• Title/Summary/Keyword: X-ray safety management

Search Result 55, Processing Time 0.024 seconds

Rapid Screening of Naturally Occurring Radioactive Nuclides (238U, 232Th) in Raw Materials and By-Products Samples Using XRF

  • Park, Ji-Young;Lim, Jong-Myoung;Ji, Young-Yong;Lim, Chung-Sup;Jang, Byung-Uck;Chung, Kun Ho;Lee, Wanno;Kang, Mun-Ja
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.359-367
    • /
    • 2016
  • Background: As new legislation has come into force implementing radiation safety management for the use of naturally occurring radioactive materials (NORM), it is necessary to establish a rapid and accurate measurement technique. Measurement of $^{238}U$ and $^{232}Th$ using conventional methods encounter the most significant difficulties for pretreatment (e.g., purification, speciation, and dilution/enrichment) or require time-consuming processes. Therefore, in this study, the applicability of ED-XRF as a non-destructive and rapid screening method was validated for raw materials and by-product samples. Materials and Methods: A series of experiments was conducted to test the applicability for rapid screening of XRF measurement to determine activity of $^{238}U$ and $^{232}Th$ based on certified reference materials (e.g., soil, rock, phosphorus rock, bauxite, zircon, and coal ash) and NORM samples commercially used in Korea. Statistical methods were used to compare the analytical results of ED-XRF to those of certified values of certified reference materials (CRM) and inductively coupled plasma mass spectrometry (ICP-MS). Results and Discussion: Results of the XRF measurement for $^{238}U$ and $^{232}Th$ showed under 20% relative error and standard deviation. The results of the U-test were statistically significant except for the case of U in coal fly ash samples. In addition, analytical results of $^{238}U$ and $^{232}Th$ in the raw material and by-product samples using XRF and the analytical results of those using ICP-MS ($R^2{\geq}0.95$) were consistent with each other. Thus, the analytical results rapidly derived using ED-XRF were fairly reliable. Conclusion: Based on the validation results, it can be concluded that the ED-XRF analysis may be applied to rapid screening of radioactivities ($^{238}U$ and $^{232}Th$) in NORM samples.

Ground Security Activities for Prevention of Aviation Terrorism -Centered on San Francisco International Airport of the U.S.A.- (항공테러방지를 위한 지상 보안활동 -미국 샌프란시스코국제공항을 중심으로-)

  • Kang, Maeng-Jin;Kang, Jae-Won
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.2
    • /
    • pp.195-204
    • /
    • 2008
  • With the growth of airline management, as well as computer and IT security, the international trade in this modern society has been rapidly increasing, Along with the advancing, airplanes have become a universal means of communication. However, the complications associated with airplane safety have also been brought up as a result, the most concerning of which is terrorism. One of the main counterplans for preventing terrorism is Ground security activities the core of Ground security activities is absolute safety for passengers in both passenger terminal and freight terminal. Subastral security refers to physical protection, proximity control and 100% security search and freight guarding of the passengers' possessions, and the personnel's duties to perform such jobs are be! coming more crucial. On the other hand, Airport security check has bee n gradually developing since the 1960's, when hijacking began to take place. Although the airports have been providing more safe and comfortable services to their customers, terrorism is still happening today. When Ground security activities is minute, the users feel displeasure and discomfort, yet considering solely their convenience can brings problems in achieving safety. Since the 9.11 terror in 2001, the idea of improving and strengthening airport security was reinforced and a considerable amount of estate is being spent today for invention and application of new technology. Various nations, including the United States, have been improving their systems of security through public services; public police department is actively carrying out their duties in airports as well. In San Francisco International Airport, private police department is in charge of collection of data, national events, VIP protection, law enforcement, cooperation within facilities, daily-based patrol and traffic control. Under guidance and supervision of national organizations, such as TSA, general police department interprets X-Rays, operates metal detectors, checks passports or IDs and observes reactions to explosives. Under these circumstances, studies about advancement of cooperation and duties of general police department and private police department necessitated: especially about private police department and their training for searching equipments, decrease in number of turn over rate, invention of technology and prior settlement in estate for security. The privacy of the public, who make up the major population of airport passengers, must also be minimized. In the following research, the activities of police departments in San Francisco International Airport will be analyzed in order to understand recent actions of the United States on airport security.

Effectiveness Evaluation of the Tube Voltage Measurement by using Additional Filter (부가필터를 이용한 kVp 측정의 실효성 평가)

  • Hwang, Jun-Ho;Lee, Kyung-Ho;Choi, Yoon-Bong;Kang, Byung-Sam
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.355-363
    • /
    • 2015
  • Advancement in the medical field provides an opportunity for the development of medical equipment and also enable accurate diagnosis for the inspection and the treatment of diseases. The aging of equipment due to the frequent operation produce uncertainty in the patient exposure dose, so a quality control was implemented by establishing a safety management system on a regular basis. The x-ray tube voltage (kVp), which is directly involved in the patient exposure dose and the life of the equipment, needs periodic performance for the quality control, but it has a limitation due to the time and the cost. In this study, we proposed a new method for measuring the kVp with ease by using the Y and Cu to solve the problem of the time and cost. We also evaluated the usefulness and the effectiveness of the new method and its accuracy through the kVp measurement. After securing the condition, the amount of the tube current and evaluating the usefulness and effectiveness of kVp measured using Y and Cu. The density range used was at 0.5-1.0, kVp was in the range of ${\pm}10%$, then, we recorded the change in concentration as % of Y and Cu. This experiment showed that when Cu and Y was at 75 kVp, concentration was the same, and when the kVp was changed to 65 ~ 85 %, a gradual increase in concentration to 85 ~ 110 % was noted.

An inquiry into dental personnel's Knowledge, attitude and behavior about the defense against dental radiation (치과 의료기관 종사자의 방사선 방어에 대한 지식, 태도 및 행위)

  • Kim, Sun-Ju
    • Journal of Korean society of Dental Hygiene
    • /
    • v.4 no.1
    • /
    • pp.15-29
    • /
    • 2004
  • The purpose of this study was to understand the relationship among knowledge, attitude, and behavior of dental personnel about the defense against dental radiation according to general features, and help them recognize the importance of defense against dental radiation. A questionnaire survey of 187 dental personnel who were working in 121 medical institutions such as university hospitals, general hospitals, hospitals, clinics, and public health centers in Seoul area was conducted from December 2002 to January 2003. Study findings are as follows: 1. The average knowledge score for the defense of radiation was 9.51(full score=14): By the demographic features, the know level for the defense of radiation was appeared to be different with the occupational category, age, academic background, workplace, year of working, and whether having the education of radiation or not. By questionnaire items, the knowledge for the defense of radiation was high in general, but for the item. 'the average amount of being bombed with radiation according occupations cannot be over 20mSv in a year for prescribed 5 years'. it was 18.7%: and for the item. 'the longer the length between focus and film. the less the amount of skin exposure', it was 40.6%. showing less knowledge for these two items. 2. The average attitude score for the defense of radiation was 64.24 (full score=75): By the demographic features, the attitude score was higher with respondents who were 31-35 years old. 11-15 years of working. and having radiation education. The attitude score by questionnaire items was generally high for all the items. 3. The average behavior score for the defense of radiation was 45.43: (a) By the demographic features, the behavior score for the defense of radiation was appeared to be higher with respondents who were dentists for occupational category, the aged for age, holding higher diploma for academic background, working in the university hospitals for workplace, and having longer occupational career for the year of working. (b) The behavior score for the defense of radiation by questionnaire items was lower than that of the attitude score for all the items. For the item, 'the amount of X-ray radiation is adjusted according to such conditions as patients' age, radiating areas, and kind of films', the score was 4.03; and for the item, 'Must receive the education of safety management of radiation periodically', the score was 1.73 and it was the lowest one. 4. As for the correlation among the knowledge, attitude, and behavior for the defense of radiation, the higher the level of knowledge and attitude, the higher the level of behavior.

  • PDF

Actual Condition of Quality Control of X-ray Imaging System in Primary Care Institution: focused on Gwangju Metropolitan City (1차 의료기관의 엑스선 발생장치 정도관리에 관한 현황조사:광주광역시 지역을 중심으로)

  • Dong, Kyung-Rae;Lee, Seun-Joo;Kweon, Dae-Cheol;Goo, Eun-Hoe;Jung, Jae-Eun;Lee, Kyu-Su
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.34-42
    • /
    • 2010
  • With the expanded use of radiation in modern medical practices, the most important issue in regards to efforts to reduce individual exposure dose is quality assurance. Therefore in order to study the present condition of quality assurance, the Gwangju Metropolitan City area was divided into five districts each containing ten hospitals. Four experiments were conducted: a reproducibility experiment for kVp, mA, and examination time (sec) intensity of illumination; half-value layer (HVL) measurement; and beam perpendicularity test matching experiment. The tube voltage reproducibility experiment for all fifty hospitals resulted in a 95.33% passing rate and mA and examination time both resulted in a 77.0% passing rate. The passing rate for intensity of illumination was 86.0% and 52.0% for HVL, which was the lowest passing rate of all four factors. For the beam perpendicularity test matching experiment, generally the central flux is matched to within $1.5^{\circ}$. Of all fifty hospitals 30.0% were beyond $3^{\circ}$. The results of the survey showed that 58% responded that they knew about quality assurance cycle. All fifty respondents stated that they have not received any training in regards to quality assurance at their current place of employment. Although quality assurance is making relative progress, the most urgent issue is awareness of the importance of quality assurance. Therefore, the implementation of professional training focusing on safety management and accurate quality assurance of radiation will reduce the exposure to radiation for radiologists and patients and higher quality imaging using less dosage will also be possible.