• Title/Summary/Keyword: Y-Stent

Search Result 472, Processing Time 0.031 seconds

Acute Respiratory Failure Derived From Subglottic Stenosis in a Patient with Relapsing Polychondritis (성문하 협착에 의해 급성 호흡부전이 발생된 재발성 다발성 연골염 1예)

  • Kim, Hyun-Jeong;Park, Won;Bae, Sung-Kwon;Kim, Sung-Soo;Lee, Yong-Hwan;Song, Jung-Soo;Cho, Jung-Il
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.3
    • /
    • pp.353-358
    • /
    • 2001
  • Relapsing polychondritis (RP) is rare, chronic, relapsing, and multisystemic inflammatory disease targeting the cartilaginous structures. Respiratory track involvement occurs in approximately half of the cases. Subglottic stenosis is a rare manifestation of RP. Here, we report a case of RP with a subglottic stenosis, resulting in acute respiratory failure. A 63-year old man was admitted complaining of multiple joint pain, general weakness, weight loss, throat pain, hoarseness, exertional dyspnea, and hearing difficulties. A laryngoscopy and neck CT revealed a subglottic stenosis. Four days after admission, he complained severe dyspnea resulting in acute respiratory failure. Immediately, a tracheostomy was done for airway preservation. After high dose steroid therapy, the general symptoms were improved. However, the subglottic stenosis was sustained. Thus, a laryngotracheal augumentation and stent insertion was performed. The speech valve was then replaced. The subglottic stenosis was managed with low dose steroid and monthly cyclophosphamide pulse therapy, and the patient has been followed up regularly.

  • PDF

Deep Vein Thrombosis Due to Hematoma as a Rare Complication after Femoral Arterial Catheterization

  • Kim, Minsoo;Lee, Jong-Young;Lee, Cheol Whan;Lee, Seung-Whan;Kang, Soo-Jin;Yoon, Yong Hoon;Om, Sang Yong;Kim, Young-Hak
    • Journal of Yeungnam Medical Science
    • /
    • v.30 no.1
    • /
    • pp.31-35
    • /
    • 2013
  • Hematoma is quite a common complication of femoral arterial catheterization. However, to the best of our knowledge, there have been no previous studies regarding deep vein thrombosis (DVT) caused by compression of a vein due to a hematoma. We report a case of a hematoma developing after femoral arterial catheterization and causing extensive symptomatic DVT. A 59-year-old male was seen in our Emergency Department with right lower leg swelling 15 days after coronary stent implantation performed using right femoral artery access. Computed tomographic (CT) scanning revealed a large hematoma (45 mm in its longest diameter) compressing the common femoral vein and with DVT from the right external iliac vein to the popliteal vein. Due to the extensive DVT involvement, we decided to release the compressed common femoral vein by surgical evacuation of the large hematoma. However, even following evacuation of the hematoma, as the DVT did not resolve soon, further mechanical thrombectomy and catheter-directed thrombolysis were performed. Angiography then showed nearly resolved DVT, and the leg swelling was improved. The patient was discharged with the anticoagulation medication, warfarin.

Acute decompensated heart failure and acute kidney injury due to bilateral renal artery stenosis (양측성 신동맥 협착증에서 발생한 급성 비대상성 심부전과 급성 신손상)

  • Jung, Ho Jin;Choi, Won Suk;Kang, Hyun Jae;Jung, Byung Chun;Lee, Bong Ryeol;Lee, Jong Joo;Lee, Jun-Young
    • Journal of Yeungnam Medical Science
    • /
    • v.32 no.2
    • /
    • pp.146-151
    • /
    • 2015
  • Atherosclerotic renal artery stenosis (RAS) may result in hypertension, azotemia, and acute pulmonary edema. We report on a renal angioplasty with stent placement for bilateral RAS in a patient with acute decompensated heart failure and acute kidney injury. A 67-year-old female patient was admitted to our hospital with acute shortness of breath and generalized edema. Echocardiography showed left ventricular wall motion abnormality and the follow up electrocardiography showed T wave inversion in the precordial leads. We performed a coronary angiography to differentiate ischemic heart disease from non-cardiac origin for the cause of the heart failure. The coronary angiography showed no significant luminal narrowing, but bilateral RAS was confirmed on the renal artery angiography, therefore, we performed renal artery revascularization. After the procedure, the pulmonary edema was improved and the serum creatinine was decreased. Two weeks later, an echocardiography showed improvement of the left ventricular systolic function.

Thromboembolic Events Associated with Electrolytic Detachment of Guglielmi Detachable Coils and Target Coils : Comparison with Use of Diffusion-Weighted MR Imaging

  • Kim, Myeong Jin;Lim, Yong Cheol;Oh, Se-Yang;Kim, Byung Moon;Kim, Bum-Soo;Shin, Yong Sam
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.1
    • /
    • pp.19-24
    • /
    • 2013
  • Objective : The purpose of this study was to retrospectively evaluate and compare the incidence of diffusion-weighted image (DWI) lesions between the Guglielmi detachable coil (GDC) and the Target coil for treating unruptured intracranial aneurysm. Methods : From 2010 to 2011, consecutive 222 patients with an intracranial aneurysm underwent coil embolization. Inclusion criterias were : 1) unruptured intracranial aneurysm, 2) one or more GDC or Target coils used with or without other coils, 3) DWI examination within 24 hours after coiling, and 4) coiling performed without a balloon or stent. Results : Ninety patients (92 cases) met the inclusion criteria. DWI lesions were detected in 55 (61.1%) of 90 patients. In the GDC group (n=44), DWI lesions were detected in 31 (70.5%). The average number of DWI lesions was $5.0{\pm}8.7$ (mean${\pm}$SD; range, 1-40) in aneurysm-related territory. In the Target coil group (n=48), DWI lesions were detected in 24 (50.0%). The number of DWI lesion was $2.1{\pm}5.4$ (range, 1-32) in aneurysm-related territory. There was no significant correlation between a number of coils and DWI lesions. No significant differences were also observed in the number of DWI lesions in each group. Conclusion : The GDC and Target coils, which have an electrolytic detachable system, showed no differences in the incidence of DWI lesion.

Treatment of the Superior Sagittal Sinus Thrombosis with the Mechanical Thrombectomy Using Stent-Retriever Device

  • Kim, Hoon;Kim, Seong Rim;Park, Ik Seong;Kim, Young Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.5
    • /
    • pp.518-520
    • /
    • 2016
  • Cerebral venous sinus thrombosisis an uncommon entity and its clinical presentations are highly variable. We present the case of superior sagittal sinus thrombosis. Although it was medical refractory, successfully treated with mechanical thrombectomy using the Solitaire FR device. A 27-year-old man who presented with venous infarction accompanied by petechial hemorrhage secondary to the superior sagittal sinus (SSS) thrombosis. Due to rapid deterioration despite of anticoagulation therapy, the patient was taken for endovascular treatment. We deployed the Solitaire FR device ($4{\times}20mm$) in the anterior portion of the thrombosed SSS, and it was left for ten minutes before the retraction. Thus, we removed a small amount of thrombus. But the sinus remained occluded. We therefore performed the thrombectomy using the same methods using the Solitaire FR ($6{\times}20mm$). Thus, we were successful in removing larger clots. Our case highlights not only that the mechanical thrombectomy using the Solitaire FR is effective in achieving revascularization both rapidly and efficiently available, but also that it might be another option in patients with cerebral venous sinus thrombosis who concurrently had rapid clinical deterioration with devastating consequences.

Efficacy of Balloon-Guiding Catheter for Mechanical Thrombectomy in Patients with Anterior Circulation Ischemic Stroke

  • Oh, Jae-Sang;Yoon, Seok-Mann;Shim, Jai-Joon;Doh, Jae-Won;Bae, Hack-Gun;Lee, Kyeong-Seok
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.2
    • /
    • pp.155-164
    • /
    • 2017
  • Objective : To evaluate the efficacy of balloon guiding catheter (BGC) during thrombectomy in anterior circulation ischemic stroke. Methods : Sixty-two patients with acute anterior circulation ischemic stroke were treated with thrombectomy using a Solitaire stent from 2011 to 2016. Patients were divided into the BGC group (n=24, 39%) and the non-BGC group (n=38, 61%). The number of retrievals, procedure time, thrombolysis in cerebral infarction (TICI) grade, presence of distal emboli, and clinical outcomes at 3 months were evaluated. Results : Successful recanalization was more frequent in BGC than in non-BGC (83% vs. 66%, p=0.13). Distal emboli occurred less in BGC than in non-BGC (23.1% vs. 57.1%, p=0.02). Good clinical outcome was more frequent in BGC than in non-BGC (50% vs. 16%, p=0.03). The multivariate analysis showed that use of BGC was the only independent predictor of good clinical outcome (odds ratio, 5.19 : 95% confidence interval, 1.07-25.11). More patients in BGC were successfully recanalized in internal carotid artery (ICA) occlusion with small retrieval numbers (<3) than those in non-BGC (70% vs. 24%, p=0.005). In successfully recanalized ICA occlusion, distal emboli did not occur in BGC, whereas nine patients had distal emboli in non-BGC (0% vs. 75%, p=0.001) and good clinical outcome was superior in BGC than in non-BGC (55.6% vs. 8.3%, p=0.01). Conclusion : A BGC significantly reduces the number of retrievals and the occurrence of distal emboli, thereby resulting in better clinical outcomes in patients with anterior circulation ischemic stroke, particularly with ICA occlusion.

Endovascular Treatment of Aneurysms Arising from the Proximal Segment of the Anterior Cerebral Artery

  • Ko, Jun Kyeung;Cha, Seung Heon;Lee, Tae Hong;Choi, Chang Hwa;Lee, Sang Weon;Lee, Jae Il
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.2
    • /
    • pp.75-80
    • /
    • 2013
  • Objective : Aneurysms arising from the proximal segment of the anterior cerebral artery (A1) are rare and challenging to treat. The aim of this study was to report our experience with endovascular treatment of A1 Aneurysms. Methods : From August 2007 through May 2012, eleven A1 aneurysms in eleven patients were treated endovascularly. Six aneurysms were unruptured and 5 were ruptured. One patient with an unruptured A1 aneurysm presented with subarachnoid hemorrhage due to rupture of an anterior communicating artery aneurysm. Procedural data, clinical and angiographic results were reviewed retrospectively. Results : All of the aneurysms were successfully treated with coil embolization. Six were treated with a simple technique while the remaining 5 required adjunctive technique : double catheters (n=2), balloon-assisted (n=2), and stent-assisted (n=1). The immediate angiographic control showed a complete occlusion in all cases. Procedure-related complication occurred in only one patient : parent artery occlusion, which was not clinically significant. All patients had excellent clinical outcomes but one patient was discharged with a slight disability. No neurologic deterioration or bleeding was seen during the follow-up period in this cohort of patients. Follow-up angiography (mean, 20 months) was available in ten patients and revealed stable occlusion in all cases. Conclusion : Endovascular treatment is a feasible and effective therapeutic modality for A1 aneurysms. Tailored microcatheter shaping and/or adjunctive techniques are necessary for successful aneurysm embolization because of the projection and location of A1 aneurysms.

Edge Extraction using Fuzzy Techniques in Coronary Artery Image (Fuzzy 기법을 이용한 관상동맥영상의 에지추출)

  • Kim, Seong-Hu;Lee, Ju-Won;Kim, Joo-Ho;Lee, Han-Wook;Jung, Won-Geun;Lee, Gun-Ki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.3
    • /
    • pp.585-590
    • /
    • 2012
  • Coronary Intervention treatment has become the core that is the test of cardiac catheterization to conduct treatment with Coronary Arteriography. Operators must be careful in Coronary Intervention treatment because the stent is inserted into the point of narrowing of blood vessel. So, the operator must correctly recognize the path of blood vessel to deal with the problems which are damages and ruptures of blood vessel, and there would be some errors of finding the path of blood vessel by bad qualify of the image. Therefore in this paper, median filtering is conducted by preprocessing to evaluate the performance of the effect of noise of the image that affects quality of the image and Fuzzy Edge Extraction Techniques is tested by using Soble Edge Extraction Techniques to compare the performance with The Fuzzy Edge Extraction Techniques. In result, the performance, removing the noise and extracting the signal of Fuzzy Edge Extraction Techniques using median filtering, demonstrates the superiority.

A Case of Renovascular Hypertension Controlled by Percutaneous Transluminal Renal Angioplasty with Balloon Dilatation (경피적 신동맥 혈관 성형술로 치료한 신혈관 고혈압증 1례)

  • Park, Sung-Woo;Jeong, Su-Ho;Jeong, Young-Sun;Jun, Yong-Hoon;Hong, Young-Jin;Lee, Ji-Eun
    • Childhood Kidney Diseases
    • /
    • v.12 no.1
    • /
    • pp.105-110
    • /
    • 2008
  • Renovascular hypertension results from a lesion that impairs blood flow to a part of or all, of one or both kidneys. Renal artery stenosis is the major cause of renovascular hypertension and the most common cause of treatable secondary hypertension. Recently, percutaneous transluminal renal angioplasty(PTRA) with or without stent placement, has become the preferred choice for correcting symptomatic renal artery stenosis since it is less invasive than surgical reconstruction. PTRA with balloons designed for the dilatation for the dilatation of the coronary artery can be tried in small sized renal artery stenosis. We report a case of renovascular hypertension in a 13-year-old male who had small sized renal artery stenosis. Hypertension was controlled by PTRA with balloon dilatation.

  • PDF

The relation of the bioprosthetic valve failure to its calcification (조직판막의 실패와 석회화에 관한 연구)

  • 홍유선
    • Journal of Chest Surgery
    • /
    • v.22 no.6
    • /
    • pp.1001-1012
    • /
    • 1989
  • In 1968, Carpentier and his associates introduced glutaraldehyde as a compound for preparing cardiac tissue valve, and this technique has provided a considerably more suitable and durable tissue valve substitute. To increase further durability of valve tissue, Reis and his colleagues designed a flexible stent to reduce the stress on the heterogeneous tissue valve mounted. However with the advent of more innovative mechanical valve currently, many bioprosthetic valves are being substituted by mechanical valves at our department of cardiothoracic surgery because of bioprosthetic valve failure. Main cause of bioprosthetic valves failure were calcification or/and tear of tissue valves. The purpose of this retrospective study is to clarify the relationship between the patients clinical profile during implantation of tissue valves and pathologic features of the failed bioprosthetic valve. From March, 1982 through June, 1988, 53 bioprosthetic heart valves that had been ex-planted from 45 patients at the department of cardiac surgery of Yonsei University Hospital were subjected to this study. The patients were 10 to 65 year-old [mean age: 30.3 yr] with 17 males and 28 females. Re-replacements of prosthetic valves were carried out twenty nine in mitral position, eight in aortic position and eight in both aortic and mitral position simultaneously. The grading and location for calcification of valves were verified by radiograms. The calcification of the explanted valves leaflets was graded from 0 to 4 plus according to Cipriano and associates method. The types of tear and perforation of leaflet were classified into four types as Ishihara has adopted initially in 1981. In younger age group under thirty three years, explanted tissue valves were significantly more affected in terms of grades of severity of valve calcification as compared with older age group [p < 0.035]. Valve calcification appeared more severe in male as compared to female [p< 0.002]. Ionescu-Shiley bovine pericardial bioprosthetic valves showed more severe calcification than Hancock porcine tissue valves [p< 0.035]. Calcium deposit was found very prevalent at the area of commissural attachment [86 % of all]. Type I of valve rupture was shown to be related with simultaneous calcification. However, the relation of explanted valve position, duration of implanted prosthetic valve, atrial fibrillation and anticoagulant therapy to the severity of bioprosthetic valve calcification were not significantly clear statistically [p > 0.05].

  • PDF