• Title/Summary/Keyword: Xe

Search Result 530, Processing Time 0.032 seconds

Properties of Electron Temperature and Density in Inductively Coupled Plasma of Xenon (유도결합형 제논 플라즈마의 전자온도, 밀도 특성)

  • Her, In-Sung;Yang, Jong-Kyung;Lee, Jong-Chan;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.41-45
    • /
    • 2005
  • In this paper, parameters of electron temperature and density for the mercury-free lighting-source were measured to diagnosis and analyze in Xe based inductively coupled plasma(ICP). In results at several dependences of 20~100 mTorr Xenon pressure, 50~200W RF power and horizontal distribution were especially mentioned. When Xe pressure was 20mTorr and RF power was 200W, the electron temperature and density were respectively 3.58eV and $3.56{\times}10^{12}cm^{-3}$. The key parameters of Xe based ICP depended on Xe pressure more than RF power that could be verified. A high electron temperature and low electron density with a suitable Xe pressure are indispensible parameters for Xe based ICP lighting-source.

  • PDF

Implementation of Open Source-based SIC/XE Computer Simulator for Educational Laboratory (오픈소스 기반의 실습용 SIC/XE 컴퓨터 시뮬레이터의 구현)

  • Kim, Ju Hyun;Kim, Hyun Ah;Moon, Bongkyo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.11a
    • /
    • pp.2-5
    • /
    • 2017
  • 기존의 어셈블러는 시각적으로 불편하고 사용자 편의를 위한 기능을 제공하지 않으며 최신의 컴퓨터와의 호환성 문제가 있었다. 이러한 문제점들의 해결책으로 나온 SIC/XE 어셈블러 시뮬레이터 오픈 소스를 GitHub에서 클론하여 분석하고 테스트하였다. 본 논문에서는 오픈 소스 SIC/XE 어셈블러 시뮬레이터의 다양한 오류를 분석하고 이를 수정하였다. 또한 리터럴 테이블, 심볼 테이블, 목적코드 및 오류 메시지의 시각화를 통해 기존의 SIC/XE 어셈블러 시뮬레이터를 개선시켜 사용자 편의를 높인 학습용 SIC/XE 어셈블러 시뮬레이터를 구현하였다.

A Comparison Study of the Effect of Adding Ar or Kr Gas into the Conventional Gas Mixtures in a Matrix Type PDP

  • Khorami, Alireza;Ghanbari, Shirin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.748-751
    • /
    • 2009
  • This paper provides a novel scheme to enhance luminous efficiency within Plasma Display Panels (PDPs). The He-Xe or Ne-Xe mixtures are mainly used in conventional PDP cells, where their discharge characteristics exemplify different behavior. Significantly, the excitation efficiency in He-Xe is lower than that of the Ne-Xe mixture. This paper demonstrates that by adding a small quantity of Ar or Kr gas in Ne-Xe mixture increases cell efficiency, while for the He-Xe mixtures their cell efficiency is reduced.

  • PDF

A research of the discharge characteristics in Kr-Ne-Xe gas mixture of AC PDP (AC PDP에서 Kr-Ne-Xe 혼합가스의 방전 특성 연구)

  • Park, Hyun-Dong;Lee, Don-Kyu;Cho, Sung-Yong;Lee, Hea-June;Lee, Ho-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1574-1575
    • /
    • 2006
  • 보통의 AC PDP에서는 Ne, Xe 혼합가스를 사용한다. Xe %가 높아짐에 따라 PDP의 효율은 올라가지만 그와 함께 최초의 방전을 일으키는 방전 개시 전압 또한 올라간다. 이러한 이유로 실제 PDP에서 무한정 Xe %를 올릴 수는 없다. 그래서 우리는 Xe gas보다 원자번호가 낮은 불활성기체인 Kr gas를 첨가시킴으로써 동일한 효율에서 방전개시전압이 낮은 최적의 3원 가스 조성비를 찾아보았다.

  • PDF

Properties of Electron Temperature and Electron Density in Inductively Coupled Xenon Plasma (유도결합형 제논 플라즈마의 전자온도, 전자밀도 특성)

  • Her, In-Sung;Choi, Gi-Seung;Lee, Jong-Chan;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2418-2420
    • /
    • 2005
  • In this paper, parameters of electron temperature and density for the mercury-free lighting-source were measured to diagnosis and analyze in Xe based inductively coupled plasma(ICP). In results at several dependences of $20{\sim}100mTorr$ Xenon pressure, $50{\sim}200W$ RF power and horizontal distribution were especially mentioned. When Xe pressure was 20mTorr and RF power was 200W, the electron temperature and density were respectively 3.58eV and $3.56{\times}10^{12}cm^{-3}$. The key parameters of Xe based ICP depended on Xe pressure more than RF power that could be verified. A high electron temperature and low electron density with a suitable Xe pressure are indispensible parameters for Xe based ICP lighting-source.

  • PDF

Prediction of 123I production using the monte Carlo code MCNPX (몬테 칼로 전산코드 MCNPX를 이용한 I-123 생산량 예측)

  • Yoo, Jae jun;Kim, Gyehong;Kim, Byung il;Lee, Donghoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.816-818
    • /
    • 2014
  • Gas target chamber has been developed for producing $^{123}I$ which is radiopharmaceuticals for diagnosis of thyroid cancer, and modeled how to occur nuclear reaction between chamber and $^{124}Xe$ with energy 30MeV inside the gas target chamber by using the MCNPX. The beam energy was lost as the beam spread when beam hit inside the gas target chamber. The cooling water was used not to change the gas target chamber as loss of energy transfer to the thermal energy. Spiral cooling line was designed for cooling the target chamber efficiently. By using the c30 cyclotron, $^{124}Xe(p,2n)$, $^{124}Xe(p,n)$, $^{124}Xe(p,pn)$ nuclear reactions were studied. In this study, we predict the production yield.

  • PDF

Comparison of the fluid simulation with experimental data of excited Xe species density in PDP cell

  • Yang, Sung-Soo;Ko, Sang-Woo;Kim, Hyun-Chul;Mukherjee, Sudeshna;Lee, Jae-Koo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.739-742
    • /
    • 2003
  • We have compared 2-D and 3-D fluid simulation results of alternating current plasma display panel (AC-PDP) cell with experimentally measured two kinds of excited Xe species $Xe^{\ast}(^{3}P_{1})$ and $Xe^{\ast}(^{3}P_{2})$ characteristics. Although direct experimental access and diagnostics of the discharge in a PDP cell is problematic due to the small cell size, some of experimental technologies have made it possible to diagnose the behavior of excited Xe species [1, 2]. The simulation shows the similar characteristics to the experimental results in the excited Xe species density distribution and the number of excited Xe atoms in anode and cathode region. In certain cases, we obtained the arch-shaped discharge path between two sustain electrodes due to the additional pulse applied to address electrode analogous to experiment. This long path discharge induced higher luminous and discharge efficiency compared to the standard case.

  • PDF

Plasma Diagnosis of Ne:Xe, Ne:Ar Mixed Gases by Single Langmuir Probe in Inductively Coupled Plasma Light Source System (ICP 광원 시스템의 Ne:Xe, Ne:Ar 혼합가스의 단일탐침법을 이용한 플라즈마 진단)

  • Choi, Yong-Sung;Lee, Woo-Ki;Moon, Jong-Dae;Lee, Kyung-Sup;Lee, Sang-Heon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.91-95
    • /
    • 2006
  • In whole world consciousness of environment maintenance have increased very quickly for the end of the 20th century. To use and disuse toxic substances have been controled at the field of industry. Also the field of lighting source belong to environmental control. And in the future the control will be strong. In radiational mechanism of fluorescence lamp mechanism is the worst environmental problem. In radiational mechanism of fluorescence lamp mercury is the worst environmental problem root. In the mercury free lighting source system the Xe gas lamp is one type. And the Ne:Xe mixing gas lamp improvements firing voltage of Xe gas lamp. Purpose and subject of this study are understand, efficiency, ideal of Ne:Xe plasma which mercury free lamp. Before ICP was designed, basic parameters of plasma, which are electron temperature and electron density, were measured and calculated by Langmuir probe data. Property of electron temperature and electron density were confirmed by changing ratio of Ne:Xe.

  • PDF

The Analysis of Electron Transport Coefficients in Kr and Xe Atom Gas (Kr과 Xe 원자기체의 전자수송계수의 해석)

  • Jeon, Byung-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.8
    • /
    • pp.104-108
    • /
    • 2008
  • Accurate sets of electron collision cross sections and the electron transport coefficients for atoms and molecules are necessary for quantitative understanding of plasma phenomena Kr and Xe atom are used in many industrial applications, such as in PDP and fluorescent induction lamps(FILs). Therefore, we analysed and calculated the electron transport coefficients, the electron drift velocity W, the longitudinal and transverse diffusion coefficient $ND_L$ and $ND_T$, and the ionization coefficient $\alpha$/N in pure Kr and Xe gases over the wide E/N range from 0.001 to 500[Td] at 1[Torr] by two-tenn approximation of the Boltzmann equation.

The Electron temperature and Density properties of Mixing gas in ICP Lighting system(Ne:Xe, Ne:Ar) (ICP 광원 시스템의 Ne:Xe Ne:Ar 혼합가스의 전자온도 및 전자밀도의 특성 연구)

  • Choi, Gi-Seung;Lee, Jonh-Chan;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2424-2426
    • /
    • 2005
  • In whole world consciousness of environment maintenance have increased very quickly for he end of the 20th century. To use and disuse toxic substances have been controled at the field of industry. Also the field of lighting source belong to environmental control. And in the future the control will be strong. In radiational mechanism of fluorescence lamp mercury is the worst environmental problem. In radiational mechanism of fluorescence lamp mercury is the worst environmental problem root. In the mercury free lighting source system the Xe gas lamp is one type. And the Ne:Xe and Ne:Ar mixing gas lamp improvements firing voltage of Xe gas lamp. Purpose and subject of this study are understand, efficiency, ideal of Ne:Xe and Ne:Ar plasma which mercury free lamp. Before ICP was designed, basic parameters of plasma, which are electron temperature and electron density, were measured and calculated by langmuir probe data. Property of electron temperature and electron density were confirmed by changing ratio of Ne:Xe and Ne:Ar.

  • PDF