• Title/Summary/Keyword: X-ray methods

Search Result 2,159, Processing Time 0.037 seconds

Correlation Analysis about Subluxation Diagnosis Using Lumbar X-ray and Body Shape Analysis System (요추 단순 방사선 검사와 체형분석 기기를 통한 변위진단과 상관관계 분석)

  • Ji-Won Lee;Min-Su Ju;Youn-Seok Ko;Yi-Gun Lim;Hyeon-Ho Hwang
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.33 no.4
    • /
    • pp.195-201
    • /
    • 2023
  • Objectives This study analyzed the correlation between lumbar spine and pelvic body parameters measured using body shape analysis system and X-ray view. Methods Body shape analysis system and X-ray view were performed for 100 patients to diagnose subluxation using body parameters such as pelvic obliquity angle, anterior superior iliac spine to posterior superior iliac spine angle (ASIS-PSIS angle), lumbar lateral flexion angle. The correlation analysis using body parameters obtained through the body shape analysis system and X-ray view was performed by measuring the Pearson correlation coefficient, a parameter test. Results Significant correlations were observed between the values for pelvic obliquity angle, ASIS-PSIS angle, lumbar lateral flexion angle measured by X-ray view and body shape analysis system. The most significant correlation was observed in the value of pelvic obliquity angle. Conclusions Body parameters and posture analysis measured by the body shape analysis system can be used in place of X-ray view. Additional research and samples are still necessary.

Determination of Trace Elements in Atmospheric Dust by X-Ray Fluorescence Spectrometry(II) : X-ray Fluorescence Spectrometric Determination of Light Elements (형광 X선에 의한 대기분진중의 미량성분의 측정(II): 대기부유분진 중 경원소의 X-선 형광분석)

  • 이용근;박현미;이동수;이보경
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.247-254
    • /
    • 1993
  • A simple and direct method is developed for the determination of light Elements in atmospheric particulates by X-ray fluorescence spectrometry. Calibration standards for the light elements such as Al, Mg, K, Ca, etc are prepared by filtering real atmospheric particulates over variable time and subsequently standardizing them by Inductively Coupled Plasma-Mass Spectrometry(ICP-MS) or Atomic Absorption Spectrophotometry(AAS) analysis. The validity of this calibration method is tested by analyzing more than 100 aerosol samples, collected at urban(Seoul) and rural(Padori) sites over a two year period with this method and then comparing them with those by other accuracy proven methods such as AAS or ICP-MS: for all metals tested the results showed reasonably good agreements (R $\geq$ 0.95).

  • PDF

X-RAY SOURCES WITH NO COUNTERPARTS IN OTHER WAVELENGTH BANDS

  • Kim, Chulhee;Moon, Byung-Kwon;Park, Hong Soo
    • Journal of The Korean Astronomical Society
    • /
    • v.47 no.5
    • /
    • pp.163-166
    • /
    • 2014
  • In order to identify peculiar X-ray sources, we select 442 sources with no counterparts in other wavelength bands (as of the year 1999) from the ROSAT All-Sky Survey Bright Source Catalog. We cross-correlate this initial list with the NASA/IPAC Extragalactic Database, the USNO and WISE catalogs, and the HEASARC XRAY Master Catalog. Eventually, we are left with four unidentified sources with no counterparts in other wavelength bands. We present these four sources and their X-ray properties in this paper.

Comparison of X-ray VCUG with RI VCUG for Diagnosing VUR in Children (소아의 방광 요관 역류 진단시 X-ray 배뇨성 방광 요도 조영술(X-ray VCUG)과 방사성 동위원소 배뇨성 방광 요도 조영술(RI VCUG)의 비교)

  • Hong Hyun-Soook;Choi Deuk-Lin;Kim Eun-Mi;Kim Sung-Jun
    • Childhood Kidney Diseases
    • /
    • v.3 no.2
    • /
    • pp.187-195
    • /
    • 1999
  • Purpose : VUR is state where urine regurge from bladder to ureter and kidney. It is shown in about 1/3 of urinary tract infection patients and it is classified as grade I to V. We compared results from RI VCUG(Radiisotope voiding cystourethrography) and X-ray VCUG which used in diagnosing VUR in children, to evaluate which is better in diagnosing VUR in children. Methods : 41 Patients(19 males, 21 females), who visited Pediatric department, Soonchunhyang university Hospital from peroid of 1991. January to 1998. July for recurrent urinary tract infection or abnormalities in ultrasonogams, were enrolled in the study. The age ranged from 9 months to 17 years and mean age was 5 1/2 years. Both RI VCUG and X-ray VCUG were done and follow-up test of urine culture, renal ultrasonogram and RI VCUG were done every month, every 3 month and every 6 month, respectively to observe the disappearance of VUR and evaluated the prognosis. Results : 24 patients had taken RI VCUG and 17(70.1%) patients showed positive result. 22 patients had taken X-ray VCUG and 9(40.1%) patients showed findings of VUR. 17 patients had taken both tests and 14 patients showed positive result in RI VCUG and 6 of these patients also showed reflux in X-ray VCUG. 3 patients who showed negative in RI VCUG, showed negative also in X-ray VCUG. For prognosis, resolution and scar formation was shown in 8 patients each. Persistent VUR was shown in 6 patients and 2 of these patients VUR was corrected by operation, 1 patient showed decreased renal function, and 1 patient was not follwed up. 8 of 9 patients who showed findings of VUR on DMSA scan formed a scar and 8 patients who showed no findings of VUR didn't form a scar. Urine culture was positive in 17 of 19 patients with VUR. Positive rate in urine culture was higher than that of patients with no VUR who showed positivity in 15 of 21 patients for urine culture. E. coli was most common organism and the period free of UTI was 14 months in VUR patients and it was shorter compared to patients without VUR which was 26 months. Conclusion : In diagnosing VUR in children, the positive rate was higher in RI VCUG than X-ray VCUG. Therefore, in early diagnosis when VUR is suspicious but not shown in X-ray VCUG, RI VCUG should be done and it will help to make accurate diagnosis.

  • PDF

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

An Automatic Algorithm for Vessel Segmentation in X-Ray Angiogram using Random Forest (랜덤 포레스트를 이용한 X-선 혈관조영영상에서의 혈관 자동 영역화 알고리즘)

  • Jung, Sunghee;Lee, Soochahn;Shim, Hackjoon;Jung, Ho Yub;Heo, Yong Seok;Chang, Hyuk-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.4
    • /
    • pp.79-85
    • /
    • 2015
  • The purpose of this study is to develop an automatic algorithm for vessel segmentation in X-Ray angiogram using Random Forest (RF). The proposed algorithm is composed of the following steps: First, the multiscale hessian-based filtering is performed in order to enhance the vessel structure. Second, eigenvalues and eigenvectors of hessian matrix are used to learn the RF classifier as feature vectors. Finally, we can get the result through the trained RF. We evaluated the similarity between the result of proposed algorithm and the manual segmentation using 349 frames, and compared with the results of the following two methods: Frangi et al. and Krissian et al. According to the experimental results, the proposed algorithm showed high similarity compared to other two methods.

PREDICTION OF DAILY MAXIMUM X-RAY FLUX USING MULTILINEAR REGRESSION AND AUTOREGRESSIVE TIME-SERIES METHODS

  • Lee, J.Y.;Moon, Y.J.;Kim, K.S.;Park, Y.D.;Fletcher, A.B.
    • Journal of The Korean Astronomical Society
    • /
    • v.40 no.4
    • /
    • pp.99-106
    • /
    • 2007
  • Statistical analyses were performed to investigate the relative success and accuracy of daily maximum X-ray flux (MXF) predictions, using both multilinear regression and autoregressive time-series prediction methods. As input data for this work, we used 14 solar activity parameters recorded over the prior 2 year period (1989-1990) during the solar maximum of cycle 22. We applied the multilinear regression method to the following three groups: all 14 variables (G1), the 2 so-called 'cause' variables (sunspot complexity and sunspot group area) showing the highest correlations with MXF (G2), and the 2 'effect' variables (previous day MXF and the number of flares stronger than C4 class) showing the highest correlations with MXF (G3). For the advanced three days forecast, we applied the autoregressive timeseries method to the MXF data (GT). We compared the statistical results of these groups for 1991 data, using several statistical measures obtained from a $2{\times}2$ contingency table for forecasted versus observed events. As a result, we found that the statistical results of G1 and G3 are nearly the same each other and the 'effect' variables (G3) are more reliable predictors than the 'cause' variables. It is also found that while the statistical results of GT are a little worse than those of G1 for relatively weak flares, they are comparable to each other for strong flares. In general, all statistical measures show good predictions from all groups, provided that the flares are weaker than about M5 class; stronger flares rapidly become difficult to predict well, which is probably due to statistical inaccuracies arising from their rarity. Our statistical results of all flares except for the X-class flares were confirmed by Yates' $X^2$ statistical significance tests, at the 99% confidence level. Based on our model testing, we recommend a practical strategy for solar X-ray flare predictions.

Study of the Production Method of the Framework of Lacquerware Inlaid with Mother-of-pearl Using X-ray Computed Tomography (엑스선 컴퓨터 단층면 조사를 통한 나전연상 백골의 제작기법 연구)

  • Park, Youngman;Yang, Seokjin
    • Conservation Science in Museum
    • /
    • v.24
    • /
    • pp.75-80
    • /
    • 2020
  • X-ray computed tomography (X-ray CT), which is often applied to the investigation of the interior structures of cultural properties, is very useful for studying production methods used in lacquerware that would otherwise be difficult to observe with the naked eye. Lacquerware inlaid with mother-of-pearl is an important subject in the study of traditional Korean craft. However, it can be a challenge to specify the production methods used in the framework of a lacquerware item unless the object has been structurally damaged. Studies of lacquerware inlaid with mother-of-pearl have thus far focused on the techniques of lacquering and of inlaying the mother-of-pearl. Production methods for the framework of lacquerware has received little academic attention. This study conducted X-ray CT on a lacquerware item from the Joseon period to reveal the materials and woodworking techniques used for the framework. The study revealed that softwood was used for the framework, and the post (gidungmok) and apron (soemok) were joined using a three-way miter joint (sambang yeongwi jjaim). Other pieces were joined with nails.

An Efficient Background Modeling and Correction Method for EDXRF Spectra (EDXRF 스펙트럼을 위한 효율적인 배경 모델링과 보정 방법)

  • Park, Dong Sun;Jagadeesan, Sukanya;Jin, Moonyong;Yoon, Sook
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.8
    • /
    • pp.238-244
    • /
    • 2013
  • In energy dispersive X-ray fluorescence analysis, the removal of the continuum on which the X-ray spectrum is superimposed is one of the most important processes, since it has a strong influence on the analysis result. The existing methods which have been used for it usually require tight constraints or prior information on the continuum. In this paper, an efficient background correction method is proposed for Energy Dispersive X-ray fluorescence (EDXRF) spectra. The proposed method has two steps of background modeling and background correction. It is based on the basic concept which differentiates background areas from the peak areas in a spectrum and the SNIP algorithm, one of the popular methods for background removal, is used to enhance the performance. After detecting some points which belong to the background from a spectrum, its background is modeled by a curve fitting method based on them. And then the obtained background model is subtracted from the raw spectrum. The method has been shown to give better results than some of traditional methods, while working under relatively weak constraints or prior information.

The Study of Effectiveness of Wooden Pillow and Comparison Evaluation of diagnosis method on Straightening of Cervical Curvature Patient (교통사고 후 한방병원에 입원한 일자목증후군 환자를 대상으로 한 진단방법의 비교 평가 및 경침사용의 유효성 연구)

  • Lee, Chiho;Jeon, Donghwi;Lee, Eunjung;Oh, Minseok
    • Journal of Haehwa Medicine
    • /
    • v.24 no.2
    • /
    • pp.1-16
    • /
    • 2016
  • Objectives : This study was designed to evaluate various tools including C-spine X-ray for estimating cervical curvature and identify the effect of wooden pillow on patients diagnosed with straightening of cervical curvature. Methods : This study was carried out on 51 subjects who were encountered traffic accident suffering cervical pain and diagnosed with straightening of cervical curvature by X-ray. 51 subjects were divided into wooden pillow(experimental) group and conservative therapy(control) group. Visual analogue scale, neck disability index and lateral pictures were used and compared after treatment. C-spine AP., Lat. X-ray were used on admission day to calculate cervical curvature and scoliosis by various ways. Results : 4 different measurements of cervical curvature didn't show common results. Both wooden pillow(experimental) group and conservative therapy(control) group showed significant improvement in the visual analogue scale(VAS) and neck disability index(NDI) after hospital treatment. Comparison between center line pictured by lateral view and C-spine Lat. pictured by X-ray showed significant difference in cervical curvature. Lateral deviation of cervical vertebra showed lengthened distance between mastoid process and spinous process of C7. Conclusion : As a result of this research, I found out that various tools for calculating cervical lordosis could derive different results and C-spine AP., Lat X-ray could cause artificial cervical lordosis. According to visual analogue scale(VAS) and neck disability index(NDI) wooden pillow was not effective to reduce pain & disability caused by straightening of cervical curvature. Futhermore, correction effect of straightening of cervical curvature and scoliosis by wooden pillow was weak.