• Title/Summary/Keyword: Z20

Search Result 1,509, Processing Time 0.042 seconds

Early Changes after Death of Plaice, Paralichthys olivaceus Muscle -5. Effect of Storage Temperature on Morphological Changes of Myofibrils and Histological Changes of Muscle- (넙치(Paralichthys olivaceus)육의 사후 조기 변화 -5. 저장 온도가 근원섬유의 형태학적 및 육의 조직학적인 변화에 미치는 영향-)

  • CHO Young-Je;LEE Keun-Woo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.27 no.2
    • /
    • pp.114-120
    • /
    • 1994
  • To clarify the effect of storage temperature on the morphological and histological changes of plaice, Paralichthys olivaceus muscle at early stages after killing, the changes in breaking strength of muscle, morphological observation of myofibrils and histological observation of extracellular spaces during storage at $0^{\circ}C\;and\;10^{\circ}C$ were studied. The maximum breaking strength of samples stored at $0^{\circ}C$ was reached within 10hrs and then it dropped significantly (p<0.05) from 10hrs to 25hrs of storage. However, breaking strength was not increased in fresh muscle stored at $10^{\circ}C$ and gradually decreased after 10hrs storage. In myofibrils prepared from dorsal muscle immediately after death, A-band, I-band, H-band and Z-line in sarcomere were clearly distinguishable from each other. Due to muscle contraction, it was not easy to distinguish H-band from I-band observed in sarcomere stored at $0^{\circ}C$ after 10hrs storage. But, in the case of samples stored at $10^{\circ}C$, H-band could be observed dimly until 15hrs of storage. The changes in morphological myofibrils were closely related to increase of breaking strength. No extracellular space was observed among muscle cells immediately after killing. Stored samples at $0^{\circ}C$ showed extracellular spaces after 15hrs storage. On the other hand, samples stored at $10^{\circ}C$ didn't show any extracellular spaces until 15hrs storage and showed extracellular spaces after 24hrs storage. It was thought that the post-mortem tenderization of plaice muscle was closely related to the gradually disintegration of the extracellular matrix structure after killing.

  • PDF

Studies on the Morphology and Biology of a Parasitic Mite, Pyemotes tritici L.-F. & M. on the Cigarette Beetle(Lasioderma serricorne F.). (Pyemotes tritici L.-F. & M. 궐련벌레살이주머니응애의 형태(形態)와 생활사(生活史)에 관(關)한 연구(硏究))

  • Oh, M.H.;Kim, S.S.;Boo, K.S.
    • Korean journal of applied entomology
    • /
    • v.24 no.1 s.62
    • /
    • pp.15-18
    • /
    • 1985
  • Studies were made on the morphology and life cycle of the mite, Pyemotes tritici $Lagr{\acute{e}}z$-Fossot & $Montagn{\acute{e}}$ (Trombidiformes; Pyemotidea) ,parasitic on larvae of cigarette beetle, Lasioderma serricorne F., which is one of the most serious pests of stored tobacco, cigar, and cigarette in Korea. One generation time was $20.9{\pm}0.7$ days out of which $9.5{\pm}0.3$ days were spent for feeding and $10.3{\pm}0.8$ days for reproduction of progenies. A female of this insect-parasitic mite produced $56.7{\pm}6.9$ progenies during her reproduction period. The body size of a newly-laid male or female was $280{\mu}m$ long and $85{\mu}m$ wide. As female of this mite sucked on, their abdomen grew larger and larger to reach $825{\mu}m$ in width and $0.346mm^3$ in volume after $9{\sim}10$ days. By sucking the humor of a host, the abdomen of a female mite became almost a global shape in two days. The increase rate of abdominal width was the biggest on the second or the third day of feeding while the volume of abdomen reached to the largest on $6{\sim}8$ days after feeding. The largest number of the daily young produced on 4-th day after a female began to reproduce.

  • PDF

EFFECT OF SOFT-START CURING ON THE CONTRACTION STRESS OF COMPOSITE RESIN RESTORATION POLYMERIZED WITH LED AND PLASMA CURING UNIT (LED와 플라즈마 광원의 완속기시 광중합 방식이 복합레진의 수축응력에 미치는 영향)

  • Chung, Yang-Seok;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.4
    • /
    • pp.623-631
    • /
    • 2007
  • Effect of Soft-start curing on the contraction stress of composite resin restoration polymerized with LED and plasma curing unit The purpose of this study was to evaluate the influence of soft-start light curing on contraction stress and hardness of composite resin. Composite resin (Filtek $Z-250^{TM}$, 3M ESPE, USA) was cured using the one-step continuous curing method with three difference light sources ; conventional halogen light ($XL3000^{TM}$, 3M ESPE, USA) cure for 40 seconds at $400 mw/cm^2$, LED light (Elipar Freelight $2^{TM}$, 3M-ESPE, USA) cure for 20 seconds at $800\;mW/cm^2$ a and plasma arc light ($Flipo^{TM}$, LOKKI, France) cure for 12 seconds at $1300 mW/cm^2$. For the soft-start curing method ; LED light (Elipar Freelight $2^{TM}$, 3M-ESPE, USA) cure exponential increase with 5 seconds followed by 17 seconds at $800\;mW/cm^2$ and plasma arc light ($Flipo^{TM}$, LOKKI, France) cure 2 seconds light exposure at $650\;mW/cm^2$ followed by 11 seconds at $1300\;mW/cm^2$. The strain guage method was used for determination of polymerization contraction. Measurements were recorded at each 2 second for the total of 800 seconds including the periods of light application. Obtained data were analyzed statically using Repeated measures ANOVA, One way ANOVA, and Tukey test. The results of present study can be summarized as follows: 1. Composite resin restoration showed transient expansion just after irradiation of curing light. Contraction stress was increased rapidly at the early phase of polymerization and reduced slowly as time elapsed (P<0.05). 2. Contraction stress was not revealed significant difference between Halogen curing light groups and LED and Plasma Light curing with soft-start group (P>0.05). 3. LED and Plasma Light curing with soft-start showed lower contraction stress than the one-step continuous light curing (P<0.05).

  • PDF

Korean Children and Adolescents with Crohn's Disease Are More Likely to Present with Perianal Fistulizing Disease at Diagnosis Compared to Their European Counterparts

  • Kang, Ben;Kim, Jung Eun;Jung, Jae Hun;Choe, Jae Young;Kim, Mi Jin;Choe, Yon Ho;Kim, Seung;Koh, Hong;Lee, Yoo Min;Lee, Jee Hyun;Lee, Yoon;Lee, Ji-Hyuk;Lee, Hae Jeong;Jang, Hyo-Jeong;Choi, Youjin;Choi, So Yoon;Kim, Ju Young;Choe, Byung-Ho
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.23 no.1
    • /
    • pp.49-62
    • /
    • 2020
  • Purpose: We aimed to investigate the disease phenotype of Korean pediatric Crohn's disease (CD) patients at diagnosis according to the Paris classification by comparison with patients from the European multicenter 5-years recruitment of children with newly developed IBD (EUROKIDS registry). Methods: Korean children and adolescents who had been newly diagnosed with CD at the age of <18 years during 2013-2016 were included in this multicenter retrospective study. Disease phenotype at diagnosis was classified according to the Paris classification, and compared with the published data from the EUROKIDS study. Results: A total of 255 patients were included. The median diagnosis age was 14.7 years (range, 0.8-17.9 years). No significant difference was observed in male-to-female ratio with EUROKIDS (1.9:1 vs. 1.45:1, p=0.062). The proportion of children aged <10 years was significantly lower in Koreans (7.1% vs. 19.6%, p<0.001). Colonic disease was less prominent (10.0% vs. 27.3%, p<0.001), while upper GI involvement was more prominent in Korean children (59.3% vs. 46.2%, p<0.001). The proportion with perianal fistulizing disease at diagnosis was significantly higher in Korean patients (44.8% vs. 8.2%, p<0.001). A separate analysis of Korean patients revealed that perianal fistulizing disease at diagnosis was positively associated with male sex and body mass index z-score (odds ratio [OR]=2.12, 95% confidence interval [CI]=1.20-3.76, p=0.010; and OR=1.29, 95% CI=1.05-1.58, p=0.015, respectively). Conclusion: Approximately half of pediatric CD patients in Korea present with perianal fistulas and/or abscesses at diagnosis, which is a distinct feature of CD in Korean children and adolescents compared to their European counterparts. An underlying genetic difference between ethnicities may play a role in this expression of different phenotypes in pediatric CD.

Film Dosimetry for Intensity Modulated Radiation Therapy : Dosimetric Evaluation (필름을 사용한 세기변조치료법에 대한 선량측정)

  • Ju Sang Gyu;Yeo Inhwan Jason;Huh Seung Jae;Choi Byung Ki;Park Young Hwan;Ahn Yong Chan;Kim Dae Yong;Kong Young Kun
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.172-178
    • /
    • 2002
  • Purpose : X-ray film over responds to low-energy photons in relative photon beam dosimetry because its sensor is based on silver bromide crystals, which are high-Z molecules. This over-response becomes a significant problem in clinical photon beam dosimetry particularly in regions outside the penumbra. In intensity modulated radiation therapy (IMRT), the radiation field is characterized by multiple small fields and their outside-penumbra regions. Therefore, in order to use film dosimetry for IMRT, the nature the source of the over-response in its radiation field need to be known. This study is aimed to verify and possibly improve film dosimetry for IMRT. Materials and Method : Modulated beams were constructed by a combination of five or seven different static radiation fields using 6 MeV X-rays. In order to verify film dosimetry, we used X-ray film and an ion chamber were used to measure the dose profiles at various depths in a phantom. In addition, in order to reduce the over-response, 0.01 inch thick lead filters were placed on both sides of the film. Results : The measured dose profiles showed a film over-response at the outside-penumbra and low dose regions. The error increased with depths and approached 15% at a maximum for the field size of $15{\times}15cm^2$ at 10 cm depth. The use of filters reduced the error to 3%, but caused an under-response of the dose in a perpendicular set-up. Conclusion : This study demonstrated that film dosimetry for IMRT involves sources of error due to its over-response to low-energy Photons. The use of filers can enhance the accuracy in film dosimetry for IMRT. In this regard, the use of optimal filter conditions is recommended.

Clinical Application of Stent-graft in Thoracic Aortic Diseases (흉부 대동맥 질환에서 스텐트-그라프트의 임상적 적용)

  • Kim, Kyung-Hwan;Lee, Cheul;Chang, Ji-Min;Chung, Jin-Wook;Ahn, Hyuk;Park, Jae-Hyung
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.698-703
    • /
    • 2001
  • Background: Endovascular stent-graft insertion in aortic diseases is now generally accepted as an attractive alternative treatment modality. We reviewed our clinical experiences of endovascular stent-graft insertion in thoracic aorta. Material and Method: Since 1995, we performed 8 cases of endovasclar stent-graft insertion. Preoperative diagnoses were aortic aneurysms in 4, traumatic aortic ruptures in 3, and ruptured aortic pseudoaneurysm in 1. All procedures were performed in angiography room with the guidance of fluoroscopy. The stent-graft device is a custom-made 0.35mm thickness Z-shaped stainless steel wires, intertwined with each other using polypropylene suture ligation. It is covered with expanded Dacron vascular graft. Result: All procedures were performed successfully. Follow-up studies revealed 2 minimal perigraft leakages. There was no significant leakage or graft migration. 2 patients expired due to multiple organ failure and fungal sepsis. Other survivors(6) are doing well. Conclusion: Endovascular stent-graft insertion is relatively saft and effective treatment modality in the managment of various types of aortic diseases. In may be an effective alternative in aortic diseases of great surgical risk.

  • PDF

The Effect of Aging Treatment for Microleakage within Composite Resin Restoration (시효처리가 복합레진 수복물의 미세누출에 미치는 영향에 관한 연구)

  • Yoo, Seunghoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.4
    • /
    • pp.283-295
    • /
    • 2013
  • In this study, researchers tried to find the effect, if any, of aging treatment to the specimens with three different dentin bonding agents using MicroCT. One, 5th generation - [Adper$^{TM}$ Single bond Plus] and two 6th generation [AdheSE$^{(R)}$, Adper$^{TM}$ Prompt$^{TM}$ L-Pop$^{TM}$] dentin bonding agents were used in this study. Specimens were divided into 4 groups according to aging treatment method used. Group I : control group, Group II : thermocycled between $5^{\circ}C$ and $55^{\circ}C$ for 60 seconds dwell time 5,000 times, Group III : aged as Group II and artificially brushed 20,000 times, Group IV : aged as Group III and were stored in artificial saliva for 6 months. With Single bond Plus, Group II showed more microleakage than Group I (p < 0.05). Group II and Group III showed more microleakage than Group IV (p < 0.05). There were no statistically significant differences among the groups using AdheSE$^{(R)}$ and Prompt$^{TM}$ L-Pop$^{TM}$ (p > 0.05). Among Group I, AdheSE$^{(R)}$ showed more microleakage than Single bond Plus and Prompt$^{TM}$ L-Pop$^{TM}$ (p < 0.05). Among Group II, there were no statistically significant differences (p > 0.05). Among Group III, AdheSE$^{(R)}$ showed more microleakage than Single bond Plus and Prompt$^{TM}$ L-Pop$^{TM}$ (p < 0.05). Among Group IV, AdheSE$^{(R)}$ and Prompt$^{TM}$ L-Pop$^{TM}$ showed more microleakage than Single bond Plus (p < 0.05).

True Digestibility of Phosphorus in Different Resources of Feed Ingredients in Growing Pigs

  • Wu, X.;Ruan, Z.;Zhang, Y.G.;Hou, Y.Q.;Yin, Y.L.;Li, T.J.;Huang, R.L.;Chu, W.Y.;Kong, X.F.;Gao, B.;Chen, L.X.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.1
    • /
    • pp.107-119
    • /
    • 2008
  • To determine the true digestible phosphorus (TDP) requirement of growing pigs, two experiments were designed with the experimental diets containing five true digestible P levels (0.16%, 0.20%, 0.23%, 0.26% and 0.39%) and the ratio of total calcium to true digestible P (TDP) kept at 2:1. In Experiment 1, five barrows (Duroc${\times}$Landrace${\times}$Yorkshire) with an average initial body weight of 27.9 kg were used in a $5{\times}5$ Latin-square design to evaluate the effect of different dietary P levels on the digestibility and output of P and nitrogen. In Experiment 2, sixty healthy growing pigs (Duroc${\times}$Landrace${\times}$Yorkshire) with an average body weight (BW) of 21.4 kg were assigned randomly to one of the five dietary treatments (12 pigs/diet), and were used to determine the true digestible phosphorus (TDP) requirement of growing pigs on the basis of growth performance and serum biochemical indices. The results indicated that the true digestibility of P increased (p<0.05) linearly with increasing dietary TDP level below 0.26%. The true P digestibility was highest (56.6%) when dietary TDP was 0.34%. Expressed as g/kg dry matter intake (DMI), fecal P output increased (p<0.05) linearly with increasing P input. On the basis of g/kg fecal dry matter (DM), fecal P output was lowest for Diet 4 and highest (p<0.05) for Diet 5. The apparent digestibility of crude protein (CP) did not differ (p>0.05) among the five diets, with the average nitrogen output of 12.14 g/d and nitrogen retention of 66% to 74% (p>0.05), which suggested that there was no interaction between dietary P and CP protein levels. During the 28-d experimental period of Experiment 2, the average daily gain (ADG) of pigs was affected by dietary TDP levels as described by Eq. (1): $y=-809,532x^4+788,079x^3-276,250x^2+42,114x-1,759$; ($R^2=0.99$; p<0.01; y = ADG, g/d; x = dietary TDP, %), F/G for pigs by Eq. (2): $y=3,651.1x^4-3,480.4x^3+1,183.8x^2-172.5x+10.9$ ($R^2=0.99$; p<0.01; y = F/G; x = dietary TDP, %), and Total P concentrations in serum by Eq. (3): $y=-3,311.7x^4+3,342.7x^3-1,224.6x^2+195.6x-8.7$ (R2 = 0.99; p<0.01; y = total serum P concentration and x = dietary TDP, %). The highest ADG (782 g/d), the lowest F/G (1.07) and the highest total serum P concentration (3.1 mmol/L) were obtained when dietary TDP level was 0.34%. Collectively, these results indicate that the optimal TDP requirement of growing pigs is 0.34% of the diet at a total Ca to TDP ratio of 2:1.

Verification of Radiation Therapy Planning Dose Based on Electron Density Correction of CT Number: XiO Experiments (컴퓨터영상의 전자밀도보정에 근거한 치료선량확인: XiO 실험)

  • Choi Tae-Jin;Kim Jin-Hee;Kim Ok-Bae
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.105-113
    • /
    • 2006
  • This study peformed to confirm the corrected dose In different electron density materials using the superposition/FFT convolution method in radiotherapy Planning system. The experiments of the $K_2HPO_4$ diluted solution for bone substitute, Cork for lung and n-Glucose for soft tissue are very close to effective atomic number of tissue materials. The image data acquisited from the 110 KVp and 130 KVp CT scanner (Siemes, Singo emotions). The electron density was derived from the CT number (H) and adapted to planning system (Xio, CMS) for heterogeneity correction. The heterogeneity tissue phantom used for measurement dose comparison to that of delivered computer planning system. In the results, this investigations showed the CT number is highly affected in photoelectric effect in high Z materials. The electron density in a given energy spectrum showed the relation of first order as a function of H in soft tissue and bone materials, respectively. In our experiments, the ratio of electron density as a function of H was obtained the 0.001026H+1.00 in soft tissue and 0.000304H+1.07 for bone at 130 KVp spectrum and showed 0.000274H+1.10 for bone tissue in low 110 KVp. This experiments of electron density calibrations from CT number used to decide depth and length of photon transportation. The Computed superposition and FFT convolution dose showed very close to measurements within 1.0% discrepancy in homogeneous phantom for 6 and 15 MV X rays, but it showed -5.0% large discrepancy in FFT convolution for bone tissue correction of 6 MV X rays. In this experiments, the evaluated doses showed acceptable discrepancy within -1.2% of average for lung and -2.9% for bone equivalent materials with superposition method in 6 MV X rays. However the FFT convolution method showed more a large discrepancy than superposition in the low electron density medium in 6 and 15 MV X rays. As the CT number depends on energy spectrum of X rays, it should be confirm gradient of function of CT number-electron density regularly.

  • PDF

Enhancement of Immune Activities of Peptides from Asterias amurensis Using a Nano-encapsulation Process (나노 입자 불가사리 펩타이드의 면역 활성 증진)

  • Jeong, Hyang-Suk;Oh, Sung-Ho;Kim, Seoung-Seop;Jeong, Myoung-Hoon;Choi, Woon-Yong;Seo, Yong-Chang;Choi, Geun-Pyo;Kim, Jin-Chul;Lee, Hyeon-Yong
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.424-430
    • /
    • 2010
  • Immuno-modulatory activities of peptides from Asterias amurensis were investigated using a nano-encapsulation process. The molecular weights of the peptides in the range of 5-7 kDa were separated using Sephadex G-75 gel filtration. Eighty-five percent of the nano-particles were in the 300 nm range using dynamic light scattering. The cytotoxicity of the A. amurensis nano-particles against CCD-986sk human dermal fibroblast cells was 11.64% after adding 1.0 mg/mL of the samples, which was lower than that from the control (13.28% collagen). The secretion of $NO^-$ from macrophages was estimated as $40\;{\mu}M$ after adding 1.0 mg/mL of gelatin nano-particles, which was higher than the others. Prostaglandin $E_2$ production from UV-induced human skin cells decreased greatly to 860 pg/mL after adding 1.0 mg/mL of the samples. Confocal microscopy revealed that nano-particles effectively penetrated the cells within 1 hour. From these results, we consider that nano-encapsulation of the peptides from A. amurensis can improve their biological functions.