• 제목/요약/키워드: a chamber

검색결과 6,497건 처리시간 0.033초

공압용 더블챔버 로터에서 베인개수에 따른 성능특성에 관한 실험적연구 (An Experimental Study of Performance Characteristics on a Double Chamber Rotor Operated by High Pressure Air with Various Vanes)

  • 조종현;최상규;조수용
    • 한국유체기계학회 논문집
    • /
    • 제9권6호
    • /
    • pp.54-62
    • /
    • 2006
  • An experiment about performance characteristics is conducted on a double chamber vane-type rotor. Three different rotors, which have 6, 8 and 9 vanes, are applied to the driver and various lift holes at the rear plate are used to increase the effective vane height. The inner diameter of a double chamber cylinder is ${\phi}27mm$, and the length of the cylinder is 65 mm. The maximum offset length between the rotor outer surface and the cylinder inner surface is 4.5 mm. In this study, specific output torques and powers are measured, and also noise and vibration are measured at the real operating situation. The operating torque on the double chamber is increased to 17% compared to the operating torque obtained at the single chamber which has the same size. The experimental results of noise and vibration show that the operating sound and vibration are directly related to the operating power generated by the double chamber rotor.

소형 연소기 냉각 유로 개념 설계 (Conceptual Design of Coolant Channel for Sub-scale Combustion Chamber)

  • 정용현;조원국;한상엽;류철성
    • 한국추진공학회지
    • /
    • 제6권4호
    • /
    • pp.1-6
    • /
    • 2002
  • 소형 연소기의 냉각 유로 설계를 위하여 열전달 및 냉각 유로의 구조해석을 수행하였다. 연소기의 고온가스에서의 열전달에 관한 2차원 해석을 수행하여 연소실 벽으로의 열유속을 예측한 다음 이를 3차원 해석을 위한 열경계 조건으로 적용하였다. 위 방법으로 예측한 열 유속은 기존의 경험식과 비교하여 검증하였으며 냉각수의 유량에 둔감한 것으로 판명되어 냉각 조건이 변화하더라도 동일한 열경계 조건을 사용할 수 있었다. 단일 냉각 유로에 대한 3차원 해석을 수행하여 연소실 벽의 최대온도 변화를 예측하였으며 이는 재사용 연소기 개발에 적용될 것이다. 냉각 유로의 정적 구조 해석을 통해 응력 분포와 구조 안전성을 예측하였다.

실물형 액체로켓 연소기 지상 연소 성능 결과 (Combustion Performance of a Fullscale Liquid Rocket Thrust Chamber)

  • 서성현;김종규;문일윤;한영민;최환석;이수용;조광래
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제25회 추계학술대회논문집
    • /
    • pp.235-239
    • /
    • 2005
  • 저궤도 위성 발사체에 적용 가능한 추력 30 tonf급의 연소기가 설계/제작되어 전반적인 연소 시험을 마쳤다. 터보 펌프식 개방형 사이클에 적용 가능한 재생냉각형으로 제작된 본 연소기는 초기 연소 성능 및 기능 검증을 위해 내열재 방식의 연소실을 이용하여 연소 시험을 수행하였다. 설계 조건을 중심으로 넓은 작동 구간에서 본 연소기는 안정된 연소 성능을 보였다. 연소기의 물리적 손상 또한 발생하지 않았으며, 만족할 만한 기능적 특성을 나타내었다. 연소기의 성능은 연소 효율이 95%, 그리고 지상 비추력이 254초로 초기 설계 대비 초과 내지는 동등 수준의 결과를 보였다.

  • PDF

디지털 흉부 측와위 후전방향 검사 시 Ion chamber조합 설정과 관전압 변화에 따른 장기선량 및 화질 평가 (Evaluation on Organ Dose and Image Quality by Changing kVp and Ion Chamber Combination while Taking Digital Chest Lateral Decubitus PA Projection)

  • 이진수;박형후
    • 한국콘텐츠학회논문지
    • /
    • 제15권1호
    • /
    • pp.316-323
    • /
    • 2015
  • 본 연구는 디지털 흉부 측와위 후전방향 검사 시 Ion chamber 설정과 관전압 변화에 따른 피폭선량과 변조전달함수를 측정하여 최적의 진단 영상을 획득하고 환자의 피폭선량을 최소화하는 방안에 대하여 제안하고자 하였다. 실험은 디지털 검출기를 이용하여 흉부 측와위 검사법 중 우측 측와위 상태를 가정하여 Ion chamber를 7가지 조합으로 설정하고, 관전압 변화(100, 110, 120, 130 kVp)에 따라 각 5회씩 촬영하여 표면선량을 측정한 후 평균값을 산출하였다. 실험에서 얻어진 표면선량 값을 몬테카를로 시뮬레이션 프로그램 인 PCXMC에 입력하여 장기선량 및 유효선량을 각각 산출하였고, 영상의 화질을 비교하기 위하여 MTF로 물리적 화질 평가를 하였다. 그 결과 관전압이 높을수록 표면선량이 감소하였으며, Ion chamber 변화에 따른 장기선량과 유효선량은 2번 Ion chamber 설정 시 가장 낮게 나타났으며, 1번 Ion chamber 설정 시 가장 높게 나타났다. MTF 결과는 관전압 120 kVp, 2번 Ion chamber를 설정 시 가장 우수하게 나타났다. 따라서 DR을 이용한 흉부 우측 측와위 촬영 시 화질의 저하 없이 피폭선량을 효과적으로 감소시키며 우수한 영상을 획득할 수 있는 최적의 조합은 관전압 120 kVp와 2번 Ion chamber를 설정하는 것이다.

삼심방증 치험 2례 (Cor Triatrium; A Classic Type and a Type Combibed with Atrial Septal Defect; Report of Two Cases)

  • 손제문
    • Journal of Chest Surgery
    • /
    • 제26권7호
    • /
    • pp.543-547
    • /
    • 1993
  • Cor triatriatum is a rare entity of congenital heart disease characterized by the presence of a fibrousmuscular diaphragm that subdivides the left atrium into a proximal or "accessory" chamber and a distal or "true" left atrial chamber. In the other hand, cor triatriatum is a variant of abnormal connection between the pulmonary vein and true left atrium which is separated from accessory left atrium receiving pulmonary venous blood flow by fibromuscular diaphragm. We experienced two cases of cor triatriatum. One of them was classical, and the other case was combined with atrial septal defect and all pulmonary veins were drained into the " common pulmonary venous chamber " which connected with right atrium and there was no direct communication between the accessory chamber and true left atrium. The abnormal diaphragms were excised and the atrial septal defect was repaired with pericardial patch in case II. The postoperative courses were not eventful and the patients were discharged with good result, and have been in good condition upto now.n good condition upto now.

  • PDF

STABILITY OF A ROTATING BALL

  • Bykov, V.;Dementiev, O.
    • Journal of applied mathematics & informatics
    • /
    • 제9권1호
    • /
    • pp.277-288
    • /
    • 2002
  • Influence of form errors of a chamber filled with a liquid on the movement and stability of a ball, rotating in the chamber, is studied. Two cases of the influence of the chamber form errors on the forces, acting on the ball, are defined. The first case describes the situation when limitations on the rotor shift are not imposed and disturbances of the chamber form are set by spherical harmonics not above the first order. In the second case disturbance of a chamber form is arbitrary and the rotor is supposed small. A rising here diflective moment tends to direct the angular speed vector along the small semiaxis of the ellipsoid, i.e., a stable position of the rotor appears.

고압산소챔버 중재가 알코올에 의한 산화적 스트레스 및 숙취 해소에 미치는 영향 (Effects of Hyperbaric Oxygen Intervention on Alcohol-Induced Oxidative Stress and Hangover in Hyperbaric Oxygen Chamber)

  • 권혁찬;박순원;조현정;강지현;이현주;태기식
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권5호
    • /
    • pp.175-182
    • /
    • 2018
  • The purpose of this study is to evaluate the reliability and effectiveness of hyperbaric oxygen chamber on alcohol-induced oxidative stress and hangover. In order to evaluate them, 20 healthy adults were tested for blood and hangover stress tests. When an exponential change was examined after 3 interventions (hangover drink, hyperbaric oxygen chamber, and normal chamber as placebo effect) of 1 hour, the heart rate of subjects experiencing a hyperbaric oxygen chamber showed a statistically significant decrease (p < 0.001). The tests of blood alcohol concentration (BAC) as for exquisite hematology analysis, glucose, creatinine, and AST (aspartate aminotransferase) as well as ALT (alanine aminotransferase) used as liver-damage indicator show that the hyperbaric chamber has the effective effect. In the test of lactic acid, CRP (c-reactive protein), cortisol, and creatinine, the hyperbaric chamber shows much more excellent effect than the hangover drink and normal chamber as control groups. Further studies on hyperbaric oxygen chamber intervention including this study could be very helpful for improving lives of both the patients and healthy people.

Age Estimation by Radiological Measuring Pulp Chamber of Mandibular First Molar in Korean Adults

  • Jeon, Hye-Mi;Kim, Jin-Hwa;Heo, Jun-Young;Ok, Soo-Min;Jeong, Sung-Hee;Ahn, Yong-Woo
    • Journal of Oral Medicine and Pain
    • /
    • 제40권4호
    • /
    • pp.146-154
    • /
    • 2015
  • Purpose: The purpose of present study was to develop a method for assessing the chronological age of Korean adults based on the relationship between age and size of pulp cavity using dental radiographs of mandibular first molars. Methods: A total of 325 dental radiographs of Korean adults with known age and gender were selected for the study (199 males and 126 females) which were taken in the period between January 2009 and June 2014 at the Pusan National University Dental Hospital. The measurements were carried out on both orthopantomographs (OPGs) and intraoral periapical radiographs of mandibular first molar and the following ratios were calculated: pulp chamber floor height ratio (F/L), pulp chamber ceiling height ratio (R/L), and pulp chamber depth ratio (D/L). Results: The ratios of measurements on intraoral periapical images of mandible first molar generally produce more reliable data than the measurements on OPGs. The pulp chamber floor height ratio and pulp chamber thickness ratio showed significant correlation with age, whereas the pulp chamber ceiling height ratios showed weak correlation with age. It was found that the best correlations between the ratios and age were found for pulp chamber thickness ratios (r=-0.731 to -0.751). The multiple regression models were derived using 3 ratios that were significantly correlated with age. The determination coefficients ($R^2$) of the models ranged from 0.556 to 0.596. Conclusions: Our results indicate that the pulp chamber thickness and pulp chamber floor height in mandibular first molar are an age-dependent variable in adults which can be used to estimate age with reasonable accuracy. The higher image quality of dental radiographs will probably narrow the age estimation error and improve dental age estimation.

Removal of residual VOCs in a collection chamber using decompression for analysis of large volatile sample

  • Lee, In-Ho;Byun, Chang Kyu;Eum, Chul Hun;Kim, Taewook;Lee, Sam-Keun
    • 분석과학
    • /
    • 제34권1호
    • /
    • pp.23-35
    • /
    • 2021
  • In order to measure the volatile organic compounds (VOCs) of a sample which is too large to use commercially available chamber, a stainless steel vacuum chamber (VC) (with an internal diameter of 205 mm and a height of 50 mm) was manufactured and the temperature of the chamber was controlled using an oven. After concentrating the volatiles of the sample in the chamber by helium gas, it was made possible to remove residual volatile substances present in the chamber under reduced pressure ((2 ± 1) × 10-2 mmHg). The chamber was connected to a purge & trap (P&T) using a 6 port valve to concentrate the VOCs, which were analyzed by gas chromatography-mass spectrometry (GC-MS) after thermal desorption (VC-P&T-GC-MS). Using toluene, the toluene recovery rate of this device was 85 ± 2 %, reproducibility was 5 ± 2 %, and the detection limit was 0.01 ng L-1. The method of removing VOCs remaining in the chamber with helium and the method of removing those with reduced pressure was compared using Korean drinking water regulation (KDWR) VOC Mix A (5 μL of 100 ㎍ mL-1) and butylated hydroxytoluene (BHT, 2 μL of 500 ㎍ mL-1). In case of using helium, which requires a large amount of gas and time, reduced pressure ((2 ± 1) × 10-2 mmHg) only during the GC-MS running time, could remove VOCs and BHT to less than 0.1 % of the original injection concentration. As a result of analyzing volatile substances using VC-P&T-GC-MS of six types of cell phone case, BHT was detected in four types and quantitatively analyzed. Maintaining the chamber at reduced pressure during the GC-MS analysis time eliminated memory effect and did not affect the next sample analysis. The volatile substances in a cell phone case were also analyzed by dynamic headspace (HT3) and GC-MS, and the results of the analysis were compared with those of VC-P&T-GC-MS. Considering the chamber volume and sample weight, the VC-P&T configuration was able to collect volatile substances more efficiently than the HT3. The VC-P&T-GC-MS system is believed to be useful for VOCs measurement of inhomogeneous large sample or devices used inside clean rooms.

Vacuum Characteristic of a Chamber Made of Mild Steel

  • Park, Chongdo;Ha, Taekyun;Cho, Boklae
    • Applied Science and Convergence Technology
    • /
    • 제24권4호
    • /
    • pp.84-89
    • /
    • 2015
  • The base pressure and outgassing rate of a mild steel chamber were measured and compared to those of a stainless steel chamber. A combined sputter-ion and non-evaporable getter pump with a nominal pumping speed of 490 l/s generated the base pressure of $2.7{\times}10^{-11}$ mbar in the mild steel chamber and $1.2{\times}10^{-10}$ mbar in the stainless steel chamber. The rate-of-rise measurements show that the mild steel has an extremely low outgassing rate of $2.6{\times}10^{-13}$ mbar $ls^{-1}cm^{-2}$, which is about one-order of magnitude smaller than the outgassing rate of the stainless steels. Vacuum annealing of the mild steel at $850^{\circ}C$ reduced the outgassing rate further to $8.8{\times}10^{-14}$ mbar $ls^{-1}cm^{-2}$, which was comparable to the outgassing rate of a heat treated stainless steel for extreme-high vacuum use.