• 제목/요약/키워드: X-ray unit

검색결과 560건 처리시간 0.031초

이동용 치과 X선 발생장치의 누설 및 산란 선량에 관한 연구 (Leakage and scattered radiation from hand-held dental x-ray unit)

  • 김은경
    • Imaging Science in Dentistry
    • /
    • 제37권2호
    • /
    • pp.65-68
    • /
    • 2007
  • Purpose: To compare the leakage and scattered radiation from hand-held dental X-ray unit with radiation from fixed dental X-ray unit. Materials and Methods: For evaluation we used one hand-held dental X-ray unit and Oramatic 558 (Trophy Radiologie, France), a fixed dental X-ray unit. Doses were measured with Unfors Multi-O-Meter 512L at the right and left hand levels of X-ray tube head part for the scattered and leakage radiation when human skull DXTTR III was exposed to both dental X-ray units. And for the leakage radiation only, doses were measured at the immediately right, left, superior and posterior side of the tube head part when air was exposed. Exposure parameters of handheld dental X-ray unit were 70 kVp, 3 mA, 0.1 second, and of fixed X-ray unit 70 kVp, 8 mA, 0.45 second. Results: The mean dose at the hand level when human skull DXTTR III was exposed with portable X-ray unit $6.39{\mu}Gy$, and the mean dose with fixed X-ray unit $3.03{\mu}Gy$ (p<0.001). The mean dose at the immediate side of the tube head part when air was exposed with portable X-ray unit was $2.97{\mu}Gy$ and with fixed X-ray unit the mean dose was $0.68{\mu}Gy$ (p<0.01). Conclusions: The leakage and scattered radiation from hand-held dental radiography was greater than from fixed dental radiography.

  • PDF

원격응급시스템에 적합한 X-ray 장치 개발 (The Development of X-ray Unit of Remote Emergency medical System)

  • 조동헌;구경완;양해술;한만석;한상옥
    • 조명전기설비학회논문지
    • /
    • 제20권6호
    • /
    • pp.49-54
    • /
    • 2006
  • 본 연구에서 개발된 X-ray 장치는 병원으로부터 원거리에 있는 응급환자를 진단하거나, 대형 사고에 의한 재난에서 환자를 분류하기 위한 목적으로 사용할 수 있도록 제작되었다. X-ray 사용 장소는 병원으로부터 먼 거리에 있기 때문에 AC220[V]를 사용할 수 없는 사고 현장이나, 이동 중인 구급차 내에서도 응급환자의 진료가 필요한 곳이다. 개발된 X-ray 장치는 다음과 같은 특성이 있다. 첫째, 콘덴서를 내장하여 구급차의 밧데리 전원 공급이 없는 경우에도 X-ray 촬영이 가능하도록 하여 산악지역이나 섬지역 등에서도 이용할 수 있도록 하였다. 둘째, DC 12[V] 전원으로 X-ray를 발생하여 촬영한 정보를 디지털 디텍터로 검출하여 파일 형태로 저장하여 사용할 수 있었다. 제어회로는 Pic16F84A를 사용하여 X-ray 발생 장치의 신뢰성을 확보하였고, 기능을 다양하게 제공할 수 있었다. 원격응급시스템에 적합한 X-ray 장치는 응급환자가 의사로부터 공간적으로 멀리 떨어져 있거나, 시간적으로 진단, 처방, 치료가 동시에 이루어지기 어려운 상황 등에 효율적으로 대처할 수 있는 장점이 있다.

이물질 검출을 위한 X-Ray 비파괴검사 장비 개발 (Development of X-ray Non-destructive Testing (NDT) Equipment for the Detection of Alien Substances)

  • 유영태;오준호;김진우
    • 한국기계가공학회지
    • /
    • 제18권8호
    • /
    • pp.60-66
    • /
    • 2019
  • This study aims to develop and manufacture a device for inspecting impurities in a sealed aluminum container using an X-ray technique. Two X-ray oscillators and detectors are used to detect the entire sample. The stage for sample movement was fabricated using two high-voltage generators and X-ray detectors arranged diagonally. In addition, the high-voltage generator is composed of a vacuum tube, a high-voltage generator, and circulating oil for cooling. It includes a control unit for controlling other equipment, a power supply unit, and a video output unit; the most important part of the X-ray is the X-ray generation part. In this study, a flat panel was used along with the aim of developing the detector part. In particular, the development of the scintillator introduced in this study is a primary focus. The developed scintillator can be combined with a lens and can then be assembled with a charge coupled device (CCD) sensor.

Effect of the amount of battery charge on tube voltage in different hand-held dental x-ray systems

  • Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • 제42권1호
    • /
    • pp.1-4
    • /
    • 2012
  • Purpose : Hand-held dental x-ray system is a self contained x-ray machine designed to perform intraoral radiography with one or two hands. The issue about its usage as general dental radiography is still in dispute. The aim of the present study was to assess the relationship between the amount of battery charge and the tube voltage in different handheld dental x-ray systems. Materials and Methods : Seven hand-held dental x-ray units were used for the study. Tube voltage was measured with Unfors ThinX RAD (Unfors Instruments AB, Billdal, Sweden) for 3 consecutive exposures at the different amount of battery charge of each unit. The average and the deviation percentage of measured kV from indicated kV of each unit were calculated. Results : Tube voltage of only 1 unit was 70 kV (indicated by manufacturer) and those of the others were 60 kV. Tube voltage deviation percentage from the indicated kV at the fully charged battery was from 2.5% to -5.5% and from -0.8% to -10.0% at the lowest charged battery. Conclusion : Tube voltages of all units decreased as the residual amount of the battery charge decreased. It is suggested that the performance test for hand-held x-ray system should be performed for the minimum residual charged battery as well as the full charged one. Persistent battery charging is suggested to maintain the proper tube voltage of the hand-held portable x-ray system.

종합병원 진단용방사선장비의 고장유형 분석 (Studies on Failure Kind Analysis of the Radiologic Medical Equipment in General Hospital)

  • 이우철;김정래
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제22권2호
    • /
    • pp.33-39
    • /
    • 1999
  • This paper included a data analysis of the unit of medical devices using mainternance recording card that had medical devices of unit failure mode, hospital of failure mode and MTBF. The results of the analysis were as follows : 1. Medical devices of unit failure mode was the highest in QC/PM such A hospital as 33.9%, B hospital 30.9%, C hospital 30.3%, second degree was the Electrical and Electronic failure such A hospital as 23.5%, B hospital 25.3%, C hospital 28%, third degree was mechanical failure such A hospital as 19.5%, B hospital 22.5%, C hospital 25.4%. 2. Hospital of failure mode was the highest in Mobile X-ray device(A hospital 62.5%, B hospital 69.5%, C hospital 37.4%), and was the lowest in Sono devices(A hospital 16.76%, B hospital 8.4%, C hospital 7%). 3. Mean time between failures(MTBT) was the highest in SONO devices and was the lowest in Mobile X-ray devices which have 200 - 400 failure hours. 4. Anverage failure ratio was the highest in Mobile X-ray devices(A hospital 31.3%, B hospital 34.8%, C hospital 18.7%), and was the lowest in Sono(Ultrasound) devices (A hospital 8.4%, B hospital 4.2%, C hospital 3.5%). 5. Failure ratio results of medical devices according to QC/PM part of unit failure mode were as follows ; A hospital was the highest part of QC/PM (50%) in Mamo X-ray device and was the lowest part of QC/PM(26.4%) in Castro X-ray. B hospital was the highest part of QC/PM(56%) in Mobile X-ray device, and the lowest part of QC/PM(12%) in Gastro X-ray. C hospital was the highest part of QC/PM(60%) in R/F X-ray device, and the lowest a part of QC/PM(21%) in Universal X-ray. It was found that the units responsible for most failure decreased by systematic management. We made the preventive maintenance schedule focusing on adjustement of operating and dust removal.

  • PDF

X-Ray Security Checkpoint System Using Storage Media Detection Method Based on Deep Learning for Information Security

  • Lee, Han-Sung;Kim Kang-San;Kim, Won-Chan;Woo, Tea-Kun;Jung, Se-Hoon
    • 한국멀티미디어학회논문지
    • /
    • 제25권10호
    • /
    • pp.1433-1447
    • /
    • 2022
  • Recently, as the demand for physical security technology to prevent leakage of technical and business information of companies and public institutions increases, the high tech companies are operating X-ray security checkpoints at building entrances to protect their intellectual property and technology. X-ray security checkpoints are operated to detect cameras and storage media that may store or leak important technologies in the bags of people entering and leaving the building. In this study, we propose an X-ray security checkpoint system that automatically detects a storage medium in an X-ray image using a deep learning based object detection method. The proposed system consists of an edge computing unit and a cloud-computing unit. We employ the RetinaNet for automatic storage media detection in the X-ray security checkpoint images. The proposed approach achieved mAP of 95.92% on private dataset.

응급의료에서 이용될 휴대용 디지털 X-ray 전원장치 개발 (The Development of Portable Digital X-ray Power Supply Unit for Emergency Medical Services)

  • 조동헌;구경완;양해술
    • 조명전기설비학회논문지
    • /
    • 제20권1호
    • /
    • pp.125-131
    • /
    • 2006
  • X-ray 발생 장치는 X-ray를 촬영할 수 있는 곳에 장착하는 고정 방식과 환자가 있는 병실로 장치를 움직여 X-ray를 촬영할 수 있도록 하는 이동 방식으로 구분할 수 있다. 환자의 상태에 따라 이동 방식은 매우 유용할 수 있지만 병원 내의 AC220[V]를 사용해야 하는 제약이 있었다. 병원으로부터 원거리에 있는 응급환자를 진단하거나 대형 사고에 의한 재난에서 환자를 분류하는 경우 응급 센터의 의사의 역할이 매우 제한적이었다. 따라서 본 연구는 사고 현장이나 이동 중인 구급차 내에서 X-ray 촬영이 가능한 X-ray 전원 장치를 개발하였고 다음과 같은 특성을 얻을 수 있었다. 첫째, X-ray를 발생하기 위한 장치의 전원은 휴대가 간편한 밧데리(DC12[V])를 사용하였다. 둘째, 제어회로는 PIC16F84A를 사용하여 X-ray 발생 장치의 신뢰성을 확보하였고 기능을 다양하게 제공할 수 있었다. 이 특성을 적용한 휴대용 디지털 X-ray발생 장치는 사고 현장에서 X-ray를 촬영하고 환자의 정보를 응급센터에 전달하여 의사의 적절한 처방을 받는 미래 지향적인 응급의료체제가 가능하도록 기여할 것으로 기대된다.

방사선발생장치 교육을 위한 시뮬레이터의 개발과 유용성 평가 (Development and Usefulness Evaluation of Simulator for Educational Radiation Generator)

  • 서정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권6호
    • /
    • pp.591-597
    • /
    • 2021
  • In the present study, we developed virtual reality education contents for radiation generator on radiation education field. The radiation generator was divided by module and even the X-ray exposure part was manufactured in detail for designing 3D models. The mechanical details of the X-ray exposure part, the function of adjusting field size of the X-ray, the function of moving the exposure part, and the demonstrating the principle of the X-ray tube were applied. For developing VR contents, the Unreal Engine was used. To evaluate the usefulness of virtual reality content, we used t-test by SPSS. The group used the simulator showed significantly higher levels of understanding of X-ray generation, X-ray irradiation unit composition, irradiation field size adjustment, irradiation unit position adjustment, and overall composition and function. We believe that this VR contents will be used well with radiation safe environment.

병원 규모별 진단용 X선 발생장치의 성능 평가 (A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size)

  • 박주훈;임인철;동경래;강세식
    • Journal of Radiation Protection and Research
    • /
    • 제34권1호
    • /
    • pp.31-36
    • /
    • 2009
  • 일부지역의 병원에 설치, 운영되고 있는 진단용 X선 발생장치틀 의원, 병원, 종합병원별로 관 전압, 관 전류/량, 조사기간, 조사선량 성능을 평가하여 측정방법과 기술을 배우고 중요성을 알리고자 한다. 진단용 X선발생장치를 그룹별로 10대씩 총 30대에 대하여 관전류/량, 조사시간측정기를 사용하여, 백분율평균오차로 평가하였고 그에 따른 조사선량의 재현성은 변동계수를 계산하여 평가하였다. 진단용 X선 발생장치 30대 중 부적합한 장치는 관전압정확도 시험에서 5대(16.7%), 관전류정확도시험에서 3대(10,0%), 관전류량정확도 시험에서는 4대(13.3%), 조사시간정확도 시험에서는 5대(16.7%), 조사선량의 재현성 시험에서는 7대(23.3%)로 조사되었다. 진단용 X선 발생장치를 관리규정에 의거하여 성능검사 결과에 의해 성능관리의 심각성을 알 수 있었고, 이에 주기적으로 실시하여야 함은 물론 안전하게 관리함으로써 환자 및 방사선관계종사자에 대하여 방사선으로 인한 방사선 피폭경감, 화질영상관리, 재촬영 감소 둥에 의해 환자에게 양질의 의료서비스를 제공하게 될 것이다. 따라서 정기적인 성능검사가 필요하다고 사료된다.

유방촬영용 X선장치의 선질 특성 (Measurement of X-ray Quality in Mammography Unit)

  • 이인자;김정민;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권2호
    • /
    • pp.5-10
    • /
    • 1998
  • In the mammography, X-ray beam quality is one of the most important factors. Using X-ray mammography unit model GE/CGR Senography 600T Senix H.F, Authors studied four subjects. 1. The aluminum attenuation rate in 30 kVp when used with or without compression plate. 2. HVLs at 5 different area of the X-ray field of $26{\sim}32kVp$. 3. HVLs to know the influence of corrected measurement or parallel measurement. 4. Film density with microdensitometer along and cross to the long axis of X-ray tube, in terms of the Heel effect in the X-ray field. The following results were obtained. 1. Beam quality of anode area was harder than cathode area. 2. The dose reduction rate of compression plate was approximately $65.5%{\sim}88.1%$ and the beam quality with compression plate was hardened up to 4kVp accordingly. 3. If the X-ray beam enters the attenuation plate obliquely, HVL was $2.6{\sim}2.9%$ harder than perpendicular to it. 4. Because of heel effect, the film density of cathode area is higher than anode area to film density of 0.5.

  • PDF