• Title/Summary/Keyword: Z-Factor

Search Result 598, Processing Time 0.025 seconds

Electrical Properties of $\{(Sr_xCa_{1-x})_{0.95-y-z}Bi_2Pb_{0.05+y}\}Ti_{1.02}O_3$ for SMD-type Dielectric Trimmer Condenser (SMD-type Trimmer Condenser용 $\{(Sr_xCa_{1-x})_{0.95-y-z}Bi_2Pb_{0.05+y}\}Ti_{1.02}O_3$)

  • Kang, D.H.;Cha, H.J.;Nam, K.C.;Hu, J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.597-600
    • /
    • 2002
  • Electrical properties of $\{(Sr_xCa_{1-x})_{0.95-y-z}Bi_2Pb_{0.05+y}\})Ti_{1.02}O_3$ ceramic were studied as a function of Sr/Ca ratio and Bi, Pb contents. Dielectric properties of specimens with different x, y, z values were explained in terms of ionic polarizability with Molecular Additionally Rules and Clausius-Mosotti equation. For the composition of $\{(Sr_{0.62}Ca_{0.38})_{0.90}Bi_{0.01}Pb_{0.09}\})Ti_{1.02}O_3$ and $\{(Sr_{0.62}Ca_{0.38})_{0.905}Bi_{0.015}Pb_{0.08}\})Ti_{1.02}O_3$, dielectric constant$({\varepsilon}_r)$, quality factor(Q) and temperature coefficient(TC) were 389, 3048, -1490 and 394, 1869, -1340 at 1MHz, respectively.

  • PDF

Sharing Economy: Generation Z's Intention Toward Online Fashion Rental in Vietnam

  • PHAM, Huong Trang;HOANG, Kim Thu;NGUYEN, Thi Thoa;DO, Phuong Huyen;MAR, Ma Tin Cho
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.3
    • /
    • pp.997-1007
    • /
    • 2021
  • The last decade has seen the emergence of the idea of "sharing economy" as people are more aware of environmental issues. Although clothing businesses applying the model of sharing consumption have emerged recently, less research effort has been invested in this topic, especially in investigating young consumers' intention. The purpose of this study is to investigate factors driving Generation Z consumers' behavioral intention toward online fashion rental. In this research, a conceptual framework is proposed based on the Theory of Planned Behavior and Technology Acceptance Model. To test the research model and hypotheses, a survey of 375 students and pupils was conducted in Vietnam. All the scales' reliability and validity were assessed through Cronbach's Alpha and confirmatory factor analysis. Structural equation modeling was used to assess the relationship among constructs. The study results showed that attitude toward behavior, subjective norm and perceived behavioral control were positive contributors to Gen Z's intention to use online fashion rental. Besides, the positive relationships between attitude and two other factors - perceived usefulness and perceived ease of use - were also highlighted. Moreover, the findings provided empirical evidence for supporting the positive impact of interpersonal influence, e-WOM, and influencer e-marketing on subjective norm.

On the origin of escape fractions of ionizing radiation from star-forming galaxies at high redshift

  • Yoo, Taehwa;Kimm, Taysun;Rosdahl, Joakim
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.73.2-73.2
    • /
    • 2019
  • The physical origin of low escape fractions of ionizing radiation derived from Lyman-break galaxies (LBGs) at z ~ 3 - 4 is a puzzle in the theory of reionization. We perform idealized disk galaxy simulations to investigate how galactic properties, such as metallicity and gas mass, affect the escape of Lyman continuum (LyC) photons using radiation-hydrodynamic code RAMSES-RT, with strong stellar feedback. We find that the luminosity-weighted escape fraction from a metal-poor (Z=0.002) galaxy embedded in a halo of mass Mh ~ 1011 M is 〈f3Desc〉 ~ 8%. However, when the gas metallicity is increased to Z=0.02, the escape fraction is significantly reduced to 〈f3Desc〉 ~ 1%, as young stars are enshrouded by their birth clouds for a longer period of time. On the other hand, increasing the gas mass by a factor of 5 leads to 〈f3Desc〉 ~ 4%, as LyC photons are only moderately absorbed by the thicker disk. Our experiments seem to suggest that high metallicity is primarily responsible for the low escape fractions observed from LBGs, supporting the scenario in which the escape fraction has a negative correlation with halo mass. Indeed, our simulated galaxy with the typical metallicity of LBGs (Z=0.006) shows the relative escape fraction of 8%, consistent with recent observations of galaxies with M1500 = -20.

  • PDF

The Prospects of Metaverse in the Public vs. Private Sector by Millennials and Generation Z: Citizen/Customer Relationship Management

  • Yooncheong CHO
    • The Journal of Industrial Distribution & Business
    • /
    • v.15 no.2
    • /
    • pp.1-10
    • /
    • 2024
  • Purpose: The aim of this study is to examine the factors influencing prospects toward for the metaverse in both the public and private sectors, focusing on the perspectives of millennials and generation Z that were rarely examined in previous studies. Research design, data and methodology: This study employed an online survey as its research methodology utilizing factor analysis, ANOVA, and regression analysis to test the formulated hypotheses. Results: The findings of this study reveal that factors such as citizen/customer relationship management, the application of metaverse in both in the public and private sectors. Moreover, the effect size of applying the metaverse to cities on prospects toward the Metaverse was notably higher in the public sector. The effect size of metaverse management for customer relationship management showed a greater impact in the private sector. Conclusions: The results carry significant managerial and policy implications. They shed light on how millennials and generation Z perceive the applications of the metaverse in relation to cities, products, and brands. Notably, the results suggest that application of the metaverse for cities and management of customer relationships for products and brands emerge as key factors influencing the prospect of the metaverse in the public and private sectors.

EFFECT OF C-FACTOR AND LAYERING TECHNIQUE ON THE CONTRACTION FORCE OF COMPOSITE RESIN RESTORATION TO TOOTH SURFACE (C-factor와 충전법이 복합레진의 중합 수축에 의한 치질에서의 수축 응력에 미치는 영향)

  • Lee, Bong-Kyu;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.233-243
    • /
    • 2006
  • The aim of this study was to investigate the relationship between the C-factor and shrinkage strain values of composite resin and examine the strain values in different incremental filling techniques. Experiment consisted two aims. First, we compared with strain value in two different C-factors(3.7 and 1.0). Second, we examined the strain values in three different filling techniques. The results of the present study can be summarized as follows : 1. High C-factor groups showed higher contraction stress values than low C-factor groups at 900 sec after polymerization. 2. Hybrid resin showed higher contraction stress values than flowable resin in high C-factor cavities. But contraction stress was not revealed significant difference between hybrid resin and flowable resin in low C-factor cavities (P>0.05). 3. Bulk felling with hybrid resin(Group 1) showed high contraction stress and lining with flowable resin followed hybrid resin (Group 5) showed lower contraction stress. 4. Contraction stress were increased during 900 sec after polymerization in high C-factor groups but decreased gradually after 900 sec. 5. Low C-factor groups showed tight marginal seal between resin and cavity wall but high C-factor groups showed gaps formed between resin and cavity wall in part. On the basis above results, layering techniques in high C-factor cavity showed advantages in reducing contraction stress and gap formation between cavity wall and resin restoration.

  • PDF

Comparison of Two Intramuscular Injection Techniques on the Severity of Discomfort and leasions at the Injection Site (근육주사법에 따른 주사부위의 불편감과 조직손상의 차이에 관한 연구)

  • 김경선
    • Journal of Korean Academy of Nursing
    • /
    • v.18 no.3
    • /
    • pp.257-268
    • /
    • 1988
  • The purpose of this study was to compare the effect of the Z-track intramuscular injection technique with the effect of the stand and intramuscular injection technique on the severity of discomfort and leasions at the injection site. The subjects of the study were 20 patients with only early tuber culosis excluding another abnormalities (a akin rash, allergy to topical use of alcohol, jaundice, edema, neurosensory abnormality, coagulation defects, obesity and thin). Data collection was done from Feb. 1 to March 15, 1988 by means of Korean Pain Measurement Tool, Visual Analogue Scale, and Objective measures of injection site lesions. The results of this study were as follows ; 1) Hypothesis 1 ; “The severity of subject discomfort is less following administration of the Z-track intramuscular injection technique than following administra tion injection technique.” was not sopported 2) Hypothesis 2 ; “The degress of severity subject discomfort is less following administration of the Z-track intramuscular injection technique than following administra tion of the standard intramuscular injection technique.” was not supported. 3) Hypothesis 3 ; “The severity of injection site lesions is less following administra tion of the Z-track intramuscular injection technique than following administration of the standard intramuscular injection techniques.” was not supported. 4) The terms that were selected included factor II (mild-moderate pain) of Ratio Scale Measuring Pain using Korean Pain Terms. In conclusion ; it was found that there was not a difference from the severity of subject discomfort between two groups, but the degress of severity of subject discomfort about following administration of the Z-t-rack intramuscular injection was tended to be declined. Therefore further studies suggest that the Z-track intramuscular injection technique can decrease the severity of discomfort in persons receiving frequently intramuscular injections. First of all, it is necessery to be developed an effective tool of discomfort measurement for the intramuscular injection in Korean.

  • PDF

A Novel z-axis Accelerometer Fabricated on a Single Silicon Substrate Using the Extended SBM Process (Extended SBM 공정을 이용하여 단일 실리콘 기판상에 제작된 새로운 z 축 가속도계)

  • Ko, Hyoung-Ho;Kim, Jong-Pal;Park, Sang-Jun;Kwak, Dong-Hun;Song, Tae-Yong;Cho, Dong-Il;Huh, Kun-Soo;Park, Jahng-Hyon
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.101-109
    • /
    • 2004
  • This paper presents a novel z-axis accelerometer with perfectly aligned vertical combs fabricated using the extended sacrificial bulk micromachining (extended SBM) process. The z-axis accelerometer is fabricated using only one (111) SOI wafer and two photo masks without wafer bonding or CMP processes as used by other research efforts that involve vertical combs. In our process, there is no misalignment in lateral gap between the upper and lower comb electrodes, because all critical dimensions including lateral gaps are defined using only one mask. The fabricated accelerometer has the structure thickness of $30{\mu}m$, the vertical offset of $12{\mu}m$, and lateral gap between electrodes of $4{\mu}m$. Torsional springs and asymmetric proof mass produce a vertical displacement when an external z-axis acceleration is applied, and capacitance change due to the vertical displacement of the comb is detected by charge-to-voltage converter. The signal-to-noise ratio of the modulated and demodulated output signal is 80 dB and 76.5 dB, respectively. The noise equivalent input acceleration resolution of the modulated and demodulated output signal is calculated to be $500{\mu}g$ and $748{\mu}g$. The scale factor and linearity of the accelerometer are measured to be 1.1 mV/g and 1.18% FSO, respectively.

Research of z-axis geometric dose efficiency in multi-detector computed tomography (MDCT 장치의 z-축 기하학적 선량효율에 관한 연구)

  • Kim, You-Hyun;Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.167-175
    • /
    • 2006
  • With the recent prevalence of helical CT and multi-slice CT, which deliver higher radiation dose than conventional CT due to overbeaming effect in X-ray exposure and interpolation technique in image reconstruction. Although multi-detector and helical CT scanner provide a variety of opportunities for patient dose reduction, the potential risk for high radiation levels in CT examination can't be overemphasized in spite of acquiring more diagnostic information. So much more concerns is necessary about dose characteristics of CT scanner, especially dose efficient design as well as dose modulation software, because dose efficiency built into the scanner's design is probably the most important aspect of successful low dose clinical performance. This study was conducted to evaluate z-axis geometric dose efficiency in single detector CT and each level multi-detector CT, as well as to compare z-axis dose efficiency with change of technical scan parameters such as focal spot size of tube, beam collimation, detector combination, scan mode, pitch size, slice width and interval. The results obtained were as follows ; 1. SDCT was most highest and 4 MDCT was most lowest in z-axis geometric dose efficiency among SDCT, 4, 8, 16, 64 slice MDCT made by GE manufacture. 2. Small focal spot was 0.67-13.62% higher than large focal spot in z-axis geometric dose efficiency at MDCT. 3. Large beam collimation was 3.13-51.52% higher than small beam collimation in z-axis geometric dose efficiency at MDCT. 4. Z-axis geometric dose efficiency was same at 4 slice MDCT in all condition and 8 slice MDCT of large beam collimation with change of detector combination, but was changed irregularly at 8 slice MDCT of small beam collimation and 16 slice MDCT in all condition with change of detector combination. 5. There was no significant difference for z-axis geometric dose efficiency between conventional scan and helical scan, and with change of pitch factor, as well as change of slice width or interval for image reconstruction. As a conclusion, for reduction of patient radiation dose delivered from CT examination we are particularly concerned with dose efficiency of equipment and have to select proper scanning parameters which increase z-axis geometric dose efficiency within the range of preserving optimum clinical information in MDCT examination.

  • PDF

Effect of coloring agent dryness on zirconia color (치과용 지르코니아 착색제의 건조정도가 지르코니아 색조에 미치는 영향)

  • Lee, Joo-Hee;Park, Jin-Young;Kim, Hae-Jung;Moon, Yun Hee;Kim, Woong-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.176-182
    • /
    • 2018
  • One of the most important factor of esthetic prosthesis is the color of the teeth. Zirconia is produced in the process of design, milling, coloring, drying, and sintering. The effect of the drying degree of zirconia colorant on the color tone is examined. For the experiment, a total of 45 zirconia specimens(15 for each) were fabricated by using cad/cam system. The zirconia specimens(L block(LAZOR), Z block(Zircos-E block posterior), A block(AlphaZ)) were then subjected to zirconia sintering in accordance with the manufacturer's instructions, using a chemical coloring agent to Non-drying(0sec), intermediate (10sec), and completely dried (10min) temperature holding times. The color tone was measured using a spectrophotometer. The results were analyzed with a One-way analysis of variance and the Tukey post-hoc test (${\alpha}=.05$) The $L^*$ values of L, A specimens, $a^*$ values of A specimens, and $b^*$ values of Z specimens were not statistically different according to the degree of drying (p>0.05), While the $L^*$ value of Z specimen, $a^*$ value of L, Z specimen, $b^*$ values of L, A specimens were statistically different according to the degree of drying(p <0.05). In conclusion, the drying of zirconia colourants improves zirconia brightness and increases the optical properties of the enamel.

Multiple-biometric Attributes of Biomarkers and Bioindicators for Evaluations of Aquatic Environment in an Urban Stream Ecosystem and the Multimetric Eco-Model (도심하천 생태계의 수환경 평가를 위한 생지표 바이오마커 및 바이오인디케이터 메트릭 속성 및 다변수 생태 모형)

  • Kang, Han-Il;Kang, Nami;An, Kwang-Guk
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.6
    • /
    • pp.591-607
    • /
    • 2013
  • The objectives of the study were to evaluate the aquatic environment of an urban stream using various ecological parameters of biological biomarkers, physical habitat quality and chemical water quality and to develop a "Multimetric Eco-Model" ($M_m$-E Model) for the ecosystem evaluations. For the applications of the $M_m$-E model, three zones including the control zone ($C_Z$) of headwaters, transition zone ($T_Z$) of mid-stream and the impacted zone ($I_Z$) of downstream were designated and analyzed the seasonal variations of the model values. The biomarkers of DNA, based on the comet assay approach of single-cell gel electrophoresis (SCGE), were analyzed using the blood samples of Zacco platypus as a target species, and the parameters were used tail moment, tail DNA(%) and tail length (${\mu}m$) in the bioassay. The damages of DNA were evident in the impacted zone, but not in the control zone. The condition factor ($C_F$) as key indicators of the population evaluation indicator was analyzed along with the weight-length relation and individual abnormality. The four metrics of Qualitative Habitat Evaluation Index (QHEI) were added for the evaluations of physical habitat. In addition, the parameters of chemical water quality were used as eutrophic indicators of nitrogen (N) and phosphorus (P), chemical oxygen demand (COD) and conductivity. Overall, our results suggested that attributes of biomarkers and bioindicators in the impacted zone ($I_Z$) had sensitive response largely to the chemical stress (eutrophic indicators) and also partially to physical habitat quality, compared to the those in the control zone.