• Title/Summary/Keyword: a angle detector

Search Result 177, Processing Time 0.024 seconds

Comparison Study of Extensive Air Shower Simulations with COSMOS and CORSIKA

  • Roh, Soon-Young;Kim, Ji-Hee;Ryu, Dong-Su
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.70.2-70.2
    • /
    • 2011
  • Ultra-high energy cosmic rays(UHECRs) refer cosmic rays with energy above 1018eV. UHECR experiments have employed air shower simulations to quantify the properties of cosmic rays. Using COSMOS and CORSIKA, we have produced a library of over 15000 thinned extensive air shower(EAS) simulations with the primary energies ranging from 1018.5eV to 1020eV and the zenith angle of primary cosmic ray particles from 0 to 45 for proton and iron primaries. We have compared the results from CORSIKA and COSMOS. The comparison has shown perceptible differences in the ground distributions, longitudinal distributions, Calorimetric energy, and Xmax distributions. We have also measured the detector response evaluated using GEANT4 simulations. Here, we discuss S(800), i.e. the signal at a distance of 800 m from the shower core, as the primary energy estimator and present the lateral distribution function(LDF) with S(800).

  • PDF

Fluorescence-labelling for analysis of protein in starch using asymmetrical flow field-flow fractionation (AF4)

  • Yoo, Yeongsuk;Choi, Jaeyeong;Zielke, Claudia;Nilsson, Lars;Lee, Seungho
    • Analytical Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.1-9
    • /
    • 2017
  • Starch is a mixture of amylose (AMY) and amylopectin (AMP) which are different in physical properties such as molar mass (M), rms radius ($R_g$) and hydrodynamic diameter ($d_H$). The rheological and functional properties of starch are influenced by various factors including the molecular size, molar mass distribution (MD) and the concentration ratio of AMY and AMP. It is also important to analyze proteinaceous material in starch as they affect the flavor and texture of food to which starch is added. In this study, asymmetrical flow field-flow fractionation (AF4) was employed for separation and quantitation of AMY and AMP in starches (Amaranth, potato, taros and quinoa). AF4 was coupled with a multi-angle light scattering (MALS) and a refractive index (RI) detector for determination of the absolute M, MD and molecular structure. It was found that AMP has the M and $R_g$ ranging $3.7{\times}10^7{\sim}6.5{\times}10^8g/mol$ and 84 ~ 250 nm, respectively. Also the existence of branch was confirmed in higher M. In addition, proteinaceous material in starch was analyzed by AF4 coupled with a fluorescence detector (FS) after fluorescence-labeling. AF4-FS with fluorescence-labelling showed a potential for investigation on existence of proteinaceous material and the interaction between proteinaceous material and polysaccharide in starch.

Effects of Interface Soaking on Strain Modulation in InAs/GaSb Strained-Layer Superlattices (계면 흡착에 의한 InAs/GaSb 초격자의 응력변조 효과)

  • Shin, H.W.;Choe, J.W.;Kim, J.O.;Lee, S.J.;Kim, C.S.;Noh, S.K.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.1
    • /
    • pp.35-41
    • /
    • 2011
  • In this study, the interface soaking effect in InAs/GaAs strained-layer superlattice (SLS) on crystalline phase modulation has been analyzed by the x-ray diffraction (XRD) curve. The strain variation induced by As and/or Sb soaking was determined by the separation angle between the substrate peak and the 0th-order superlattice satellite peak in the XRD spectra. Contrated that the As/InAs soaking arises minor GaAs-like interfacial layer, the Sb/GaSb soaking induces InSb-like one. The Fourier-transformed curves of the Pendellosung interference oscillation shows that the optimum soaking times of As/InAs and Sb/GaSb are 2 sec and 12 sec, at which the highest crystallineity has, respectively. An anomalous twin-peak phenomenon that a satellite peak splits into two peaks was observed in the SLS structure co-soaked by As and Sb at InAs${\rightarrow}$GaSb interfaces. We suggest that it may be resulted from coexistence of two kinds crystalline phases of InAsSb and GaAsSb due to intermixing of In${\leftrightarrow}$Ga and Sb${\leftrightarrow}$As.

Digital PLL Control for Phase-Synchronization of Grid-Connected PV System (계통 연계형 태양광 발전 시스템의 위상 동기화를 위한 디지털 PLL 제어)

  • 김용균;최종우;김흥근
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.9
    • /
    • pp.562-568
    • /
    • 2004
  • The frequency and phase angle of the utility voltage are important in many industrial systems. In the three-phase system, they can be easily known by using the utility voltage vector. However, in the case of single phase system, there are some difficulties in detecting the information of utility voltage. In conventional system, the zero-crossing detection method is widely used, but could not obtain the information of utility voltage instantaneously. In this paper, the new digital PLL control using virtual two phase detector is proposed with a detailed analysis of single-phase digital PLL control for utility connected systems. The experimental results under various utility conditions are presented and demonstrate an excellent phase tracking capability in the single-phase grid-connected operation.

ASIC Design for Speed Sensor less Control of Indution Motor (유도전동기의 센서리스 속도제어 ASIC 설계)

  • Kim, S.J.;Lee, B.C.;Shin, Y.J.;Lee, I.H.;Kwon, Y.A.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1212-1214
    • /
    • 2001
  • In this paper ASIC design technique using VHDL is applied to MRAS based speed sensorless control of induction motor. ASIC for MRAS based speed sensorless control is designed through the description of speed estimator using FSM, stator voltage controller, flux angle detector, coordinate transformation, and inverter switching signal output. Finally the above system has been implemented on the FPGA (VERTEX XCV400HQ240). Simulation and experiment have been performed to verify the performance of the designed ASIC.

  • PDF

Study on Design and Characteristic Analysiy of 6/8 SRM (6/8극 SRM의 설계 및 특성해석에 관한 연구)

  • Sohn Ick-Jin;Oh Seok-Gyu;Hao Chen;Ahn Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.407-410
    • /
    • 2002
  • A three-phase 6/8 structure Switched Reluctance Motor drive, the construction of the stator and the rotor. in the motor, the scheme of the rotor position detector and the main circuit of the power converter are described. The range of the stator pole arc factor and the rotor pole arc factor of the motor are analyzed in the linear region. The optimum range of the stator pole arc factor and the optimum range of the turn-off angle of the main switches in the power converter are given with the 2-D finite element electro-magnetic field calculation of the motor and the nonlinear simulation. Test jesuits of the developed prototype are discussed.

  • PDF

Autonomous Navigation System of Mobile Robot Using Laser Scanner for Corridor Environment (레이저 스캐너를 사용한 이동로봇의 복도 자율 주행 시스템)

  • Park, Jong-Kwan;Park, Tae-Hyeong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.11
    • /
    • pp.1044-1049
    • /
    • 2015
  • This paper proposes an autonomous navigation system of mobile robots for indoor corridor environment. The system uses a laser scanner but does not use reflectors. The laser scanner measures the distance between robot and structures such as wall, pillar, and fixtures. Adaptive breakpoint detector and modified IEPF (iterative endpoint fit) are developed to find mark points from the distance data. The robot path for corridor is then generated using the angle histogram of the mark points. The experimental results are finally presented to show the effectiveness of the proposed method.

Ultrasonic Sensors for Steel Structure Inspection (강구조물(鋼構造物) 진단(診斷)을 위한 초음파(超音波) 센서)

  • Shin, Byoung-Churl
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.2
    • /
    • pp.170-176
    • /
    • 1998
  • The team mixed PbO, $ZrO_2$, $TiO_2$, $Nb_2O_5$ and $MnCO_3$, to make $Pb[(Zr_{0.54}\;Ti_{0.46})\;Nb_{0.005}]O_3+4%MnCO_3$. The electroded PZT ceramics were poled by 3 kV/mm at $110^{\circ}C$ for 600 s. We assembled the 0.4mm thick PZT slices into ultrasonic transducers. Central frequency of the probe is 5 MHz, which is proper to the thickness gauge for steel pipes and for flaw detector. The probe can detect a disk shape defect of 1mm diameter at 15cm deep in steel block. The new probe's Fresnel zone that the ultrasonic beam do not broaden is 13mm. Over the Fresnel zone, the ultrasonic beam spreads. Half of the beam spread angle of the probe is $4.3^{\circ}-4.6^{\circ}$. This probe can be used for the ultrasonic transducers for non-destructive testing of steel bridges.

  • PDF

Analysis on the Positional Accuracy of the Non-orthogonal Two-pair kV Imaging Systems for Real-time Tumor Tracking Using XCAT (XCAT를 이용한 실시간 종양 위치 추적을 위한 비직교 스테레오 엑스선 영상시스템에서의 위치 추정 정확도 분석에 관한 연구)

  • Jeong, Hanseong;Kim, Youngju;Oh, Ohsung;Lee, Seho;Jeon, Hosang;Lee, Seung Wook
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.143-152
    • /
    • 2015
  • In this study, we aim to design the architecture of the kV imaging system for tumor tracking in the dual-head gantry system and analyze its accuracy by simulations. We established mathematical formulas and algorithms to track the tumor position with the two-pair kV imaging systems when they are in the non-orthogonal positions. The algorithms have been designed in the homogeneous coordinate framework and the position of the source and the detector coordinates are used to estimate the tumor position. 4D XCAT (4D extended cardiac-torso) software was used in the simulation to identify the influence of the angle between the two-pair kV imaging systems and the resolution of the detectors to the accuracy in the position estimation. A metal marker fiducial has been inserted in a numerical human phantom of XCAT and the kV projections were acquired at various angles and resolutions using CT projection software of the XCAT. As a result, a positional accuracy of less than about 1mm was achieved when the resolution of the detector is higher than 1.5 mm/pixel and the angle between the kV imaging systems is approximately between $90^{\circ}$ and $50^{\circ}$. When the resolution is lower than 1.5 mm/pixel, the positional errors were higher than 1mm and the error fluctuation by the angles was greater. The resolution of the detector was critical in the positional accuracy for the tumor tracking and determines the range for the acceptable angle range between the kV imaging systems. Also, we found that the positional accuracy analysis method using XCAT developed in this study is highly useful and will be a invaluable tool for further refined design of the kV imaging systems for tumor tracking systems.

The Anode Heel Effect caused by changing the Angle of X-Ray Tube (X-선관 각도 변경에 따른 Anode Heel Effect)

  • Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.435-442
    • /
    • 2016
  • This study was an investigation of the anode heel effect caused by changing the angle of the x-ray tube. We established the following conditions for experimental measurements: 70 kV, 30 mAs, focus-detector distance of 100cm, and a collimator setting of $35{\times}43cm^2$. The measurement points were set up at the center of the collimator and extended to each side in intervals of 3.5cm, with points A1, A2, A3, A4, A5, A6 on the anode side and points C1, C2, C3, C4, C5, C6 on the cathode side. We measured the entrance surface dose from point A6 to point C6 with each point perpendicular to an x-ray tube. And we did the same when measuring different angles of the x-ray tube from 15 to 30 degrees for every point on the anode and cathode sides. Using perpendicular x-ray tube, we found that the entrance surface dose of the A5 point was three times higher than that of the C5 point. Thus, we conclude that if the anode side is placed near highly radiosensitive organs, then there will be less radiation exposure when using a perpendicular x-ray tube. When imaging using x-ray tube angles, an angle to the cathode side can reduce the gap of the entrance surface dose on both the anode and cathode sides. When imaging areas where there are differences in thickness between the upper and lower sides, the angle to the cathode side that is closer to the thicker area can reduce the gap of the entrance surface dose and capture a higher quality image.