• 제목/요약/키워드: Zero discharge system

검색결과 54건 처리시간 0.026초

무공해 자동차용 수열원 히트펌프 시스템의 난방 성능에 관한 실험적 연구 (An Experimental Study on the Heating Performance of Coolant Heat Source Heat Pump System for Zero Emission Vehicles)

  • 이대웅
    • 한국자동차공학회논문집
    • /
    • 제22권7호
    • /
    • pp.57-62
    • /
    • 2014
  • This study presented the feasibility of a coolant heat-source heat pump system as an alternative heating system for electrically driven vehicles. Heat pumps are among the most environmentally friendly and efficient heating technologies in residential buildings. In various countries, electric mobiles devices such as EV, PHEV, and FCEV, have been mainly concerned with heat pumps for new mobile markets. The experiments herein were conducted for various ambient temperatures and coolant temperatures to reflect the winter season. The system, a coolant heat-source heat pump, consisted of an inside heat exchanger, an outside heat exchanger, a motor driven compressor, an electronic expansion valve, and plumbing parts. For the experimental results, the maximum heating capacity and air discharge temperature are up to 6.3 kW and $62^{\circ}C$ respectively at an ambient temperature of $10^{\circ}C$, and coolant at $10^{\circ}C$. However, at $-20^{\circ}C$ ambient temperature and $-10^{\circ}C$ coolant temperature, conditions were insufficient to warm the cabin as the air discharge temperature was $13^{\circ}C$.

뇌방전 위치표정에 관한 연구(I) (A Study on the lightning Discharge Positioning)

  • 길경석;박대원;김일권;최수연;안창환;이영근
    • 조명전기설비학회논문지
    • /
    • 제21권10호
    • /
    • pp.40-45
    • /
    • 2007
  • 뇌경보시스템은 낙뢰에 의한 인적 물적 피해를 예방하는 중요한 장치이다. 본 논문에서는 뇌경보시스템의 주요기능으로 뇌운의 이동과 활동을 감시할 수 있는 뇌방전 위치표정 알고리즘 및 회로에 대해 연구하였다. 뇌방전시 발생하는 전계성분은 whip 안테나와 공진주파수 300[kHz]의 협대역 공진증폭기로 검출한다. 자계파형 측정회로는 직교루프코일과 적분증폭기로 구성되며 주파수 대역은 5[kHz]$\sim$1.2[MHz]이다. 전계파형으로 뇌방전의 극성을 판별하고, 자계파형의 크기와 영점교차점에 의해 방향과 거리를 산출하여 뇌방전의 위치를 표정한다.

전경 물체 추출 기법을 이용한 전기트리 영상에서 열화 측정 (Degradation Measurement from Electrical Tree Image Using Foreground Object Extracting Skill)

  • 김형균;정기봉;고석만;오무송;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.270-273
    • /
    • 2001
  • Electrical tree is studied widely by manufacture state of insulating material fare and blazing fire diagnosis system of use in phenomenon of part discharge that happen for main cause of dielectric breakdown of equipment for electric power. Use process that draw tree pattern here measuring above zero to study special quality of this electricity tree, real-time processing by image processing is proposed because reproduction of tree blazing fire process drops and pattern of tree is difficult correct quantification of tree growth by existent visual observation by involution. This research presents general process that need in image processing of tree blazing fire, and that remove various noises that happen in above zero by measuring electrical tree dividing background and complete view in measured above zero taking advantage of specially proposed complete view object abstraction techniques effectively and quantification of tree becomes easy naturally, can apply to dielectric breakdown estimate because can chase growth process of tree.

  • PDF

하천 수위-유량곡선식 개선 및 모형개발 (Stage-Discharge Rating Curve Model Development and Modification)

  • 장기환;이재형
    • 한국수자원학회논문집
    • /
    • 제38권4호
    • /
    • pp.271-280
    • /
    • 2005
  • 본 연구의 목적은 기존 수위-유량곡선식에 내재되어 있던 발산과 처리 불능문제를 해결하기 위한 새로운 형태의 관계식($Q=p(h-e)^{\beta}-{\gamma}$)을 제안하고 그러한 수위-유량곡선식 산정모형을 개발하였다. 발산 문제는 영유량 수위 매개변수 e를 찾고 추정된 식의 총오차 값을 최소화하는 동안 승수 매개변수 ${\beta}$가 비정상적으로 커지는 것이다. 불능 문제는 e값이 계측 최소수위 이상의 값일 때 (h - e)값이 음수가 되어 로그값을 취하는 것이 불가능하다는 것이다. 이상의 두 가지 문제는 제어변수 ${\gamma}$를 도입함으로서, ${\beta}$를 감소시키는 효과와 "0" 이상으로 (h - e)를 제어할 수 있게 되었다. 본 연구에서는 물리적 분석과 민감도 분석을 통하여 수위-유량곡선식에서 매개변수 ${\gamma}$의 영향이 e 의 영향과 거의 같음을 보였다. 또한 개발된 WinCARD 시스템은 모든 수위국의 수문분석에 사용되는 기존 수위-유랑곡선식의 적합도를 평가하고, 하천유량 산정을 위한 신규 수위-유량곡선식을 작성하는데 활용될 수 있다.

8kW급 절연형 ESS시스템을 위한 고효율 및 높은 전력밀도를 갖는 LLC 공진형 컨버터 설계 및 실험적 검증 (Design and Experimental Verification of LLC Resonant Converter with High Efficiency and High Power Density for 8kW Isolated ESS System)

  • 김진우;조영훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 추계학술대회
    • /
    • pp.181-182
    • /
    • 2017
  • In the battery system, an isolated converter is used for the stability of the system when controlling the charge and discharge of the battery. A fixed frequency LLC converter which is a type of isolated converter, has the advantage of high efficiency and power density with zero voltage switching at high frequency. Therefore, in this paper, the operation analysis, design and experimental verification of the LLC resonant converter with high efficiency and high power density for the ESS system were conducted.

  • PDF

음식물류폐기물 제로화 주거단지 구축 시나리오별 비용 및 환경효과 분석 (Analysis of Greenhouse Gas Reduction according to Different Scenarios of Zero Food Waste Residential Buildings)

  • 오정익;윤은주;박이레;김영민
    • 대한환경공학회지
    • /
    • 제38권7호
    • /
    • pp.353-363
    • /
    • 2016
  • 본 연구에서는 공동주택 단지에서의 음식물류폐기물을 수거 이송하여 대용량처리시설에 자원화 혹은 재활용하는 기존 방식과 발생지인 공동주택 내에서 처리하는 제안 방식을 가상하여 차량수거방식, 자동집하방식, 자동집하처리방식, 소규모분산처리방식, 오수처리연계방식으로 시나리오를 설정하고 각 시나리오별 초기 투자비용, 석유 사용량, 이산화탄소 배출량, 음식물류폐기물 처리 운영비용, 입주자 부담 관리비를 비교 분석하였다. 기존처리 방식에 비해 제안하는 소규모분산처리방식이 초기 투자비용, 연간 석유사용량, 이산화탄소 배출량이 가장 낮았으며 적용, 도입 가능성이 높았다. 음식물류폐기물 처리 운영비용은 기존 처리방식과 비교하여 1톤당 334,465원(약 91%)이 절감되며 세대 당 월 1,500원인 입주자 부담 관리비용 또한 902원으로 약 40% 절감이 가능하다고 분석되었다. 각 시나리오별 초기 투자비용과 석유사용량, 이산화탄소 배출량을 비교한 결과, 초기 투자비용이 낮은 처리방식이 연료 사용량과 이산화탄소 발생량도 낮은 경향을 나타내었다. 초기 투자비용과 석유사용량, 이산화탄소 배출량이 가장 낮은 시나리오는 소규모분산처리방식이며 가장 높은 시나리오는 오수처리연계방식이었다. 연구의 공간적 범위를 공동주택 단지로 설정할 때 소규모분산처리방식이 음식물류폐기물 제로화 모델로서 가장 적합한 방식으로 판단된다.

한 종합병원의 포괄수가제 실시 전후 수정체수술환자의 의료서비스 및 진료비 비교분석 (The Change of Medical Care Pattern and Cost of Cataract Surgery by the DRG Payment System in a General Hospital)

  • 이미림;이용환;고광욱
    • 한국병원경영학회지
    • /
    • 제10권1호
    • /
    • pp.48-70
    • /
    • 2005
  • The purpose of this study was to make an analysis of the impact of the DRG payment system on medical care pattern and cost of cataract surgery in a general hospital. The subjects were 173 patients whose DRG severity grade was zero, selected from among the hospitalized who underwent cataract surgery before and after the joining to the demonstrational operation of the third year DRG payment system. Their medical records and the details of their medical bills were examined to find out the length of hospital stay, medical care pattern provided to them, the cost of medical care, and the quality of medical care. The length of stay and the amount of medical care supplied during being in hospital dropped significantly for both single-eye and double-eyes cataract surgery groups. The amount of antibiotic use went down during the hospitalization and upon discharge from the hospital, but decreased after discharge. The total medical bills and the rate of basic examination implementation increased in the OPD before hospitalization but after discharge dropped. For double-eyes cataract patients, the rate of double-eyes cataract surgery went down. The total medical bills of DRG payment system converted into the fee-for-service system was greater by 113.3% for the single-eye cataract surgery group and by 102.9% for the doble-eyes cataract surgery group, compared to that by the fee-for-service. The contribution shared by the insurance corporation increased for both single-eye and double-eyes cataract surgery groups, but the copayment by the insured went down. Regarding the treatment outcome, no difference was found in complication rate, resurgery rate and mortality rate before and after the joining to the DRG payment system was implemented. The use of special lens lessened significantly. The amount of medical care supplied during hospitalization decreased but the complication rate didn't increase. But the increased use of low-price artificial cataract and the avoidance of double-eyes cataract surgery was observed. The phenomenon decreased number of OPD visit and the decreased total medical bills of OPD care after discharge in this hospital required further evaluation.

  • PDF

고지재생연구(제 8보) -제지 공정수 폐쇄화에 따른 오여- (Recycling of Wastepaper(Ⅷ)-Contamination of Process WAter by System Closure)

  • 여성국;류정용;신종호;송봉근;오세균
    • 펄프종이기술
    • /
    • 제31권4호
    • /
    • pp.1-7
    • /
    • 1999
  • This study was carried out to simulate the change of various properties of recycled water when zero-discharge system was applied to a KOCC recycling process. contaminants such as chemical oxygen demand, anionic trash, and calcium hardness were gradually increased in the process water as the recycling was repeated . Especially, the increase of anionic trash and COD were closely related to the starch derived from corrugating adhesive in KOCC. Four kinds of water were compared in the preparation of handsheet to evaluate the performance of retention program. Waters used in this work were laboratory tab water, process water from Dong-II mill and the same one treated by UASB process, and closed white water prepared by KRICT. The result revealed that one the major factors fro reducing a retention power was the anioni trash accumulated in the recycled water.

  • PDF

Optimal Characteristics of a Long-pulse $CO_2$Laser by Controlling SCR Firing Angle in AC Power Line

  • Noh, Ki-Kyung;Kim, Geun-Yong;Chung, Hyun-Ju;Min, Byoung-Dae;Song, Keun-Ju;Kim, Hee-Je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제2C권6호
    • /
    • pp.304-308
    • /
    • 2002
  • We demonstrate a simple pulsed $CO_2$ laser with millisecond long pulse duration in a tube at a low pressure of less than 30 Torr. The novel power supply for our laser system switches the voltage of the AC power line (60Hz) directly. The power supply doesn't need elements such as a rectifier bridge, energy-storage capacitors, or a current-limiting resistor in the discharge circuit. To control the laser output power, the pulse repetition rate is adjusted up to 60Hz and the firing angle of SCR(Silicon Controlled Rectifier) gate is varied from 30。 to 150。. A ZCS (Zero Crossing Switch) circuit and a PIC one-chip microprocessor are used to control precisely the gate signal of the SCR. The maximum laser output of 35 W is obtained at a total pressure of 18 Torr, a pulse repetition rate of 60 Hz, and a SCR gate firing angle of 90。 . In addition, the resulting laser pulse width is approximately 3㎳(FWHM). This is a relatively long pulse width, compared with other repetitively pulsed $CO_2$ lasers.

국제 핵융합실험로용 VS(Vertical Stabilization) 컨버터의 운전모드 및 보호동작 (Operation modes and Protection of VS(Vertical Stabilization) Converter for International Thermonuclear Experimental Reactor)

  • 조현식;조종민;오종석;서재학;차한주
    • 전력전자학회논문지
    • /
    • 제20권2호
    • /
    • pp.130-136
    • /
    • 2015
  • This study describes the structure and operation modes of vertical stabilization (VS) converter for international thermonuclear experimental reactor (ITER) and proposes a protection method. ITER VS converter supplies voltage (${\pm}1000V$)/current (${\pm}22.5kA$) to superconducting magnets for plasma current vertical stabilization. A four-quadrant operation must be achieved without zero-current discontinuous section. The operation mode of the VS converter is separated in 12-pulse mode, 6-pulse mode and circulation current mode according to the magnitude of the load current. Protection measures, such as bypass and discharge, are proposed for abnormal conditions, such as over current, over voltage, short circuit, and voltage sag. VS converter output voltage is controlled to satisfy voltage response time within 20 msec. Bypass operation is completed within 60 msec and discharge operation is performed successfully. The feasibility of the proposed control algorithm and protection measure is verified by assembling a real controller and implementing a power system including the VS converter in RTDS for a hardware-in-loop (HIL) facility.