• Title/Summary/Keyword: a data acquisition

Search Result 3,042, Processing Time 0.041 seconds

The Comparison of the Solar Radiation and the Mean Radiant Temperature (MRT) under the Shade of Landscaping Trees in Summertime (하절기 조경용 녹음수 수관 하부의 일사와 평균복사온도 비교)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.5
    • /
    • pp.22-30
    • /
    • 2014
  • The purpose of this study was to compare the Solar Radiation(SR) and the Mean Radiant Temperature(MRT) under the shades of the three landscaping trees in clear summer daytimes. The trees were Lagerstroemia indica, Quercus palustris and Ulmus parvifolia. The solar radiation, the globe temperature and the air temperature were recorded every minute from the $1^{st}$ of April to the $30^{th}$ of September 2013 at a height of 1.1m above on the four monitoring stations, with four same measuring system consisting of a solar radiation sensor, two resistance temperature detectors(Pt-100), a black brass globe (${\phi}50mm$) and data acquisition systems. At the same time, the sky view photos were taken automatically hourly by three scouting cameras(lens angle: $60^{\circ}$) fixed at each monitoring station. Based on the 258 daily sky view photos and 6,640 records of middays(10 A.M.~2 P.M.) from the $1^{st}$ of June to the $30^{th}$ of August, the time serial differences of SR and MRT under the trees were analysed and compared with those of open sky, The major findings were as follows; 1. The average ratio of sky views screened by the canopies of Quercus palustris, Lagerstroemia indica and Ulmus parvifolia were 99%, 98% and 97%, and the SR were $106W/m^2$, $163W/m^2$ and $202W/m^2$ respectively, while the SR of open sky was $823W/m^2$. Which shows the canopies blocked at least 70% of natural SR. 2. The average MRT under the canopies of Quercus palustris, Lagerstroemia indica and Ulmus parvifolia were $30.34^{\circ}C$, $33.34^{\circ}C$ and $34.77^{\circ}C$ respectively, while that of open sky was $46.0^{\circ}C$. Therefore, it can be said that the tree canopies can reduce the MRT around $10{\sim}16^{\circ}C$. 3. The regression test showed significant linear relationship between the SR and MRT. In summary, the performances of the landscaping shade trees were very good at screening the SR and reducing the MRT at the outdoor of summer middays. Therefore, it can be apparently said that the more shade trees or forest at the outdoor, the more effective in conditioning the outdoor space reducing the MRT and the useless SR for human activities in summertime.

A quantitative study on the minimal pair of Korean phonemes: Focused on syllable-initial consonants (한국어 음소 최소대립쌍의 계량언어학적 연구: 초성 자음을 중심으로)

  • Jung, Jieun
    • Phonetics and Speech Sciences
    • /
    • v.11 no.1
    • /
    • pp.29-40
    • /
    • 2019
  • The paper investigates the minimal pair of Korean phonemes quantitatively. To achieve this goal, I calculated the number of consonant minimal pairs in the syllable-initial position as both raw counts and relative counts, and analyzed the part of speech relations of the two words in the minimal pair. "Urimalsaem" was chosen as the object of this study because it was judged that the minimal pair analysis should be done through a dictionary and it is the largest among Korean dictionaries. The results of the study are summarized as follows. First, there were 153 types of minimal pairs out of 337,135 examples. The ranking of phoneme pairs from highest to lowest was 'ㅅ-ㅈ, ㄱ-ㅅ, ㄱ-ㅈ, ㄱ-ㅂ, ㄱ-ㅎ, ${\ldots}$, ㅆ-ㅋ, ㄸ-ㅋ, ㅉ-ㅋ, ㄹ-ㅃ, ㅃ-ㅋ'. The phonemes that played a major role in the formation of the minimal pair were /ㄱ, ㅅ, ㅈ, ㅂ, ㅊ/, in that order, which showed a high proportion of palatals. The correlation between the raw count of minimal pairs and the relative count of minimal pairs was found to be quite high r=0.937. Second, 87.91% of the minimal pairs shared the part of speech (same syntactic category). The most frequently observed type has been 'noun-noun' pair (70.25%), and 'vowel-vowel' pair (14.77%) was the next ranking. It can be indicated that the minimal pair could be grouped into similar categories in terms of semantics. The results of this study can be useful for various research in Korean linguistics, speech-language pathology, language education, language acquisition, speech synthesis, and artificial intelligence-machine learning as basic data related to Korean phonemes.

Smoking Adolescents' Acquisition of Cigarettes and Status of Proof of Age (흡연을 하는 청소년의 담배 구입 경로 및 신분 확인의 유무)

  • Kim, Hee Ra;Kim, Ji Young;Lee, Gee Hyung;Choung, Ji Tae;Park, Sang Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.4
    • /
    • pp.363-368
    • /
    • 2005
  • Purpose : The aim of this study is to identify where and how adolescents acquire cigarettes and how many were asked for identification while purchasing cigarettes. Methods : This study was conducted in 2003; participants were 2,200 students in middle and high schools, aged from 13 to 18 years old(males 1,098; females 1,102) in Ansan, Korea. The questionnaire assured them of anonymity, and self-administered in school. The data was analyzed with chisquare test for trends. Results : The prevalence of smoking was about 20 percent among respondents, was higher in males than in females, and in older students than in younger students(P<0.001). The most frequent source of cigarettes was purchased from a store(36.3 percent). About 29.2 percent of the students borrowed from friends or family members. By sex, the main sources of cigarettes were purchase from a store and borrowing. Younger students were borrowed more cigarettes; older students purchased more cigarettes from stores. Only 48.8 percent were asked for proof of age during their purchase. Of those asked for proof of age, about 73.3 percent answered that this made it difficult to buy cigarettes(P<0.001), and they thought that it was more difficult when asked for a photo ID than simply being asked their age(P=0.019). Conclusion : So far, there has been no systemic prevention of adolescents' smoking. It is difficult for minors to purchase cigarettes if asked for proof of age, but most minors go to stores to purchase cigarettes. Therefore, prevention efforts should include educating retailers not to sell cigarettes to minors and enforcing existing laws requiring youth to provide proof of age when attempting to buy cigarettes.

On-line Quality Assurance of Linear Accelerator with Electronic Portal Imaging System (전자포탈영상장치(EPID)를 이용한 선형가속기의 기하학적 QC/QA System)

  • Lee, Seok;Jang, Hye-Sook;Choi, Eun-Kyung;Kwon, Soo-Il;Lee, Byung-Yong
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.127-136
    • /
    • 1998
  • On-line geometrical quality assurance system has been developed using electronic portal imaging system(OQuE). EPID system is networked into Pentium PC in order to transmit the acquisited images to analysis PC. Geometrical QA parameters, including light-radiation field congruence, collimator rotation axis, and gantry rotation axis can be easily analyzed with the help of graphic user interface(GUI) software. Equipped with the EPID (Portal Vision, Varian, USA), geometrical quality assurance of a linear accelerator (CL/2100/CD, Varian, USA), which is networked into OQuE, was performed to evaluate this system. Light-radiation field congruence tests by center of gravity analysis shows 0.2~0.3mm differences for various field sizes. Collimator (or Gantry) rotation axis for various angles could be obtained by superposing 4 shots of angles. The radius of collimator rotation axis is measured to 0.2mm for upper jaw collimator, and 0.1mm for lower jaw. Acquisited images for various gantry angles were rotated according to the gantry angle and actual center of image point obtained from collimator axis test. The rotated images are superpositioned and analyzed as the same method as collimator rotation axis. The radius of gantry rotation axis is calculated 0.3mm for anterior/posterior direction (gantry 0$^{\circ}$ and 170$^{\circ}$) and 0.7mm for right/left direction(gantry 90$^{\circ}$ and 260$^{\circ}$). Image acquisition for data analysis is faster than conventional method and the results turn out to be excellent for the development goal and accurate within a milimeter range. The OQuE system is proven to be a good tool for the geometrical quality assurance of linear accelerator using EPID.

  • PDF

BIOMECHANICS OF ABUTMENTS SUPPORTING REMOVABLE PARTIAL DENTURES UNDER UNILATERAL LOADING

  • Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Jeong-Taek;Roh, Hyun-Ki;Kim, Hyo-Jin;Lee, Seok-Hyung;Lee, Joo-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.753-759
    • /
    • 2007
  • Statement of problem. In distal extension removable partial denture, the preservation of health of abutment teeth is very important, but abutment teeth are subjected to unfavorable stress under unilateral loading specially. Purpose. The purpose of this study was to investigate the biomechanical effects of mandibular removable partial dentures with various prosthetic designs under unilateral loading, using strain gauge analysis. Material and methods. Artificial teeth of both canines were anchored bilaterally in a mandibular edentulous model made of resin. Bilateral distal extension removable partial dentures with splinted and unsplinted abutments were fabricated. Group 1: Clasp-retained mandibular removable partial denture with unsplinted abutments Group 2: Clasp-retained mandibular removable partial denture with splinted abutments by 6-unit bridge. Group 3: Bar-retained mandibular removable partial denture Strain gauges were bonded on the labial plate of the mandibular resin model, approximately 2 mm dose to the abutments. Two unilateral vertical experimental loadings (30N and 100N) were applied subsequently via miniature load cell that were placed at mandibular left first molar region. Strain measurements were performed and simultaneously monitored from a computer connected to data acquisition system. For within-group evaluations, t-test was used to compare the strain values and for between-group comparisons, a one-way analysis of variance (ANOVA) was used and Tukey test was used as post hoc comparisons. Results. The strain values of group 1 and 2 were tensile under loadings. In contrast, strain values of group 3 were compressive in nature. Strain values increased as the applied load in increased from 30N to 100N (p<.05) except for right side in group 1. Under 30N loading, in left side, group 1 showed higher strain values than groups 2 and 3 in absolute quantity (p<.05). And group 2 showed higher strain values than group 1 (p<.05). In right side, group 1 and 2 showed higher strain values than group 3 in absolute quantity (p<.05). Under 100N loading in left side, group 1 showed higher strain values than groups 2 and 3 in absolute quantity (p<.05). And group 2 showed higher strain values than group 1 (p<.05). In right side, group 1 and 2 showed higher strain values than group 3 in absolute quantity (p<.05). Under 30N loading, group 2 and 3 showed higher strain values in right side than in left side. Under 100N loading, right side strain values were higher than left side ones for all groups. Conclusion. Splinting of two isolated abutments by bridge reduced the peri-abutment strain in comparison with unsplinted abutments under unilateral loading. Bar-retained removable partial denture showed the lowest strain of three groups, and compressive nature.

Evaluation of Image Quality using SE-EPI and SSH-TSE Techniques in MRDWI (자기공명확산강조영상에서 SE-EPI 와 SSH-TSE 기법을 이용한 영상의 질 평가)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.991-998
    • /
    • 2021
  • The purpose of this study is to investigate the image quality of the SE-EPI and SSH-TSE technique for MR DWI. Datum were analyzed for 35 PACS transmission datum(Normal part: 12 males, 13 females, Cerebral Infarction: 10(5males and 5females), and average age 68±7.32), randomly selected patients who underwent MRDWI tests. The equipment used was Ingenia CX 3.0T, SSH_TSE and SE-EPI pulse sequence and 32 Ch. head coil were used for data acquisition. Image evaluation was performed on the paired t-test and Wilcoxon tests, and was considered significant when the p value was 0.05 or less. As a result of quantitative analysis of SNR for DWI images, the mean and standard deviation values of 4 parts (WM, GM, BG, Cerebellum) in ADC (s/mm2), Diffusion b=0, 1000 images were higher in SE-EPI techniques(ADC: 120.50 ± 40, b=0: 54.50 ± 35.91, b=1000: 91.61 ± 36.63) than in SSH-TSE techniques(ADC: 99.69 ± 31.10, b=0: 43.52 ± 25.00 , b=1000: 60.74 ± 24.85)(p<0.05). The CNR values for GM-WM, BG-WM sites were also higher in SE-EPI technique (ADC: 116.08 ± 43.30, b=0:27.23 ± 09.10, b=1000: 78.50 ± 16.56) than in SSH-TSE(ADC: 101.08 ± 36.81, b=0: 23.96 ± 07.79 , b=1000: 74.30 ± 14.22). As a visual evaluation of observers, ghost artifact, magnetic susceptibility artifacts and overall image quality for SE-TSE and SSH-TSE all yielded high results from SSH-TSE techniques(ADC:3.6 ± 0.1, 2.8 ± 0.2, b=0: 4.3 ± 0.3, 3.4 ± 0.1 b=1000: 4.3 ± 0.2, 3.5 ± 0.2, p=0.000). In conclusion, the SE-EPI technique obtained an superiority in SNR and CNR measurements using SSH-TSE, SE-EPI. In the qualitative analysis, the SSH-TSE pulse sequence was obtained a high result according to the pulse sequence characteristics.

Analysis of Soil Changes in Vegetable LID Facilities (식생형 LID 시설의 내부 토양 변화 분석)

  • Lee, Seungjae;Yoon, Yeo-jin
    • Journal of Wetlands Research
    • /
    • v.24 no.3
    • /
    • pp.204-212
    • /
    • 2022
  • The LID technique began to be applied in Korea after 2009, and LID facilities are installed and operated for rainwater management in business districts such as the Ministry of Environment, the Ministry of Land, Infrastructure and Transport, and LH Corporation, public institutions, commercial land, housing, parks, and schools. However, looking at domestic cases, the application cases and operation periods are insufficient compared to those outside the country, so appropriate design standards and measures for operation and maintenance are insufficient. In particular, LID facilities constructed using LID techniques need to maintain the environment inside LID facilities because hydrological and environmental effects are expressed by material circulation and energy flow. The LID facility is designed with the treatment capacity planned for the water circulation target, and the proper maintenance, vegetation, and soil conditions are periodically identified, and the efficiency is maintained as much as possible. In other words, the soil created in LID is a very important design element because LID facilities are expected to have effects such as water pollution reduction, flood reduction, water resource acquisition, and temperature reduction while increasing water storage and penetration capacity through water circulation construction. In order to maintain and manage the functions of LID facilities accurately, the current state of the facilities and the cycle of replacement and maintenance should be accurately known through various quantitative data such as soil contamination, snow removal effects, and vegetation criteria. This study was conducted to investigate the current status of LID facilities installed in Korea from 2009 to 2020, and analyze soil changes through the continuity and current status of LID facilities applied over the past 10 years after collecting soil samples from the soil layer. Through analysis of Saturn, organic matter, hardness, water contents, pH, electrical conductivity, and salt, some vegetation-type LID facilities more than 5 to 7 years after construction showed results corresponding to the lower grade of landscape design. Facilities below the lower level can be recognized as a point of time when maintenance is necessary in a state that may cause problems in soil permeability and vegetation growth. Accordingly, it was found that LID facilities should be managed through soil replacement and replacement.

Optimization of Conditions for Conidial Production in Bipolaris oryzae Isolated from Rice (벼 깨씨무늬병 Bipolaris oryzae의 포자 형성 방법 개선)

  • Seol-Hwa Jang;Seyeon Kim;Shinhwa Kim;Hyunjung Chung;Sook-Young Park
    • Research in Plant Disease
    • /
    • v.30 no.3
    • /
    • pp.229-235
    • /
    • 2024
  • Conidial production is a critical factor in testing pathogenicity and studying the physiology and ecology of fungal pathogens. Therefore, selecting an appropriate condition and medium for consistent conidia production is essential. In this study, we investigated light conditions and suitable medium conditions using the slide culture method to establish optimal conditions for continuous spore acquisition of Bipolaris oryzae. Primarily, we observed conidial production using two B. oryzae isolates, CM23-042 and 23CM10, under two different light conditions: (1) consistent near-ultraviolet (NUV) with fluorescent light, and (2) a 12-hr shift of the NUV-dark cycle. Secondly, we examined conidial formation under seven different media on potato dextrose agar (PDA), V8-Juice agar, minimal medium (MM), sucrose-proline agar (SPA), rabbit food agar (RFA), rice bran agar (RBA), and rice leaf agar (RLA). Under consistent NUV light with fluorescent conditions, conidia were induced in both isolates, whereas conidia were not produced under other conditions after 7 days post-inoculation (dpi). Moreover, B. oryzae isolate CM23-042 produced the highest number of conidia in MM, while isolate 23CM10 yielded the highest number of conidia in PDA after 7 dpi. In summary, our data demonstrated that the consistent NUV light with fluorescent conditions were most conducive for conidia induction in B. oryzae. The selection of a medium for conidiation may vary depending on the B. oryzae isolates, but using MM and PDA or SPA and RFA medium could be effective for spore induction. These findings will contribute to improving conidiation according to the characteristics of collected isolates of B. oryzae.

Comparison of Radiation Dose in the Measurement of MDCT Radiation Dose according to Correction of Temperatures and Pressure, and Calibration of Ionization Chamber (MDCT 선량측정에서 온도와 압력에 따른 보정과 Ionization Chamber의 Calibration 전후 선량의 비교평가)

  • Lee, Chang-Lae;Kim, Hee-Joung;Jeon, Seong-Su;Cho, Hyo-Min;Nam, So-Ra;Jung, Ji-Young;Lee, Young-Jin;Lee, Seung-Jae;Dong, Kyung-Rae
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.49-55
    • /
    • 2008
  • This study aims to conduct the comparative analysis of the radiation dose according to before and after the calibration of the ionization chamber used for measuring radiation dose in the MDCT, as well as of $CTDI_w$ according to temperature and pressure correction factors in the CT room. A comparative analysis was conducted based on the measured MDCT (GE light speed plus 4 slice, USA) data using head and body CT dosimetric phantom, and Model 2026C electrometer (RADICAL 2026C, USA) calibrated on March 21, 2007. As a result, the $CTDI_w$ value which reflected calibration factors, as well as correction factors of temperature and pressure, was found to be the range of $0.479{\sim}3.162mGy$ in effective radiation dose than the uncorrected values. Also, under the routine abdomen routine CT image acquisition conditions used in reference hospitals, patient effective dose was measured to indicate the difference of the maximum of 0.7 mSv between before and after the application of such factors. These results imply that the calibration of the ion chamber, and the correction of temperature and pressure of the CT room are crucial in measuring and calculating patient effective dose. Thus, to measure patient radiation dose accurately, the detailed information should be made available regarding not only the temperature and pressure of the CT room, but also the humidity and recombination factor, characteristics of X-ray beam quality, exposure conditions, scan region, and so forth.

  • PDF

Expression of CD40, CD86, and HLA-DR in CD1c+ Myeloid Dendritic Cells Isolated from Peripheral Blood in Primary Adenocarcinoma of Lung (원발성 폐선암환자의 말초혈액에서 분리한 CD1c+ 골수성 수지상 세포에서의 CD40, CD86 및 HLA-DR의 발현)

  • Kang, Moon-Chul;Kang, Chang-Hyun;Kim, Young-Tae;Kim, Joo-Hyun
    • Journal of Chest Surgery
    • /
    • v.43 no.5
    • /
    • pp.499-505
    • /
    • 2010
  • Background: There have been several reports using animal experiments that CD1-restricted T-cells have a key role in tumor immunity. To address this issue, we studied the expression of markers for CD1c+ myeloid dendritic cells (DCs) isolated from peripheral blood in the clinical setting. Material and Method: A total of 24 patients with radiologically suspected or histologically confirmed lung cancer who underwent pulmonary resection were enrolled in this study. The patients were divided according to histology findings into three groups: primary adenocarcinoma of lung (PACL), primary squamous cell carcinoma of lung (PSqCL) and benign lung disease (BLD). We obtained 20 mL of peripheral venous blood from patients using heparin-coated syringes. Using flow-cytometry after labeling with monoclonal antibodies, data acquisition and analysis were done. Result: The ratio of CD1c+CD19- dendritic cells to CD1c+ dendritic cells were not significantly different between the three groups. CD40 (p=0.171), CD86 (p=0.037) and HLA-DR (p=0.036) were less expressed in the PACL than the BLD group. Expression of CD40 (p=0.319), CD86 (p=0.036) and HLA-DR (p=0.085) were less expressed in the PACL than the PSqCL group, but the differences were only significant for CD86. Expression of co-stimulatory markers was not different between the PSqCL and BLD groups. Expression of markers for activated DCs were dramatically lower in the PACL group than in groups with other histology (CD40 (p=0.005), CD86 (p=0.013) HLA-DR (p=0.004). Conclusion: These results suggest the possibility that CD1c+ myeloid DCs participate in control of the tumor immunity system and that low expression of markers results in lack of an immune response triggered by dendritic cells in adenocarcinoma of the lung.