• Title/Summary/Keyword: X-ray methods

Search Result 2,159, Processing Time 0.039 seconds

A Volume Reconstruction Algorithm and a Coordinate Calibration of an X-ray Three Dimensional Imaging System

  • Roh, Young-Jun;Cho, Hyung-Suck;Jeon, Hyoung-Jo;Kim, Hyeong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.63.3-63
    • /
    • 2001
  • Inspection and shape measurement of three-dimensional objects are widely needed in industries for quality monitoring and control. In this paper, we propose a three dimensional volume reconstruction method, which is an iterative method and as uniform and simulated algebraic reconstruction technique (USART). In this method, two or more x-ray images projected from different views are needed, and also the geometry of the imaging system need to be a priori identified well. That is to say, the relative locations between the x-ray source, imaging plane and the object should be determined exactly by calibration. To achieve this, we propose a series of coordinate calibration methods of the x-ray imaging system using grid pattern images. Some experimental results of these calibrations is presented and discussed in detail ...

  • PDF

Three Dimensional Volume Reconstruction of Polyhedral Objects Using X-ray Stereo Images

  • Roh, Young-Jun;Kim, Byung-Man;Cho, Hyung-Suck
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.28.2-28
    • /
    • 2001
  • Three dimensional shape measurement techniques are widely needed in industries for product quality monitoring and control. X-ray imaging method is a promising technology to achieve three-dimensional Information, both the surface and inner structure of an object, since it can overcome the limitations of conventional visual or optical methods such as an occlusion problem or surface reflection properties. In this paper, we propose three dimensional volume reconstruction method based on x-ray stereo imaging technology. Here, the stereo images of an object from two different views are taken by changing the object pose rather than moving imaging plane as in conventional stereo vision method. We propose a series of image processing techniques to extract the features efficiently from x-ray images, where the occluded features in case of normal camera vision could be found ...

  • PDF

Alkali-Swollen Structures of Native Cellulose Fibers by X-ray Diffraction Methods (X선회절법(線回折法)에 의한 천연 셀룰로오스 섬유의 알칼리 팽윤구조(膨潤構造))

  • Kim, Nam-Hun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.38-45
    • /
    • 1992
  • Fine and alkali-swollen structures of native cellulose fibers were investigated by x-ray diffraction methods. The results of fine structures are shown in Table 1. In meridional x-ray diffractograms, the relative intensity ratio R of (002) to (004) for cellulose I was ca. 0.05 and for regenerated cellulose it was ca. 0.45. It was considered that the transformation from cellulose I to cellulose II resulted from the packing or conformational change of cellulose chain. Finally. although cellulose I was not detected in the alkali-swollen celluloses treated for 1 hr to 24 hrs, washing and drying them resulted in the generation of considerable amounts of cellulose I and the amount decreased with increasing alkali duration.

  • PDF

Detection of Pulmonary Nodules' Shadow on Chest X-ray Image (흉부 X선 영상에 있어서 폐 종류 음영의 검출)

  • Kim, Eung-Kyeu;Lee, Do-Kyeom
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.293-294
    • /
    • 2007
  • The purpose of this study is prove the effectiveness of an energy subtraction image for the detection of pulmonary nodules and the effectiveness of multi-resolutional filter on an energy subtraction image to detect pulmonary nodules. Also we study influential factors to the accuracy of detection of pulmonary nodules from viewpoints of types of images, types of digital filters and types of evaluation methods. As one type of images, we select an energy subtraction image, which removes bones such as ribs from the conventional X-ray image by utilizing the difference of X-ray absorption ratios at different energy between bones and soft tissue. Here we select two evaluation methods and make clear the effectiveness of multi-resolutional filter on an energy subtraction image.

  • PDF

X-Ray Triple Crystal Diffraction Spectrometer and Its Applications (X-Ray Triple Crystal Diffraction Spectrometer의 제작과 그 응용)

  • Park Young-Han;Yeom Byo-Young;Yoon Hyng-Guen;Min Suk-ki;Park Young Joo
    • Korean Journal of Crystallography
    • /
    • v.8 no.1
    • /
    • pp.20-25
    • /
    • 1997
  • Two experimental methods have been developed for high resolution measurement of x-ray scattering. The methods used were (1) an x-ray double crystal diffraction (DCD) spectrometer set-up and (2) an x-ray triple crystal diffraction (TCD) spectrometer set-up. With the DCD arrangement of Si(511)-sample(hkl), rocking curves have been plotted for Si (333), Si(004) and GaAs(004). Also, with the TCD arrangement of Si(111)-Si(111)-Si(511)-sample(hkl) including monolithic monocro-collimator and $K_{\alpha1}$ selector, rocking curves have been plotted for Si(333), Si(004) and GaAs(004). The results of FWHM by DCD and TCD set-up have been compared each other and discussed. The reflection topographs (004) and (115) in an $In_{0.037}Ga_{0.0963}As/GaAs$ sample have been obtained by DCD set-up.

  • PDF

Relative quantitative evaluation of mechanical damage layer by X-ray diffuse scattering in silicon wafer surface (실리콘 웨이퍼 표면에서 X-선 산만산란에 의한 기계적 손상층의 상대 정량 평가)

  • 최치영;조상희
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.8 no.4
    • /
    • pp.581-586
    • /
    • 1998
  • We investigated the effect of mechanical back side damage in Czochralski grown silicon wafer. The intensity of mechanical damage was evaluated by minority carrier recombination lifetime by laser excitation/microwave reflection photoconductivity decay method, degree of X-ray diffuse scattering, X-ray section topography, and wet oxidation/preferential etching methods. The data indicate that the higher the mechanical damage intensity, the lower the minority carrier lifetime, and the magnitude of diffuse scattering and X-ray excess intensity increased proportionally, and it was at Grade 1:Grade 2:Grade 3=1:7:18.4 that the normalized relative quantization ratio of excess intensity in damaged wafer was calculated, which are normalized to the excess intensity from sample Grade 1.

  • PDF

Shape Reconstruction of Solder Joints on PCB using Iterative Reconstruction Technique (반복복원 기법을 이용한 전자회로기판의 납땜부 형상 복원)

  • 조영빈;권대갑
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.3
    • /
    • pp.353-362
    • /
    • 1999
  • This paper presents a shape reconstruction method for automatic inspection of the solder joints on PCBs using X-ray. Shape reconstruction from X-ray radiographic image has been very important since X-ray equipment was used for improving the reliability of inspection result. For this purpose there have been lots of previous works using tomography, which reconstructs the correct shape, laminography or tomosynthesis, which are very fast algorithm. Latter two methods show outstanding performance in cross-sectional image reconstruction of lead type component, but they are also known to show some fatal limitations to some kinds of components such as BGA, because of shadow effect. Although conventional tomography does not have any shadow effect, the shape of PCB prohibits it from being applied to shape reconstruction of solder joints on PCB. This paper shows that tomography using Iterative Reconstruction Technique(IRT) can be applied to this difficult problem without any limitations. This makes conventional radiographic instrument used for shape reconstruction without shadow effect. This means that the new method makes cost down and shadow-free shape reconstruction. To verify the effectiveness of IRT, we develop three dimensional model of BGA solder ball, make projection model to obtain X-ray projection data. and perform a simulation study of shape reconstruction. To compare the performance of IRT with that of conventional laminography or tomosynthesis, reconstruction data are reorganized and error analysis between the original model are also performed.

  • PDF

The Performance Test of Anti-scattering X-ray Grid with Inclined Shielding Material by MCNP Code Simulation

  • Bae, Jun Woo;Kim, Hee Reyoung
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.111-115
    • /
    • 2016
  • Background: The scattered photons cause reduction of the contrast of radiographic image and it results in the degradation of the quality of the image. In order to acquire better quality image, an anti-scattering x-ray gird should be equipped in radiography system. Materials and Methods: The X-ray anti-scattering grid of the inclined type based on the hybrid concept for that of parallel and focused type was tested by MCNP code. The MCNPX 2.7.0 was used for the simulation based test. The geometry for the test was based on the IEC 60627 which was an international standard for diagnostic X-ray imaging equipment-Characteristics of general purpose and mammographic anti-scatter grids. Results and Discussion: The performance of grids with four inclined shielding material types was compared with that of the parallel type. The grid with completely tapered type the best performance where there were little performance difference according to the degree of inclination. Conclusion: It was shown that the grid of inclined type had better performance than that of parallel one.

The Comparative analysis of X-ray film on Lumbar Scoliosis and HNP by Barge Method (Barge 방식에 의한 요추부 척추측만증과 추간판 탈출증의 X-ray 비교분석)

  • Kim, Gyu-Sub
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.6 no.1
    • /
    • pp.53-61
    • /
    • 2011
  • Objective: The purpose of this study is to evaluate the disc block subluxation for lumbar scoliosis and herniation of nucleus pulpous (HNP). Methods: We used AP & Lateral view X-ray for patients. And we measured of disc wedge angle, vertebral body rotation to evaluate the typical and atypical disc block subluxation. Results: On the analysis of the lateral view X-ray, 4th lumbar intervertebral disc angle (I.V.D angle) showed $4^{\circ}$, $5^{\circ}$, $3^{\circ}$, $0^{\circ}$ in the cases. On the 4th lumbar analysis of the AP view X-ray, lumbar scoliosis showed right disc wedge angle was $11^{\circ}$ (case 1), $17^{\circ}$ (case 2) and left vertebral body rotation was 13mm, 6mm. Lumbar HNP showed left disc wedge angle was $5^{\circ}$ (case 3), $4^{\circ}$ (case 4) and left vertebral body rotation was 2mm, 4mm. Conclusions: Disc block subluxation has been in lumbar scoliosis, but not been in lumbar HNP.

  • PDF

DYNAMICAL EVOLUTION OF SUPERNOVA REMNANTS BREAKING THROUGH MOLECULAR CLOUDS

  • Cho, Wankee;Kim, Jongsoo;Koo, Bon-Chul
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.2
    • /
    • pp.139-154
    • /
    • 2015
  • We carry out three-dimensional hydrodynamic simulations of the supernova remnants (SNRs) produced inside molecular clouds (MCs) near their surface using the HLL code (Harten et al. 1983). We explore the dynamical evolution and the X-ray morphology of SNRs after breaking through the MC surface for ranges of the explosion depths below the surface and the density ratios of the clouds to the intercloud media (ICM). We find that if an SNR breaks out through an MC surface in its Sedov stage, the outermost dense shell of the remnant is divided into several layers. The divided layers are subject to the Rayleigh-Taylor instability and fragmented. On the other hand, if an SNR breaks through an MC after the remnant enters the snowplow phase, the radiative shell is not divided to layers. We also compare the predictions of previous analytic solutions for the expansion of SNRs in stratified media with our onedimensional simulations. Moreover, we produce synthetic X-ray surface brightness in order to research the center-bright X-ray morphology shown in thermal composite SNRs. In the late stages, a breakout SNR shows the center-bright X-ray morphology inside an MC in our results. We apply our model to the observational results of the X-ray morphology of the thermal composite SNR 3C 391.