• 제목/요약/키워드: Zero-Valent Metals

검색결과 20건 처리시간 0.027초

Degradation of Chlorinated Organic Compounds by Zero Valent Metals and an Electron carrier

  • Kim, Young-Hun
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 총회 및 춘계학술발표회
    • /
    • pp.53-56
    • /
    • 2001
  • The degradation of tetrachloroethene (PCE) and trichloroethene (TCE) by vitamin B$_{12}$, an electron mediator was examined when zero valent metals (ZVMs) were used as built electron donors. Dechlorination of PCE and TCE by iron and zinc in the presence of vitamin B$_{12}$ showed that the zinc and vitamin B$_{12}$ combination greatly enhances the reaction rates for both PCE and TCE, but iron and vitamin B$_{12}$ result in an increase in reactivity only for PCE degradation, not for TCE degradation in comparing with meta]s only. This result indicates vitamin B$_{12}$(I) Is active towards both PCE and TCE degradation while vitamin B$_{12}$(II) is active towards both PCE. Calculated activation energies for the dechlorination of PCE in the presence of Vitamin B$_{12}$ showed that vitamin B$_{12}$ lowered the activation energy about 40-60 kJ/㏖ for the both metals.the both metals.

  • PDF

영가금속 및 촉매를 이용한 방향족 유기오염물의 환원

  • 김영훈;도혜현;신원식;하태욱;최상준
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.176-179
    • /
    • 2003
  • The objective of this study was to investigate reductive dechlorination of aromatic hydrocarbons using zero valent metals (ZVMs) and catalysts as reactive materials for permeable reactive barriers (PRBs). A group of small aromatic hydrocarbons such as monochlorophenols, phenol, benzene were readily reduced with palladium catalyst and zero valent iron. Poly-aromatic hydrocarbons (PAHs) were also tested with the catalysts and zero valent metal combinations. The aromatic rings were reduced and partly reduced PAHs were found as the daughter compounds. Current preliminary study implicate that ZVMs and modified catalysts can be successfully applied for PRBs which currently applicable for halogenated organic compounds and some inorganic contaminants including chromium(Ⅵ) and nitrate.

  • PDF

영가금속에 의한 Endosulfan I과 II의 환원분해에 미치는 계면활성제의 영향 (Effect of surfactants on reductive degradation of Endosurfan I and II by ZVM)

  • 김진영;김영훈;신원식;전영웅;송동익;최상준
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 추계학술발표회
    • /
    • pp.187-190
    • /
    • 2002
  • Reductive dechlorination of endosulfans was studied with zero valent metals (ZVMs) and bimetals in aqueous batch reactors. The effect of surfactants was evaluated. Endosulfan was successfully dechlorinated with zero valent iron. However, a bimetal, palladium coated iron (Pd/Fe) showed a highly enhanced reactivity for both endosulfan I and II indicating palladium act as a dechlorination catalyst on the iron. The effect of surfactants on degradation with ZVM has been very controvertible. Variable concentration of a nonionic surfactant, Triton X-100 and an anionic surfactant, SDS were added into the reactor with ZVM. The reaction rates of endosulfan were increased with both surfactants. In the case of Triton X-100, the reaction rate was increased with the increasing surfactant concentration up to 400 mg/L. Addition of small amount of surfactant under the CMC, the reaction rate was increased. However, the enhancing effect was diminished when a higher concentration of surfactant (1,000 mg/L) was used. Current study implicate that the surfactant adsorbed on the metal surface might increase the surface concentration of endosulfan resulting in the increased reaction rate. However, partitioning of endosulfan into the micelle formed at the high concentration of surfactant diminish the enhancing effect by reducing the contact chance between target compound and the metal surface.

  • PDF

Adaptive method for the purification of zinc and arsenic ions contaminated groundwater using in-situ permeable reactive barrier mixture

  • Njaramba, Lewis Kamande;Nzioka, Antony Mutua;Kim, Young-Ju
    • International Journal of Advanced Culture Technology
    • /
    • 제8권2호
    • /
    • pp.283-288
    • /
    • 2020
  • This study investigated the purification process of groundwater contaminated with zinc and arsenic using a permeable reactive barrier with a zero-valent iron/pumice mixture. We determined the removal rates of the contaminants for 30 days. In this study, column reactor filled with the zero-valent iron/pumice reactive mixture was used. Experimental results showed that the mixture exhibited an almost complete removal of the zinc and arsenic ions. Arsenic was removed via co-precipitation and adsorption processes while zinc ions were asorbed in active sites.The purification process of water from the metal ionscontinued for 30 days with constant hydraulic conductivity because of the enhanced porosity of the pumice and interparticle distance between the zero-valent iron and pumice. Contaminants removal rates and the remediation mechanism for each reactive system are described in this paper.

영가금속을 이용한 불포화대에서 유기물질의 환원적 분해 (Reduction of Organics in an Unsaturated Zone Using Zero-Valent Metals)

  • 김종건;권희원;김정진;황인성;김영훈
    • 한국환경과학회지
    • /
    • 제31권1호
    • /
    • pp.77-85
    • /
    • 2022
  • Environmental contamination by organic compounds are not only restricted to water, but extends to soil and groundwater as well. However, highly oxidized compounds, such as halogenated organics and nitro-compounds, can be detoxified employing reducing methods. Permeable reactive barrier is one of the representative technologies where zero-valent metals (ZVMs) are employed for groundwater remediation. However, organics contaminates often contaminate the unsaturated zone above the groundwater. Despite the availability of technologies like soil vapor extraction and bioremediation, removing organic compounds from this zone represents several challenges. In this study, the reduction of nitrobenzene to aniline was achieved using zero-valent iron (ZVI) under unsaturated conditions. Results indicated that the water content was an important variable in this reaction. Under dry conditions (water content = 0.2%), the reduction reaction was inhibited; however, when the water content was between 10% and 25% (saturated condition), ZVI can reduce nitrobenzene. Palladized iron (Pd/Fe) can be used to reduce nitrobenzene when the water content is between 2.5% and 10%. The reaction was evaluated over a wide range of temperatures (10 - 40 ℃), and the results indicated that increasing the temperature resulted in increased reaction rates under unsaturated conditions.

침투성 반응벽체를 위한 고활성 영가금속 개발 (Development of Activity Enhanced Zero Valent Metals for Permeable Reactive Barrier)

  • Kim, Young-Hun;Kim, Myung-Chul
    • 한국환경과학회지
    • /
    • 제12권2호
    • /
    • pp.201-205
    • /
    • 2003
  • The dechlorination of chlorinated methanes by iron powder and palladium coated iron (Pd/Fe) was studied in batch experiments. Iron powder dechlorinated carbon tetrachloride (CT) with a half-life of 4 days. Three chloromethane was found as major product and less chlorinated daughters. Mass balance found was to be about 93-99%. Pd/Fe showed very enhanced reactivity for CT in comparing with plain iron. The major dechlorination products of CT were also less chlorinated methanes with Pd/Fe. Pd/Fe also degrade the produced less chlorinated compounds. Sequential reactions were occurred on Pd/Fe. As the Pd/Fe content increased, the reaction rate was increased linearly.

0가 철과 직류전원을 이용한 TCE 오염 지하수의 정화기법 예비조사 (Preliminary Experiments for the Remediation of Trichloroethene-Contaminated Groundwater Using Direct-Current and Zero-Valent Iron)

  • 문지원;문희수;노열;이석영;송윤구
    • 자원환경지질
    • /
    • 제34권3호
    • /
    • pp.307-313
    • /
    • 2001
  • $Fe^0$ 등의 0가 금속을 포함하는 반응재들은 오염운이 반응벽을 통과하는 동안 염소계 용매들을 분해시킨다. Fe$^{0}$ 를 이용한 투수성 반응벽은 특히 trichloroethene(TCE)이 주된 오염원인 경우 처리비용이 적다는 장점이 있는 반면, 반응속도가 느리고, 반응벽의 운영기간이 제한된다는 단점이 있다. 본 연구는 기존의 Fe$^{0}$ 를 이용한 반응벽에 직류전원을 걸어주는 향상된 처리기술 개발은 예비연구이다. $Fe^0$ 반응컬럼을 이용한 bench-scale의 실험을 통해 $Fe^0$ 반응재와 직류전원의 조합은 TCE의 탈염소화를 촉진하는 것으로 나타났다. 탈염소화의 반응기작은 철의 산화와 부가적인 전자의 공급원인 외부전원에 의한 환원에 기인한다.

  • PDF

TCE제거를 위한 반응층과 고정화층의 결합 실험

  • 조현희;박재우
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 추계학술발표회
    • /
    • pp.67-70
    • /
    • 2002
  • Remediation of groundwater contaminated with chlorinated organics, nitro aromatics, and heavy metals using zero valent iron (ZVI) filings has paid considerable attention in recent years. When the contaminants of high concentration leaked abundantly in subsurface environment, permeable reactive barrier technology using iron filing is taken a long time for the remediation of contaminated groundwater, The problem of contaminant shock is able to be solved using surfactant (hexadecyltrimethylammonium, HDTMA) modified bentonite (SMB) as immobilizing material. Therefore, the purpose of this research was to develop the combined remediation technology using conventional permeable reactive and immobilizing barrier for the enhanced decontamination of chlorinated compounds. Four column experiments were conducted to assess the performance of the mixed reactive materials with Ottawa sand, iron filing, and HDTMA-bentonite for trichloroethylene (TCE) removal under controlled groundwater flow conditions. TCE reduction rates with sand/iron filing/HDTMA-bentonite were highest among four column due to dechlorination of TCE by iron filing and sorption of TCE by SMB.

  • PDF

Degradation of Chlorinated Phenols by Zero Valent Iron and Bimetals of Iron: A Review

  • Gunawardana, Buddhika;Singhal, Naresh;Swedlund, Peter
    • Environmental Engineering Research
    • /
    • 제16권4호
    • /
    • pp.187-203
    • /
    • 2011
  • Chlorophenols (CPs) are widely used industrial chemicals that have been identified as being toxic to both humans and the environment. Zero valent iron (ZVI) and iron based bimetallic systems have the potential to efficiently dechlorinate CPs. This paper reviews the research conducted in this area over the past decade, with emphasis on the processes and mechanisms for the removal of CPs, as well as the characterization and role of the iron oxides formed on the ZVI surface. The removal of dissolved CPs in iron-water systems occurs via dechlorination, sorption and co-precipitation. Although ZVI has been commonly used for the dechlorination of CPs, its long term reactivity is limited due to surface passivation over time. However, iron based bimetallic systems are an effective alternative for overcoming this limitation. Bimetallic systems prepared by physically mixing ZVI and the catalyst or through reductive deposition of a catalyst onto ZVI have been shown to display superior performance over unmodified ZVI. Nonetheless, the efficiency and rate of hydrodechlorination of CPs by bimetals depend on the type of metal combinations used, properties of the metals and characteristics of the target CP. The presence and formation of various iron oxides can affect the reactivities of ZVI and bimetals. Oxides, such as green rust and magnetite, facilitate the dechlorination of CPs by ZVI and bimetals, while oxide films, such as hematite, maghemite, lepidocrocite and goethite, passivate the iron surface and hinder the dechlorination reaction. Key environmental parameters, such as solution pH, presence of dissolved oxygen and dissolved co-contaminants, exert significant impacts on the rate and extent of CP dechlorination by ZVI and bimetals.

고농도 PCE 및 1,1,1 TCA 제거를 위한 영가금속 선정 (Screening of Zero-Valent Metal for the Removal of High Concentration PCE and 1,1,1 TCA)

  • 권수열;김영
    • 한국습지학회지
    • /
    • 제12권1호
    • /
    • pp.23-31
    • /
    • 2010
  • 본 연구는 고농도의 PCE 및 1,1,1-TCA가 단독 또는 혼합물로 오염된 지하수 복원을 위해 영가 금속을 이용한 탈염소환원공정을 적용할 때 기술적으로, 경제적으로 가장 적절한 영가금속 선정을 목표로 수행되었다. 고순도 영가철, 고순도 영가아연, 철광석, 고로 슬래그, 차수재용슬래그, 망간 광석 및 아연 광석 등을 대상으로 회분식 반응조 실험을 수행하였으며, PCE, 1,1,1-TCA 및 혼합물의 분해능 및 탈염소화율을 도출하고, 금속 단가 당 변환량을 포함한 경제성 등을 검토하여 최적의 금속광물을 선정하고자 하였다. 연구결과 단일물질 처리시 고순도 영가철과 고순도 영가아연에 의한 제거율 및 분해능이 가장 높게 나타났으며, 그 다음으로 아연광석에 의한 분해능이 양호하였다. 두 물질 제거를 위한 경제성 비교에서는 고순도 영가철과 고순도 영가아연에 비해 아연광석이 매우 양호한 것으로 나타났다. 두 물질의 혼합처리 시에는 단일 처리에 비해 분해능이 감소하는 것으로 나타났다. 이상의 결과로부터 단일 또는 혼합 1,1,1-TCA, PCE 처리를 위한 분해능, 처리특성 및 경제성 등을 고려하였을 때 아연광석이 가장 적절한 금속광물로 사료된다.