• Title/Summary/Keyword: Xe contents

Search Result 21, Processing Time 0.03 seconds

The Effect of Working Gas Xex+Ne1-x on the Electro-optical Characteristics of AC PDP (AC PDP의 전기광학적 특성에 미치는 동작 Gas Xex+Ne1-x의 영향)

  • Park, Chung-Hoo;Yoo, Su-Bok;Lee, Don-Kyu;Lee, Hae-June;Lee, Ho-Jun;Kim, Jae-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.142-146
    • /
    • 2007
  • Nowadays, itis inevitable trend to use high Xe gas contents for increase luminous efficiency and luminance in plasma display panel. However, the increase of Xe gas contents causes the driving voltage, although the brightness is increase. In this paper, we study the characteristics of electro optical according to Xe gas contents and gas pressure. Electro-optical characteristics were investigated by the discharge voltage, luminance and luminous efficacy measurements, respectively. With some increasing Xe gas contents and pressure, the electro-optical properties increased. However, the characteristics of electro-optical begin to be saturated, when too high increased Xe gas contents and pressure.

Luminous Characteristics of AC-PDP with Ridged Dielectric Layer in Various Xe Contents (능선형상의 유전체 구조를 갖는 AC-PDP의 Xe 함량 변화에 대한 발광특성)

  • 남문호;김정민;최시영
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.8
    • /
    • pp.25-30
    • /
    • 2004
  • In this paper, we suggest a new front panel structure with ridged front panel dielectric layer and hollow gap. The proposed structure can decrease a driving voltage and increase Xe content due to strong electric fields. In the experiment, we have used 6" test panel with 10 %, 15 %, 20 %, 30 % and 50 % Xe contents and 450 torr gas pressure. When comparing with a conventional structure in Xe 10 %, the proposed structure with same Xe content decreased a firing and sustain voltage by about 74 V and 79 V, also the luminance and luminous efficacy of proposed structure with 50 % Xe content were improved by about 33 % and 50.9 %..9 %.

The Performance of AC PDP with Grooved Dielectric Structure in High Xe Contents

  • Kim, Tae-Jun;Bae, Hyun-Sook;Jeong, Dong-Cheol;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.88-90
    • /
    • 2003
  • We reported an AC PDP structure with grooved front panel dielectric layer. The structure exhibits low breakdown voltage, better luminance, and better endurance to crosstalk in high Xe contents. It also shows less luminous efficacy then conventional structure because of the thinner dielectric layer, but we can apply the higher Xe contents to the grooved dielectric structure, which results in the higher luminous efficacy. We made experiments with the Xe contents from 4 to16% and total gas pressure from 400 to 600Torr. The grooved dielectric structure shows the improvement of 20% luminous efficacy and 17% luminance. The firing voltages lower about 40V at 600Torr and Xe 12, 16%. The discharge characteristics of grooved dielectric structure are verified also with 2D simulation.

  • PDF

A Study of Discharge Characteristics in Xe-Ne Gas Mixture for ac PDP with Long Gap Hump Electrode (Long Gap Hump 전극구조를 가진 ac PDP에서의 Xe-Ne 가스의 방전 특성 연구)

  • Heo, Jong-Cheol;Ok, Jung-Woo;Lee, Don-Kyu;Lee, Hae-June;Lee, Ho-Jun;Park, Chung-Hoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.155-159
    • /
    • 2009
  • To increase the luminance and luminous efficacy in the discharge for alternating current plasma display panel (ac PDP), the increment of Xe contents and long discharge gap are necessary. However, the driving voltage and the cost of driving circuit increases in the high Xe contents and long discharge path condition. In this paper, a long gap ITO hump electrode (LGH) model for discharge cells of ac PDP is evaluated in the various Xe contents($5{\sim}20%$). The discharge voltage of LGH structure is lower about 30V than that of ITa reference structure with same main discharge gap. The LGH structure has lower power consumption and higher luminance than those of reference structure, respectively. Also, the luminous efficacy of LGH structure is higher about 20% than that of ITO reference structure in the 20% Xe contents.

A Study of the relationship between Discharge Characteristic and Xe gas contents (방전특성과 Xe gas와의 관계 분석 연구)

  • Lee, Young-Min;Lee, Don-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1542-1543
    • /
    • 2011
  • 휘도와 효율을 증가시키기 위해 Xe의 함유량을 높이는 연구가 계속해서 수행되고 있지만, Xe이 증가함에 따라 방전전압 또한 높아지는 문제는 여전히 해결하지 못하고 있는 실정이다. 본 논문 에서는 Xe gas 가 첨가됨에 따른 기체 방전의 특성을 실험 및 이차원 시뮬레이션을 통해 분석해 보았다. 방전 셀 내부에 Xe 가스가 첨가됨에 따라 방전의 휘도와 효율이 증가하게 되는 메커니즘을 분석하고 그에 따라 야기되는 방전전압의 증가 원인들을 고찰해 보았다.

  • PDF

A Simulation Analysis of the Discharge Characteristics with the Xe Gas Contents (Xe 가스 첨가에 따른 방전 특성 시뮬레이션 분석)

  • You, Il;Song, Young-Joo;Lee, Young-Min;Ok, Jung-Woo;Nahm, Choon-Woo;Lee, Don-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1650-1655
    • /
    • 2012
  • AC-PDPs have recently achieved good performance and their image quality can sufficiently compete with the LCD TV. However, it is necessary more effort to improve the luminance and luminous efficacy in the PDP technology. The gas mixture ratio plays a very important role in discharge characteristics, but the mechanism of gas discharge is complex and complicated. In this paper, we investigate the mechanism of gas discharge with Ne+Xe miture ratio through zero and two dimensional fluid simulation.

The effects of high Xe contents on the improvement of luminous efficacy of AC PDP with Segmented electrode in Delta color arrayed Rectangular subpixels(SDR)

  • Kim, Tae-Jun;Jeong, Dong-Cheol;Chung, Woo-Joon;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.79-82
    • /
    • 2002
  • In this paper, we investigate the characteristics of luminous efficacy as a function of Xe partial pressure in AC PDP. SDR structure has shown much larger increment of luminous efficacy compared with the conventional one especially below 10% Xe contents. The luminous efficacy around 4.0 lm/W is achieved with Ne-Xe10%, 400Torr in Monochrome green phosphor test panel under 10kHz continuous sustaining frequency.

  • PDF

A Study on the Relationships Between the Electrooptical Characteristics and Working Gas Xe+Ne+He (AC PDP의 전기광학적 특성과 동작 Gas $Xe_x+Ne_y+He_{1-y)$의 상관관계에 관한 연구)

  • Park, Chung-Hoo;Yoo, Su-Bok;Lee, Hae-June;Lee, Ho-Jun;Kim, Jae-Sung;Lee, Don-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1619-1625
    • /
    • 2007
  • The gas mixture ratio of PDP discharges plays a very important role in the discharge characteristics of a plasma display panel. The increase of Xe contents results in the increases of luminance and luminous efficiency while it also results in the increase of the breakdown voltage. The addition of He gas increases the brightness and the luminous efficiency. Especially, the luminance and the luminous efficiency have a maximum value when the partial pressure of He is about 10% of the total pressure for a standard plasma display panel with Xe fraction of $10\sim30%$.

The effect of Gas Mixture Ratio on Discharge Characteristics of an AC PDP Cell

  • Lee, Hae-June;Lee, D.K.;Choi, J.H.;Cho, Y.S.;Park, H.D.;Lee, H.J.;Park, C.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.171-174
    • /
    • 2005
  • Experimental measurements are reported and compared with the results of a two-dimensional fluid simulation for the investigation of the discharge characteristics regarding the change of the mixture ratio of Ne-Xe-He noble gases. The increase of Xe contents results in the increases of luminance and luminous efficiency while it also results in the increase of the breakdown voltage and the discharge time lag. The addition of He gas increases the brightness and the luminance efficiency. When Xe partial pressure is low, the luminance efficiency increases with the amount of He at the same total pressure. When Xe partial pressure is high, however, the luminance efficiency has a maximum value when the partial pressure of He is about 10% of the total pressure for a standard AC PDP cell with Xe fraction of $10{\sim}30%$.

  • PDF

Reduction of Temporal Image Sticking in AC Plasma Display Panels through the Use of High He Contents

  • Park, Choon-Sang;Kim, Sun-Ho;Kim, Jae-Hyun;Tae, Heung-Sik
    • Journal of Information Display
    • /
    • v.10 no.4
    • /
    • pp.195-201
    • /
    • 2009
  • The temporal dark- and bright-image sticking phenomena were examined relative to the He contents under 11% Xe content in the 50-in HD and FHD AC-PDPs with a ternary gas mixture (Xe-He-Ne). To compare the temporal dark- and bright-image sticking phenomena under various He contents, the differences in the disappearing time, display luminance, perceived luminance, infrared emission, color coordinate, color temperature, and discharge current before and after discharge were measured under 0, 35, 50, and 70% He contents. It was found that temporal dark- and bright-image sticking were reduced in proportion to the increase in He %. Thus, a high He content contributes to the reduction of temporal dark- and bright-image sticking.