• 제목/요약/키워드: Zirconia surface

검색결과 396건 처리시간 0.027초

지르코니아의 표면 처리에 따른 전장용 세라믹과의 전단결합강도 (Influence of surface treatments on the shear bond strength between zirconia ceramic and zirconia veneering ceramics)

  • 안재석;이정환
    • 대한치과기공학회지
    • /
    • 제35권1호
    • /
    • pp.19-27
    • /
    • 2013
  • Purpose: The aim of this research was to evaluate the shear bond strength of different zirconia veneering ceramics with and without liner glass materials to yttria partially-stabilized tetragonal zirconia polycrystalline(Y-TZP). Methods: Five co mmercial zirconia veneering ceramics were used in this study, E-Max(EM), Creation ZI(CR), Cercon ceram kiss(CE), Triceram(TR) and Zirkonzahn ICE(ZI). All samples were prepared according to manufacturer's instructions. Experimental industrially manufactured Y-TZP ceramic blocks(diameter: 2.7 mm; height: 13.5 mm) were used in this study. Shear bond strength between zirconia ceramic coping and zirconia veneering ceramics were evaluated by the push-shear bond test. The fracture load data were analyzed using ANOVA and Scheffe's test(${\alpha}$=0.05). The fractured surfaces of zirconia core ceraimc and zirconia veneering ceramics were observed using a scanning electron microscope(SEM). Results: The mean shear bond strengths ranged from 20 MPa ($20.12{\pm}6.34$ MPa) to 66.6 MPa ($66.62{\pm}10.01$ MPa). The Triceram(TRG) showed the highest value and Creation ZI(CR) showed the lowest value. In all groups, Zirconia liner and glass material groups was significantly higher shear bond strength than without liner(P<0.05), with the exception of Cercon ceram kiss(CE)groups. Conclusion: Zirconia bonding materials may have the advantage of improved bond strength between zirconia ceramic core and veneering ceramics.

CeO$_2$ 도핑에 의한 불규칙 입자형상의 이트리아 안정화 지르코니아 제조 (Preparation of Yttria-stabilized Zirconia with Irregular Grain Shapes by Ceria Doping)

  • 이종국;강현희;김영정;김환
    • 한국세라믹학회지
    • /
    • 제35권12호
    • /
    • pp.1294-1300
    • /
    • 1998
  • Yttria-stabilized zirconia ceramics with irregular grain shapes and curved grain boundaries was prepared by ceria doping. The amount of ceria doped into zirconia compacts by a dipping method were at range of 2 to 20 mol% Irregular grain shapes and curved grain boundaries were formed only inspecimens doped with more than 8mol% cerial. Ceria-doped specimens showed large grain size and low sintered density compared with pure yttria-stabilized zirconia which was due to the increase in the contents of stabilizer and cubic phase. The amount of doped ceria was larger on the surface than the inside regions and therefore mi-crostructure and phase on the surface were different from those in the inside regions. Transgranular frac-ture mode was observed ion ceria doped specimens due to irregular large grain sizes.

  • PDF

Effect of different grinding burs on the physical properties of zirconia

  • Lee, Kyung-Rok;Choe, Han-Cheol;Heo, Yu-Ri;Lee, Jang-Jae;Son, Mee-Kyoung
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권2호
    • /
    • pp.137-143
    • /
    • 2016
  • PURPOSE. Grinding with less stress on 3Y-TZP through proper selection of methods and instruments can lead to a long-term success of prosthesis. The purpose of this study was to compare the phase transformation and physical properties after zirconia surface grinding with 3 different grinding burs. MATERIALS AND METHODS. Forty disc-shaped zirconia specimens were fabricated. Each Ten specimens were ground with AllCeramic SuperMax (NTI, Kahla, Germany), Dura-Green DIA (Shofu Inc., Kyoto, Japan), and Dura-Green (Shofu Inc., Kyoto, Japan). Ten specimens were not ground and used as a control group. After the specimen grinding, XRD analysis, surface roughness test, FE-SEM imaging, and biaxial flexural strength test were performed. RESULTS. After surface grinding, small amount of monoclinic phase in all experimental groups was observed. The phase change was higher in specimens, which were ground with Dura-Green DIA and AllCeramic SuperMax burs. The roughness of surfaces increased in specimens, which were ground with Dura-Green DIA and AllCeramic SuperMax burs than control groups and ground with Dura-Green. All experimental groups showed lower flexural strength than control group, but there was no statistically significant difference between control group and ground with Dura-Green DIA and AllCeramic SuperMax burs. The specimens, which were ground with Dura-Green showed the lowest strength. CONCLUSION. The use of dedicated zirconia-specific grinding burs such as Dura-Green DIA and AllCeramic SuperMax burs decreases the grinding time and did not significantly affect the flexural strength of zirconia, and therefore, they may be recommended. However, a fine polishing process should be accompanied to reduce the surface roughness after grinding.

In vitro shear bond strength between fluorinated zirconia ceramic and resin cements

  • Tanis, Merve Cakirbay;Akay, Canan;Akcaboy, Turgut Cihan;Sen, Murat;Kavakli, Pinar Akkas;Sapmaz, Kadriye
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권3호
    • /
    • pp.205-210
    • /
    • 2018
  • PURPOSE. The purpose of this study was to evaluate the efficiency of a gas-phase fluorination method under different fluorination periods through using two resin cements. MATERIALS AND METHODS. 84 zirconia specimens in dimensions of $5mm{\times}5mm{\times}2mm$ were prepared and surface treated with $50{\mu}m$ aluminum oxide particles or gas phase fluorination for 2 min, 5 min, or 10 min. One specimen in each group was surface analyzed under scanning electron microscope. The remaining specimens were bonded to composite cylinders in dimensions of 2 mm diameter and 3 mm high with Panavia SA Plus or Variolink N. Then, the specimens were stored in $37^{\circ}C$ distilled water for 24 hours and shear bond strength test was applied at a speed of 1 mm/min. RESULTS. The highest shear bond strength values were observed in the samples fluorinated for 5 minutes and cemented with Panavia SA Plus. Variolink N did not elicit any statistical differences between surface treatments. Panavia SA Plus resin cement and Variolink N resin cements featured statistically significant difference in shear bond strength values only in the case of 5 minutes of fluorination treatment. CONCLUSION. According to the results of this study, application of 5 minutes of fluorination with 10-methacryloyloxydecyl dihydrogen phosphate monomer (MDP) containing Panavia SA Plus resin cement increased the resin bond strength of zirconia. Fluorination of the zirconia surface using conventional resin cement, Variolink N, did not lead to an increase in bond strength.

Analysis of osteogenic potential on 3mol% yttria-stabilized tetragonal zirconia polycrystals and two different niobium oxide containing zirconia ceramics

  • Hein, Aung Thu;Cho, Young-Dan;Jo, Ye-Hyeon;Kim, Dae-Joon;Han, Jung-Suk
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권2호
    • /
    • pp.147-154
    • /
    • 2018
  • PURPOSE. This study was performed to evaluate the osteogenic potential of 3mol% yttria-stabilized tetragonal zirconia polycrystals (3Y-TZP) and niobium oxide containing Y-TZPs with specific ratios, new (Y,Nb)-TZPs, namely YN4533 and YN4533/Al20 discs. MATERIALS AND METHODS. 3Y-TZP, YN4533 and YN4533/Al20 discs (15 mm diameter and 1 mm thickness) were prepared and their average surface roughness ($R_a$) and surface topography were analyzed using 3-D confocal laser microscope (CLSM) and scanning electron microscope (SEM). Mouse pre-osteoblast MC3T3-E1 cells were seeded onto all zirconia discs and evaluated with regard to cell attachment and morphology by (CLSM), cell proliferation by PicoGreen assay, and cell differentiation by Reverse-Transcription PCR and Quantitative Real-Time PCR, and alkaline phosphatase (Alp) staining. RESULTS. The cellular morphology of MC3T3-E1 pre-osteoblasts was more stretched on a smooth surface than on a rough surface, regardless of the material. Cellular proliferation was higher on smooth surfaces, but there were no significant differences between 3Y-TZP, YN4533, and YN4533/Al20. Osteoblast differentiation patterns on YN4533 and YN4533/Al20 were similar to or slightly higher than seen in 3Y-TZP. Although there were no significant differences in bone marker gene expression (alkaline phosphatase and osteocalcin), Alp staining indicated better osteoblast differentiation on YN4533 and YN4533/Al20 compared to 3Y-TZP. CONCLUSION. Based on these results, niobium oxide containing Y-TZPs have comparable osteogenic potential to 3Y-TZP and are expected to be suitable alternative ceramics dental implant materials to titanium for aesthetically important areas.

Shear bond strength of veneering ceramic to coping materials with different pre-surface treatments

  • Tarib, Natasya Ahmad;Anuar, Norsamihah;Ahmad, Marlynda
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권5호
    • /
    • pp.339-344
    • /
    • 2016
  • PURPOSE. Pre-surface treatments of coping materials have been recommended to enhance the bonding to the veneering ceramic. Little is known on the effect on shear bond strength, particularly with new coping material. The aim of this study was to investigate the shear bond strength of veneering ceramic to three coping materials: i) metal alloy (MA), ii) zirconia oxide (ZO), and iii) lithium disilicate (LD) after various pre-surface treatments. MATERIALS AND METHODS. Thirty-two (n = 32) discs were prepared for each coping material. Four pre-surface treatments were prepared for each sub-group (n = 8); a) no treatment or control (C), b) sandblast (SB), c) acid etch (AE), and d) sandblast and acid etch (SBAE). Veneering ceramics were applied to all discs. Shear bond strength was measured with a universal testing machine. Data were analyzed with two-way ANOVA and Tukey's multiple comparisons tests. RESULTS. Mean shear bond strengths were obtained for MA ($19.00{\pm}6.39MPa$), ZO ($24.45{\pm}5.14MPa$) and LD ($13.62{\pm}5.12MPa$). There were statistically significant differences in types of coping material and various pre-surface treatments (P<.05). There was a significant correlation between coping materials and pre-surface treatment to the shear bond strength (P<.05). CONCLUSION. Shear bond strength of veneering ceramic to zirconia oxide was higher than metal alloy and lithium disilicate. The highest shear bond strengths were obtained in sandblast and acid etch treatment for zirconia oxide and lithium disilicate groups, and in acid etch treatment for metal alloy group.

Mechanical properties of zirconia after different surface treatments and repeated firings

  • Subasi, Meryem Gulce;Demir, Necla;Kara, Ozlem;Ozturk, A. Nilgun;Ozel, Faruk
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권6호
    • /
    • pp.462-467
    • /
    • 2014
  • PURPOSE. This study investigated the influence of surface conditioning procedures and repeated firings on monoclinic content and strength of zirconia before cementation. MATERIALS AND METHODS. Sintered bar-shaped zirconia specimens were subjected to no surface treatment (control), air abrasion, or grinding (n=21). Their roughness was evaluated using a profilometer, and microscope analysis was performed on one specimen of each group. Then, 2 or 10 repeated firings (n=10) were executed, the monoclinic content of specimens was analyzed by X-ray diffraction, and a three-point flexural strength test was performed. Surface roughness values were compared using one-way analysis of variance (ANOVA) and Tukey honestly significant difference (HSD) tests, the monoclinic content values were tested using Kruskal-Wallis and Mann-Whitney U tests, and the flexural strength values were tested using two-way ANOVA and Tukey HSD tests (P=.05). Spearman's correlation test was performed to define relationships among measured parameters. RESULTS. Surface-treated specimens were rougher than untreated specimens and had a higher monoclinic content (P<.005), and the relationship between roughness and monoclinic content was significant (P<.000). Neither surface treatment nor firing significantly affected the flexural strength, but Weibull analysis showed that for the air-abraded samples the characteristic strength was significantly lower after the $10^{th}$ firing than after the $2^{nd}$ firing. CONCLUSION. After firing, a negligible amount of monoclinic content remained on the zirconia surfaces, and rougher surfaces had higher monoclinic contents than untreated surfaces. Multiple firings could be performed if necessary, but the fracture probability could increase after multiple firings for rougher surfaces.

Microscopical and chemical surface characterization of CAD/CAM zircona abutments after different cleaning procedures. A qualitative analysis

  • Gehrke, Peter;Tabellion, Astrid;Fischer, Carsten
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권2호
    • /
    • pp.151-159
    • /
    • 2015
  • PURPOSE. To describe and characterize the surface topography and cleanliness of CAD/CAM manufactured zirconia abutments after steaming and ultrasonic cleaning. MATERIALS AND METHODS. A total of 12 ceramic CAD/CAM implant abutments of various manufacturers were produced and randomly divided into two groups of six samples each (control and test group). Four two-piece hybrid abutments and two one-piece abutments made of zirconium-dioxide were assessed per each group. In the control group, cleaning by steam was performed. The test group underwent an ultrasonic cleaning procedure with acetone, ethyl alcohol and antibacterial solution. Groups were subjected to scanning electron microscope (SEM) analysis and Energy-dispersive X-ray spectroscopy (EDX) to verify and characterize contaminant chemical characterization non- quantitatively. RESULTS. All zirconia CAD/CAM abutments in the present study displayed production-induced wear particles, debris as well as organic and inorganic contaminants. The abutments of the test group showed reduction of surface contamination after undergoing an ultrasonic cleaning procedure. However, an absolute removal of pollutants could not be achieved. CONCLUSION. The presence of debris on the transmucosal surface of CAD/CAM zirconia abutments of various manufacturers was confirmed. Within the limits of the study design, the results suggest that a defined ultrasonic cleaning process can be advantageously employed to reduce such debris, thus, supposedly enhancing soft tissue healing. Although the adverse long-term influence of abutment contamination on the biological stability of peri-implant tissues has been evidenced, a standardized and validated polishing and cleaning protocol still has to be implemented.

유-무기 하이브리드 코팅액 제조를 위한 지르코니아 표면의 소수화 개질 연구 (Study on the hydrophobic modification of zirconia surface for organic-inorganic hybrid coatings)

  • 이수;문성진;박정주
    • 한국응용과학기술학회지
    • /
    • 제34권2호
    • /
    • pp.260-270
    • /
    • 2017
  • 백색을 띄고 물리적 화학적으로 안정한 지르코니아는 열전도도가 낮고 강도와 인성, 내식성이 우수하여 단열재, 내화물과 같은 고온 재료와 각종 산업용 구조세라믹스에 사용되고 있다. 이러한 지르코니아를 낮은 경도 및 굴절률 등과 같은 단점을 가진 고분자 코팅제에 도입하게 되면 화학적, 전기적, 광학적인 특성이 향상된다. 이와 같이 유기 소재에 무기 소재를 혼합하여 사용하는 유-무기 하이브리드 코팅을 목적으로 본 연구에서는 지르코니아 표면에 trimethylchlorosilane(TMCS)과 hexamethyldisilazane(HMDZ)을 사용하여 실릴화반응을 통한 $-CH_3$기를 도입하여 소수성을 나노지르코니아 표면에 도입하였다. 소수화된 지르코니아 표면에서의 TMCS와 HMDZ에 의해 도입된 $Si-CH_3$의 존재는 FT-IR ATR spectroscopy를 통해 확인하였고, silicon 원소의 존재를 FE-SEM/EDS와 ICP-AES를 통해 확인하였다. 또한, 개질 전후의 지르코니아를 아크릴레이트 단량체에 분산하여 침강속도를 확인하여 분산성이 향상되는 것을 확인하였다. 지르코니아 입자의 크기 및 분포는 입도 분석기를 통해 확인하였으며, BET 분석을 통해 개질 반응 전후의 비표면적은 $18m^2/g$ 정도로 큰 변화가 없었다.

표면 개질된 지르코니아를 함유한 유-무기 하이브리드 코팅액으로 도포된 PET 필름의 특성 (Characterization of PET films coated with organic-inorganic hybrid coating system containing surface modified zirconia)

  • 이수;김상엽;김영준
    • 한국응용과학기술학회지
    • /
    • 제35권3호
    • /
    • pp.595-605
    • /
    • 2018
  • 최근 우수한 유연성과 화학적 안정성 등을 가진 고분자 수지와 우수한 기계적 성질 등을 나타내는 무기 재료로 이루어진 나노 복합 시스템으로써 유-무기 하이브리드 코팅 필름에 관한 연구가 활발히 진행되고 있다. 아크릴레이트 단량체로써 사용된 o-phenylphenoxyethyl acrylate (OPPEA)는 1.576의 높은 굴절률을 나타내고, Bisphenol A ethoxylate diacrylate (BAEDA)는 굴절률은 낮지만 경화된 고분자의 경도를 향상시킨다. 또한, 무기 소재로써 사용된 지르코니아는 산화지르코늄으로써 우수한 내구성과 광학특성 등을 나타낸다. 본 연구에서는 광학 특성을 향상시키기 위한 목적으로 아크릴레이트 단량체 중 BAEDA의 함량을 조절하여 필름을 제조한 뒤 연필 경도계와 아베굴절계를 이용하여 광학 특성 변화를 확인하였고, UV-vis spectrophotometer을 이용해 투과도를 비교하여 최적의 조건을 확립하였다. 그리고 실란 커플링제인 ${\gamma}$-methacryloxypropyltrimethoxysilane (MPS)를 사용하여 지르코니아를 소수화 처리하여 아크릴레이트 단량체에 대한 분산성을 향상시키고, 개질 전후의 물에 대한 분산성 변화를 조사하여 물에 대한 친화력이 감소하였음을 확인하였고, FT-IR ATR spectrophotometer를 통해 MPS에 의해 도입된 $1716cm^{-1}$에서의 에스터 C=O 결합 peak의 존재를 통해 MPS에 의한 지르코니아 표면의 개질 반응이 진행되었음을 확인하였다. 또한, 지르코니아의 표면에 도입된 규소 원자의 존재는 X 선 형광법을 이용하여 확인하였다. 그리고 화학적으로 개질된 지르코니아를 아크릴레이트 단량체에 도입하여 광경화 필름을 제조하였을 때, 굴절률은 아크릴레이트 자체 필름보다 1.2% 향상되었음을 확인하였고, SEM/EDS mapping 분석을 통해 PET 필름에 코팅된 개질 후 지르코니아가 아크릴레이트 코팅층에 균일하게 분포되어 있음을 알 수 있었다.