• Title/Summary/Keyword: Y-Stent

Search Result 472, Processing Time 0.023 seconds

Clinical Applications of Intracoronary OCT (Invited Paper) (심혈관 OCT의 임상적 응용)

  • Ha, Jinyong;Kim, Jung-Sun;Hong, Myeong-Ki
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • The most common cause of a heart attack is known as coronary artery disease, which narrows the arteries and reduces the blood flow to the heart. To treat coronary artery stenosis, percutaneous coronary intervention (PCI) (a nonsurgical procedure to install a stent, which holds the artery wall open) is performed. Intracoronary optical coherence tomography (OCT) is a catheter-based, invasive optical imaging system. To determine whether PCI is appropriate, and to perform stent evaluation in a catheterization laboratory, OCT examinations are carried out. This review details the fundamental principles and technological status of intracoronary OCT imaging, and discusses the ongoing clinical applications to determine the benefits of OCT-guided PCI.

Aorto-Esophageal Fistula Complicated by Esophageal Metalic Stent -A case report- (식도 내 금속 스텐트 삽입 후 발생한 대동맥 식도 누공 -치험 1례-)

  • 윤영철;조광현;김기봉;전희재;최강주;이양행;황윤호
    • Journal of Chest Surgery
    • /
    • v.35 no.6
    • /
    • pp.479-482
    • /
    • 2002
  • Aortoesophageal fistula induced by endoesophageal stent is rare; however, it is usually a fatal disorder, with few survivors reported. We report a case of a 32-year old female with aortoesophageal fistula after insertion of the esophageal stent in esophageal lye stricture who was successfully diagnosed with endoscopy and treated in a two-stage operation. In the first stage, we performed esophagectomy, primary repair of the fistula site in the descending thoracic aorta, and feeding gastrostomy. After the patient recovered well postoperatively, a retrosternal interposition of the right colon and cervical esophago-colo-grastostomy were performed, to re-establish the gastrointestinal tract.

Analysis and Experiment of Ultrasonic Vibration Mechanism using PZT Actuator for Precision Laser Machining (압전구동기를 이용한 정밀 가공용 초음파 진동장치 해석 및 실험)

  • Kim, Woo-Jin;Jeon, Yong-Ho;Cho, Sung-Hak
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.12
    • /
    • pp.1347-1352
    • /
    • 2011
  • Recently, as the aged population grows around the world, many medical instruments, devices, and their fabrication processes are developing. Among the devices, a drug delivery stent is a good example for precision machining. Conventional drug delivery stent has problem of the remaining polymer because the drug is coated on the surface with it. If the drug is impregnated into the micro hole array on the stent surface, the polymer can be perfectly eliminated. Micro sized holes are generally fabricated by laser machining however, the fabricated holes do not have an enough aspect ratio to contain the drug or a good surface finish to deliver the stend to blood vessel tissue. To overcome these problems, we propose a vibration-assisted machining mechanism with PZT (Piezoelectric Transducers) for abrication of micro sized holes better. The results indicated that the burr size can be significantly decreased with vibration assisted in nanosecond pulse laser drilling test.

Effectiveness and Safety of Mechanical Thrombectomy with Stent Retrievers in Basilar Artery Occlusion : Comparison with Anterior Circulation Occlusions

  • Hu, Soo Young;Yi, Ho Jun;Lee, Dong Hoon;Hong, Jae Taek;Sung, Jae Hoon;Lee, Sang Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.6
    • /
    • pp.635-643
    • /
    • 2017
  • Objective : Acute basilar artery occlusion (BAO) is associated with severe neurological dysfunction and high mortality rates. The benefits of mechanical thrombectomy in BAO have not been explored in recent clinical trials. Therefore, we analyzed outcomes of stent retriever mechanical thrombectomy for BAO, and compared with anterior circulation occlusions (ACO). Methods : In total, 161 consecutive patients (24 BAO, 137 ACO) who underwent mechanical thrombectomy with the stent retriever between January 2013 and August 2016 enrolled in our study. All patients underwent clinical assessment with the National Institutes of Health Stroke Scale (NIHSS) and modified Rankin scale (mRS). Radiological results were used to evaluate thrombolysis in cerebral infarction (TICI) scores and successful recanalization was defined by TICI 2b or 3. Results : Mean NIHSS scores at 24 hours and 30 days were significantly higher in the BAO group than the ACO group (p=0.021, p=0.001). mRS at 90 days was significantly higher in the BAO group (4.2) compared with the ACO group (3.0) (p=0.003). The BAO group (2.0) performed fewer stent retriever passages than the ACO group (2.7) (p=0.049). There were no significant differences between the two groups in terms of complications, but the BAO patients experienced a higher mortality (16.6%) rate than ACO patients (5.8%) (p=0.001). In subgroup analysis of BAO, patients with short procedure times achieved successful recanalization (p=0.001) and successfully recanalized patients exhibited more favorable mRS at 90 days (p=0.027). Conclusion : In our study, mechanical thrombectomy of BAO patients showed worse clinical outcome and higher mortality rate than ACO patients. However, mechanical thrombectomy with a stent retriever in BAO is an effective treatment, because successfully recanalized patients showed good clinical outcome in BAO patients.

Occurrence and Prognosis for the Thrombosis in the Drug-Eluting Stents and Bare-Metal Stents (약물 용출 스텐트와 일반 금속 스텐트에서 혈전증에 대한 발생과 예후)

  • Kim, In-Soo;Choi, Nam-Gil;Jang, Seong-Joo;Han, Jae-Bok;Jang, Young-Ill
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.7
    • /
    • pp.273-283
    • /
    • 2012
  • Drug-eluting stents (DES) have significantly reduced in-stent restenosis, compared to bare-metal stents (BMS). However, there remains concern for the increased risk of stent thrombosis (ST) associated with DES. The present study sought to evaluate the incidence, clinical characteristics and outcome of ST in patients with acute myocardial infarction (MI) during a 1-year follow-up. 80 patients who developed ST were divided into 2 groups according to stent type: group I (DES-ST, n = 57 ) and group II (BMS-ST, n = 23 ). There were no differences between group I and II in the overall incidence of ST (2.7% vs. 4.3%, p=0.064) and in the incidence of each type of ST: acute ST (8.8% vs. 2.3%), subacute ST (50.9% vs. 60.9%), late ST (19.3% vs. 8.7%), and very late ST (21.1% vs. 17.4%) (p=0.605). Predictors of 1-year mortality were the occurrence of ST (OR 8.12, 95% CI 2.83-23.61, p<0.001), left ventricular ejection fraction<40% (OR 6.41, 95% CI 2.42-16.96, p<0.001), and age${\geq}$75 years (OR 4.98, 95% CI 1.95-12.74, p=0.001).

Physical Properties of Covered Stent in Gastric Acid Environment: In Vitro Study (위산 환경에서 피막형 스텐트의 물성 변화)

  • Park, Sung Chul;Park, Nark-Soon;Kim, Dong-Gon;Nah, Jae-Woon;Jeen, Yoon Tae;Cho, Hye Jin;Kim, Eun Sun;Keum, Bora;Seo, Yeon Seok;Lee, Hong Sik;Chun, Hoon Jai;Um, Soon Ho;Kim, Chang Duck;Ryu, Ho Sang
    • Polymer(Korea)
    • /
    • v.38 no.3
    • /
    • pp.351-357
    • /
    • 2014
  • In membrane covered stent, occlusion and fracture from membrane degradation by gastric acid sometimes occurred. Therefore, we investigated the physical properties of membrane covered stent according to its ingredient and concentration in gastric acid environment. Membrane covered stents consisted of silicone and polyurethane with 15%, 18%, 20% concentrations were used. After incubating stents in a condition of pH 1.2, we checked any changes at every 3 weeks for 18 weeks. The changes of membrane surface, radial expansion and recovery force of stent were investigated. Coating thickness increased proportionally to an increase in ingredient concentration. Surface was evenly coated with silicone compared to the case with polyurethane and its homogeneity was excellent in a high concentration. Degradation was much severe in the case of polyurethane. The radial force of silicone was higher than polyurethane, and the decrease of radial and recovery force was higher in the case of polyurethane. In conclusion, high concentration of silicone membrane was more stable than polyurethane in acid environment of in vitro study.

Effect of Drug Eluting Uniformity for Biodegradable Stent by Solid Freeform Fabrication (쾌속조형기법을 이용한 생분해성 스텐트용 메쉬필름의 약물방출거동 효과)

  • Cheong, Sin Young;Kim, Yang Eun;Koh, Young Joo;Shin, Wang Soo;Lee, Jun Hee;Kim, Wan Doo;Yoo, Young Eun;Park, Su A
    • Polymer(Korea)
    • /
    • v.38 no.1
    • /
    • pp.93-97
    • /
    • 2014
  • Biodegradable drug-eluting stent has dual functions of supporting the lumen and treating internal tumor preventing the restenosis by releasing drug. In this study, the polycaprolactone (PCL) based three dimensional (3D) mesh loaded with paclitaxel (PTX) was presented by rapid prototyping (RP) technique of solid freeform fabrication (SFF) for biodegradable drug-eluting stent application. PCL has many advantageous properties such as good biocompatibility, good mechanical properties, and good drug permeability. PTX is widely used in the cancer treatment by inhibiting tumor cell proliferation. Analytical methods of HPLC and NMR were used for simultaneous quantification of PTX. Scanning electron microscopy (SEM) was performed to observe the architecture and morphologies of 3D mesh. The cytotoxicity assay results indicated released PTX's biological activity. This study provided that PCL based 3D mesh loaded with PTX by RP technique has great potential for biodegradable drug-eluting stent application.