• 제목/요약/키워드: Zone Control

검색결과 1,499건 처리시간 0.023초

Effect of Root Zone Cooling on Growth Responses and Tuberization of Hydroponically Grown 'Superior' Potato (Solanum tuberosum) in Summer

  • Chang, Dong-Chil;Jeong, Jin-Cheol;Lee, Yong-Beom
    • 생물환경조절학회지
    • /
    • 제15권4호
    • /
    • pp.340-345
    • /
    • 2006
  • A potato (Solanum tuberosum L. cv. Superior) cultivar was grown in aeroponic cultivation system to investigate the effect of root zone cooling in summer. Based on their nutrient uptake, growth responses, and tuberization, the possibilities for potato seed production were determined. Although shoot growth and early tuberization increased in the conventional non-cooling root zone system (root zone temperature of $25\pm2^{\circ}C$), stolen growth, photosynthesis, transpiration rate and number of tubers produced were higher in the cooling root zone system ($20\pm2^{\circ}C$) than in the non-cooling system. Increasing root zone temperature above $25^{\circ}C$ stimulated absorption of K more than T-N, P, Ca, Fe and Mn. On the other hand, root zone temperatures in the range of $20^{\circ}C$ to $25^{\circ}C$ did not affect Mg contents. The lower uptake and supply to leaves of T-N, Fe and Mn at the high root zone temperature promoted early tuberization and advanced haulm senescence. The results stress the importance of keeping root zone temperature to as low as below 20, particularly in summer under temperate Bone.

제연구역의 주요 매개 변수 및 누설 면적 변화를 고려한 차압 형성 관계 분석 (An Analysis on the Major Parameter and the Relations of Pressure Difference Effect of Leakage Area in the Smoke-Control Zone)

  • 유우준;고권현;사공성호;남준석;유홍선
    • 한국화재소방학회논문지
    • /
    • 제27권1호
    • /
    • pp.20-25
    • /
    • 2013
  • 본 연구에서 부속실 단독 가압 구조인 급기가압 제연설비의 성능 확보에 영향을 주는 주요 매개 변수를 분석하고 공급유량과 누설면적 변화에 따라서 풍도와 부속실 차압 형성 관계를 실험적으로 분석하였다. 이를 위해서 3층 규모의 총 10개의 구획공간으로 구성된 모형 구조물과 방화문의 개폐력 측정장치를 제작하였으며, 각 구획공간과 외기의 차압, 방연풍속을 측정하기 위한 제어 계측 장비를 구성하였다. 그 결과 댐퍼의 차압조절 범위가 45 Pa~55 Pa인 경우 공급유량과 부속실 차압 크기에 따라서 45 Pa 이하인 저압 영역, 45 Pa~55 Pa 구간인 차압조절 영역 그리고 55 Pa 이상인 과압 영역을 구분하였으며, 저압 영역에서는 부속실, 차압조절 영역에서는 부속실과 댐퍼 그리고 과압 영역 에서는 댐퍼의 누설면적이 차압 형성에 중요한 관계를 갖고 있는 것을 확인하였다.

헤드셋을 이용한 승용차 실내 저소음 영역의 생성 (Formation of the Quiet Zone in an Automobile using Headset)

  • 이철;김인수;홍석윤
    • 소음진동
    • /
    • 제7권2호
    • /
    • pp.301-310
    • /
    • 1997
  • This paper presents active noise control method to form the near-field quiet zone for passengers in an automobile. The actuator model including interior acoustic plant, speaker and amplifier is experimentally identified in forms of auto-regressive and moving average by means of least mean square algorithm, The digital controller is composed of the regulator and Kalman filter to be designed based on LQG (linear quadratic gaussian). If the actuator model is prefiltered with digital filter to be properly designed for concentrating control performance index on the frequency band of primary noise source, LQG design approach can be effectively applied for the design of headset controller. Experimental results demonstrate that near-field quiet zone showing about 10dB noise reduction at microphone position can be formed using the headset located at passenger seat.

  • PDF

흡음재 배치를 이용한 정숙 공간 형성 방법 (Quiet Zone Generation by Absorption Materials)

  • 남경욱;박주배;김양한
    • 소음진동
    • /
    • 제11권2호
    • /
    • pp.221-225
    • /
    • 2001
  • In order to make a quiet zone, one can consider various methods. Of the methods, this paper deals with the method using control materials such as absorption materials. This method controls sound fields by changing boundary conditions. First, this paper shows that the control material is essentially on the same road as active noise control (ANC) That is, we can consider the control material as the control source of ANC. However we cannot control the source strength. Second, this paper shows that the position of the control material is an important variable by a numerical simulation. And the strategy to optimize the position is addressed.

  • PDF

제연 TAB를 통한 철도 지하환승통로의 거실제연설비 성능평가 (A Performance Evaluation of Zone Smoke Control Systems for Railway Underground Transit Passage by Smoke Control TAB)

  • 설석균;김준환;박민석;오승민;안용철;최준호
    • 한국화재소방학회논문지
    • /
    • 제31권1호
    • /
    • pp.1-9
    • /
    • 2017
  • 본 연구에서는 거실제연설비가 설치된 철도 지하환승통로에 현장성능평가시험인 제연 TAB(Test, Adjusting, Balancing)를 실시하여, 제연설비 성능 확보에 미치는 영향을 분석하고 개선방안을 도출하였다. 제연 TAB는 지하환승통로의 제연설비 설계자료 분석, 제연덕트 누기테스트, 제연송풍기와 덕트의 풍량 및 풍속 측정, Smoke test로 나누어 진행되었다. 제연덕트 누기시험을 통해 누기율을 측정하여 덕트의 기밀성을 확인하였고, 흡입측 덕트 정압손실로 인한 제연풍량 부족의 문제점을 개선하여 송풍기의 성능을 확보하였다. 또한, Smoke test을 통해 예상제연구역별 제연댐퍼 동작 시 자연풍, 열차풍 영향으로 인한 문제점을 분석하고 개선하여 예상 제연구역 내 제연이 원활하게 이루어짐을 확인하였다.

광디스크 드라이브 시스템을 위한 비선형 Anti-shock 제어기 설계 (Anti-shock Controller Design for Optical Disk Drive Systems with a Nonlinear Controller)

  • 백종식;정정주
    • 제어로봇시스템학회논문지
    • /
    • 제11권9호
    • /
    • pp.741-749
    • /
    • 2005
  • This paper presents a nonlinear controller design for optical disk drive systems to improve anti-shock performance. The nonlinear anti-shock controller is added parallel to the original linear servo control loop. In the previous work, a dead-zone nonlinear element is used for the nonlinear controller and a PID control method is used for the linear controller. Although this parallel structure of the controller improves anti-shock performance, it has a narrow stability bound. In this paper, the dead-zone with saturation nonlinear element is proposed for the nonlinear controller. Since this nonlinear element improves stability margin, we can use higher slope gain of dead-zone than that of nonlinear controller using dead-zone only. In the linear controller design, it is shown that the lead-lag control has an improved stability margin over PID control. Numerical simulation results and experimental results show that the proposed method can get better performance to the external shock than previously proposed methods.

고온기 근권냉방방식에 따른 냉방효과와 토마토 생육 (Cooling Efficiency and Growth of Tomato as Affected by Root Zone Cooling Methods in Summer Season)

  • 이재한;권준국;권오근;최영하;박동금
    • 생물환경조절학회지
    • /
    • 제11권2호
    • /
    • pp.81-87
    • /
    • 2002
  • 근권냉방 방식에 따른 냉방 효율과 토마토 생육 특성을 검토하고자 XL냉수순환, 라디에이타 냉풍, 패드냉풍 및 대조구를 처리한 결과는 다음과 같다. 근권부 냉방온도는 공급수온이 17.8$^{\circ}C$일 때 XL 냉수순환구는 18.$0^{\circ}C$ 라디에이타 냉풍구는 27.2$^{\circ}C$, 패드 냉풍구는 20.3$^{\circ}C$였다. 배지 깊이와 시간대별 평균온도는 XL냉수순환구 22.8~24.7$^{\circ}C$. 라디에이타 냉풍구 22.7~24.2$^{\circ}C$, 패드 냉풍구 20.5~23.2$^{\circ}C$, 대조구 25.9~29.6$^{\circ}C$를 나타내어 냉방처리구가 대조구에 비해 5~6$^{\circ}C$더 낮았다. 토마토의 생육에 있어 엽장. 엽폭은 대조구에 비해 컸으며, 생체중 및 건물중의 경우에서도 비슷한 경향이었다 근활력에 있어 대조구는 45.0ug/g에 비해 근권냉방 처리구는 58.5-62.8 ug/g으로 높았으나. 근권냉방 처리구간에는 큰 차이가 없었다.

반도체용 저온 열처리로의 Flat Zone 확장 및 온도편차 감소에 관한 연구 (Study on the Flat Zone Expansion and Temperature Deviation Reduction of Low Temperature Furnace for Semiconductor Process)

  • 주강우;심승술;장혁;이유영;김광선
    • 반도체디스플레이기술학회지
    • /
    • 제13권4호
    • /
    • pp.83-90
    • /
    • 2014
  • This paper is about the yield rate of lower temperature furnace for wafer heat-treatment. The flat-zone that the temperature in furnace has uniform distribution specific area is the significant variable to the yield rate. In this study, we researched about the ways how to widen the flat zone in the furnace using CFD. As a result, we confirmed that the characteristic of the flat-zone was changed when SCU(Super Cooling Unit) was used. We considered temperature control with above.

공사구간 교대통행 동적제어 알고리즘 개발 (Development of Work Zone Traffic Control Algorithm for Two Lane Road)

  • 박현진;오철;문재필
    • 한국ITS학회 논문지
    • /
    • 제16권2호
    • /
    • pp.23-35
    • /
    • 2017
  • 교대통행은 2차로 도로에서 한 차로를 점용한 공사 시, 다른 한 차로를 교대로 사용하여 교통류를 처리하는 공사구간 교통관리기법이다. 신호수를 이용한 교대통행 교통관리 방안은 작업자의 안전문제와 방향별 통과 교통수요에 능동적으로 대처하는데 한계가 있다. 이런 잠재적 문제점을 해결하기 위한 하나의 방안으로 이동식 교대통행 운영시스템을 개발 적용하는 것이다. 본 연구에서는 이 시스템의 교통제어 기법을 개발하였다. 검지기에서 수집되는 방향별 교통량을 이용하여 공사구간 교대통행에 적용 가능한 교통제어 운영변수를 도출하고, 공사구간 내 차량의 존재 유무를 고려한 알고리즘을 설계하였다. 또한 교대통행 제어시스템의 운영효율성 극대화를 위하여 제어변수 최적화를 실시하였다. 최적화방안으로 유전알고리즘 기법을 적용하였으며, 적용 유무에 따른 지체시간을 산출하여 운영효율성을 평가하였다. 그 결과, 최적화를 시행했을 때 총 지체시간과 차량 한 대당 지체시간 모두 감소하는 것으로 나타났다. 본 연구에서 제시한 교대통행 동적제어 알고리즘을 통하여 교대통행 공사구간을 통과하는 차량에게 지체시간 감소효과를 기대할 수 있다.

전력선통신을 이용한 소규모 주택용 맞춤형 전력피크 제어시스템 개발 (Development of Adaptive Home Power Peak-Cut Control System Using Power Line Communication)

  • 김상동;박지호;김동완
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.219-226
    • /
    • 2016
  • In this paper, adaptive home power peak-cut control system is developed using PLC. The developed scheme provides monitoring of power usage, power peak-cut control and additional function. In test bed, zone is presented by bedroom, living room, kitchen and bathroom. And individual load is presented by lighting, heater and fan in zone. In developed scheme, zone control is implemented by single PLC modem. And individual load control is implemented by key-map table. In addition, power peak-cut control system S/W, which can perform setting of power peak, power peak-cut control and monitoring of power usage.