훈;김상빈;김대현
    • 산업융합연구
    • /
    • 제21권1호
    • /
    • pp.159-165
    • /
    • 2023
  • 최근 지진 발생 빈도가 증가하고 있는 반면 국내 지진 대응 체계는 취약한 현실에서, 본 연구의 목적은 통계분석 기법과 머신러닝 기법을 활용한 공간분석을 통해 건물의 지진취약도를 비교분석 하는 것이다. 통계분석 기법을 활용한 결과, 최적화척도법을 활용해 개발된 모델의 예측정확도는 약 87%로 도출되었다. 머신러닝 기법을 활용한 결과, 분석된 4가지 방법 중, Random Forest의 정확도가 Train Set의 경우 94%, Test Set의 경우 76.7%로 가장 높아, 최종적으로 Random Forest가 선정되었다. 따라서, 예측정확도는 통계분석 기법이 약 87%, 머신러닝 기법이 76.7%로, 통계분석 기법의 예측정확도가 더 높은 것으로 분석되었다. 최종 결과로, 건물의 지진취약도는 분석된 건물데이터 총 22,296개 중, 1,627(0.1%)개의 건물데이터는 통계분석 기법 사용 시 더 위험하다고 도출되었고, 10,146(49%)개의 건물데이터는 동일하게 도출되었으며, 나머지 10,523(50%)개의 건물데이터는 머신러닝 기법 사용 시 더 위험하게 도출되었다. 기존 통계분석 기법에 첨단 머신러닝 기법활용결과가 추가로 비교검토 됨으로써 공간분석 의사결정에 있어서, 좀더 신뢰도가 높은 지진대응책 마련에 도움이 되길 기대한다.

장애인 복지시설 유형에 따른 급식관리 실태 조사 (Survey of Foodservice Management Status according to Welfare Facility Type for Disabled Persons)

  • 오다영;나우리;황서현;이정주;양유진;이혜옥;방지현;이해영;손정민
    • 대한영양사협회학술지
    • /
    • 제29권3호
    • /
    • pp.173-189
    • /
    • 2023
  • This study aimed to determine foodservice and hygiene management statuses at welfare facilities catering to disabled persons by facility type to provide basic data for foodservice management guidelines. An online survey was distributed to workers at 1,984 welfare facilities for disabled persons in Korea, and 531 facilities responded, which represented a response rate of 26.8%. The survey requested general information about the facilities, facility users, meals, hygiene, and management. Statistical analyses were performed, and frequency analysis and the chi-square test were used to investigate responses by facility type. The survey results revealed that daycare centers were most common and accounted for 27.4% of responses. Residential facilities for the severely disabled and sheltered workshops accounted for 16.9% and 16.4%, respectively, and residential facilities by disability type accounted for 13.0%. The presence of dietitians at welfare facilities varied by facility type. Welfare centers for the disabled (94.7%) had the highest percentage of dietitians, followed by residential facilities for the severely disabled (87.8%). On the other hand, sheltered workshops and daycare centers for disabled persons had the lowest percentages of dietitians (10.3% and 4.1%, respectively). This study highlights the variations that exist in foodservice management across different welfare facilities for disabled persons and emphasizes the challenges faced by those responsible for managing foodservices and maintaining hygiene, particularly in large facilities with no dietitians. Therefore, we recommend tailored meal management guidelines be developed for each type of welfare facility for disabled persons.

대학생이 인식하는 학생성공 개념에 관한 탐색적 연구: CQR-M 분석을 중심으로 (An Exploratory Study on the Concept of Student Success Recognized by College Students)

  • 류소형;탁진국
    • 한국심리학회지 : 코칭
    • /
    • 제5권1호
    • /
    • pp.33-65
    • /
    • 2021
  • 본 연구는 대학생이 인식하는 학생성공의 개념을 조사하기 위한 탐색적 연구이다. 학생들의 자유로운 생각을 듣기위해 온라인 설문지를 활용해 개방형 설문을 진행하고 99명의 응답을 분석하였다. 응답결과는 CQR-M(Consensual Qualitative Research-Modified)을 사용하여 분석하였다. 분석결과 '학생성공의 의미', '학생성공을 위한 대학 환경 요인', '학생성공에 필요한 심리적 요인' 등 3개의 영역에서 25개 범주가 도출되었다. 첫 번째 영역인 대학생이 인식하는 '학생성공의 의미'에서는 '학업성취·취업 역량 증진·다양한 경험 쌓기·만족스러운 취업·원하는 진로 설정·관계형성 능력 증진·나만의 목표 설정과 달성·자기 개발·만족스러운 대학생활'의 9개의 범주가 도출되었다. 두 번째 영역인 '학생성공을 위한 대학 환경 요인'에서는 '진로개발 지원·직무역량 향상 시스템·대학생활 참여지원·인적 네트워크 형성 기회·학습역량 증진 시스템·경제적 지원 확대·학생 편의를 위한 환경'으로 7개 범주가 도출되었다. 세 번째 영역인 '학생성공에 필요한 심리적 요인'에서는 '학습능력·자기효능감·대인관계 유능성·자기인식 및 개선·직무역량·자기조절 능력·풍부한 경험·진로인식·자존감'의 9개의 범주가 도출되었다. 각 영역별 빈도와 결과를 분석하여 제시하고, 연구의 의의와 제한점을 논의하였으며, 후속연구에 대한 제언을 하였다.

  • PDF

농작물 조직배양의 육종학적 이용에 관한 연구 제1보 벼 약배양효율에 대한 유전자형과 다른 요인간의 복합효과 (Studies on the Application of Tissue Culture for Plant Breeding I. Effect of genotype and other combined factors on the callus induction and plant regeneration in anther culture of rice)

  • 김광호
    • 한국작물학회지
    • /
    • 제28권4호
    • /
    • pp.425-430
    • /
    • 1983
  • 벼의 약배양효율을 증진시키는데 관여하는 요인들의 중요성을 검토하기 위하여 13개의 품종, 4개조합의 F$_1$, 7개조합의 F$_2$를 공시하여 이들의 약을 R$_2$배지에서 배양하였다. 유전자형간 약배양능력의 차이와 함께 약에 대한 저온처리, 배지의 당함량, 배지에 대한 생장조절제 첨가 등의 단독효과 및 유전자형과의 복합효과가 검토될 수 있도록 실험이 수행되었다. 1. 동일한 환경에서 재배된 벼품종 및 교배조합별 F$_1$들의 약배양능력간에는 큰 차이가 인정되었으며 포장에서 재배된 F$_2$들도 교배조합간에 평균 약배양능력이 크게 달랐다. 2. 동일한 교배조합의 F$_2$개체들 간에도 Callus분화율이 큰 변이를 보이고 있어 약배양능력이 유전변이를 보이는 형질임이 확인되었다. 3. 약을 배지에 치상하기 전 8$^{\circ}C$에 5-10일간 온도처리하는 것은 Callus 분화율을 향상시키는데 효과적이었는데 그 효과는 약배양능력이 높은 품종에서 더 컸다. 4. R$_2$배지의 당함량은 3-4%인 것이 Callus분화에 좋았으며 3-5%사이에서는 유전자형과의 복합효과가 인정되지 않았다. 5. R$_2$배지에서는 NAA만을 첨가하는 것이 Callus 분화율을 높이는데 효과적이었으며 약배양능력이 높은 유전자형을 이용했을 때 그 효과가 훨씬 더 컸다. 6. 약배양능력이 높은 유전자형을 선발, 이용하는 것이 약배양에 관여하는 요인들의 효율도 높일 수 있어 그 중요성이 가장 크다고 할 수 있다.

  • PDF

시나리오 플래닝을 적용한 한국의 가뭄 위험도 전망 및 가뭄 위험 단계에 따른 가뭄관리 방안 (Drought risk outlook using scenario planning and drought management according to drought risk levels in Korea)

  • 김지은;김민지;김석우;김태웅
    • 한국수자원학회논문집
    • /
    • 제57권1호
    • /
    • pp.45-58
    • /
    • 2024
  • 기후변화로 인해 가뭄의 빈도, 심도 및 지속기간 등이 증가함에 따라 가뭄 위험도가 높아질 것으로 전망되고 있다. 가뭄 위험도는 수문기상학적 요인뿐만 아니라 용수의 공급 및 수요와 관련 있다. 최근에는 기후변화와 함께 사회경제적인 요인도 가뭄 위험도를 높이는 것으로 나타나고 있다. 따라서 미래에 발생가능한 심각한 가뭄에 적절히 대응하기 위하여 다양한 조건에서의 가뭄 위험도를 전망할 필요가 있다. 또한, 다양한 시나리오를 고려하는 것은 미래의 가뭄 위험도 전망이 가지는 불확실성을 줄이는데 도움이 될 것이다. 본 연구에서는 한국의 160개 시군구에 대한 기후변화 시나리오와 인구 및 용수 수요량 등을 고려하여 가뭄 시나리오를 작성하고 이에 따른 가뭄 위험도를 전망하였으며, 가뭄 위험도 전망 결과를 토대로 가뭄 위험 단계를 재설정하였다. 그 결과 한국의 가뭄 위험도는 과거에 비해 2020, 2025 및 2030년에서 모두 높아지는 것으로 나타났다. 특히, 기준 및 고위 시나리오에 따르면 2030년에는 가뭄 위험도가 과거보다 약 2배 정도 증가하는 것으로 나타났다. 본 연구에서 산정된 가뭄 전망 결과를 새로운 가뭄 위험 단계에 적용한 결과, 기준 및 고위 시나리오에서는 2020년 및 2030년에 한국 대부분의 지역에서 대응(V) 단계로 나타났다.

9시 등교정책이 중학생의 아침식사, 수면 및 신체활동에 미치는 영향 (Effects of School Attendance Policy on Breakfast Eating, Sleep, and Physical Activity in Middle School Students)

  • 김하나;김성영
    • 한국식품영양과학회지
    • /
    • 제46권11호
    • /
    • pp.1397-1407
    • /
    • 2017
  • 경기도 안산지역에 위치한 중학교에 재학 중인 2학년과 3학년 426명을 대상으로 9시 등교정책 실시에 따른 아침식사 섭취 빈도의 증가와 더불어 아침식사 관련인자, 간식, 수면 및 신체활동에 미치는 영향 및 이들의 인식도에 대해 조사한 후 결과를 요약하면 다음과 같다. 연구 대상자의 성별은 남학생이 222명(52.1%), 여학생이 204명(47.9%)이었으며 학년은 2학년 228명(53.5%), 3학년 198명(46.5%)이었다. 9시 등교정책 전 남학생의 약 39%가 '매일 식사를 했다'고 응답한 반면, 9시 등교정책 후에는 44.6%가 매일 아침식사를 하는 것으로 나타났다(P>0.05). 여학생 또한 9시 등교정책 후 정책 전의 32.4%에서 35.8%로 약간 상승하는 것으로 나타났다(P<0.05). 아침결식의 주된 이유는 9시 등교정책의 실시와 성별에 관계없이 '아침식사 시간의 부족', '입맛이 없어서'와 '늦게 일어나서'라는 응답 비율이 높은 것으로 나타났다. 간식 섭취 빈도는 9시 등교정책과 성별에 관계없이 '1~2회'가 가장 많았으나 9시 등교정책 전(P<0.05)과 후(P<0.05) 모두 '3~4회'와 '5회 이상'은 남학생에 비해 여학생의 간식 섭취 빈도가 많은 것으로 나타났다. 간식 섭취의 주된 이유는 9시 등교정책과 성별에 관계없이 '배가 고파서'라는 이유가 가장 많은 것으로 나타났다. 수면시간은 9시 등교정책 전과 후 모두 성별에 관계없이 '7~8시간'이라는 응답이 가장 많은 것으로 나타났으나 9시 등교정책 후 남학생과 여학생 모두 '8~9시간'의 응답 비율은 증가한 반면에 '7시간 미만'이라는 응답 비율은 감소하는 것으로 나타나 남학생(P<0.05)과 여학생(P<0.01) 모두 9시 등교정책의 실시로 인해 수면시간이 증가한 것으로 보인다. 그러나 9시 등교정책 전(P<0.001)과 후(P<0.01) 모두 남학생에 비해 여학생의 수면시간은 상대적으로 적은 것으로 나타났다. 일주일에 30분 이상의 운동을 하는 빈도를 조사한 결과 9시 등교정책 전 남학생은 '3~4회'가 27.5%로 가장 많은 반면, 여학생은 '0회'가 44.1%로 가장 많은 것으로 나타났다(P<0.001). 9시 등교정책 이후에도 남학생의 주당 운동 빈도는 여전히 '3~4회'가 28.4%로 가장 많은 반면, 여학생은 '1~2회'가 36.3%로 가장 많은 것으로 나타나 9시 등교정책 후에도 여전히 여학생에 비해 남학생의 운동 빈도가 상대적으로 많은 것으로 나타났다(P<0.001). 9시 등교정책에 대한 인식도를 조사한 결과 9시 등교정책이 아침식사 섭취 빈도를 증가시킨 것으로 인식한 남학생은 56.8%, 여학생은 53.9%였다. 숙면을 취하는 데 영향을 주었다고 인식한 남학생은 39.2%, 여학생은 47.1%였으며 신체적인 피로도의 감소(남학생 40.1%, 여학생 38.2%) 및 신체적인 건강의 향상(남학생 36.5%, 여학생 32.8%)에도 기여한 것으로 인식하고 있었다. 본 연구 결과 안산지역 중학생들은 9시 등교정책이 아침식사 섭취 빈도의 증가, 숙면 및 신체적인 기능을 향상시키는 데 긍정적인 영향을 준 것으로 인식하는 것으로 나타났다. 따라서 9시 등교정책이 중학생들의 규칙적인 아침식사를 통한 깊은 수면의 유도 및 바람직한 신체활동을 통한 건강한 학교생활이 지속될 수 있도록 학교와의 지속적인 협력 및 연계를 통한 국가차원의 정책적인 지원이 요구된다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF