• 제목/요약/키워드: X-ray micro-computed tomography

검색결과 73건 처리시간 0.033초

소형 동물의 생체 촬영을 위한 고해상도 Micro-CT 시스템의 개발 (Development of High Resolution Micro-CT System for In Vivo Small Animal Imaging)

  • 박정진;이수열;조민형
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.95-101
    • /
    • 2007
  • Recently, small-animal imaging technology has been rapidly developed for longitudinal screening of laboratory animals such as mice and rats. One of newly developed imaging modalities for small animals is an x-ray micro-CT (computed tomography). We have developed two types of x-ray micro-CT systems for small animal imaging. Both systems use flat-panel x-ray detectors and micro-focus x-ray sources to obtain high spatial resolution of $10{\mu}m$. In spite of the relatively large field-of-view (FOV) of flat-panel detectors, the spatial resolution in the whole-body imaging of rats should be sacrificed down to the order of $100{\mu}m$ due to the limited number of x-ray detector pixels. Though the spatial resolution of cone-beam CTs can be improved by moving an object toward an x-ray source, the FOV should be reduced and the object size is also limited. To overcome the limitation of the object size and resolution, we introduce zoom-in micro-tomography for high-resolution imaging of a local region-of-interest (ROI) inside a large object. For zoom-in imaging, we use two kinds of projection data in combination, one from a full FOV scan of the whole object and the other from a limited FOV scan of the ROI. Both of our micro-CT systems have zoom-in micro-tomography capability. One of both is a micro-CT system with a fixed gantry mounted with an x-ray source and a detector. An imaged object is laid on a rotating table between a source and a detector. The other micro-CT system has a rotating gantry with a fixed object table, which makes whole scans without rotating an object. In this paper, we report the results of in vivo small animal study using the developed micro-CTs.

X-ray 단층촬영기법을 이용한 스트랜드보드의 내부공극구조에 관한 연구 (Internal Void Structure of Strandboard using X-ray Computed Tomography)

  • 오세창
    • Journal of the Korean Wood Science and Technology
    • /
    • 제36권6호
    • /
    • pp.13-22
    • /
    • 2008
  • 보드의 기계적 성질에 영향을 미치는 공극에 대하여 공극을 두가지로 분류하고 밀도에 따른 오에스비의 내부 공극구조의 특성에 대하여 살펴보고자 하였다. 스트랜드보드의 내부공극을 X-ray 단층촬영기로 측정하고 이미지분석 소프트웨어를 사용하여 밀도에 따른 공극의 분포와 공극의 함유량을 조사하였다. 측정 전에 보드의 밀도를 밀도측정기와 전건법으로 측정하였으며 이 두 방법에 의해 측정된 결과는 아주 높은 상관관계를 보여주었다. X-ray를 서로 다른 배율로 조사하여 획득한 이미지를 바탕으로 분석한 결과, 저해상도에서는 스트랜드간의 공극(macro-void)의 측정이 가능하나 스트랜드내의 미세공극(micro-void)은 이미지획득이 불가능하였다. 중해상도에서는 두가지 형태 모두의 이미지 획득이 가능하였고, 고해상도에서는 대부분의 미세공극 이미지의 획득이 가능하였다. 저배율을 채택하여 스트랜드간의 공극을 측정하고 스트랜드내의 미세공극은 관련식을 이용하여 추정하였다. 이를 통해 보드내부에 존재하는 스트랜드간의 공극분포를 파악할 수 있었으며 그 공극의 함유비율을 정확하게 산정할 수 있었다.

미세 X선 단층촬영 기법의 개발과 적용 (Development of X-ray Micro Computed Tomography and Applications)

  • 김승곤;임재홍;김보흠;이의재;이상준
    • 한국가시화정보학회지
    • /
    • 제8권2호
    • /
    • pp.45-50
    • /
    • 2010
  • The objective of this study is to elucidate the feasibility of synchrotron X-ray micro CT as a non-destructive imaging method to visualize the three-dimensional morphological structures of biological and non-biological samples. The experiments were conducted in 7B2 X-ray micro CT beamline in Pohang Accelerate Laboratory (PAL). A rotational 3-axis stage was specially designed for $0^{\circ}-180^{\circ}$ scanning of test samples. Preliminary tests were performed for opaque samples including a mosquito head, a plant seed and gas diffusion layer (GDL) of polymer electrolyte fuel cell to verify the feasibility of the X-ray micro CT. It visualized clearly the internal structure of all the test samples, supporting its usefulness.

3차원 X-ray 단층 화상을 이용한 스카른 광석의 정량분석 연구 (Quantitative Analysis of Skarn Ore Using 3D Images of X-ray Computed Tomography)

  • 정미희;조상호;정수복;김영훈;박재구
    • 한국광물학회지
    • /
    • 제23권3호
    • /
    • pp.211-217
    • /
    • 2010
  • 스카른 Zn-Pb-Cu 복합광석을 구성하는 주요 구성 광물의 정량분석을 목적으로, 마이크로 포커스 X-ray 단층촬영 장비를 이용한 스카른 복합광석의 3차원 비파괴검사를 수행하였다. X-ray 단층화상의 화상결함을 감소시키고자 제안된 화상보정법을 이용하여 화상들을 보정한 후에 3차원으로 재구성하였다. 주사전자현미경(SEM)에 의한 표면분석과 보정된 X-ray 단층화상을 비교하여 주요광물에 대한 CT 값의 범위를 결정하였다. 재구성화상 내 전체 광물의 체적비율을 분석한 결과, 황화광물 20.5%, 맥석광물 79.5%로 평가되었다. X-ray 3차원 단층화상 정량분석법은 광석 내 유용광물의 부존형상과 회수율 분석에 유용하게 적용될 것으로 기대된다.

소 동물 촬영을 위한 Micro-CT의 개발 (Development of a Micro-CT System for Small Animal Imaging)

  • Sang Chul Lee;Ho Kyung Kim;In Kon Chun;Myung Hye Cho;Min Hyoung Cho;Soo Yeol Lee
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권2호
    • /
    • pp.97-102
    • /
    • 2004
  • 소 동물 촬영에 이용될 수 있는 고해상도의 x-선 cone-beam micro computed tomography (micro-CT) 시스템을 개발하였다 Micro-CT 시스템은 120${\times}$120 mm2 의 2차원 평판 x-선 감지기, micro-focus x-선 발생장치, 주사 기구부, 병렬처리 영상 재구성 시스템으로 이루어져 있다. 개발된 시스템의 성능을 평가하기 위해 대조도와 공간해상도를 측정하였다. 대조도 실험에서는 95 mGy 에서 36 CT-번호를 구별할 수 있음을 확인하였고, 공간 해상도 실험에서는 14 lp/mm 의 성능을 확인하였다. 소 동물 촬영 결과로 실험용 쥐의 대퇴부, 심장 그리고 복부 동맥 혈관을 촬영한 경상을 제시하였다. 개발된 micro-CT 시스템은 소 동물을 이용한 생명공학 분야 연구에 널리 이용될 수 있을 것으로 기대된다.

3D Inspection by Registration of CT and Dual X-ray Images

  • Kim, Youngjun;Kim, Wontae;Lee, Deukhee
    • Journal of International Society for Simulation Surgery
    • /
    • 제3권1호
    • /
    • pp.16-21
    • /
    • 2016
  • Computed tomography (CT) can completely digitize the interior and the exterior of nearly any object without any destruction. Generally, the resolution for industrial CT is below a few microns. The industrial CT scanning, however, has a limitation because it requires long measuring and processing time. Whereas, 2D X-ray imaging is fast. In this paper, we propose a novel concept of 3D non-destructive inspection technique using the advantages of both micro-CT and dual X-ray images. After registering the master object’s CT data and the sample objects’ dual X-ray images, 3D non-destructive inspection is possible by analyzing the matching results. Calculation for the registration is accelerated by parallel computing using graphics processing unit (GPU).

마이크로 X-ray CT를 활용한 알루미늄 개방형 폼의 형상 및 압축 거동 분석 (Analysis of 3D Geometry and Compressive Behavior of Aluminum Open Cell Foam Using X-ray Micro CT)

  • 김영일;김지훈;이종국;김대용
    • 소성∙가공
    • /
    • 제20권7호
    • /
    • pp.518-523
    • /
    • 2011
  • The three dimensional geometries of an aluminum open cell foam before and after uniaxial compressive loading were investigated using the X-ray micro CT(computed tomography). Aluminum 6101-T6 open cell foams of 10, 20, 40 ppi (pore per inch) were considered in this work. After the serial sectioning CT images of aluminum foams were obtained from non-destructive X-ray images, the exact 3D structure were reproduced and visualized with commercial image processing program. The relative density ratio was around the 7.0 to 9.0 range, the unit cells showed anisotropic shapes having the different dimensional ratios of 1.1 to 1.3 between the rise and the transverse directions. The yield stress increased with the relative density ratio and the volumetric strain increased proportionally with compressive strain. The plateau stress in the compressive stress-strain curve was caused by the buckling of ligaments.

Identification and Three-Dimensional Characterization of Micropore Networks Developed in Granite using Micro-Focus X-ray CT

  • Choo, Chang-Oh;Takahashi, Manabu;Jeong, Gyo-Cheol
    • 지질공학
    • /
    • 제24권2호
    • /
    • pp.179-189
    • /
    • 2014
  • We analyzed the three-dimensional distribution of micropores and internal structures in both fresh and weathered granite using micro-focus X-ray computed tomography (micro-CT). Results show that the pore radius in fresh granite is mostly in the range of $17-50{\mu}m$, the throat radius is in the range of $5-25{\mu}m$, and the coordination number (CN) of pores is less than 10. In contrast, the pore radius in weathered granite is mostly in the range of $20-80{\mu}m$, the throat radius is in the range of $8-30{\mu}m$, and the CN is less than 12. In general, a positive linear relationship exists between pore radius and CN. In addition, both the size and the density of pores increase with an increasing degree of rock weathering. The size of the throats that connect the pores also increases with an increasing degree of weathering, which induces fracture propagation in rocks. Micro-CT is a powerful and versatile approach for investigating the three-dimensional distributions of pores and fracture structures in rocks, and for quantitatively assessing the degree of pore connectivity.

Comparison of micro-computerized tomography and cone-beam computerized tomography in the detection of accessory canals in primary molars

  • Acar, Buket;Kamburoglu, Kivanc;Tatar, Ilkan;Arikan, Volkan;Celik, Hakan Hamdi;Yuksel, Selcen;Ozen, Tuncer
    • Imaging Science in Dentistry
    • /
    • 제45권4호
    • /
    • pp.205-211
    • /
    • 2015
  • Purpose: This study was performed to compare the accuracy of micro-computed tomography (CT) and cone-beam computed tomography (CBCT) in detecting accessory canals in primary molars. Materials and Methods: Forty-one extracted human primary first and second molars were embedded in wax blocks and scanned using micro-CT and CBCT. After the images were taken, the samples were processed using a clearing technique and examined under a stereomicroscope in order to establish the gold standard for this study. The specimens were classified into three groups: maxillary molars, mandibular molars with three canals, and mandibular molars with four canals. Differences between the gold standard and the observations made using the imaging methods were calculated using Spearman's rho correlation coefficient test. Results: The presence of accessory canals in micro-CT images of maxillary and mandibular root canals showed a statistically significant correlation with the stereomicroscopic images used as a gold standard. No statistically significant correlation was found between the CBCT findings and the stereomicroscopic images. Conclusion: Although micro-CT is not suitable for clinical use, it provides more detailed information about minor anatomical structures. However, CBCT is convenient for clinical use but may not be capable of adequately analyzing the internal anatomy of primary teeth.

Molar-Incisor Malformation 환자의 유치열 내 전반적인 치수석 관찰의 증례 보고 (Generalized Pulp Stones of Primary Dentition in a Patient with Molar-Incisor Malformation : A Case Report)

  • 이동연;신지선
    • 대한소아치과학회지
    • /
    • 제47권3호
    • /
    • pp.337-343
    • /
    • 2020
  • Molar-incisor malformation(MIM)은 최근 발견된 새로운 형태의 root anomaly로 제1대구치 및 제2유구치의 짧거나 미약한 치근 발달과 협착된 치수강, 그리고 cemento-enamel junction 높이에 석회화물질의 존재를 특징으로 한다. 이 증례는 MIM 이환 환자에서 유치열 전반에 걸쳐 치수강 내를 거의 가득 채우고 있는 free pulp stone을 방사선학적으로 확인할 수 있었다. 발치된 환자의 하악 제1대구치와 상악 제2유구치를 대상으로 micro-computed tomography(micro-CT) 촬영 및 scanning electron microscope-energy dispersive X-ray spectrometer 분석을 시행하였다. Micro-CT 영상을 통해, 하악 제1대구치의 치관 외부로 연결된 부근관의 존재가 확인되었다. 이것은 MIM 이환 치아에서 근관치료의 불량한 예후의 원인이 될 수 있을 것으로 사료된다.