초음파 비선형 음향 효과 및 X-선 회절법을 이용한 2.25Cr-1Mo 강의 열화 손상 평가 (Evaluation of Thermal Degradation of 2.25Cr-1Mo Steel Using Ultrasonic Nonlinear Effect and X-ray Diffraction Method)

  • 김덕희;박은수;박익근;변재원;권숙인
    • 한국안전학회지
    • /
    • 제17권4호
    • /
    • pp.71-79
    • /
    • 2002
  • It was attempted to evaluate the degree of degradation of thermally aged 2.25-1Mo steek by ultrasonic monlinear parameter(UNP) measurement and X-ray diffraction analysis of extracted carbide. Artificial aging was performed to simulate the microstructural degradation in 2.25Cr-1Mo steel arising from long time exposure at $540{\circ}C$. Microstructural analysis (number of carbides per unit area) and measurements of mechanical properties(Vickers hardness, DBTT) and degradation evaluation parameters(UNP and intensity ration of X-ray diffraction peak of electrolytically extracted carbide) were performed. Both of UNP and intensity ratio of X-ray diffraction peak for M6C carbide to that of M23C6 carbide(IR) increased abruptly in the initial 1000 hour of aging and then changed little. UNP and IR were proposed as potential parameters to evaluate the degree of aging degradation of 2.25Cr-1Mo steel.

방사능 폭발물의 X-ray 영상판독에 관한 연구 (A Study on the X-ray Image Reading of Radiological Dispersal Device)

  • 정근우;박경진
    • 한국산업융합학회 논문집
    • /
    • 제27권2_2호
    • /
    • pp.437-443
    • /
    • 2024
  • The purpose of radiological Dispersal Device(RDD) is to kill people by explosives and to cause radiation exposure by dispersing radioactive materials. And It is a form of explosive that combines radioactive materials such as Co-60 and Ir-192 with improvised explosives. In this study, we tested and evaluated whether it was possible to read the internal structure of an explosive using X-rays in a radioactive explosive situation. The improvised explosive device was manufactured using 2 lb of model TNT explosives, one practice detonator, one 9V battery, and a timer switch in a leather briefcase measuring 41×35×10 cm3. The radioactive material used was the Co-60 source used in the low-level gamma ray irradiation device operated at the Advanced Radiation Research Institute of the Korea Atomic Energy Research Institute. The radiation dose used was gamma ray energy of 1.17 MeV and 1.33 MeV from a Co-60 source of 2208 Ci. The dose rates are divided into 0.5, 1, 2, and 4 Gy/h, and the exposure time was divided into 1, 3, 5, and 10 minutes. Co-60 source was mixed with the manufactured explosive and X-ray image reading was performed. As a result of the experiment, the X-ray image appeared black in all conditions divided by dose rate and time, and it was impossible to confirm the internal structure of the explosive. This is because γ-rays emitted from radioactive explosives have higher energy and stronger penetrating power than X-rays, so it is believed that imaging using X-rays is limited By blackening the film. The results of this study are expected to be used as basic data for research and development of X-ray imaging that can read the internal structure of explosives in radioactive explosive situations.

ORIGINAL ARTICLE - 이동형 구내방사선촬영기로 촬영한 치근단 방사선촬영과 파노라마방사선촬영의 흡수선량과 유효선량 평가 (A absorbed and effective dose from the full-mouth periapical radiography using portable dental x-ray machine and panoramic radiography)

  • 한원정
    • 대한치과의사협회지
    • /
    • 제50권7호
    • /
    • pp.420-430
    • /
    • 2012
  • Purpose: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for full-mouth periapical radiography using the portable dental x-ray machine and panoramic radiography Material and Method: Thermoluminescent chips were placed at 25sites throughout the layers of the head and neck of a tissue-equivalent human skull phantom. The man phantom was exposed with the portable dental x-ray machine and panoramic unit. During full-mouth periapical radiography the exposure setting was 60 kVp, 2 mA and 0.15 ~ 0.25 seconds, while during panoramic radiography the selected exposure setting was 72 kVp, 8 mA and 18 seconds. Absorbed dose measurements were obtained and equivalent doses to individual organs were summed using ICRP 103 to calculate of effective dose. Result: In the full-mouth periapical radiography, the highest absorbed dose was recorded at the mandible body follow with submandibular glands and cheek. Using panoramic unit, the highest absorbed dose was parotid glands and the following was back of neck and submandibular glands. The effective dose in full-mouth periapical radiography using portable dental x-ray machine was 46 ${\mu}Sv$. In panoramic radiography, the effective dose was 38 ${\mu}pSv$. Conclusion: It was recommended to panoramic radiography for general check in the head and neck area because that the effect dose in the panoramic radiography was lower than the dose in the full-mouth periapical radiography using portable dental x-ray machine.

기계적 합금화한 $\sigma$-VFe합금의 중성자 및 X선 회절에 의한 상분석 (Phase Analysis of Mechanically Alloyed $\sigma$-VFe Alloy Powders by Neutron and X-ray Diffraction)

  • 이충효;조재문;이상진;심해섭;이창희
    • 한국재료학회지
    • /
    • 제11권8호
    • /
    • pp.664-664
    • /
    • 2001
  • $\sigma$-VFe 금속간화합물에 대한 기계적 합금화(MA) 효과를 중성자 및 X선 회절법으로 조사하였다. MA 분말의 구조분석은 X선 회절(Cu-K$\alpha$) 린 중성자회절(HRPD, λ=1.835$\AA$)을 이용하여 행하였다. $\sigma$-VFe화합물의 MA시 큰 구조변화가 관찰되었으며, MA 60시간의 경우 Fe-Fe 훤자분포는 unit cell에 30개의 원자를 포함하고 있는 $\sigma$상의 tetragonal구조에서 $120^{\circ}C$이상에서 안정하게 존재하는 $\alpha$-(V,Fe) 고용체의 bcc 구조로 상변화함을 알 수 있었다. 또한 $\alpha$-VFe 화합물에 대한 중성자 및 X선 회절패턴의 비교분석을 행하였으며 그 결과 $\sigma$상이 가지는 화학적 규칙성에 기인하는 (101)과 (111) 회절 피크가 중성자 회절에서 뚜렷하게 관찰됨을 알 수 있었다.

영상의학과 엑스선 발생장치의 누설 및 산란선량 측정 (Leakage and Scattered Radiation from X-ray Unit in Radiography)

  • 임인철;이재승;권대철
    • 한국방사선학회논문지
    • /
    • 제5권3호
    • /
    • pp.155-159
    • /
    • 2011
  • 이 연구의 목적은 방사선 발생 장치에 의한 환자나 작업 종사자들의 피폭과 사용시설에 대한 방어 상태를 조사하는데 있다. 수도권 대학병원의 엑스선 발생장치들을 대상으로 관전압 80 kVp, 관전류 200 mA, 1 sec의 최대 조사조건하에서 제어실출입문, 제어실감시창, 촬영실출입문, 인접주위 등에서 측정하였다. 주당누설선량은 제어실 출입문에서 0.11 mR/week, 제어실 감시창에서 0.15 mR/week, 촬영실 출입문에서 0.12 mR/week, 인접 주위에서 0.06 mR/week로 측정되었다. 그리고 주당평균누설선량은 0.11 mR/week 이었다. 구해진 주당평균누설선량은 기준치 100 mR/week 이하로 나타났으나 누설선량은 주기적인 측정으로 관리가 필요할 것으로 생각된다.

마이크로 X-ray CT를 활용한 알루미늄 개방형 폼의 형상 및 압축 거동 분석 (Analysis of 3D Geometry and Compressive Behavior of Aluminum Open Cell Foam Using X-ray Micro CT)

  • 김영일;김지훈;이종국;김대용
    • 소성∙가공
    • /
    • 제20권7호
    • /
    • pp.518-523
    • /
    • 2011
  • The three dimensional geometries of an aluminum open cell foam before and after uniaxial compressive loading were investigated using the X-ray micro CT(computed tomography). Aluminum 6101-T6 open cell foams of 10, 20, 40 ppi (pore per inch) were considered in this work. After the serial sectioning CT images of aluminum foams were obtained from non-destructive X-ray images, the exact 3D structure were reproduced and visualized with commercial image processing program. The relative density ratio was around the 7.0 to 9.0 range, the unit cells showed anisotropic shapes having the different dimensional ratios of 1.1 to 1.3 between the rise and the transverse directions. The yield stress increased with the relative density ratio and the volumetric strain increased proportionally with compressive strain. The plateau stress in the compressive stress-strain curve was caused by the buckling of ligaments.

동물병원의 방사선발생장치 정도관리에 대한 연구 (Quality Control of Diagnostic X-ray Units for Animal Hospital)

  • 김상우;이지훈;박예슬;임재동;성열훈
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2010년도 춘계학술대회
    • /
    • pp.231-237
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using quality assurance (QA) and quality control (QC) of diagnostic X-ray units. The surveys for QA/QC, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The QA/QC included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. As a result, 44.44% of reproducibility of dose exposure was proper, 81. 25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test.

  • PDF

테라헤르쯔 전자파 의료 영상 기술 (Terahertz Transmission Images For Medical Applications)

  • Jaeyoung Ryu;Yuchul Jung;Seungyong Baek;Lee, Jongjoo;Kim, Joungho;Soontae Kwon
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2000년도 하계학술발표회
    • /
    • pp.118-120
    • /
    • 2000
  • Currently, x-ray is mostly used for the diagnosis of dental cavity and osteoporosis. The osteoporosis is broadly defined as a decrease in the amount of bone mass per unit volume of the bone. Clinically the manifestation of low bone mass presents a clinical problem to the general population as an increase in fracture risk and especially in aging population[1]. Although the amount of the irradiated x-ray to the human body for the clinical diagnosis is relatively small, the exposition of the x-ray to the human body should be minimized as much as possible, since the x-ray is an ionizing radiation. To investigate other possible systems replacing X-ray, ultrasonic imaging and MRI(Magneto-Resonance-Imaging) systems were studied. Unfortunately, an effective and safe diagnosis tool for detecting the dental cavity and the osteoporosis is currently lacking. (omitted)

  • PDF

치과용 초소형 X-선 튜브의 선량평가 (Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging)

  • 지윤서;김연우;이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제26권3호
    • /
    • pp.160-167
    • /
    • 2015
  • 의료용 x선 촬영 장치에 있어서 환자에게 피폭되는 선량이 가장 중요한 관심사 중의 하나이다. 본 연구팀에서는 전 세계 최초로 입안에 삽입이 가능한 초소형 x-선 영상 장치가 개발되었는데 이러한 영상장치를 임상에서 사용하기 위해서는 피폭 선량의 평가가 필수적이다. 따라서 본 연구에서는 신개념 치과용 영상장치의 선량을 평가하기 위하여 1) 돼지 턱뼈 팬텀을 직접 제작하여 영상의 질을 평가 하였고, 2) 실제 임상에서 사용가능한 촬영 조건을 결정하였으며, 3) 결정된 촬영 조건에서의 선량을 평가 하였다. 한국 식약처에서 제시하는 치근단 촬영에 대한 환자 선량 권고량(DRLs) 기준에 근거하여 새 개발 장비의 입사표면선량(ESD)와 면적선량(DAP) 측정 방법을 고안하고 각각의 선량 값을 측정하였다. 관전압이 45~55 kV, 관전류가 300 mA 까지 사용 가능한 xoft 사의 초소형 x선 튜브를 사용하였다. 사용된 검출기는 active area가 $72{\times}72mm$ 이고 픽셀 사이즈는 $48{\mu}m$ 이다. 제작된 돼지턱뼈 팬텀은 1 frame/sec의 조건하에 영상을 획득 하였으며, 촬영 조건 최적화를 위하여 관전류를 $20{\sim}80{\mu}A$로 변화시키면서 50 frame씩 영상을 획득하였다. 또한, 상용화 치과용 영상시스템(모델명: CS 2100, 제조사: Carestream Dental LLC 및 모델명: EXARO, 제조사: HIOSSEN)을 이용하여 돼지턱뼈 팬텀의 비교영상 평가를 시행하였다. CS 2100는 60 kV, 7 mA (노출시간:0.125 s)로 하였으며, EXARO는 60 kV, 2 mA로 설정하였다. 선량 평가는 광자극 형광 선량계를 이용하여 입사표면선량을 측정하였으며, 팬텀은 PMMA 재질의 제작된 원통형 팬텀을 이용하였다. 선량계는 팬텀 표면상의 조사야 내부에 2개 및 소스와의 5 cm 거리상에 1개를 위치하여 측정하였다. 빔 조사 조건은 51, 101, 141, $196{\mu}As$로 설정하였다. 면적선량은 소스와 검출기간의 거리가 5 cm 위치에 배치하여 측정하였으며, 이 때 촬영조건은, 관전류 41, 99, 144, 207, $276{\mu}As$의 조건하에서 측정하였다. 임상에서 적용 가능한 관전압과 관전류는 X-선 세기 8000~9000인 지점에서의 관전류 값인 0.051 mAs 이다. 상용화 장비와 영상비교를 한 결과, 개발 장비의 조사야가 훨씬 작음에도 불구하고 치아 및 치아 주위 조직의 영상이 더 우수함을 확인하였다. 또한, 영상 최적화 조사조건인 $51{\mu}As$에서 입사표면선량(ESD)은 식약처 및 IAEA의 권고치보다 훨씬 낮은 1.369 mGy 이다. 조사야 내부의 선량 분포는 표준편차 5~10% 내외로 균일성이 우수 하였다. 측정된 면적선량(DAP)은 $82.4mGy*cm^2$으로 상용화 장비보다 조사야가 훨씬 작음에도 불구하고 식약처의 권고치보다 낮은 값을 보였다. 이러한 연구를 통해서 새 개발 장비의 영상의 우수성과 기존 장비 대비 방사선량에 대한 저감 효과를 확인 할 수 있었으며 치과 장비 개발에 있어서 X선 특성 연구에 대한 기술과 노하우를 축적할 수 있었다.

인디움 제올라이트 A의 안티몬 흡착과 결정구조 (Crystal Structure of Antimony-sorbed Indium-exchanged Zeolite A)

  • 임우택;이현수;허남호
    • 분석과학
    • /
    • 제16권5호
    • /
    • pp.375-390
    • /
    • 2003
  • 인디움 (In)으로 완전히 이온교환 된 제올라이트 A (In-A)를 $350^{\circ}C$에서 6일 동안 안티몬(Sb)과 반응시켰다. 생성물은 EPXMA (electron-probe X-ray microanalysis)를 이용하여 관찰하였다. 인디움으로 이온교환 된 제올라이트 A (In-A)에 안티몬 (Sb)을 흡착시켜 얻은 생성물의 결정구조는 $21^{\circ}C$에서 입방공간군 Pm ${\bar{3}}m$으로 단결정 X-선 회절법을 이용하여 결정하였다. 생성물 $In_8Si_{12}Al_{12}O_{48}{\cdot}(In)_{1.35}(Sb)_{0.7}$ ($a=12.111(2){{\AA}}$, $R_1=0.071$, $R_2=0.067$)은 단위세포당 8개의 인디움 양이온들, 1.35개의 인디움 원자들, 그리고 0.7개의 안티몬 원자들을 가지고 있었다. 단위세포 1 ($In_8-A{\cdot}In$, 단위세포의 65%)에는 $(In_5)^{8+}$ 클러스터가 존재하였다. 단위세포 2 ($In_8-A{\cdot}(In)_2(Sb)_2$, 단위세포의 35%)에는 두 개의 $(In_3)^{2+}$ 클러스터와 한 개의 $(In_3Sb_2)^{7+}$ 클러스터가 large cavity 내에서 발견되었다.