• Title/Summary/Keyword: Zinc phosphate glass

Search Result 46, Processing Time 0.025 seconds

In vitro cytotoxicity of four kinds orthodontic band cements (수종 치과 교정용 밴드 시멘트의 세포독성에 관한 실험적 연구)

  • Lee, Won-Chul;Park, Soo-Byung
    • The korean journal of orthodontics
    • /
    • v.34 no.4 s.105
    • /
    • pp.351-362
    • /
    • 2004
  • Orthodontic band cements are widely used in the fields of orthodontics, but they are commonly known as cytotoxic material. Within an oral cavity several ions and components are released from orthodontic band cements, thus causing inflammation or injury to the Periodontal tissue. Therefore, it is very important to estimate the biocompatibility of orthodontic band cements. The purpose of this study was to assess the cytotoxic effect of orthodontic band cements to HGF cells. A zinc phosphate cement, a glass ionomer, a resin modified glass ionomer, and compomer were used to evaluate three cytotoxicity assays: cell proliferation assay, MTT assay, and agar ovelay assay The results were as follows: 1. In the cell proliferation assay, Gl>ZPC, RMGI, RMGI24, GI24>compomer24, ZPC24, compomer>metal ring lined up in order of cytotoxicity 2. In the MTT assay, GI>ZPC, RMGI>GI24>ZPC24, compomer, metal ring, RMGI24, compomer24 lined up in order of cytotoxicity. 3. In the agar overlay test, GI>GI24, ZPC, ZPC24, RMGI>RMGI24, compomer, compomer24, metal ring lined up in order of cytotoxicity.

Immobilization of Radioactive Rare Earth oxide Waste by Solid Phase Sintering (고상소결에 의한 방사성 희토류산화물의 고화)

  • Ahn, Byung-Gil;Park, Hwan-Seo;Kim, Hwan-Young;Lee, Han-Soo;Kim, In-Tae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.1
    • /
    • pp.49-56
    • /
    • 2010
  • In the pyroprocessing of spent nuclear fuels, LiCl-KCl waste salt containing radioactive rare earth chlorides are generated. The radioactive rare earth oxides are recovered by co-oxidative precipitation of rare earth elements. The powder phase of rare eath oxide waste must be immobilized to produce a monolithic wasteform suitable for storage and ultimate disposal. The immobilization of these waste developed in this study involves a solid state sintering of the waste with host borosilicate glass and zinc titanate based ceramic matrix(ZIT). And the rare-earth monazite which synthesised by reaction of ammonium di-hydrogen phosphate with the rare earth oxides waste, were immobilzed with the borosilicate glass. It is shown that the developed ZIT ceramic wasteform is highly resistant the leaching process, high density and thermal conductivity.

Comparison of the retention of the full veneer casted gold crowns with varying convergence angle, crown length and dental cements (수렴각과 치관 길이를 달리한 금속 다이상에서 치과용 시멘트 합착 후 전부주조관의 유지력 비교)

  • Yun, Jung-Ho;Cho, Jin-Hyung;Kim, Jee-Hwan;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.2
    • /
    • pp.99-106
    • /
    • 2013
  • Purpose: The aim of this research was to establish the effect and variation in differing convergence angle and length of abutment on the retention of full veneer casted gold crown. Materials and methods: Two different length,5 mm and 10 mm in height with convergence angles of 5, 10, 15 and 25 degrees crowns were fabricated. Cementation was done using cements; zinc phosphate cement (Fleck's zinc phosphate cement), resin-modified glass ionomer cement (Vitremer) and resin cement (Panavia 21). These were tested for tensile force at the point of separation by using Instron Universal Testing Machine. Statistical analysis was done by SAS 6.04 package. Results: In all cements the mean retention decreased with significant difference on increase of convergence angle (P<.05). Increase in every 5 degree-convergence angel the retention rate decreased with resin-modified glass ionomer cement of 15.9% and resin cement of 14.8%. With zinc phosphate cement, there was largest decreasing rate of mean retention of 25.5% between convergence angles from 5 degree to 10 degree. When the crown length increased from 5 mm to 10 mm, the retention increased with the significant difference in the same convergence angle and in all types of cement used (P<.05). Conclusion: The retention was strongly dependent on geometric factors of abutment. Much care is required in choosing cements for an optimal retention in abutments with different convergence angles and crown lengths.

Effect of adhesive luting on the fracture resistance of zirconia compared to that of composite resin and lithium disilicate glass ceramic

  • Lim, Myung-Jin;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • Objectives: The purpose of this study was to evaluate the effect of adhesive luting on the fracture resistance of zirconia compared to that of a composite resin and a lithium disilicate glass ceramic. Materials and Methods: The specimens (dimension: $2mm{\times}2mm{\times}25mm$) of the composite resin, lithium disilicate glass ceramic, and yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) were prepared. These were then divided into nine groups: three non-luting groups, three non-adhesive luting groups, and three adhesive luting groups, for each restorative material. In the non-luting groups, specimens were placed on the bovine tooth without any luting agents. In the non-adhesive luting groups, only zinc phosphate cement was used for luting the specimen to the bovine tooth. In the adhesive luting groups, specimens were pretreated, and the adhesive luting procedure was performed using a self-adhesive resin cement. For all the groups, a flexural test was performed using universal testing machine, in which the fracture resistance was measured by recording the force at which the specimen was fractured. Results: The fracture resistance after adhesive luting increased by approximately 29% in the case of the composite resin, 26% in the case of the lithium disilicate glass ceramic, and only 2% in the case of Y-TZP as compared to non-adhesive luting. Conclusions: The fracture resistance of Y-TZP did not increased significantly after adhesive luting as compared to that of the composite resin and the lithium disilicate glass ceramic.

THE INFLUENCE OF DENTIN DESENSITIZER TO SHEAR BOND STRENGTH OF DENIAL CEMENTS (상아질 지각완화제가 치과용 시멘트의 결합강도에 미치는 영향)

  • Na, Yun-Ho;Oh, Nam-Sik;Yoo, Jae-Heung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.579-588
    • /
    • 2007
  • Statement of problem: A tenderness of the dentin after tapering of teeth for dental prosthesis is a common phenomenon. In practice, the alternative desensitizer may be used for minor pain after tapering of teeth. Purpose: In this study, the desensitizers were used to investigate the affect decreasing of shear bond strength according to the use of various cement, such as resin, Glass Ionomer, and phosphate cement. Material and method: Three different desensitizers were used on this study Compositions of two dentin desensitizers were HEMA(hydroxyethylmethacrylate) and glutaraldehyde. The other one is oxalic acid. Three dentin desensitizers applied on 12 degrees taper teeth. Then, Ni-Cr crowns were bonded with Resin cement, Zinc Phosphate (ZPC) cement and Glass Ionomer (GIC) cement. 120 human premolar teeth were used for specimens. The specimens were divided into four group as the reference and the empirical each with thirty specimens, then further divided into 12 group according to type of desensitizers and cement types. The shear bond strength were measured by Instron multi task instrument. Results: According to the result, the measured shear bond strength in order from the weakest to the strongest in general was ZPC, Resin, and GIC. And it is found that the application of desensitizers on dentin surface does not affect the shear bond strength. Conclusion: Dentin desensitizers that alleviate or prevent a dentin tenderness, usually contains HEMA and glutaraldehyde compounds. Such desensitizers are widely used in clinical studies. By applying the dentin desensitizer on the exposed dentin surface, the dentin capillary are blocked and periodontal membrane and cementum can not be drawn in pulp cavity. Since HEMA and glutaraldehyde may cause harm to the pulp cavity, an alternative desensitizer was developed.

INFLUENCE OF THE EVAPORATOIN OF LIQUIDS OF DENTAL CEMENTS ON THE PROPERTIES OF HARDENED CEMENTS (치과용 시멘트 용액의 증발이 경화된 시멘트의 성질에 미치는 영향)

  • Kim, Hyang-Kyung;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.156-169
    • /
    • 1997
  • This study was designed to evaluate the influences of evaporation of liquid of dental cements by drying during long term using. Zinc phosphate cement, polycarboxylate cement, and glass ionomer cement were used, and evaluated the properties as follows; consistency, setting time, film thickness, solubility, and compressive strength according to the ADA specification. The specimens of control group were made by mixing the newly opened liquid using the powder-liquid ratio recommended by the manufacturer, and the specimens of ES groups were made by mixing the 10% evaporated liquid by drying with the powder-liquid ratio recommeded by the manufacturer, and the specimens of EM group were made by mixing the 10% evaporated liquid with the powder-liquid ratio modified for standard consistency. The following conclusions were drawn ; 1. The viscosity of mixture of all kinds of cements were increased by the evaporation of liquid, especially the viscosity of glass ionomer cement were influenced significantly. 2. The amount of liquid should be increased to get a standard consistency at the using of evaporated liquid of cement, the most significant increase of liquid amount was required on Ketac-Cem. 3. The setting times were increased at both cases of mixing of evaporated liquid with powder - liquid ratio recommended by manufacturer or modifided through consistency test. 4. At an experimental group of mixing of the evaporated liquid with powder-liquid ratio recommended by manufacturer, solubility was decreased and film thickness was increased. 5. By the result of evaporation of cement liquid, the compressive strength of polycarboxylate cement was increased slightly and it of glass ionomer cement was increased, however, by the increase of amount of liquid to be possible to manipulate the compressive strength were decreased.

  • PDF

A STUDY ON THE COMPLETE RETRIEVAL SYSTEM OF THE CEMENTATION TYPE IMPLANT ABUTMENT (손상 없이 영구 접착 보철물을 제거할 수 있는 cementation type 임플랜트 지대주 개발에 관한 연구)

  • Choi Jin-Ho;Lee Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.597-607
    • /
    • 2004
  • Purpose: This study was peformed to investigate the retrievability of the cemented crown from the cementation type implant abutment. Material and method: The cementation type implant abutments (NEOBIOTECH implant abutment regular, 3 degree taper, 10mm length, 4mm diameter, Ti grade III, machined surface. Hwasung, Kyunggi-do) and cemented crowns were divided into 3 groups, depending on their hole angles formed in the crowns for their retrievability. The abutments and crowns were luted with 4 kinds of cements and separation test using metal wedge was executed with Instron 4465 Universal Testing Machine and the maximum impact force of the modified crown ejector was measured. Results and conclusion : 1. All of the cementation type implant abutments and cemented crowns were separated with relatively small force by metal wedge. 2. The retrieving force was minimum when the metal wedge was applied perpendicular to the axis of abutment. 3. The force for retrieving crowns from abutments was maximum in resin cement group, and reduced in orders of zinc phosphate cement, glass ionomer cement and zinc oxide eugenol cement. 4. The maximum force obtained by the crown ejector was higher than the retrieval force in ZOE and GI cement and lower than that in ZPC and resin cement. 5. If it has similar conditions clinically, the cemented crowns luted with 2 types of cements (ZOE, GI cement) can be safely retrieved from the cementation type implant abutments by the modified crown ejector.

Effect of abutment neck taper and cement types on the amount of remnant cement in cement-retained implant restorations: an in vitro study

  • Park, Yeon-Hee;Kim, Kyoung-A;Lee, Jung-jin;Kwon, Tae-min;Seo, Jae-Min
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.3
    • /
    • pp.162-172
    • /
    • 2022
  • PURPOSE. The present study aims to analyze the effect of abutment neck taper and types of cement on the amount of undetected remnant cement of cement-retained implant prostheses. MATERIALS AND METHODS. Three neck taper angles (53°, 65°, 77°) and three types of cement (RMGI: resin-modified glass ionomer, ZPC: zinc phosphate cement, ZOE: zinc oxide eugenol cement) were used. For each group, the surface percentage was measured using digital image and graphic editing software. The weight of before and after removing remnant cement from the abutment-crown assembly was measured using an electronic scale. Two-way ANOVA and Duncan & Scheffe's test were used to compare the calculated surface percentage and weight of remnant cement (α = .05). RESULTS. There were significant differences in remnant cement surface percentage and weight according to neck taper angles (P < .05). However, there were no significant differences in remnant cement surface percentage and weight on types of cement. No interaction was found between neck taper angles and types of luting cement (P > .05). The wide abutment with a small neck taper angle showed the most significant amount of remnant cement. And the types of luting cement did not influence the amount of residual cement. CONCLUSION. To remove excess cement better, the emergence profile of the crown should be straight to the neck taper of the abutment in cement-retained implant restoration.

AN EXPERIMENTAL STUDY ON THE FILM THICKNESS OF RESIN LUTING CEMENTS (치과용 레진 시멘트의 피막도에 관한 실험적 연구)

  • Cho Kook-Hyeon;Song Chang-Yong;Song Kwang-Yeob;Park Chan-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.2
    • /
    • pp.212-224
    • /
    • 1994
  • The purpose of this study was to evaluate and compare film thickness of five kinds of resin luting cements [Comspan, Panavia Ex, Maryland bridge adhesive, All-bond C & B cementation kit, and Super-bond C & B]. Zinc-phosphate cement and glass-ionomer cement were used as the control group. In order to measure the film thickness the methods used were in broad compliance with ADA Specification No. 8, a tapered-die system that simulates clinical conditions more closely, and the connected tapered-die system that simulates bridge conditions. The inorganic filler size of resin cements was also examined with scanning electron micrographs. The results were obtained as follows ; 1. The film thickness of resin cements was increased in the order of Comspan, Panavia Ex, Super-bond C & B, Maryland bridge adhesive, and All-bond C & B cementation kit. Maryland bridge adhesive and All-bond C & B cementation kit showed significantly higher film thickness than the control group(p<0.01). 2. For all resin cements, there was a significant difference of film thickness between the ADA method and the tapered-die system. Generally, the tapered-die system demonstrated lower film thickness than the ADA method(p<0.01). 3. There was no significant difference in film thickness between the tapered-die system and the tapered-die bridge system in all resin cements(p<0.01). 4. The scanning electron microscope showed that the cement with larger filler had a tendency to be higher in film thickness.

  • PDF

Fabrication and Sensing Capability of Cholesterol Sensors Based on ZnO Nanofibers (산화아연 나노섬유 기반 콜레스테롤 센서의 제작과 성능)

  • Jo, So Yeon;Kim, Ji Yeong;Kim, Sang Sub
    • Korean Journal of Materials Research
    • /
    • v.23 no.5
    • /
    • pp.281-285
    • /
    • 2013
  • In the present work, ZnO nanofibers were applied to electrode materials for the detection of cholesterol. ZnO nanofibers were synthesized using the electrospinning technique with zinc acetate as a precursor. Electrospinning-synthesized ZnO nanofibers were uniformly distributed by properly controlling the electrospinning parameters. After the calcination treatment, nanofibers of pure ZnO phase were synthesized. Then, these fibers were successfully placed on Au-coated glass substrates by dispersion of ZnO nanofibers in ethanol, dropping, and drying, in sequence. Cholesterol oxidase was then immobilized onto the surface of the ZnO nanofibers. To enhance the immobilization, Nafion was additionally applied. The sensing performances of the fabricated ZnO nanofibers-based sensors were analyzed by cyclic voltammetry in terms of cholesterol concentration ranging from 100 to 400 mg/dl. In the I-V curves, measured by cyclic voltammetry, the ZnO nanofiber-based sensor showed a proportional current behavior with cholesterol concentrations in phosphate buffered saline solution. The sensitivity was measured and found to be $30.7nA/mM{\cdot}cm^2$, which is comparable to the values reported in the literature. After not only optimizing the shape of the ZnO nanofibers but also improving the adhesion nature between the ZnO nanofibers and the Au conducting layer, these fibers can be a good candidate for electrode materials in devices used to detect low concentrations of cholesterol in blood.