• Title/Summary/Keyword: Zirconia implant

Search Result 158, Processing Time 0.023 seconds

The effects of physical decontamination methods on zirconia implant surfaces: a systematic review

  • Tan, Nathan Chiang Ping;Khan, Ahsen;Antunes, Elsa;Miller, Catherine M;Sharma, Dileep
    • Journal of Periodontal and Implant Science
    • /
    • v.51 no.5
    • /
    • pp.298-315
    • /
    • 2021
  • Purpose: Peri-implantitis therapy and implant maintenance are fundamental practices to enhance the longevity of zirconia implants. However, the use of physical decontamination methods, including hand instruments, polishing devices, ultrasonic scalers, and laser systems, might damage the implant surfaces. The aim of this systematic review was to evaluate the effects of physical decontamination methods on zirconia implant surfaces. Methods: A systematic search was conducted using 5 electronic databases: Ovid MEDLINE, PubMed, Scopus, Web of Science, and Cochrane. Hand searching of the OpenGrey database, reference lists, and 6 selected dental journals was also performed to identify relevant studies satisfying the eligibility criteria. Results: Overall, 1049 unique studies were identified, of which 11 studies were deemed suitable for final review. Air-abrasive devices with glycine powder, prophylaxis cups, and ultrasonic scalers with non-metal tips were found to cause minimal to no damage to implantgrade zirconia surfaces. However, hand instruments and ultrasonic scalers with metal tips have the potential to cause major damage to zirconia surfaces. In terms of laser systems, diode lasers appear to be the most promising, as no surface alterations were reported following their use. Conclusion: Air-abrasive devices and prophylaxis cups are safe for zirconia implant decontamination due to preservation of the implant surface integrity. In contrast, hand instruments and ultrasonic scalers with metal tips should be used with caution. Recommendations for the use of laser systems could not be fully established due to significant heterogeneity among included studies, but diode lasers may be the best-suited system. Further research-specifically, randomised controlled trials-would further confirm the effects of physical decontamination methods in a clinical setting.

Sintered Properties and Microstructural Defects of Zirconia Ceramic Implant Fabricated by Injection Molding and Hot Isostatic Pressing (HIP) (사출성형 및 열간가압 소결법으로 제작된 지르코니아 세라믹 임플란트의 소결물성 및 미세구조적 결함)

  • Hyun Jung Park;Jeong Sik Park;Jong Kook Lee
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.36 no.4
    • /
    • pp.215-222
    • /
    • 2023
  • 3Y-TZP (3 mol% yttria-stabilized tetragonal zirconia polycrystals, 3Y-TZP) ceramics are emerging as dental implant materials due to their superior optical and mechanical properties as well as excellent biophysical properties, in spite of low bioactivity. In this study, we investigated to sintered properties and microstructural defects of dental zirconia implants fabricated by ceramic injection molding and post-HIP (Hot isostatic pressing) processing and analyzed the processing parameters related with the obtainment of its high sinterd density. Sintered and microstructural parameters, i.e, apparent density, grain size and phase composition of zirconia implants fabricated by injection molding were dependent on the fixtute size and implant type. Maximum sintered density of 99.2% and minimum grain size of 0.3-0.4 ㎛ were obtained from large-scaled 2-body sample. In 1-body ceramic implant, high sintered density of 99.5% was obtained, but it had a little monoclinic phase and wide grain size distribution.

Maxillary cement retained implant supported monolithic zirconia prosthesis in a full mouth rehabilitation: a clinical report

  • Sadid-Zadeh, Ramtin;Liu, Perng-Ru;Aponte-Wesson, Ruth;O'Neal, Sandra J.
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.2
    • /
    • pp.209-217
    • /
    • 2013
  • This clinical report presents the reconstruction of a maxillary arch with a cement retained implant supported fixed prosthesis using a monolithic zirconia generated by CAD/CAM system on eight osseointegrated implants. The prosthesis was copy milled from an interim prosthesis minimizing occlusal adjustments on the definitive prosthesis at the time of delivery. Monolithic zirconia provides high esthetics and reduces the number of metal alloys used in the oral cavity.

An evaluation of the stress effect of different occlusion concepts on hybrid abutment and implant supported monolithic zirconia fixed prosthesis: A finite element analysis

  • Yesilyurt, Nilgün Gulbahce;Tuncdemir, Ali Riza
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.4
    • /
    • pp.216-225
    • /
    • 2021
  • PURPOSE. The aim of this study is to evaluate the effects of canine guidance occlusion and group function occlusion on the degree of stress to the bone, implants, abutments, and crowns using finite element analysis (FEA). MATERIALS AND METHODS. This study included the implant-prosthesis system of a three-unit bridge made of monolithic zirconia and hybrid abutments. Three-dimensional (3D) models of a bone-level implant system and a titanium base abutment were created using the original implant components. Two titanium implants, measuring 4 × 11 mm each, were selected. The loads were applied in two oblique directions of 15° and 30° under two occlusal movement conditions. In the canine guidance condition, loads (100 N) were applied to the canine crown only. In the group function condition, loads were applied to all three teeth. In this loading, a force of 100 N was applied to the canine, and 200-N forces were applied to each premolar. The stress distribution among all the components of the implant-bridge system was assessed using ANSYS SpaceClaim 2020 R2 software and finite element analysis. RESULTS. Maximum stress was found in the group function occlusion. The maximum stress increased with an increase in the angle of occlusal force. CONCLUSION. The canine guidance occlusion with monolithic zirconia crown materials is promising for implant-supported prostheses in the canine and premolar areas.

Surface Compatibility and Electrochemical Behaviors of Zirconia Abutment for Prosthodontics (보철용 지르코니아 어버트먼트의 표면적합도와 전기화학적 거동)

  • Park, K.H.;Jeong, Y.H.;Kim, W.G.;Choe, H.C.;Kim, M.S.
    • Journal of the Korean institute of surface engineering
    • /
    • v.42 no.1
    • /
    • pp.41-46
    • /
    • 2009
  • The fit between dental implant fixture and zirconia abutment is affected by many variables during the fabrication process by CAD/CAM program and milling working. The purpose of this study was to evaluate the surface compatibility and electrochemical behaviors of zirconia abutment for prosthodontics. Zirconia abutments were prepared and fabricated using zirconia block and milling machine. For stabilization of zirconia abutments, sintering was carried out at $1500^{\circ}F$ for 7 hrs. The specimens were cut and polished for gap observation. The gap between dental implant fixture and zirconia abutment was observed using field-emission scanning electron microscopy (FE-SEM). The hardness and corrosion resistance of zirconia abutments were observed with vickers hardness tester and potentiostat. The gap between dental implant fixture and zirconia abutment was $5{\sim}12{\mu}m$ for small gap, and $40{\sim}60{\mu}m$ for large gap. The hardness of zirconia surface was 1275.5 Hv and showed micro-machined scratch on the surface. The corrosion potentials of zirconia abutment/fixture was .290 mV and metal abutment/fixture was .280 mV, whereas $|E_{pit}-E_{corr}|$ of zirconia abutment/fixture (172 mV) was higher than that of metal abutment/fixture (150 mV). The corrosion morphology of metal abutment/fixture showed the many pit on the surface in compared with zirconia abutment/fixture.

Effects of abutment angulation and type of connection on the fracture strength of zirconia abutments (지대주 각도와 연결방식이 지르코니아 지대주의 파절강도에 미치는 영향)

  • Kim, Ho-Seong;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.9-17
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the fracture strength of straight and angled zirconia abutments for internal hex and external hex implants. Materials and methods: Twenty internal hex implants and 20 external hex implants were prepared. The prefabricated straight zirconia abutments and 17-degree-angled zirconia abutments were connected to those 40 implants. The specimens were classified into 4 groups depending on the connection type and abutment angulation; internal hex implant/straight abutment, group INS; internal hex implant/angled abutment, group INA; external hex implant/straight abutment, group EXS; external hex implant/angled abutment, group EXA. All specimens were loaded at a 30-degree angle with a crosshead speed of 1 mm/min using universal testing machine. The fracture loads were analyzed using 2-way ANOVA and independent t-test (${\alpha}=.05$). Results: The mean fracture load for INS was 955.91 N, 933.65 N for INA, 1267.20 N for EXS, and 1405.93 N for EXA. External hex implant showed a significantly higher fracture load, as compared to internal hex implant (P < .001). No significant differences in fracture loads were observed between the straight and angled abutment in internal hex implants (P = .747) and external hex implants (P = .222). Internal hexes of abutments were fractured horizontally in internal connection implants, while lingual cervical neck portions were fractured in external connection implants. Conclusion: The zirconia abutments with external hex implants showed significantly higher fracture strength than those with internal hex implants. However there was no difference in fracture strength between the straight and 17-degree-angled zirconia abutment connected to both implant systems.

A clinical consideration of current dental zirconia CAD/CAM restorations (최근 치과용 지르코니아 CAD/CAM 수복물의 임상적 고찰)

  • Lee, Hae-Hyoung
    • The Journal of the Korean dental association
    • /
    • v.49 no.5
    • /
    • pp.279-285
    • /
    • 2011
  • Currently there is no dental ceramic material can be used in all dental situations need to be restored. However, in view of recent clinical reports, the most viable alternative is zirconia ceramic. Clinical success of dental zirconia restorations strongly depends on proper selection of materials, accurate laboratory procedure and final cementation, which can be achievable with the correct understanding of zirconia. As dental materials, zirconia ceramics have a very bright future, because they are being used increasingly in the anterior region as implant fixtures, as well as crown and bridge restorations and implant abutments. Many dental ceramics showing poor clinical performance have been gone from the dental market. However, in terms of outstanding mechanical properties and esthetic nature, new dental materials can replace zirconia ceramics will not be available in the foreseeable future.

Bio-hybrid dental implants prepared using stem cells with β-TCP-coated titanium and zirconia

  • Safi, Ihab Nabeel;Hussein, Basima Mohammed Ali;Al-Shammari, Ahmed Majeed
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.3
    • /
    • pp.242-257
    • /
    • 2022
  • Purpose: This study investigated periodontal ligament (PDL) restoration in osseointegrated implants using stem cells. Methods: Commercial pure titanium and zirconium oxide (zirconia) were coated with beta-tricalcium phosphate (β-TCP) using a long-pulse Nd:YAG laser (1,064 nm). Isolated bone marrow mesenchymal cells (BMMSCs) from rabbit tibia and femur, isolated PDL stem cells (PDLSCs) from the lower right incisor, and co-cultured BMMSCs and PDLSCs were tested for periostin markers using an immunofluorescent assay. Implants with 3D-engineered tissue were implanted into the lower right central incisors after extraction from rabbits. Forty implants (Ti or zirconia) were subdivided according to the duration of implantation (healing period: 45 or 90 days). Each subgroup (20 implants) was subdivided into 4 groups (without cells, PDLSC sheets, BMMSC sheets, and co-culture cell sheets). All groups underwent histological testing involving haematoxylin and eosin staining and immunohistochemistry, stereoscopic analysis to measure the PDL width, and field emission scanning electron microscopy (FESEM). The natural lower central incisors were used as controls. Results: The BMMSCs co-cultured with PDLSCs generated a well-formed PDL tissue that exhibited positive periostin expression. Histological analysis showed that the implantation of coated (Ti and zirconia) dental implants without a cell sheet resulted in a well-osseointegrated implant at both healing intervals, which was confirmed with FESEM analysis and negative periostin expression. The mesenchymal tissue structured from PDLSCs only or co-cultured (BMMSCs and PDLSCs) could form a natural periodontal tissue with no significant difference between Ti and zirconia implants, consequently forming a biohybrid dental implant. Green fluorescence for periostin was clearly detected around the biohybrid implants after 45 and 90 days. FESEM showed the invasion of PDL-like fibres perpendicular to the cementum of the bio-hybrid implants. Conclusions: β-TCP-coated (Ti and zirconia) implants generated periodontal tissue and formed biohybrid implants when mesenchymal-tissue-layered cell sheets were isolated from PDLSCs alone or co-cultured BMMSCs and PDLSCs.

Submucosal zirconia implant prosthesis fabricated with CAD/CAM (CAD/CAM으로 제작한 점막하 지르코니아 임플란트 보철 수복 증례)

  • Chang, Jae-Seung;Kim, Sunjai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.352-358
    • /
    • 2014
  • They have been recently introduced many aesthetic implant prosthesis using with zirconia and CAD/CAM. However, there are many limitations in their gingival and occlusal region. In this case, submucosal zirconia implant prosthesis were fabricated with CAD/CAM system. The connection of these screw cement retained prosthesis and titanium abutment was designed to 1mm above the fixture. The clinical results were satisfactory on the aesthetics and function.

Considerations and clinical appliances of various abutments in implant prostheses (임플란트 보철 치료에서 지대주 선택시 고려사항과 임상적 적용)

  • Park, Sungwoo;Kim, Sunjai;Chang, Jae-Seung
    • The Journal of the Korean dental association
    • /
    • v.54 no.3
    • /
    • pp.191-197
    • /
    • 2016
  • In the past, restoration of implant crown, ready-made abutment produced by implant manufacturer could only be used. Using straight, angled abutment, there was a limit in adaptation multiple implants. Recently, with the development of implant and CAD/CAM technology, CAD/CAM customized abutment use has become possible which is different from the past when restoration was possible with only prefabricated abutment. Not only it makes emergence profile possible which is similar to natural teeth, but also it makes insertion path possible on CAD in multiple implant restorations. However, on anterior teeth which dental esthetics is very important, another restorations which are formed with natural colored gingiva area could be required. Titanium-based zirconia prostheses which have titanium connection and zirconia structure from 1mm above fixture platform are alternative. Therefore, the purpose of this review is to analyze the characteristics, advantages and disadvantages of the abutment which is used in multiple implant restorations, and to choose right abutment when clinical trials.

  • PDF