• Title/Summary/Keyword: Zirconia fixed partial denture

Search Result 17, Processing Time 0.019 seconds

Full mouth rehabilitation utilizing implant-assisted removable partial denture with a canted occlusal plane: a case report (경사진 교합평면을 갖는 환자에서 임플란트 보조 국소의치를 이용한 전악 수복 증례)

  • Han, A-Reum;Kwon, Tae-Min;Kim, Kyoung-A;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.214-223
    • /
    • 2016
  • Implant-assisted removable partial denture (Implant-assisted RPD, IARPD), posterior edentulous extension areas of which obtains additional support and retention from implants, is attracting increasing interest. This case report presents a successful treatment on a partially edentulous patient with a severely canted occlusal plane resulted from a long-term use of posterior extended RPD. The full mouth was rehabilitated through a fixed prosthesis on maxilla and IARPD with zirconia occlusal surface on mandible, which allowed to achieve an esthetic occlusal plane with long-term stability and, ultimately, functionally satisfying outcome.

Observation of Fracture Strengths According to the Core Materials for All Ceramic Bridge (전부도재교의치의 코어재료에 따른 파절강도 관찰)

  • Chung, In-Sung;Kim, Chi-Young
    • Journal of Technologic Dentistry
    • /
    • v.32 no.4
    • /
    • pp.351-356
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate the fracture strength between the core and veneering ceramic according to 2 core materials, In-Ceram Alumina and In-Ceram Zirconia, fabricated by electro ceramic layering technique. 2 different fixed partial denture cores of three units were veneered by veneering ceramic(Ceranion, Noritake) (n=10). Methods: The fracture strengths between the core and veneering ceramic were measured through the 3 point bending test. The interfaces between the core and veneering ceramic were observed with the X-ray dot mapping of EPMA. Results: The result of fracture strength was observed that IZP group, In-Ceram Zirconia core, had higher fracture strength. IPA group, In-Ceram Alumina core, had fracture strength of 359.9(${\pm}$86.2) N. IZP group, In-Ceram Zirconia core, had fracture strength of 823.2(${\pm}$243.0) N. X-ray dot mapping observation showed that a major element in the core and veneering ceramic of IPA group was alumina and silica, respectively. No binder was observed in interfaces between the core and veneering ceramic, and no ion diffusion or transition was observed between the core and veneering ceramic. However, apparent ion diffusion or transition was observed between the core and veneering ceramic of IZP group.

Fracture Strength of All-Ceramic 3-Unit Fixed Partial Dentures Manufactured by CAD/CAM and Copy-Milling Systems (CAD/CAM 및 카피밀링 시스템을 이용하여 제작한 구치부 3-유닛 고정성 국소의치의 파절강도)

  • Kang, Hoo-Won;Kim, Hee-Jin;Kim, Jang-Ju;Ko, Myung-Won
    • Journal of Technologic Dentistry
    • /
    • v.34 no.2
    • /
    • pp.95-103
    • /
    • 2012
  • Purpose: Fracture strength of all-ceramic 3-unit fixed partial dentures manufactured by CAD/CAM and copy-milling systems were evaluated. Methods: Zirconia cores were made by milling the pre-sintered zirconia block by CAD/CAM or copy milling method followed by subsequent sintering. By building-up the corresponding porcelains on the core, all-ceramic bridges were fabricated, and those were evaluated in comparison with PFM fixed partial denture. Results: During the flexural test of the 3-unit PFM bridge, the porcelain started to chip or break at 507.28(${\pm}62.82$)kgf and the metal framework did not break until the maximum load level of 800kgf which was set in the testing instrument of this study. However, among all-ceramic restoration test groups, Everest(EV) group showed a peeling off or breakage of the porcelain from 365.64(${\pm}64.96$)kgf and the core was broken at 491.77(${\pm}55.62$)kgf. Those values of Zirkonzahn(ZR) were 431.03(${\pm}58.47$)kgf and 602.74(${\pm}48.44$)kgf, respectively. The break strength of the porcelain of PFM(PM) group was significantly higher than that of EV (p<0.05) group and there was no significant difference when comparing to that of ZR (p>0.05). ZR group showed higher break strength than that of EV group however there was no significant difference (p>0.05). The break strength of cores were in the increasing order of EV < ZR < PM (p<0.05). Conclusion: We could find that even though the PM group fractured at much higher value than all-ceramic cores, the breakage values of the porcelain of PM group with crack formation or delamination, which will be regarded as clinical failure, was significantly higher than that of EV group and not significantly higher than that of ZR group at p-values of 0.05. The break strength of ZR group was higher than that of EV group at an insignificant level(p>0.05).

Full mouth rehabilitation utilizing computer guided implant surgery and CAD/CAM (Computer guided implant surgery와 CAD/CAM을 활용한 전악 수복 증례)

  • Kim, Sungjin;Han, Jung-Suk;Kim, Sung-Hun;Yoon, Hyung-In;Yeo, In-Sung Luke
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.1
    • /
    • pp.57-65
    • /
    • 2019
  • Computer aided design and manufacturing and implant surgery using a guide template improve restoration-driven implant treatment procedures. This case utilized those digital technologies to make definitive prostheses for a patient. According to the work flow of digital dentistry, cone beam computed tomography established the treatment plan, which was followed to make the guide template for implant placement. The template guided the implants to be installed as planned. The customized abutments and surveyed fixed restorations were digitally designed and made. The metal framework of the removable partial denture was cast from resin pattern using an additive manufacturing technique, and the artificial resin teeth were replaced with the zirconia onlays for occlusal stability. These full mouth rehabilitation procedures provided functionally and aesthetically satisfactory results for the patient.

Full mouth rehabilitation of a partially edentulous patient with crossed occlusion using implant-retained RPD with zirconia occlusal table (엇갈린 교합을 가진 부분 무치악 환자에서 지르코니아 교합면을 가지는 Implant-Retained RPD 이용한 전악 수복 증례)

  • Kwon, Tae-Min;Seo, Chi-Won;Kim, Kyung-A;Ahn, Seung-Geun;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.4
    • /
    • pp.314-321
    • /
    • 2016
  • Conventional removable partial dentures (RPDs) with distal extensions are associated with some problems, including lack of stability that calls for frequent relining, and cantilever actions of claps that can produce excessive loading to abutment teeth, and the need for unesthetic retentive arm clasps. Therefore, IARPDs (Implant-assisted RPD) that use implants to support or retain RPDs has been reported to improve stability, esthetics and masticatory performance of RPDs. Also, an IARPD that has zirconia occlusal table can prevent the incongruity of occlusal plane and the extrusion of antagonistic tooth. In this case of partially edentulous patient with crossed occlusion, each edentulous area was restored with implant fixed prosthesis and implant retained partial denture to suit each situation. Through the procedure, satisfactory outcomes were achieved both in functional and esthetic aspects.

THE EFFECT OF CASTING MACHINE AND INVESTMENT ON THE CASTABILITY OF TITANIUM ALLOY (주조기와 매몰재의 성분변화에 따른 티타늄의 주조성에 관한 연구)

  • Chung, Da-Woon;Yang, Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.654-664
    • /
    • 2006
  • Statement of problem: There has been a eat interest in the use of titanium for fixed and removable prostheses in recent because of its excellent biocompatibility. However, the melting temperature and chemical reactivity of titanium necessities casting system different from those used in conventional casting. The current titanium casting systems are based on an electric-arc design for melting the metal in an argon atmosphere and its exclusive investment. Despite the new development in Ti casting system, inadequate mold filling and internal porosity are frequently observed casting defects. Purpose : The purposes of this study were to compare the castibility and reaction layer of the casting titanium under the two casting machines and their investment condition. Material and method: coping and machine-milled titanium coping according to the casting methods and the marginal configurations. The total 28 specimens were used, and these are divided into 4 groups according to 2 casting machines and 2 investments. The castings were analyzed using x-ray microanalysis and microhardness testing. The reaction layer between margin of titanium casting and the investments was observed and analyzed with scanning electron microscope. Result: 1. Castabiliy of casting titanium specimen was best in the group of centrifugal casting machine and Selevest $CB^{\circledR}$ and good that of Selevest CB and pressure differential casting machine, Rematitan plus and centrifugal casting machine, Rematitan plus and pressure differential casting machine in order. 2. There was no significanct correlation in titanium castability in respect of casting machine. However ANOVA indicated that Selevest $CB^{\circledR}$ groups had significantly better castability than Rematitan $plus^{\circledR}$ groups.(p<0.05) 3. There was a significant microhardness difference between centrifugal casting machine groups and pressure differential groups.(p<0.05) Titanium castings in centifugal groups had significantly harder than those in pressure differential groups. 4. The addition of zirconia decreased interfacial reactivity. Conclusion: above result revealed that of the castability of titanium casting specimens had little correlation in casting machines and was better in magnesia-based investment contained ZrO2 groups. However in order to practice casting titanium in clininic, its castability should be improved, also there should be more research on factor of castability so that long-span prothesis and removable partial denture metla frame may be casted completly.

Reestablishing the occlusal plane in full mouth rehabilitation patient, using Shilla system (전악수복환자에서 Shilla system을 이용한 교합평면 재구성 증례)

  • Yang, Min-Soo;Vang, Mong-Sook;Park, Sang-Won;Lim, Hyun-Phil;Yun, Kwi-Dug;Yang, Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.33-38
    • /
    • 2013
  • Occlusal plane is a sagittal expression of dental arch form, and it composes the shape of occlusion, which is one of the most important elements of Maxillo-oral system. In this case, vertical, horizontal coordinates of bionic-median-sagittal plane was produced in articulator, and to achieve relation of left and right position of upper, lower teeth and deficits in alveola, Shilla system was used to reconstruct occlusal plane. In this case, a 41 year-old male patient visited for fracture of 10 unit metal-ceramic fixed partial denture of upper anterior teeth and for overall treatment. Clinical, radiographical, model examination was held, full mouth rehabilitation was achieved by placing dental implant. Maxillo-oral relation was recorded using Gothic arch Tracer complex and were mounted. And for the next step, we estimated original occlusal plane using Shilla system. After analysis we produced diagnosis wax pattern. On the basis of this, radiography stent was manufactured and dental implant was placed, and temporary prosthesis was made by using diagnosis wax pattern. Cross mounting and anterior guiding table were performed in order to reproduce temporary restoration morphology and bite pattern, followed by final restoration made of all ceramic crown with zirconia coping. As stated above, appropriately esthetic and functional results can be seen in using Shilla system in diagnosis and treatment procedure of full mouth rehabilitation patient.