• Title/Summary/Keyword: XLPE power cable

Search Result 217, Processing Time 0.027 seconds

Detection and Localization of Neutral Wire Defect of XLPE Power Cable Based on The Time-Frequency Domain Reflectometry (시간-주파수 영역 반사파 계측법 기반 XLPE 전력 케이블의 중성선 결함 위치 측정 연구)

  • Lee, Chun-Ku;Kwak, Ki-Seok;Yoon, Tae-Sung;Park, Jin-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1790-1791
    • /
    • 2011
  • In this paper, the diagnosis system for detecting and localizing the neutral wire defect in an energized XLPE power cable is proposed. The neutral wire defect is detectd and localized by the time-frequency domain reflectometry. To extract the reflected signal from the neutral wire defect, the adaptive RLS filtering is introduced. To verify the proposed method, the experiments for detecting and localizing neutral wire defect in active XLPE power cable is conducted.

  • PDF

Electrical properties of XLPE and Semiconductor Materials for Power Cable (전력케이블의 가교폴리에틸렌과 반도전 재료의 전기적 특성)

  • Lee, Ju-Hong;Kim, Hyang-Kon
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.207-210
    • /
    • 2008
  • In this paper, we researched the dielectric properties and voltage dependence on slice XLPE sheet from 22[kV] and 154[kV] power cable. We studied effects for impurities and water for semiconductor shield through a dielectric properties experiment to estimate performance of insulating materials in power cable. Capacitance and $tan{\delta}$ of 22[kV], 154[kV] were 53/43[pF] and $7.4{\times}10^{-4}$, $2.1510^{-4}$. In these results, the trend was increased with the increase of temperature. The tan6 of XLPE/semiconductor layer was increased as compared with that of XLPE. Dielectric properties reliability of tan6 was small. Also, To improve mean-life and reliability of power cable in this study, we have investigated chemical properties showing by changing the content of carbon black that is semiconductive additives for underground power transmission. Specimens were made of sheet form with the three of existing resins and the nine of specimens for measurement. Chemical properties of specimens was measured by FT-ATR (Fourier Transform Attenuated Total Reflectance). The condition of specimens was a solid sheet. We could observe functional group (C=O, carbonyl group) of specimens through FT-ATR. From these experimental result, the concentration of functional group (C=O) was high according to increasing the content of carbon black. We could know EEA was excellent more than other specimens from above experimental results.

  • PDF

Evaluation of Breakdown Strength on the Locally Dented Power Cable (초고압 XLPE 케이블의 국부적 늘림에 대한 파괴강도 고찰)

  • Kim, Y.H.;Lee, S.J.;Cho, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.251-254
    • /
    • 2001
  • Internal and external forces may be applied on the power cable in the both process of transportation and installation. Even though the EHV power cables have the structure of metal sheath and plastic jacket etc. to minimize these negative influences, the unusual forces result in the unexpected deformation of the cable. Compressing moulded XLPE model cable sheets were prepared and locally dented with round-edge and square-edge tools. All data were analyzed employing Weibull distribution. The breakdown strength of dented molded specimens showed lower values than the normal ones by 10-60%.

  • PDF

Breakdown characteristics with temperature variation on XLPE 6.9kV cable insulator at power plants (발전소 6.9kV급 XLPE 케이블 절연재의 온도에 따른 절연파괴 특성분석)

  • Park, Noh-Joon;Yang, Sang-Hyun;Lee, Ki-Joung;Kong, Tae-Sik;Kim, Hee-Dong;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.79-79
    • /
    • 2010
  • In this paper, we present results of the dielectric breakdown test in various 6.9kV power cables used in power plants. The dielectric strength of the different conditioned cables was measured by placing the sliced cable sections in silicone oil bath with needle electrode. The results were analyzed by the Weibull distribution. The shape and scale parameters of the Weibull distribution for each cable sections under test were calculated and evaluated. Collected data base was applied to deterioration trend analysis and lifetime guide was also proposed.

  • PDF

Evaluation of Insulation Characteristics of Submarine Cables in Offshore Wind Farm by Excessive Tension (과도한 인장력에 따른 해상풍력단지 해저케이블의 절연 특성 평가)

  • Seung-Won Lee;Jin-Wook Choe;Ik-Su Kwon;Dong-Eun Kim;Hae‑Jong Kim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.3
    • /
    • pp.286-291
    • /
    • 2024
  • Research on aged insulation of cables by stress is constantly being considered for reliable and stable power transmission of offshore wind farms. This study aimed to evaluate the insulation characteristic of aged XLPE (cross-linked polyethylene) insulation for application of offshore wind farms. In this study, The XLPE insulation of cable was set as various mechanical strains. The XLPE insulation is exposed to the mechanical stress below yield strain of 5%, 10%, and 20%. Aged samples were tested by using the method of AC BDV (alternative current breakdown voltage), tensile strength, elongation, and SEM (scanning electron microscope) to obtain insulation characteristics. The experimental results show that the dielectric breakdown of the sample with a strain 20% was 50% lower than the unaged sample; thereby, demonstrating that the mechanical strain that occurred in the submarine cables can weaken the insulation characteristics. Therefore, mechanical strain should be monitored when laying and operating submarine cables for offshore wind farms.

Diagnostic Test of XLPE Ultra High Voltage Electric Power Cable (XLPE 특고압 전력케이블의 절연 진단)

  • Byun, Doo-Gyoon;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.122-126
    • /
    • 2002
  • A diagnostic test of 15.4kV cross-linked polyethylene(XLPE) ultra high voltage power cables from generator in the Soyanggang hydro electric power plant was conducted over 3 months, beginning April 2001. According to the results, in the case of the power cables from generator 1, there was little possibility of proceeding rapid1y to failure or defect because the data from diagnosis doesn't indicate any failure, deterioration or partial discharge. However, in the case of the power cables from generator 2, the. polarization index show a slight abnormal condition of the insulator that is not severe, and the deterioration was also identified as not severe. However, the partial discharge had an abnormal condition which was severe.

  • PDF

The Application of 154kV OF/XLPE Transition Joint (154kV OF/XLPE 케이블 이종접속함의 실선로적용)

  • Hwang, Soon-Chul;Choi, Jong-Hyeon;Oh, Jong-Ok;Goh, Chang-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.274-276
    • /
    • 1991
  • Since the successful development of 154kV XLPE cable in 1983, its commercial use has been drastically expanded due to technical advantages and high performance of insulation, Futhermore, the large conductor size of 1200ml and 2000ml has been mainly employed in Korea for the purpose of meeting the bulk power demand in urban area. However, it is highly required to solve the problems which can be occured at the level of the joints between the cables of different type such as between existing OF and XLPE cables.

  • PDF

Partial Discharge Characteristics of the XLPE/EPDM Interface in Power Cable Joint (전력케이블 접속재 XLPE/EPDM 계면의 부분방전 특성)

  • Cho, Kyung-Soon;Hong, Jin-Woong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.9
    • /
    • pp.780-786
    • /
    • 2007
  • This paper describes the influence on partial discharge characteristics of defects at the model XLPE/EPDM interfaces of power cable joints. The defects of void and copper which could inadvertently be present at the joint interface. We measured ${\Phi}-n,\;{\Phi}-q$ patterns by a computer-aided partial discharge measuring system. Several parameters i, e, maximum discharge $q_{max}$ [pC], average discharge q [pC/cycle], and average angle of discharge ${\Theta}g$ [deg] were found to depend upon the defect type varying applied voltage. As the result of time evaluation, partial discharges are small different at copper defects, but is decreasing obviously about 20 minutes at void defect. It considered that difference of magnitude of total positive discharge of Q+ [pC] and total negative discharge of Q- [pC] is SPMD(swarming pulsive micro discharges).

The International Standard Trends of MV Power Cable Installation Test and its Application on Korean Standard (지중배전케이블 준공시험 관련 국제규격 동향과 국내기준 개선 방안)

  • Lee, Jae-Bong;Jung, Yeon-Ha;Song, Il-Keun;Cho, Soung-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.1933-1937
    • /
    • 2008
  • XLPE insulated power cables are introduced in Korea in 1980s. The cable installation test has been carried out according to the Korean Technical Reference of Electrical Facilities. But recent research results shows DC Hipot test cannot detect the serious defects in XLPE insulated cables. VLF test is recommended as a installation test of XLPE insulated cables by CENELEC and IEEE standards in 1996 and 2001 respectively. We suggest to apply VLF test as an installation test for XLPE insulated MV cables in Korea.

Pre-qualification Test on 345kv XLPE Cable and Accessories (345kv XLPE절연 케이블의 장기 신뢰성 평가)

  • Kim, Jong-Won;Yu, In-Kee;Kim, Young;Lee, Ki-Soo;Choi, Bong-Nam;Yun, Duck-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1727-1729
    • /
    • 2002
  • To cope with increasing of electric power demand in metropolitan areas, large capacity underground power cables are needed. Under such situations, our company has developed 345kV XLPE insulated cable and accessories. As the final step of development of the 345kV XLPE cable and accessories, the pre-qualification test was carried out on the test line composed of cables, pre-fabricated joints, EB-Gs and EB-As. This paper sums up the pre-qualification test conditions and the results.

  • PDF