• 제목/요약/키워드: Zero region

검색결과 376건 처리시간 0.03초

마이크로 컴퓨터를 이용한 휴대용 부정맥 모니터의 개발(I)-하드웨어 설계를 중심으로- (Development of Portable Arrhythmia Moniter Using Microcomputer(I))

  • 이명호;안재봉
    • 대한의용생체공학회:의공학회지
    • /
    • 제7권2호
    • /
    • pp.169-182
    • /
    • 1986
  • Pulsed ultrasonic Doppler system is a useful diagnostic instrument to measure blood-flow-velocity, velocity profile, and volume-blood-flow. This system is more powerful compare with 2-dimensional B-scan tissue image. A system has been deve- loped and ii being evaluated using TMS 32010 DSP. We use this DSP for the purpose of real-time spectrum analyzer to obtain spectrogram in singlegate pulsed Doppler system and for the serial comb filter to cancel clutter and zero crossing counter to estimate Doppler mean frequency in multigate pulsed Doppler system. The Doppler shift of the backscattered signals is sensed in a phase detector. This Doppler signal corresponds to the mean velocity over a some region in space defined by the ultrasonic beam dimensions, transmitted pulse duration, and transducer ban(iwidth. Multi- gate pulsed Doppler system enable the transcutaneous and simultaneous assessment of the velocities in a number of adjacent sample volumes as a continuous function of time. A multigate pulsed Doppler system processing the information originating from presented.

  • PDF

이분된 지역평균의 차를 이용한 경계점 검출법 (Edge Detection Using Mean Difference within a Connected Bimodal Region)

  • 정문조;심영석;황찬식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(II)
    • /
    • pp.1360-1363
    • /
    • 1987
  • Two edge detection methods are devised and tested. First one makes use of mean-difference between two connected regions after bimodal thresholding within a local window. It appears experimentally to provide reduced edge width maintaining good connectivity. It seems due to the use of the threshold obtained from a larger neighborhood. Second one uses additionally the gradient information to detect approximate zero crossing points of second directional derivative. This provides edges thinned nearly to one pixel width.

  • PDF

콘크리트 충전 강관을 갖는 프리스트레스트 합성형 거더의 강-콘크리트 계면 거동 (Nonlinear Finite Element Analysis of Composite Girder with Concrete Infilled Tube)

  • 신동훈;김영훈;이타;강병수;이용학
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.386-389
    • /
    • 2006
  • Prestressed composite girder bridges with concrete infilled steel tube at negative flexural moment region takes the advantages of enhancing local buckling and flexural resistances resulting from the lateral confining effect of concrete due to the interactive reaction in the interface layer of steel tube and concrete. The interface behavior in concrete infilled tube of the test composite girder is analyzed by 8-node zero thickness interface finite element combined with 3-D. elastoplastic concrete constitutive model and 3-D. elastoplastic Mindlin shell element. The interface effects between infillled concrete and steel tube are investigated through the comparision of the experimental and numerical results.

  • PDF

콘크리트의 극한변형률 수정모델 (Modified model of ultimate concrete compression strain)

  • 고성현;이재훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.81-84
    • /
    • 2008
  • The purposes of this study are to verify a reasonable model of material characteristic and to propose a rational model of reinforcement characteristic considering monotonic and cyclic loading about manufactured reinforcing steel in Korea. Longitudinal reinforcements of the plastic hinge region were behaved tensile deformation and compressional deformation by direction of lateral loading. However Confinement steels were behaved only tensile deformation by lateral loading. Transverse steels were laid the state of tension in the lateral loading of time, and they were laid state that stress is zero when it was removed lateral load. The tests for cyclic tension loading were performed for test variable as yield strength and reinforcement bar sizes. It was estimated that the total strain energy per unit volume was 74 $MJ/m^3$. The modified ultimate concrete compression strain model was proposed based on experimental study of cyclic tension test for manufactured reinforcing steel in Korea.

  • PDF

복소극점을 갖는 선형시불변 단일입출력 시스템의 영점과 계단응답 특성 (Zeros and Step Response Characteristics in LTI SISO Systems with Complex Poles)

  • 이상용
    • 제어로봇시스템학회논문지
    • /
    • 제16권4호
    • /
    • pp.313-318
    • /
    • 2010
  • This paper deals with the relationship between zeros and step response of the second and third order LTI (Linear Time Invariant) SISO (Single-Input and Single-Output) systems with complex poles. Although it has been known that the maximum number of local extrema is less than the number of zeros in the system with only real poles[8], some cases with complex poles are shown in this paper to have many local extrema. This paper proposes monotone nondecreasing conditions and describes the relationship between the transient response and the number of local extrema in step response with each region of zeros.

탄소강 담금질시의 상변태열과 이를 포함한 냉각곡선의 계산 (The Latent Heat of Phase Transformation of the Carbon Steel and the Calculation of Cooling Curves Including the Latent Heat in Quenching)

  • 윤석훈;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권3호
    • /
    • pp.10-16
    • /
    • 1994
  • This study aimed at measuring the latent heat of phase transformation of S45C carbon steel in quenching and at conducting the analytical researches into the calculation of cooling curves including the latent heat. The temperature of phase transformation of steel and its latent heat are dependant upon the cooling rates at the temperature of A1 phase transformation point. The effect of the latent heat of phase transformation is especially manifest at the cooling curve of center of specimens. The higher the cooling rates became, the lower fell the temperature region of phase transformation. In the figures of cooling rates, the phenomena of cooling rate dropping into zero was caused by the latent heat of phase transformation.

  • PDF

터보형 원판형 드래그펌프의 배기특성에 관한 실험적 연구 (An Experimental Study on the Pumping Performance of the Turbo-Type Disk-Type Drag Pump)

  • 황영규;허중식;권명근;이승재
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.577-580
    • /
    • 2002
  • In this paper, the pumping performance of the disk-type drag pump which works in the outlet pressure range from 4 to 0.001 Torr is studied experimentally. The pumping characteristics of various drag pumps are performed. The inlet pressures are measured for various outlet pressures of the test pump. The flow-meter method is adopted to calculate the pumping speed. Compression ratios and pumping speeds for the nitrogen gas are measured. The present experimental data show the leak-limited value of the compression ratio in the molecular transition region. The rotational speed of the pump is 24,000rpm. The inlet pressures are measured for various outlet pressures of the test pump. The ultimate Pressures for zero throughput are measured for three-stage, two-stage and single-stage disk-type, respectively.

  • PDF

고정자 전류 기반의 모델 기준 적응 제어를 애용한 유도전동기의 센서리스 벡터제어 (Sensorless Induction Motor Vector Control Using Stator Current-based MRAC)

  • 박철우;최병태;권우현
    • 제어로봇시스템학회논문지
    • /
    • 제9권9호
    • /
    • pp.692-699
    • /
    • 2003
  • A novel rotor speed estimation method using Model Reference Adaptive Control(MRAC) is proposed to improve the performance of a sensorless vector controller. In the proposed mettled, the stator current is used as the model variable for estimating the speed. In conventional MRAC methods, the relation between the two model errors and the speed estmation error is unclear. Yet, in the proposed method, the stator current error is represented as a function of the first degree for the error value in the speed estimation. Therefore, the proposed method can produce a fast speed estimation and is robust to the parameters error In addition, the proposed method of offers a considerable improvement in the performance of a sensorless vector controller at a low speed. The superiority of the proposed method is verified by simulation and experiment in a low speed region and at a zero-speed.

Effects of solution, sorbate, and sorbent chemistries on polycyclic aromatic hydrocarbon sorption to hydrated mineral surfaces

  • Yim, Soobin
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.132-135
    • /
    • 2003
  • Solution chemistry, sorbate chemistry, and sorbent chemistry were widely investigated to find important factors that affect PAH sorption on mineral surfaces and to elucidate its microscopic mechanism. The solution chemistry, pH and ionic strength caused measurable change of HOC sorption reaction to minerals. The detectable change of Ka occurred at a pH region crossing the PZC (Point of Zero Charge) of each mineral. The PAH hydrophobicity, one of sorbate chemistry, was observed to have a strong correlation with PAM sorption to mineral. Mineral surface area was not found to be a predominant factor controlling PAH sorption. The mineral type might be more likely to play a crucial role in controlling the PAH sorption behavior. The CEC (Cation Exchange Capacity) of mineral, representing surface charge density, has meaningful correlation with regression slope of sorption coefficients (log $K_{d}$) versus aqueous activity coefficients (log Υ$_{w}$).).).

  • PDF

백그라운드 제거후 신호의 세기에 대하여 (ON THE BACKGROUND-SUBTRACTED INTENSITY)

  • 선광일
    • 천문학논총
    • /
    • 제20권1호
    • /
    • pp.109-116
    • /
    • 2005
  • When we measure a source signal in the presence of a background rate that has been independently measured, the usual approach is to obtain an estimate of the background rate by observing an empty part of the sky, and an estimate of the source signal plus background rate by observing the region where a source signal is expected. The source signal rate is then estimated by subtracting the background rate from the source signal plus background rate. However, when the rates or their observation times are small, this procedure can lead to negative estimates of the source signal rate, even when it should produce a positive value. By applying the Bayesian approach, we solve the problem and prove that the most probable value of source signal rate is zero when the observed total count is smaller than the expected background counts. It is also shown that the results from the conventional method is consistent with the most probable value obtained from the Bayesian approach when the source signal is large or the observation time is long enough.