DOI QR코드

DOI QR Code

Effect of adhesive luting on the fracture resistance of zirconia compared to that of composite resin and lithium disilicate glass ceramic

  • Lim, Myung-Jin (Department of Conservative Dentistry, School of Dentistry, Chonbuk National University) ;
  • Lee, Kwang-Won (Department of Conservative Dentistry, School of Dentistry, Chonbuk National University)
  • Received : 2016.03.07
  • Accepted : 2016.08.22
  • Published : 2017.02.28

Abstract

Objectives: The purpose of this study was to evaluate the effect of adhesive luting on the fracture resistance of zirconia compared to that of a composite resin and a lithium disilicate glass ceramic. Materials and Methods: The specimens (dimension: $2mm{\times}2mm{\times}25mm$) of the composite resin, lithium disilicate glass ceramic, and yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) were prepared. These were then divided into nine groups: three non-luting groups, three non-adhesive luting groups, and three adhesive luting groups, for each restorative material. In the non-luting groups, specimens were placed on the bovine tooth without any luting agents. In the non-adhesive luting groups, only zinc phosphate cement was used for luting the specimen to the bovine tooth. In the adhesive luting groups, specimens were pretreated, and the adhesive luting procedure was performed using a self-adhesive resin cement. For all the groups, a flexural test was performed using universal testing machine, in which the fracture resistance was measured by recording the force at which the specimen was fractured. Results: The fracture resistance after adhesive luting increased by approximately 29% in the case of the composite resin, 26% in the case of the lithium disilicate glass ceramic, and only 2% in the case of Y-TZP as compared to non-adhesive luting. Conclusions: The fracture resistance of Y-TZP did not increased significantly after adhesive luting as compared to that of the composite resin and the lithium disilicate glass ceramic.

Keywords

References

  1. Piconi C, Maccauro G. Zirconia as a ceramic biomaterial. Biomaterials 1999;20:1-25. https://doi.org/10.1016/S0142-9612(98)00010-6
  2. Swain MV. Limitation of maximum strength of zirconiatoughened ceramics by transformation toughening increment. J Am Ceram Soc 1985;68:C97-C99.
  3. Chevalier J, Olagnon C, Fantozzi G, Gales B. Crack propagation behavior of Y-TZP ceramics. J Am Ceram Soc 1995;78:1889-1894. https://doi.org/10.1111/j.1151-2916.1995.tb08905.x
  4. Guazzato M, Albakry M, Ringer SP, Swain MV. Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part II. Zirconia-based dental ceramics. Dent Mater 2004;20:449-456. https://doi.org/10.1016/j.dental.2003.05.002
  5. Memarpour M, Mesbahi M, Rezvani G, Rahimi M. Microleakage of adhesive and nonadhesive luting cements for stainless steel crowns. Pediatr Dent 2011;33:501-504.
  6. Hill EE. Dental cements for definitive luting: a review and practical clinical considerations. Dent Clin North Am 2007;51:643-658. https://doi.org/10.1016/j.cden.2007.04.002
  7. de la Macorra JC, Pradies G. Conventional and adhesive luting cements. Clin Oral Investig 2002;6:198-204. https://doi.org/10.1007/s00784-002-0184-1
  8. Manhart J, Scheibenbogen-Fuchsbrunner A, Chen HY, Hickel R. A 2-year clinical study of composite and ceramic inlays. Clin Oral Investig 2000;4:192-198. https://doi.org/10.1007/s007840000086
  9. Peumans M, Van Meerbeek B, Lambrechts P, Vanherle G. Porcelain veneers: a review of the literature. J Dent 2000;28:163-177. https://doi.org/10.1016/S0300-5712(99)00066-4
  10. Platt JA. Resin cements: into the 21st century. Compend Contin Educ Dent 1999;20:1173-1182.
  11. Mak YF, Lai SC, Cheung GS, Chan AW, Tay FR, Pashley DH. Micro-tensile bond testing of resin cements to dentin and an indirect resin composite. Dent Mater 2002;18:609-621. https://doi.org/10.1016/S0109-5641(02)00005-2
  12. Scherrer SS, de Rijk WG, Belser UC, Meyer JM. Effect of cement film thickness on the fracture resistance of a machinable glass-ceramic. Dent Mater 1994;10:172-177. https://doi.org/10.1016/0109-5641(94)90028-0
  13. Burke FJ, Wilson NH, Watts DC. Fracture resistance of teeth restored with indirect composite resins: the effect of alternative luting procedures. Quintessence Int 1994;25:269-275.
  14. Burke FJ. The effect of variations in bonding procedure on fracture resistance of dentin-bonded all-ceramic crowns. Quintessence Int 1995;26:293-300.
  15. Derand P, Derand T. Bond strength of luting cements to zirconium oxide ceramics. Int J Prosthodont 2000;13:131-135.
  16. Wegner SM, Kern M. Long-term resin bond strength to zirconia ceramic. J Adhes Dent 2000;2:139-147.
  17. Valandro LF, Ozcan M, Amaral R, Leite FP, Bottino MA. Microtensile bond strength of a resin cement to silicacoated and silanized In-Ceram Zirconia before and after aging. Int J Prosthodont 2007;20:70-72.
  18. Chen L, Suh BI, Kim J, Tay FR. Evaluation of silicacoating techniques for zirconia bonding. Am J Dent 2011;24:79-84.
  19. Atsu SS, Kilicarslan MA, Kucukesmen HC, Aka PS. Effect of zirconium-oxide ceramic surface treatments on the bond strength to adhesive resin. J Prosthet Dent 2006;95:430-436. https://doi.org/10.1016/j.prosdent.2006.03.016
  20. Ozcan M, Alkumru HN, Gemalmaz D. The effect of surface treatment on the shear bond strength of luting cement to a glass-infiltrated alumina ceramic. Int J Prosthodont 2001;14:335-339.
  21. Ozcan M, Vallittu PK. Effect of surface conditioning methods on the bond strength of luting cement to ceramics. Dent Mater 2003;19:725-731. https://doi.org/10.1016/S0109-5641(03)00019-8
  22. Tanaka R, Fujishima A, Shibata Y, Manabe A, Miyazaki T. Cooperation of phosphate monomer and silica modification on zirconia. J Dent Res 2008;87:666-670. https://doi.org/10.1177/154405910808700705
  23. Ruttermann S, Fries L, Raab WH, Janda R. The effect of different bonding techniques on ceramic/resin shear bond strength. J Adhes Dent 2008;10:197-203.
  24. Piwowarczyk A, Lauer HC, Sorensen JA. The shear bond strength between luting cements and zirconia ceramics after two pre-treatments. Oper Dent 2005;30:382-388.
  25. Furukawa K, Inai N, Tagami J. The effects of luting resin bond to dentin on the strength of dentin supported by indirect resin composite. Dent Mater 2002;18:136-142. https://doi.org/10.1016/S0109-5641(01)00032-X
  26. Swain MV, Garvie RC, Hannink RHJ. Influence of thermal decomposition on the mechanical properties of magnesia-stabilized cubic zirconia. J Am Ceram Soc 1983;66:358-362. https://doi.org/10.1111/j.1151-2916.1983.tb10049.x
  27. Masaki T. Mechanical properties of toughened $ZrO_{2}-Y_{2}O_{3}$ ceramics. J Am Ceram Soc 1986;69:638-640. https://doi.org/10.1111/j.1151-2916.1986.tb04823.x
  28. Lehmann F, Kern M. Durability of resin bonding to zirconia ceramic using different primers. J Adhes Dent 2009;11:479-483.
  29. Kitayama S, Nikaido T, Takahashi R, Zhu L, Ikeda M, Foxton RM, Sadr A, Tagami, J. Effect of primer treatment on bonding of resin cements to zirconia ceramic. Dent Mater 2010;26:426-432. https://doi.org/10.1016/j.dental.2009.11.159
  30. Ozcan M, Nijhuis H, Valandro LF. Effect of various surface conditioning methods on the adhesion of dualcure resin cement with MDP functional monomer to zirconia after thermal aging. Dent Mater J 2008;27:99-104. https://doi.org/10.4012/dmj.27.99
  31. Kern M, Barloi A, Yang B. Surface conditioning influences zirconia ceramic bonding. J Dent Res 2009;88:817-822. https://doi.org/10.1177/0022034509340881
  32. Kern M, Wegner SM. Bonding to zirconia ceramic: adhesion methods and their durability. Dent Mater 1998;14:64-71. https://doi.org/10.1016/S0109-5641(98)00011-6
  33. Yoshida K, Tsuo Y, Atsuta M. Bonding of dual-cured resin cement to zirconia ceramic using phosphate acid ester monomer and zirconate coupler. J Biomed Mater Res B Appl Biomater 2006;77:28-33.
  34. Ernst CP, Cohnen U, Stender E, Willershausen B. In vitro retentive strength of zirconium oxide ceramic crowns using different luting agents. J Prosthet Dent 2005;93:551-558. https://doi.org/10.1016/j.prosdent.2005.04.011
  35. Kumbuloglu O, Lassila LV, User A, Vallittu PK. Bonding of resin composite luting cements to zirconium oxide by two air-particle abrasion methods. Oper Dent 2006;31:248-255. https://doi.org/10.2341/05-22

Cited by

  1. Establishment of optimal variable elastic modulus distribution in the design of full-crown restorations by finite element analysis vol.40, pp.6, 2017, https://doi.org/10.4012/dmj.2021-053