• 제목/요약/키워드: Zirconia all ceramic crown

검색결과 44건 처리시간 0.02초

지르코니아 단일구조 전부도재관의 파절강도 (FRACTURE STRENGTH OF ZIRCONIA MONOLITHIC CROWNS)

  • 정희찬
    • 대한치과보철학회지
    • /
    • 제44권2호
    • /
    • pp.157-164
    • /
    • 2006
  • Purpose: The purpose of this study was to compare the fracture strength of the zirconia monolithic all-ceramic crowns according to the thickness(0.5 mm, 0.8 mm, 1.1 mm) and IPS Empress II ceramic crown of 1.5 mm thickness. Material and method: Eight crowns for each of 3 zirconia crown groups were fabricated using CAD/CAM system(Kavo, Germany) and eight Empress II crowns were made from silicone mold and wax pattern. Each crown group was finished in accordance with the specific manufacturer s instruction. All crowns were luted to the metal dies using resin cement and mounted on the testing jig in a universal testing machine. The load was directed at the center of crown with perpendicular to the long axis of each specimen until catastrophic failure occurred. Analysis of variance and Tukey multiple comparison test(p<.05) were applied to the data. Results and Conclusion: 1. The fracture strength of the zirconia monolithic all-ceramic crown was higher thickness increased(p<.05). 2 The fracture strength of 1.1 mm thickness zirconia monolithic all-ceramic crown was higher than the fracture strength of 1.5 mm thickness IPS Empress II crown(p<.05). 3. The fracture strength of 0.5 mm thickness zirconia monolithic all-ceramic crown exceeded maximum occlusal forces.

심미도재관의 파절 강도 비교 연구 (A comparative study on the fracture strength of esthetic porcelain crowns)

  • 김은하;이명곤
    • 대한치과기공학회지
    • /
    • 제29권2호
    • /
    • pp.79-85
    • /
    • 2007
  • In this study, We tried to find out the fracture strength of zirconia coping all ceramic crown and collarless porcelain fused gold alloy crown as the compared group. Each of the collarless porcelain fused gold crown and zirconia all ceramic crown has been produced specimen 10 each. And after pasting them on the steel jig, it had load given at porcelain incisal edge by 130$^{\circ}$ and measured fracture strength by Universal Testing Machine and then We have results from that. 1. The average value of fracture strength suggested 950.49 N at collarless porcelain fused gold alloy crown, 656.81 N at zirconia coping all ceramic crown. 2. Fractured pattern showed that the whole of labial part was exposed in collarless porcelain fused gold crown, but porcelain of margin part did not show fracture in advance. In the practice, the concern that collarless might cause fracture strength to be weaken does not matter, we concluded zirconia all ceramic crown made fracture that only a part of labial porcelain was fractured. The combination of zirconia all ceramic crown and turned out to be excellent.

  • PDF

지르코니아 단일구조 전부도재관과 금속도재관의 파절강도 비교 (FRACTURE STRENGTH OF ZIRCONIA MONOLITHIC CROWNS AND METAL-CERAMIC CROWNS AFTER CYCLIC LOADING AND THERMOCYCLING)

  • 이상민;정희찬;전영찬
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.12-20
    • /
    • 2007
  • Purpose: The purpose of this study was to compare the fracture strength of the zirconia monolithic all-ceramic crowns according to the thickness (0.5mm, 0.8mm, 1.1mm) and metal-ceramic crowns (1.0mm, 1.5mm) Material and method: Twelve crowns for each of 3 zirconia crown groups were fabricated using CAD/CAM system (Kavo, Germany) and twelve crowns for each of 2 metal-ceramic crown groups were made by the conventional method. All crowns were luted to the metal dies using resin cement. Half of the specimens were exposed to thermocycling ($5-55^{\circ}C$, 1 Hz) and cyclic loading (300,000 cycles, 50N). Subsequently, all crowns were mounted on the testing jig in a universal testing machine. The load was directed at the center of crown with perpendicular to the long axis of each specimen until catastrophic failure occurred. Analysis of variance and Tukey multiple comparison test (P<.05) were used for statistical analysis of all groups, and paired t-test (P<.05) was followed for statistical comparison between each groups' fracture load before and after cyclic loading. Results: 1. The fracture strength of the zirconia monolithic crowns and the metal-ceramic crown increased as thickness increased (P<.05). 2. The cyclic loading and thermocycling significantly decreased the fracture strength of the zirconia monolithic crowns (P<.05). 3. The standard deviation of fracture strength of the zirconia monolithic crowns was very low. Conclusion: The fracture strength of the zirconia monolithic crowns for the posterior area tends to be higher with thickness increased and 0.8mm or over in thickness is recommended to have similar or over the fracture strength of metal-ceramic crowns.

치과용 지르코니아 블럭의 착색시간에 따른 색조변화 관찰 (Evaluation of Color Change According to Coloring Time of Dental Zirconia Block)

  • 최성민;남상용
    • 대한치과기공학회지
    • /
    • 제33권3호
    • /
    • pp.219-224
    • /
    • 2011
  • Purpose: The current study focused on investigating color change of dental zirconia block with respect to the block coloring time. Methods: Three types of dental zirconia blocks(Zirtooth, Pearl-HT, D-Max) were tinted with coloring agent under four different time condition (0 minutes, 1 minutes, 10 minutes, 30 minutes). The quantitative evaluation of the tinted dental zirconia blocks was conducted with spectrophotometer. Results: The Zirtooth and D-Max blocks showed lower H value. The Pearl-HT blocks showed poor reflectivity(L value). Conclusion: The study of color change of zirconia block, which consists the substructure of all ceramic Crown, is applicable for deciding appropriate coloring condition when fabricating one layer ceramic Crown or double layer ceramic Crown.

치아 부위에 따른 지르코니아 도재관의 파절강도 (Fracture strength of zirconia ceramic crowns according to tooth position)

  • 이인섭;김정미;동진근
    • 대한치과보철학회지
    • /
    • 제48권2호
    • /
    • pp.94-100
    • /
    • 2010
  • 연구목적: 본 연구는 상악과 하악의 각 치아부위에 $Lava^{TM}$ All-Ceramic System을 이용하여 지르코니아 전부도재관을 제작하고 각각의 파절강도를 알아보고자 하였다. 연구방법:중절치와 견치는 절단연의 삭제량을 2.0 mm, 소구치와 대구치는 교합면의 삭제량을 1.5 mm, 그리고 축면 경사도는 $8^{\circ}$로하여모두8군의 실험군을 설정하였다. 금속 다이와 지르코니아 도재관을 제작한 후 레진시멘트 (Rely $X^{TM}$ Unicem)를 이용하여 합착하고 만능시험기상에서 치아 장축에 $30^{\circ}$경사지게 하여 중절치와 견치에 제작된 지르코니아 도재관은 절단연 중앙 부위에 하중을 가하였고, 소구치와 대구치에 제작된 지르코니아 도재관은 기능교두의 협설측 경사면 중앙부위에 하중이 가해지도록 한 후 파절강도를 측정하였다. 결과:1. 지르코니아 도재관의 평균 파절강도는 하악 제1대구치에서 2963 N으로 가장 높게 나타났으며, 하악 중절치에서 1035 N으로 가장 낮게 나타났다. 2. 지르코니아 도재관과 IPS Empress 도재관과의 평균 파절강도는 모든 치아에서 지르코니아 도재관이 더 크게 나타났다. 3. 지르코니아 도재관의 파절 양상은 하중이 가해진 중앙 부위에서 치아 장축으로 수직적인 파절상을 보였다. 4. 상악과 하악의 동일 부위에 제작된 지르코니아 도재관의 파절강도는 소구치에서 상악이 하악에 비하여 낮은 것으로 나타났으며 (P< .05), 다른 부위에서는 유의한 차이가 없었다 (P> .05). 결론: 본 실험의 결과로 지르코니아 도재관은 임상에서 활용하기에 만족할 만한 강도를 갖고 있음을 알 수 있었다.

Effect of the shades of background substructures on the overall color of zirconia-based all-ceramic crowns

  • Suputtamongkol, Kallaya;Tulapornchai, Chantana;Mamani, Jatuphol;Kamchatphai, Wannaporn;Thongpun, Noparat
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권3호
    • /
    • pp.319-325
    • /
    • 2013
  • PURPOSE. The objective of this study was to determine the effect of the color of a background substructure on the overall color of a zirconia-based all-ceramic crown. MATERIALS AND METHODS. Twenty one posterior zirconia crowns were made for twenty subjects. Seven premolar crowns and six molar crowns were cemented onto abutments with metal post and core in the first and second group. In the third group, eight molar crowns were cemented onto abutments with a prefabricated post and composite core build-up. The color measurements of all-ceramic crowns were made before try-in, before and after cementation. A repeated measure ANOVA was used for a statistical analysis of a color change of all-ceramic crowns at ${\alpha}$=.05. Twenty four zirconia specimens, with different core thicknesses (0.4-1 mm) were also prepared to obtain the contrast ratio of zirconia materials after veneering. RESULTS. $L^*$, $a^*$, and $b^*$ values of all-ceramic crowns cemented either on a metal cast post and core or on a prefabricated post did not show significant changes (P>.05). However, the slight color changes of zirconia crowns were detected and represented by ${\Delta}E{^*}_{ab}$ values, ranging from 1.2 to 3.1. The contrast ratios of zirconia specimens were 0.92-0.95 after veneering. CONCLUSION. No significant differences were observed between the $L^*$, $a^*$, and $b^*$ values of zirconia crowns cemented either on a metal cast post and core or a prefabricated post and composite core. However, the color of a background substructure could affect the overall color of posterior zirconia restorations with clinically recommended core thickness according to ${\Delta}E{^*}_{ab}$ values.

The effect of zirconia framework design on the failure of all-ceramic crown under static loading

  • Urapepon, Somchai;Taenguthai, Pakamard
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권2호
    • /
    • pp.146-150
    • /
    • 2015
  • PURPOSE. This in vitro study aimed to compare the failure load and failure characteristics of two different zirconia framework designs of premolar crowns when subjected to static loading. MATERIALS AND METHODS. Two types of zirconia frameworks, conventional 0.5 mm even thickness framework design (EV) and 0.8 mm cutback of full contour crown anatomy design (CB), were made for 10 samples each. The veneer porcelain was added on under polycarbonate shell crown made by vacuum of full contour crown to obtain the same total thickness of the experiment crowns. The crowns were cemented onto the Cobalt-Chromium die. The dies were tilted 45 degrees from the vertical plane to obtain the shear force to the cusp when loading. All crowns were loaded at the lingual incline of the buccal cusp until fracture using a universal testing machine with cross-head speed 0.5 mm/min. The load to fracture values (N) was recorded and statistically analyzed by independent sample t-test. RESULTS. The mean and standard deviations of the failure load were $1,170.1{\pm}90.9$ N for EV design and $1,450.4{\pm}175.7$ N for CB design. A significant difference in the compressive failure load was found (P<.05). For the failure characteristic, the EV design was found only cohesive failures within veneering porcelain, while the CB design found more failures through the zirconia framework (8 from 10 samples). CONCLUSION. There was a significant difference in the failure load between two designs, and the design of the framework influences failure characteristic of zirconia crown.

Comparative fracture strength analysis of Lava and Digident CAD/CAM zirconia ceramic crowns

  • Kwon, Taek-Ka;Pak, Hyun-Soon;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.92-97
    • /
    • 2013
  • PURPOSE. All-ceramic crowns are subject to fracture during function. To minimize this common clinical complication, zirconium oxide has been used as the framework for all-ceramic crowns. The aim of this study was to compare the fracture strengths of two computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia crown systems: Lava and Digident. MATERIALS AND METHODS. Twenty Lava CAD/CAM zirconia crowns and twenty Digident CAD/CAM zirconia crowns were fabricated. A metal die was also duplicated from the original prepared tooth for fracture testing. A universal testing machine was used to determine the fracture strength of the crowns. RESULTS. The mean fracture strengths were as follows: $54.9{\pm}15.6$ N for the Lava CAD/CAM zirconia crowns and $87.0{\pm}16.0$ N for the Digident CAD/CAM zirconia crowns. The difference between the mean fracture strengths of the Lava and Digident crowns was statistically significant (P<.001). Lava CAD/CAM zirconia crowns showed a complete fracture of both the veneering porcelain and the core whereas the Digident CAD/CAM zirconia crowns showed fracture only of the veneering porcelain. CONCLUSION. The fracture strengths of CAD/CAM zirconia crowns differ depending on the compatibility of the core material and the veneering porcelain.

지대주 경사각이 지르코니아 전부도재관의 변연적합도에 미치는 영향 (The Effect of Abutment Inclined Angle on the Marginal Fit of Zirconia All-ceramic Crown)

  • 이서연;정인성;전병욱
    • 대한치과기공학회지
    • /
    • 제38권3호
    • /
    • pp.111-117
    • /
    • 2016
  • Purpose: The present study was performed to investigate the effect of abutment inclined angle on the marginal fit of zirconia all-ceramic crown. Methods: The Ti abutments with 3 different inclined angle($2^{\circ}$, $4^{\circ}$ and $6^{\circ}$) were fabricated. The zirconia copings were fabricated for each abutment by using dental CAD/CAM system. The manufactured zirconia copings were duplicated through silicone replica technique, and a replicated specimen was sectioned in the center of bucco-lingual and mesio-distal axial to measure the marginal fit by using a stereo microscope. The results were analyzed using a one-way ANOVA with SPSS 22.0 for Windows(${\alpha}=0.05$). Results: On the bucco-lingual axial, marginal fit was the RL3($41.5{\pm}3.4{\mu}m$), RL2($44.3{\pm}4.3{\mu}m$) and RL1($47.5{\pm}5.7{\mu}m$), respectively. On the mesio-distal axial, marginal fit was the RL3($41.1{\pm}3.7{\mu}m$), RL2($45.7{\pm}5.3{\mu}m$) and RL1($46.2{\pm}4.5{\mu}m$), respectively. One-way ANOVA showed statistically significant difference between groups for marginal fit(p<0.05). Conclusion: For marginal fit of the abutments inclined angle, RL3 specimen was superior. The abutment inclined angle had influence on marginal fit of the zirconia copings. The marginal fit of each group were within clinically acceptable range.

Influence of porcelain veneering on the marginal fit of Digident and Lava CAD/CAM zirconia ceramic crowns

  • Pak, Hyun-Soon;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun;Yang, Jae-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권2호
    • /
    • pp.33-38
    • /
    • 2010
  • PURPOSE. Marginal fit is a very important factor considering the restoration's long-term success. However, adding porcelain to copings can cause distortion and lead to an inadequate fit which exposes more luting material to the oral environment and causes secondary caries. The purpose of this study was to compare the marginal fit of 2 different all-ceramic crown systems before and after porcelain veneering. This study was also intended to verify the marginal fit of crowns originated from green machining of partially sintered blocks of zirconia (Lava CAD/CAM system) and that of crowns obtained through machining of fully sintered blocks of zirconia (Digident CAD/CAM system). MATERIALS AND METHODS. 20 crowns were made per each system and the marginal fit was evaluated through a light microscope with image processing (Accura 2000) at 50 points that were randomly selected. Each crown was measured twice: the first measurement was done after obtaining a 0.5 mm coping and the second measurement was done after porcelain veneering. The means and standard deviations were calculated and statistical inferences among the 2 groups were made using independent t-test and within the same group through paired t-test. RESULTS. The means and standard deviations of the marginal fit were $61.52{\pm}2.88{\mu}m$ for the Digident CAD/CAM zirconia ceramic crowns before porcelain veneering and $83.15{\pm}3.51{\mu}m$ after porcelain veneering. Lava CAD/CAM zirconia ceramic crowns showed means and standard deviations of $62.22{\pm}1.78{\mu}m$ before porcelain veneering and $82.03{\pm}1.85{\mu}m$ after porcelain veneering. Both groups showed significant differences when analyzing the marginal gaps before and after porcelain veneering within each group. However, no significant differences were found when comparing the marginal gaps of each group before porcelain veneering and after porcelain veneering as well. CONCLUSION. The 2 all-ceramic crown systems showed marginal gaps that were within a reported clinically acceptable range of marginal discrepancy.