• Title/Summary/Keyword: X-ray methods

Search Result 2,188, Processing Time 0.029 seconds

Development of daily solar flare peak flux forecast models for strong flares

  • Shin, Seulki;Lee, Jin-Yi;Chu, Hyoung-Seok;Moon, Yong-Jae;Park, JongYeob
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.64.3-64.3
    • /
    • 2015
  • We have developed a set of daily solar flare peak flux forecast models for strong flares using multiple linear regression and artificial neural network methods. We consider input parameters as solar activity data from January 1996 to December 2013 such as sunspot area, X-ray flare peak flux and weighted total flux of previous day, and mean flare rates of McIntosh sunspot group (Zpc) and Mount Wilson magnetic classification. For a training data set, we use the same number of 61 events for each C-, M-, and X-class from Jan. 1996 to Dec. 2004, while other previous models use all flares. For a testing data set, we use all flares from Jan. 2005 to Nov. 2013. The best three parameters related to the observed flare peak flux are weighted total flare flux of previous day (r = 0.51), X-ray flare peak flux (r = 0.48), and Mount Wilson magnetic classification (r = 0.47). A comparison between our neural network models and the previous models based on Heidke Skill Score (HSS) shows that our model for X-class flare is much better than the models and that for M-class flares is similar to them. Since all input parameters for our models are easily available, the models can be operated steadily and automatically in near-real time for space weather service.

  • PDF

Studies on X-Ray Fluorescence Analysis of Sulfide Ores by Solution Technique (II). Analysis of Iron, Copper and Cobalt (용액법을 이용한 황화광석의 X-선 형광분석에 관한 연구 (제2보). 철, 구리 및 코발트의 분석)

  • Young-Sang Kim;Kee-Chae Park
    • Journal of the Korean Chemical Society
    • /
    • v.26 no.5
    • /
    • pp.320-325
    • /
    • 1982
  • Utilyzing the solution prepared for the sulfur determination, the amounts of iron, copper and cobalt in the sulfide ore were determined by X-ray fluorescence spectrometry. The samples were dissolved with the mixed solutions of ,$Br_2\;and\;HNO_3$ and a major constituent of $SiO_2$was repelled from the solution by HF treatment several times. The analytical results agreed with the data obtained by conventional methods within ${\pm}$1.5% for Fe of the range of 20 to 50%, ${\pm}$1.0% for Cu of 10 to 15%, and ${\pm}$0.4% for Co of 1 to 5%. The present method was tolerably found to be reproducible.

  • PDF

A Study on Gas Storage Medium by Using X-ray Diffraction (X-선 회절을 이용한 기체 저장제의 연구)

  • Park, Jong-Sam;Lee, Joon-Il
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.147-155
    • /
    • 2006
  • The crystal structures of fully dehydrated $K_3Na_8H-A(R_1=0.0478,\;R_2=0.0458\;and\;a=12.257(1){\AA})$ have been studied by single-crystal x-ray diffraction methods in the cubic space group. Pm3m in order to understand the structure of the zeolite as a gas storage medium and the mechanisms based on the encapsulation and decapsulation processes of gas molecules. In the crystal structures of dehydrated $K_3Na_8H-A$, three $K^+$ ions per unit cell are located on the 8-oxygen ring(0.0, 0.4531, 0.4531) and eight $Na^+$ ions per unit cell are located near the centers of 6-oxygen rings. Each $K^+$ ions on the 8-ring is $2.87(2){\AA}$ and $2.79(1){\AA}$ away from two kinds of framework oxygen atoms. These values are more realistic than previously known values in $K_{12}Na-A$. The exact positions of $K^+$ ions are ca. $0.8{\AA}$ away from the centers of the 8-rings which are previously reported as the preferred location of $K^+$ ions. Because the zeolites frameworks are stabilized as the results, more effective controls of gas molecules at encapsulation, decapsulation, and storage are achieved. Additionally, the available storage volumes are also maximized and more volume of gases can be stored in the materials. Therefore, oxygen storage bottles in hospital can be minimized and portable oxygen bottles for patients in emergency can be developed by using the materials.

  • PDF

Usefulness of Vibration Response Imaging (VRI) for Pneumonia Patients (폐렴환자에서 진동 공명 영상 검사(VRI)의 유용성)

  • Park, Eu-Gene;Park, Jung-Hee;Hong, Mi-Jin;Kim, Won-Dong;Lee, Kye-Young;Kim, Sun-Jong;Kim, Hee-Joung;Ha, Kyoung-Won;Chon, Gyu-Rak;Kim, Hyun-Ai;Yoo, Kwang-Ha
    • Tuberculosis and Respiratory Diseases
    • /
    • v.71 no.1
    • /
    • pp.30-36
    • /
    • 2011
  • Background: Pneumonia is commonly seen in outpatient clinics. it is widely known as the most common cause of death from infectious disease. Pneumonia has been diagnosed by its typical symptoms, chest X-ray and blood tests. However, both chest X-rays and blood tests have limitations in diagnosis. Thus primary care clinicians usually have been constrained due to a lack of adequate diagnostic tools. Vibration response imaging (VRI) is a newly emerging diagnostic modality, and its procedure is non-invasive, radiation-free, and easy to handle. This study was designed to evaluate the diagnostic usefulness of the VRI test among pneumonia patients and to consider its correlation with other conventional tests such as Chest X-ray, laboratory tests and clinical symptoms. Methods: VRI was performed in 46 patients diagnosed with pneumonia in Konkuk University Medical Center. VRI was assessed in a private and quiet room twice: before and after the treatment. Sensors for VRI were placed on a patient's back at regular intervals; they detected pulmonary vibration energy produced when respiration occurred and presented as specific images. Any modifications either in chest X-ray, C-reactive protein (CRP), white blood cell count (WBC) or body temperature were compared with changes in VRI image during a given time course. Results: VRI, chest X-ray and CRP scores were significantly improved after treatment. Correlation between VRI and other tests was not clearly indicated among all patients. But relatively severe pneumonia patients showed correlations between VRI and chest X-ray, as well as between VRI and CRP. Conclusion: This study demonstrates that VRI can be safely applied to patients with pneumonia.

Theory of X-ray microcomputed tomography in dental research: application for the caries research (치과 분야 연구에서 미세전산화 단층촬영술의 이론: 치아우식증에 대한 적용)

  • Park, Young-Seok;Bae, Kwang-Hak;Chang, Ju-Hea;Shon, Won-Jun
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.2
    • /
    • pp.98-107
    • /
    • 2011
  • Caries remains prevalent throughout modern society and is the main disease in the field of dentistry. Although studies of this disease have used diverse methodology, recently, X-ray microtomography has gained popularity as a non-destructive, 3-dimensional (3D) analytical technique, and has several advantages over the conventional methods. According to X-ray source, it is classified as monochromatic or polychromatic with the latter being more widely used due to the high cost of the monochromatic source despite some advantages. The determination of mineral density profiles based on changes in X-ray attenuation is the principle of this method and calibration and image processing procedures are needed for the better image and reproducible measurements. Using this tool, 3D reconstruction is also possible and it enables to visualize the internal structures of dental caries. With the advances in the computer technology, more diverse applications are being studied, such automated caries assessment algorithms.

A Study on the Condition of Single Crystal Neutron Experiment

  • Lee, Yun-Peel
    • Nuclear Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.31-34
    • /
    • 1972
  • The reciprocal space method of increasing the signal to background ratio in X-ray diffraction work with single crystal is extended to the case of equatorial neutron diffraction works. The formulae of optimum width of the detectors with If e various experimental methods are derived.

  • PDF

Electrochemical Oxidation of Silver (I) Salt (Ag(I) 염의 전해산화)

  • Duk Mook Kim
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.2
    • /
    • pp.158-163
    • /
    • 1985
  • The anodic oxidations of the Silver(I) / Silver(II) / Silver(III) system have been studied in aq. 2M $AgNO_3$ solution with Platinum and Carbon electrodes. It has been found that $Ag_7O_8NO_3$ can be produced at relatively higher current density. Deposited black Oxy-salt were analyzed with several methods such as oxidizing power, X-ray powder diffraction patterns, thermal analysis, and reduction curves. It decomposed to AgO upon being suspended in boiling water. AgO compound obtained from $Ag_7O_8NO_3$ were purer and denser than Alfa-product AgO.

  • PDF

Asbestos Analysis of China Sepiolite by Transmission Electron Microscopy (중국산 해포석 내 석면 함유 유무 분석)

  • Song, Se Wook;Chung, Yong Hyun;Han, Jeong Hee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.3
    • /
    • pp.205-211
    • /
    • 2013
  • Objectives: 21 sepiolite substances produced in China were investigated for the presence of asbestos in their materials. Materials and methods: In order to identify asbestos in sepiolite substances, test materials were analyzed using a transmission electron microscope equipped with energy dispersive X-ray spectrometer (TEM-EDS) for confirming their shape and components (atomic %). Results: Five of 21 sepiolte substances were asbestos-containing materials. Two chrysotile containing sepiolite proved to be asbestoscontaining materials, as did two chrysotile mixed with tremolite containing sepiolite. 16 sepiolite substances did not contain asbestos materials. Conclusions: When importing sepiolite substances, they must be analyzed to determine if there is asbestos in their materials.

Defect Measurement of Graphites for High Temperature Application by AE Technique (AE 계측에 의한 고온용 흑연재료의 경함측정에 관한 연구)

  • Choe, Man-Yong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.9 no.2
    • /
    • pp.122-127
    • /
    • 1992
  • In this study, we investigated defects of graphite by three NDT methods which are ultrasonic testing at 5 MHz, micro-forused X-ray testing and AE testing. As the detection of AE signals generated from graphite tensile specimens, we calculated location of AE sources and compared them with UT and X-ray test results in detecting defects of several specimens, Acoustic emission testing could be applied to some graphites which have fine grains of a few tens of micrometer, but it was difficult to those in lager grain of few fo milimeter. Also, we could understand what kind of defects has affected on tensile fracture of graphite.

  • PDF

A qualitative analysis of bonding between electroformed surface and veneering ceramics

  • Kwon, Ho-Beom;Yim, Soon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.3
    • /
    • pp.328-335
    • /
    • 2000
  • Statement of the problem. Recently an innovative method of fabricating indirect restorations by gold electroforming has been developed. But the bond quality and strength of the gold coping to the porcelain is uncertain. Purpose of study. The purpose of this study is to analyze and evaluate the electroformed gold surface for mechanical bonding between the gold and the ceramic veneering. Methods/material. Electroformed disks were made using electroforming technique. And the surface of the electroformed coping was analyzed after sandblasting, heat-treatment, bonding agent application, opaque porcelain firing with scanning electron microscopy and energy dispersive x-ray analysis. Results. In the analysis with SEM, Sandblasting made the sharp edges and undercuts on the electroformed surface, and after bonding agent application, net-like structure were created on the electroformed surface. In the energy dispersive x-ray analysis it is confirmed that electroformed surface contains some impurities. Conclusion. With the use of sandblasting and bonding agent, electroformed surface seems to be enough to bond with veneering porcelain.

  • PDF