• Title/Summary/Keyword: Zero-vector

Search Result 301, Processing Time 0.023 seconds

Model Predictive Control of Circulating Current Suppression in Parallel-Connected Inverter-fed Motor Drive Systems

  • Kang, Shin-Won;Soh, Jae-Hwan;Kim, Rae-Young
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1241-1250
    • /
    • 2018
  • Parallel three-phase voltage source inverters in a direct connection configuration are widely used to increase system power ratings. A zero-sequence circulating current can be generated according to the switching method; however, the zero-sequence circulating current not only distorts current, but also reduces the system reliability and efficiency. In this paper, a model predictive control scheme is proposed for parallel inverters to drive an interior permanent magnet synchronous motor with zero-sequence circulating current suppression. The voltage vector of the parallel inverters is derived to predict and control the torque and stator flux components. In addition, the zero-sequence circulating current is suppressed by designing the cost function without an additional current sensor and high-impedance inductor. Simulation and experimental results are presented to verify the proposed control scheme.

Research on a Multi-level Space Vector Modulation Strategy in Non-orthogonal Three-dimensional Coordinate Systems

  • Zhang, Chuan-Jin;Wei, Rui-Peng;Tang, Yi;Wang, Ke
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1160-1172
    • /
    • 2017
  • A novel space vector modulation strategy in the non-orthogonal three-dimensional coordinate system for multi-level three-phase four-wire inverters is proposed in this paper. This new non-orthogonal three-dimensional space vector modulation converts original trigonometric functions in the orthogonal three-dimensional space coordinate into simple algebraic operations, which greatly reduces the algorithm complexity of three-dimensional space vector modulation and preserves the independent control of the zero-sequence component. Experimental results have verified the correctness and effectiveness of the proposed three-dimensional space vector modulation in the new non-orthogonal three-dimensional coordinate system.

Instantaneous Power Compensation Theory in Three-phase Four-wire Systems (3상 4선 계통에서의 순시전력 보상이론)

  • Kim, Hyo-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.172-183
    • /
    • 2006
  • This paper analyzes instantaneous power compensation theory through comparing p-q theory and cross-vector theory which were proposed by Akagi and Nabae respectively in three-phase four-wire systems. The two compensation theories are identical when there is no zero-sequence voltage component in three-phase three-wire systems, However, when the zero-sequence voltage and/or current components exist in three-phase four-wire systems, the two compensation theories we different in definition on instantaneous real power and instantaneous imaginary power. Based on the analysis, this paper presents instantaneous power compensation method that can eliminate neutral current completely without using energy storage element when the zero-sequence current and voltage components exist in three-phase four-wire systems.

A Novel Single Phase Synchronous Reference Frame Phase-Locked Loop with a Constant Zero Orthogonal Component

  • Li, Ming;Wang, Yue;Fang, Xiong;Gao, Yuan;Wang, Zhaoan
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1334-1344
    • /
    • 2014
  • A novel single phase Phase-Locked Loop (PLL) is proposed in this paper to accurately and rapidly estimate the instantaneous phase angle of a grid. A conjugate rotating vector pair is proposed and defined to synthesize the single phase signal in the stationary reference frame. With this concept, the proposed PLL innovatively sets one phase input of the PARK transformation to a constant zero. By means of a proper cancellation, a zero steady state phase angle estimation error can be achieved, even under magnitude and frequency variations. The proposed PLL structure is presented together with guidelines for parameters adjustment. The performance of the proposed PLL is verified by comprehensive experiments. Satisfactory phase angle estimation can be achieved within one input signal cycle, and the estimation error can be totally eliminated in four input cycles for the most severe conditions.

Transformerless DGS Control using a Z-source Boost Inverter (Z-원 승압인버터를 이용한 변압기 없는 DGS제어)

  • Park Young-San
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.9
    • /
    • pp.1617-1624
    • /
    • 2006
  • This paper presents system modeling, modified space vector PWM implementation and design of a closed loop controller of the Z-source inverter which consists of L and C components and shoot-through zero vectors for DGS. Zero vector periods of SVPWM utilized to boost DC-link voltage instead of conventional DC/DC converter and transformer. Only two shoot-through vut(nn are used for DC link voltage control during one switching period without loss of non-zero vectors. Discrete time sliding mode controller, robust servomechanism controller are designed to realize fast and no-overshoot current response and a steady state voltage error. Simulation results are shows the effectiveness of the proposed algorithm.

A New Active Zero State PWM Algorithm for Reducing the Number of Switchings

  • Yun, Sang-Won;Baik, Jae-Hyuk;Kim, Dong-Sik;Yoo, Ji-Yoon
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.88-95
    • /
    • 2017
  • To reduce common-mode voltage (CMV), various reduced CMV pulse width modulation (RCMV-PWM) algorithms have been proposed, including active zero state PWM (AZSPWM) algorithms, remote state PWM (RSPWM) algorithms, and near state PWM (NSPWM) algorithms. Among these algorithms, AZSPWM algorithms can reduce CMV, but they increase the number of switchings compared to the conventional space vector PWM (CSVPWM). This paper presents a new AZSPWM algorithm for reductions in both the CMV and total number of switchings in BLAC motor drives. Since the proposed AZSPWM algorithm uses only active voltage vectors for motor control, it reduces CMV by 1/3 compared to CSVPWM. The proposed AZSPWM algorithm also reduces the total number of switchings compared to existing AZSPWM algorithms by eliminating the switchings required from one sector to the next. The performance of the proposed algorithm is verified by analyses, simulations, and experimental results.

Induction Motor Position Controller Based on Rotational Motion Equations

  • Salem, Mahmoud M.
    • Journal of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.268-274
    • /
    • 2008
  • This paper presents a proposed position controller for a vector controlled induction motor. The position controller design depends on the rotational motion equations and a classical speed controller (CSC) performance. The CSC is designed to have the ability to track variable reference inputs and to provide a predefined system performance. Standard position controller in industry is presented to analyze its performance and its drawbacks. Then the proposed position controller is designed, based on the well defined rotational motion equations. The proposed position controller and the CSC are applied to control the position and speed of the vector controlled induction motor with different ratings. Simulation results at different operating conditions are presented to evaluate the proposed controllers' performance. The results show that the CSC can drive the motor with a predefined speed performance and can track a variable reference speed with an approximately zero steady state error. The results also show that the proposed position controller has the ability to effect high-precision positioning in a limited time and to track a variable reference position with a zero steady state error.

Optimal Zero Vector Selecting Method to Reduce Switching Loss on Model Predictive Control of VSI (전압원 인버터의 모델 예측 제어에서 스위칭 손실을 줄이기 위한 최적의 제로 벡터 선택 방법)

  • Park, Jun-Cheol;Kwak, Sangshin
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.23-24
    • /
    • 2014
  • 본 논문은 전압원 인버터를 모델 예측 제어 (Model Predictive Control)를 하는데 있어 스위칭 손실을 줄이기 위한 제로 벡터 (zero-vector) 선택 방법을 제안한다. 기존의 전압원 인버터의 모델 예측 제어는 제로 벡터의 중복을 선택하는 방법이 제시되지 않아, 이에 대한 연구가 필요하다. 본 논문에서는 제로 벡터의 중복을 선택하는 방법으로 스위칭 손실을 줄이기 위한 제로 시퀀스 전압을 생성하고, 생성된 제로 시퀀스 전압의 부호를 통해 제로 벡터의 중복을 선택하였다. 따라서 전류의 품질은 그대로 유지시키는 동시에 스위칭 손실을 감소시킬 수 있다. 이를 시뮬레이션으로 검증하였다.

  • PDF

The Effect of Dislocation Pipe Diffusion on Electro-Migration-Induced Breakdown in an FCC Structure (면심입방구조에서 Electro-Migration-Induced Breakdown에 대한 전위파이프 확산의 영향)

  • 이득용
    • Journal of the Korean Ceramic Society
    • /
    • v.28 no.11
    • /
    • pp.878-884
    • /
    • 1991
  • The mobility and diffusivity in an edge dislocation in an FCC crystal formed by the removal of one half of a (100) plane were evaluated in an applied field by analyzing a vacancy tight binding model using Stark's matrix technique. A model of an edge dislocation in an FCC crystal was constructed for a [100] Burgers vector where vacancy transport along the edge dislocation in an FCC crystal was constructed for a [100] Burgers vector where vacancy transport along the edge of the extrac half plane of ions was considered. The model considered a tight binding approximation of the vacancy to the compressed region of the core and carried the calculation to the limit of an infinite length of dislocation. The diffusivity and the ratio of mobility to diffusivity were found to increase without bounds in the limit where the correlation factor becomes zero. In contrast, as the correlation factor became unity, the diffusivity became zero and the ratio of mobility to diffusivity became unity associated with the uncorrelated limit of 1/kT. This implied that the phenomenon was not unique to the crystal structure but was unique to edge dislocations with vacancy tight binding.

  • PDF

Power Spectrum of 2 Phase Random Centered Distribution Modulation Scheme with Multi Zero Vector (멀티 영벡터를 갖는 2상 랜덤 중앙 분포 변조기법의 파워 스펙트럼)

  • Oh S. Y.;Kim J. G.;Lim Y. C.;Yang H. Y.;Jung Y. G.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.21-30
    • /
    • 2003
  • 본 연구에서는 변조지수 M이 큰 영역에서는 고조파 스펙트럼의 광대역화 효과가 저하되는 2상 랜덤 중앙 정렬 변조기법 (Random Centered Distribution PWM : RCD)기법의 문제점을 해결하고자 멀티 영벡터 2상 RCD (Multi Zero Vector RCD : MZRCD) 변조기법을 제안하였다. 제안된 2상 MZRCD기법은 변조지수 M=0.7을 기준으로 하여 M이 0.7보다 큰 영역에서는 영벡터를 V(111)로 선택하고, 0.7보다 작은 영역에서는 V(000)을 선택한다. 제안된 방법을 유도모터 구동시스템에 적용해 본 결과, M이 0.7이상인 영역에서도 모터의 전압/전류 및 소음 스펙트럼의 광대역화 특성이 종전의 방법에 비하여 우수함을 확인할 수 있었다.

  • PDF