• Title/Summary/Keyword: YAG

Search Result 1,405, Processing Time 0.028 seconds

Quantitative Elemental Analysis in Soils by using Laser Induced Breakdown Spectroscopy(LIBS) (레이저유도붕괴분광법을 활용한 토양의 정량분석)

  • Zhang, Yong-Seon;Lee, Gye-Jun;Lee, Jeong-Tae;Hwang, Seon-Woong;Jin, Yong-Ik;Park, Chan-Won;Moon, Yong-Hee
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.5
    • /
    • pp.399-407
    • /
    • 2009
  • Laser induced breakdown spectroscopy(LIBS) is an simple analysis method for directly quantifying many kinds of soil micro-elements on site using a small size of laser without pre-treatment at any property of materials(solid, liquid and gas). The purpose of this study were to find an optimum condition of the LIBS measurement including wavelengths for quantifying soil elements, to relate spectral properties to the concentration of soil elements using LIBS as a simultaneous un-breakdown quantitative analysis technology, which can be applied for the safety assessment of agricultural products and precision agriculture, and to compare the results with a standardized chemical analysis method. Soil samples classified as fine-silty, mixed, thermic Typic Hapludalf(Memphis series) from grassland and uplands in Tennessee, USA were collected, crushed, and prepared for further analysis or LIBS measurement. The samples were measured using LIBS ranged from 200 to 600 nm(0.03 nm interval) with a Nd:YAG laser at 532 nm, with a beam energy of 25 mJ per pulse, a pulse width of 5 ns, and a repetition rate of 10 Hz. The optimum wavelength(${\lambda}nm$) of LIBS for estimating soil and plant elements were 308.2 nm for Al, 428.3 nm for Ca, 247.8 nm for T-C, 438.3 nm for Fe, 766.5 nm for K, 85.2 nm for Mg, 330.2 nm for Na, 213.6 nm for P, 180.7 nm for S, 288.2 nm for Si, and 351.9 nm for Ti, respectively. Coefficients of determination($r^2$) of calibration curve using standard reference soil samples for each element from LIBS measurement were ranged from 0.863 to 0.977. In comparison with ICP-AES(Inductively coupled plasma atomic emission spectroscopy) measurement, measurement error in terms of relative standard error were calculated. Silicon dioxide(SiO2) concentration estimated from two methods showed good agreement with -3.5% of relative standard error. The relative standard errors for the other elements were high. It implies that the prediction accuracy is low which might be caused by matrix effect such as particle size and constituent of soils. It is necessary to enhance the measurement and prediction accuracy of LIBS by improving pretreatment process, standard reference soil samples, and measurement method for a reliable quantification method.

A STUDY ON THE RELATIONS OF VARIOUS PARTS OF THE PALATE FOR PRIMARY AND PERMANENT DENTITION (유치열과 영구치열의 구개 각부의 관계에 관한 연구)

  • Lee, Yong-Hoon;Yang, Yeon-Mi;Lee, Yong-Hee;Kim, Sang-Hoon;Kim, Jae-Gon;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.569-578
    • /
    • 2004
  • The purpose of this study was to clarify the palatal arch length, width and height in the primary and permanent dentition. Samples were consisted of normal occlusions both in the primary dentition(50 males and 50 females) and in the permanent dentition(50 males and 50 females). With their upper plaster casts were used and through 3-dimensional laser scanning(3D Scanner, DS4060, LDI, U.S.A.), cloud data, polygonization, section curve and loft surface, fit and horizontal plane were based to measure the palatal arch length, width and height(Surfacer 10.0, Imageware, U.S.A.). T-tests were applied for the statistical analyze of the data. The results were as follows : 1. In the measurement values, the values of the male were higher than those of the female except primary anterior palatal height. There were not only statistically significant differences in anterior palatal width(p<0.05) and posterior palatal width(p<0.01) in primary dentition but palatal width(p<0.05), anterior palatal length(p<0.01), middle and posterior palatal length(p<0.05) in permanent dentition between male and female. 2. In the indices of palate, there were statistically significant differences in height-length index(p<0.05) and width-length index(p<0.01) between male and female in primary dentition. In permanent dentition, there was statistically difference between male and female. 3. In the measurement values, posterior palatal width was increased most greatly. Posterior palatal height, anterior palatal width and anterior palatal length were followed by descending order. On the other hand, anterior palatal height and posterior palatal length were decreased. 4. In the indices of palate, the height-length index, the width-length index and posterior height-width index were increased, but the others were decreased.

  • PDF

Ambient CO2 Measurement Using Raman Lidar (라만 라이다를 이용한 대기 중 이산화탄소 혼합비 측정)

  • Kim, Daewon;Lee, Hanlim;Park, Junsung;Choi, Wonei;Yang, Jiwon;Kang, Hyeongwoo
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_3
    • /
    • pp.1187-1195
    • /
    • 2019
  • We, for the first time, developed a Raman lidar system which can remotely detect surface CO2 volume mixing ratio (VMR). The Raman lidar system consists of the Nd: YAG laser of wavelength 355 nm with 80 mJ, an optical receiver, and detectors. Indoor CO2 cell measurements show that the accuracy of the Raman lidar system is calculated to be 99.89%. We carried out the field measurement using our Raman lidar at Pukyong National University over a seven-day period in October 2019. The results show good agreement between CO2 VMRs measured by the Raman lidar (CO2 Raman Lidar) and those measured by in situ instruments (CO2 In situ) which located 300 m and 350 m away from the Raman lidar system. The correlation coefficient (R), mean absolute error (MAE), and root mean square error (RMSE) between CO2 In situ and CO2 Raman Lidar are 0.67, 2.78 ppm, and 3.26 ppm, respectively.

Development of Trimming Technology in High-fine Resistor Using U.V. Laser (자외선 레이저를 이용한 고정밀 저항체 가공기술 개발)

  • Noh, S.S.;Kim, D.H.;Chung, G.S.;Kim, H.P.;Kim, K.H.
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.358-364
    • /
    • 2002
  • In this paper, we used U.V.(wavelength, 355nm) laser for adjusting Pt thin films temperature sensor to $100{\Omega}$ at $0^{\circ}C$. Internationally, A-class tolerance of temperature sensor is $0.06{\Omega}$ at $0^{\circ}C$. This is under value of $0.15^{\circ}C$, actually, so high-fine trimming technology is essential to this process. The width of trimmed lines was about $10{\mu}m$ and the best trimming of Pt thin films of $1{\sim}1.5{\mu}m$ was carried out with power : 35mW, rep. rate frequency : 200Hz and bite size : $1.5{\mu}m$. And using photolithography process, 96 resistors were fabricated in $2"{\times}2"$ substrate as the proportion of $79{\sim}90{\Omega}$ and $91{\sim}102{\Omega}$ is 42.7% and 57.3%, respectively. As result of trimming resistors to the target value of $109.73{\Omega}$ at $25^{\circ}C$, 82.3% of resistors had the tolerance within ${\pm}0.30{\Omega}$ and the others(17.7%) were within ${\pm}0.06{\Omega}$ of A-class tolerance.

Relationship between production of exoenzymes and serotypes of Pseudomonas aeruginosa isolated from clinical specimens and hospital environments (녹농균(綠膿菌)의 균체외효소산생능(菌體外酵素産生能)과 그의 혈청형(血淸型)과의 관계(關係))

  • Moon, Hong-Yong;Cho, Yag-Ja
    • The Journal of the Korean Society for Microbiology
    • /
    • v.15 no.1
    • /
    • pp.47-54
    • /
    • 1980
  • Exoenzymes, protease(P) and elastase(E) produced by Pseudomonas aeruginosa are reported to have close relationship with pathogenicity of Pseudomonas aeruginosa. Productibility of exoenzymes P and E were studied and compared in environmental isolates from hospital environments and clinical isolates from various clinical specimens, also, the relationship between their enzyme production and serotype were reviewed. 1. Clinical isolates were typed into nine serotypes A, B, C, D, E, F, G, H and I. Serotype E had the highest incidence of 24%, followed by B with 16.8%, G, 15.1% and C, 9.3%. 2. Environmental isolates were, typed as serotype B, C, E, F, G, H, I, K and M. Serotype I had the highest incidence of 26.6%, followed by C, F and M each incidence of 14.3%. 3. In the typing of the above two groups, serotypes A and D were found only in the clinical isolates and serotypes K, and M were found only in the environmental isolates. Serotypes J and L were found in neither clinical isolates nor environmental isolates. 4. In the distribution of serotypes from various clinical specimens, serotype G among isolates from pus showed incidence of 20.4%, and serotypes E and B were 19.5% separately. Serotype E had incidence of 22.6% and 20.0% in urine and sputa respectively, showing a high rate compared to the other serotypes. 5. The incidence of strains producing both exoenzymes P and E was 77.8% in the preserved strains of clinical isolates and 76.2% in the environmental isolates. There were no significant difference between the two groups. 6. Serotypes A and H, which are preserved strains from clinical isolates showed productibility of both exoenzymes P and E, the other serotypes showed productibility of various combination of exoenzymes. Among the environmental isoaltes, production of both exoenzymes P and E were seen in serotypes E, F, G, H, I and K and no serotype produced only P or E. 7. In ability to produce exoenzymes of isolates from sources of various clinical specimens, strains producing both exoenzymes P and E were found most frequently in pus with incidence rate of 82.0%, followed by 80.0% in sputum and urine. 8. Almost all the fresh strains of clinical isolates were producers of both exoenzymes P and E.

  • PDF

A Case of Primary BALT Lymphoma Limited to the Trachea (기관에 국한되어 발생한 BALT 림프종 1예)

  • Oh, Hyun Jong;Kim, Hee Jeong;Hwang, Eun Mee;Kim, Do Young;Kim, Yang Hyun;Yoon, Hyoung Kyu;Moon, Hwa Sik;Park, Sung Hak;Song, Jeong Sup
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.2
    • /
    • pp.198-205
    • /
    • 2003
  • Primary pulmonary lymphoma is rare, especially lymphomas arising in and limited to the tracheal wall without pulmonary parenchymal involvement are extremely rare. Bronchus-associated lymphoid tissue (BALT) lymphoma accounts for the majority of tracheal lymphomas. BALT lymphoma reveals distinct clinicopathologic features and remains localized for prolonged periods. The diagnosis is made histopathologically. Optimal management of these rare lesions has not been established. But, chemotherapy and radiation therapy all have been tried with favorable short-time results. The prognosis of BALT lymphoma is relatively good. We present here a case of BALT lymphoma of the tracheal wall which had responded to bronchoscopic ND-YAG laser therapy and local radiation therapy.

Velocity Field Measurement of Flow Inside SNOUT of Zinc Plating Process ( I ) (용융아연 도금공정에서의 SNOUT 내부 유동장 해석 ( I ))

  • Shin, Dae Sig;Choi, Jayho;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.10
    • /
    • pp.1265-1273
    • /
    • 1999
  • PIV(Particle Image Velocimetry) velocity field measurements inside the snout of a1/10 scale model of the Zn plating process were carried out at the strip speed $V_s=1.5m/s$. Aluminum powder particles ($1{\mu}m$) and atomized olive oil ($3{\mu}m$) were used as seeding particles to simulate the molten Zinc flow and deoxidization gas flow, respectively. A pulsed Nd:Yag laser and a $2K{\times}2K$ high-resolution CCD camera were synchronized for the PIV velocity field measurement. From flow visualization study, it is found that the liquid flow in the Zn pot is dominantly governed by the uprising flow caused by the rotating sink roll, with its effect on the steel strip inside the snout largely diminished by installing of the snout. The deoxidization gas flow in front of the strip inside the snout can be characterized by a large-scale vortex rotating clockwise direction formed by the moving strip. In the rear side of the strip, a counter-clockwise vortex is formed and some of the flow entrained by the moving strip impinges on the free surface of molten zinc. The liquid flow in front of the strip is governed by the flow entering the snout, caused by the spinning sink roll. Just below the free surface a counter-clockwise vortex is formed near the snout wall. The moving strip affects dominantly the flow behind the strip inside the snout, and large amount of the liquid flow follows the moving strip toward the sink roll. The thickness of the flow following the strip is very thin in the front side due to the uprising flow, however thick boundary layer is formed in the rear side of the strip. Its thickness is increased as moving downstream toward the sink roll. Inside the snout, the deoxidization gas flow above the free surface is much faster than the liquid flow in the zinc pot. Due to the larger influx of the flow following the moving strip in the rear side of the strip, higher percentage of imperfection can be anticipated on the rear surface of the strip.

A review on inorganic phosphor materials for white LEDs (백색 발광다이오드(White LEDs)용 무기형광체 재료의 연구개발 현황)

  • Hwang, Seok Min;Lee, Jae Bin;Kim, Se Hyeon;Ryu, Jeong Ho
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.5
    • /
    • pp.233-240
    • /
    • 2012
  • White LEDs (light-emitting diodes) are promising new-generation light sources which can replace conventional lamps due to their high reliability, low energy consumption and eco-friendly effects. This paper briefly reviews recent progress of oxy/nitride host phosphor and quantum dot materials with broad excitation band characteristics for phosphor-converted white LEDs. Among oxy/nitride host materials, $M_2Si_5N_8$ : $Eu^{2+}$, $MAlSiN_3$ : $Eu^{2+}$ M-SiON (M = Ca, Sr, Ba), ${\alpha}/{\beta}$-SiAlON : $Eu^{2+}$ are excellent phosphors for white LED using blue-emitting chip. They have very broad excitation bands in the range of 440~460 nm and exhibit emission from green to red. In this paper, In this review we focus on recent developments in the crystal structure, luminescence and applications of the oxy/nitride phosphors for white LEDs. In addition, the application prospects and current trends of research and development of quantum dot phosphors are also discussed.

Optical properties of Yb3+ doped Y3Al5O12 single crystals derived by the Czochralski method according to growth atmosphere and doping concentration (Czochralski 법으로 성장된 Yb3+ doped Y3Al5O12 단결정의 성장 분위기 및 도핑 농도에 따른 광학적 특성)

  • Shim, Jang Bo;Lee, Young Jin;Kang, Jin Ki;Lee, Young Kuk
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.25 no.2
    • /
    • pp.68-73
    • /
    • 2015
  • Single crystals of $Yb^{3+}$ doped $Y_3Al_5O_{12}$ up to 25 at.% were grown by the Czochralski method. Using the pulling rate of 0.8 mm/h and the rotation rate of 10 rpm, single crystals with diameters of up to 40 mm and lengths up to 160 mm were obtained. The growth atmosphere was either pure nitrogen or the mixture of nitrogen and oxygen. The crystal was bluish green when using pure nitrogen and the crystal was colorless when using the mixture of 99 % nitrogen and 1 % oxygen. The concentration of $Yb^{3+}$ ions decreased with increasing the length of the crystal and $Yb^{3+}$ concentration of core area was slightly higher than the other areas in the compositional analysis. The fluorescence lifetime decreased with increasing the doping concentration of $Yb^{3+}$ ions.

Two Cases of Diagnosis and Removal of Endobronchial Hamartoma by Cryotherapy via Flexible Bronchoscopy

  • Sim, Jae Kyeom;Choi, Jong Hyun;Oh, Jee Youn;Cho, Jae Young;Moon, Eul Sun;Min, Hye Sook;Lee, Byung Hyun;Park, Min Seon;Hur, Gyu Young;Lee, Sung Yong;Shim, Jae Jeong;Kang, Kyung Ho;Min, Kyung Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.76 no.3
    • /
    • pp.141-145
    • /
    • 2014
  • Although endobronchial hamartoma is a rare benign tumor, most patients with endobronchial hamartoma have respiratory symptoms such as obstructive pneumonia, hemoptysis, cough, or dyspnea due to bronchial obstruction. It can cause irreversible post-obstructive pulmonary destruction, thus early diagnosis and treatment is very important. Recently, there have been cases of neodymium-doped yttrium aluminum garnet (Nd:YAG) laser and electrocautery procedures for bronchoscopic treatment of malignant or benign central airway obstruction with comparable therapeutic efficacy and few complications. Bronchoscopic cryotherapy is a newly developed technique for management of central airway obstruction. Moreover, it provides diagnostic methods with improving diagnostic yield and safety. We report two cases of endobronchial hamartoma, each diagnosed and definitively treated with bronchoscopic techniques. Endobronchial biopsy and removal was successfully performed by cryotherapy via flexible bronchoscopy without notable complications. Follow-up bronchoscopic examinations excluded residual or recurrent disease.