X-Ray Diffraction과 X-Ray Fluorescence를 이용한 시멘트 비교 분석 (The analytical application for cement using X-Ray diffraction and X-Ray fluorescence spectrometer)

  • 정지은;장유림;김기욱;허상철;민지숙
    • 분석과학
    • /
    • 제26권5호
    • /
    • pp.340-351
    • /
    • 2013
  • The chemical element and structural characterization of different types of cements and its brick stones are been investigated under forensic aspects using X-ray florescence (XRF) and X-ray diffraction (XRD) spectrometer. The XRF provides rapid compositional data for controlling almost all stages of raw materials, clinker and cement. The decisive advantage of XRD methods is based on the unique character of the diffraction patterns of crystalline substances, the ability to distinguish between elements and their oxides, and the possibility to identify chemical compounds, polymeric forms, and mixed crystals by non-destructive examination. Therefore, combination of these examinations is useful and able to apply for the forensic analysis in comparison of cements and brick stones. There are more study remained to determine the viability of method for forensic analysis of brick stones and the limits of the discrimination that can be achieved.

X-ray상 경추 추체간 간격과 CT상 경추 추간판 탈출증의 상관관계에 대한 고찰 (The Relationship between Cervical Intervertebral Space in X-ray and Herniated Disc in CT)

  • 신우석;정동훈;박원형;차윤엽
    • 한방재활의학과학회지
    • /
    • 제25권4호
    • /
    • pp.75-81
    • /
    • 2015
  • Objectives To investigate the relationship between cervical intervertebral space narrowing in the X-ray and HIVD level of cervical spine in the CT image. Methods We studied 101 subjects who were taken cervical spine X-ray and CT. Intervertebral space were measured at the anterior, middle and posterior portion of each cervical disc in the X-ray. Considering individual difference, intervertebral space was set as value divided by upper width of lower vertebral body. We analyzed statistically adjusted intervertebral space of normal group and herniated disc group using student' t t-test. Results Intervertebral space of cervical spine was narrowed in the herniated disc group. But there was no significant difference at C2~C3. Conclusions We found that narrowing intervertebral space of cervical spine is associated with herniated disc. Further clinical observation is needed.

Image Plate로서의 X선 조사에 대한 Amorphous Selenium Plate 표면 Potential 특성 연구 (The Study for Characteristics between Amorphous Selenium Plate Surface Potential and X-ray Exposure by Image Plate)

  • 최준영;조승열;김명수;임종덕;김덕훈;남상희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.41-44
    • /
    • 1996
  • There are studied for filmness methods due to disadvantage of conventional X-ray system. Have high DQE, high SNR, amorphous selenium was investigated with image plate. In this point, characteristics of all amorphous selenium image plate was investigated to understand the relationship between the amount of the X-ray exposure and the superficial charge potential in this study. Specially, changes in charge at the surface of the amorphous selenium plate with respect to change of X-ray energy(KeV) was investigated. It was found that the surface charge potential at the amorphous selenium inclosed with respect to the increse in X-ray exposure and that the changed surface potential was a semilinearity in 12.5KeV - 22.5KeV range. Therefore, which suggests that these results call be applied to the development of X-ray image plate.

  • PDF

수준관리체계를 통한 핵심 직무역량 향상 방안 - 보안검색요원 판독등급제 중심으로 - (A Plan to Improve Core Job Skills through the Level Management System : Focusing on the X-ray Screening Rating System)

  • 김동민;백정선
    • 품질경영학회지
    • /
    • 제51권4호
    • /
    • pp.677-689
    • /
    • 2023
  • Purpose: The purpose of this study is to design a x-ray screening rating system to improve X-ray screening ability, which is a core job competency of security screener at Incheon International Airport, and to verify its effectiveness through empirical analysis to suggest ways to improve the level management system. Methods: In this study, the effectiveness of the research model was analyzed using T-test tests for effect analysis based on the empirical analysis results derived through the competency evaluation model, the screening rating system. Results: The results of this study are as follows. The average score for regular education before the implementation of the x-ray screening rating system was 94.1 points, but after the implementation of the x-ray screening rating system, the average score for regular education was 95.5 points, an average of 1.4 points increased. In addition, the proportion of those with 95 or more points classified as high scorers also increased significantly from 51.1% to 69.3%. Conclusion: The X-ray screening rating system of security inspectors will systematically manage the level of screening ability, which is a key job competency, and play a strong role in improving competency, while preventing security accidents through early identification and intensive training of level-lowers.

Trial of Computer Simulation of Image Reconstruction from Incomplete Data for New CT with Reduced Exposure

  • Hayakawa, Yoshinori;Furuya, Toshimitsu;Sakakibara, Norifumi
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.382-384
    • /
    • 2002
  • Filtered-Back-Projection technique is used in X-ray CT image reconstruction. This requires X-ray transmission data from all directions. As the transverse cross-section of the body is approximately 50 cm, transmitted X-rays in this direction are strongly attenuated. If X-ray transmission data in this direction is avoided, exposure to the patients seems to be reduced one 20th of usual value. Some alternative method has to be found for clinically sufficient image quality. New methods are under development and tentative results are reported that utilizes the principle of superposition.

  • PDF

어린이 성장판 영상화를 위한 초음파와 X-선 방식의 비교 평가 (Comparison Between Ultrasonic and X-ray Methods for Imaging the Children′s Growth Plate)

  • 김상후;김형준;한은옥;한승무
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권6호
    • /
    • pp.551-556
    • /
    • 2004
  • 본 연구에서는 진단 방법의 정확성이 아직까지 구체적으로 규명되지 않고 있는 어린이의 성장 발육을 체계적이고 과학적으로 측정할 수 있는 방법을 제시하고자 시도하였다. 현재 많이 이용되고 있는 성장 진단 방법은 X-ray 영상을 이용한 각 관절 부위의 성장판의 개폐 분석이다. 그러나 X-ray 방식은 성장 진단에서 요구되는 주기적이고 반복적인 측정을 하지 못함과 동시에 방사선 노출이라는 단점을 가지고 있다. 따라서 인체에 무해한 초음파 영상을 이용한 성장판 개폐 분석 대체 가능성을 평가하기 위해 종골의 초음파 광역 감쇄 영상을 이용한 프로파일 분석 및 성장판 영상 분석 알고리즘을 제시하였다. 본 연구에서는 7세~16세의 어린이 269명에 대해서 X-ray를 이용하여 무릎, 손가락, 종골에서의 성장판 영상을 얻었다. 또한 초음파 방식을 이용하여 종골의 성장판 영상을 얻었다. 각 관절에서의 성장판 개폐 유무 시기는 각 개인별로 측정 방법에 따라 조금의 차이는 있으나 전반적으로 일치하였다. 또한. X-ray방식과 초음파 방식에 의한 성장판 영상을 비교한 결과 상호 높은 연관성을 나타내었다. 이와 같이 성장판을 정확하게 측정하기 위해 도입된 초음파 프로파일 분석 알고리즘은 기존의 X-ray 영상 방식에 의한 성장판의 측정을 대체할 수 있을 것으로 사료된다.

Fundamental Study of nanoDot OSL Dosimeters for Entrance Skin Dose Measurement in Diagnostic X-ray Examinations

  • Okazaki, Tohru;Hayashi, Hiroaki;Takegami, Kazuki;Okino, Hiroki;Kimoto, Natsumi;Maehata, Itsumi;Kobayashi, Ikuo
    • Journal of Radiation Protection and Research
    • /
    • 제41권3호
    • /
    • pp.229-236
    • /
    • 2016
  • Background: In order to manage the patient exposure dose in X-ray diagnosis, it is preferred to evaluate the entrance skin dose; although there are some evaluations about entrance skin dose, a small number of report has been published for direct measurement of patient. We think that a small-type optically stimulated luminescence (OSL) dosimeter, named nanoDot, can achieve a direct measurement. For evaluations, the corrections of angular and energy dependences play an important role. In this study, we aimed to evaluate the angular and the energy dependences of nanoDot. Materials and Methods: We used commercially available X-ray diagnostic equipment. For angular dependence measurement, a relative response of every 15 degrees of nanoDot was measured in 40-140 kV X-ray. And for energy dependence measurement, mono-energetic characteristic X-rays were generated using several materials by irradiating the diagnostic X-rays, and the nanoDot was irradiated by the characteristic X-rays. We evaluated the measured response in an energy range of 8.1-75.5 keV. In addition, we performed Monte-Carlo simulation to compare experimental results. Results and Discussion: The experimental results were in good agreement with those of Monte-Carlo simulation. The angular dependence of nanoDot was almost steady with the response of 0 degrees except for 90 and 270 degrees. Furthermore, we found that difference of the response of nanoDot, where the nanoDot was irradiated from the randomly set directions, was estimated to be at most 5%. On the other hand, the response of nanoDot varies with the energy of incident X-rays; slightly increased to 20 keV and gradually decreased to 80 keV. These results are valuable to perform the precise evaluation of entrance skin dose with nanoDot in X-ray diagnosis. Conclusion: The influence of angular dependence and energy dependence in X-ray diagnosis is not so large, and the nanoDot OSL dosimeter is considered to be suitable dosimeter for direct measurement of entrance surface dose of patient.

반도체 제조 이온주입 공정의 이온 임플란타 장치에서 엑스레이 발생 특성 (Characterization of X-ray Emitted in the Ion Implantation Process of Semiconductor Operations)

  • 박동욱;조경이;김소연;이승희;정은교
    • 한국산업보건학회지
    • /
    • 제33권4호
    • /
    • pp.439-446
    • /
    • 2023
  • Objectives: The aims of this study are to investigate how X-rays are emitted to surrounding parts during the ion implantation process, to analyze these emissions in relation to the properties of the ion implanter equipment, and to estimate the resulting exposure dose. Eight ion implanters equipped with high-voltage electrical systems were selected for this study. Methods: We monitored X-ray emissions at three locations outside of the ion implanters: the accelerator equipped with a high-voltage energy generator, the impurity ion source, and the beam line. We used a Personal Portable Dose Rate and Survey Meter to monitor real-time X-ray levels. The SX-2R probe, an X-ray Features probe designed for use with the RadiagemTM meter, was also utilized to monitor lower ranges of X-ray emissions. The counts per second (CPS) measured by the meter were estimated and then converted to a radiation dose (𝜇Sv/hr) based on a validated calibration graph between CPS and μGy/hr. Results: X-rays from seven ion implanters were consistently detected in high-voltage accelerator gaps, regardless of their proximity. X-rays specifically emanated from three ion implanters situated in the ion box gap and were also found in the beam lines of two ion implanters. The intensity of these X-rays did not show a clear pattern relative to the devices' age and electric properties, and notably, it decreased as the distance from the device increased. Conclusions: In conclusion, every gap, in which three components of the ion implanter devices were divided, was found to be insufficiently shielded against X-ray emissions, even though the exposure levels were not estimated to be higher than the threshold.

X선 고전압장치의 전파 및 배전압 정류방식에 따른 X선 출력 및 선질 비교 (Comparison of Output and Radiation Quality of X-rays according to the Full-Wave Rectification Method and Dual-Voltage Rectification Method of an X-ray Generator)

  • 김태곤;천민우;박용필
    • 한국전기전자재료학회논문지
    • /
    • 제23권7호
    • /
    • pp.534-538
    • /
    • 2010
  • X-ray systems for medical treatment use noninvasive procedures. Being capable of locally inspecting the inside of the body, X-ray systems are routinely used for basic diagnosis. X-ray systems to be used for medical purposes were originally made with a gas filled tube inside an induction coil in the initial stages of development but with this approach it becomes difficult to take a satisfactory picture through thick body sections, non invasively. However continued development made it possible to take non-invasive pictures of breasts, blood vessels and other body parts through thick body sections. Recently, high-voltage X-ray generators of more compact size, increased generation efficiency, and sophisticated output control have become possible. All of these features are made possible by the use of a high-frequency output from an inverter and a fast switching semiconductor device. In this paper, we describe a new X-ray generator operating with a resonant inverter in order to reduce switching loss and high frequency noise. In addition, in order to identify the differences amongst types of rectification, we have compared output and the quality of X-ray pictures obtained with full-wave rectification and dual-voltage rectification methods.

한방병원 입원 시 관례적 흉부 X선 검사의 유용성 (The Utility of Routine Chest X-Ray on Korean Medicine Hospital Admission)

  • 최인우;유호룡
    • 대한한방내과학회지
    • /
    • 제42권4호
    • /
    • pp.622-627
    • /
    • 2021
  • Objective: This study was designed to analyze the utility of routine chest X-ray on Korean medicine hospital admission. Methods: The chest X-ray reports and medical records of 618 patients who were admitted to Daejeon Korean Medicine Hospital from May 1, 2021 to June 30, 2021 were retrospectively reviewed. Results: Of the 618 patients newly hospitalized from May 1, 2021 to June 30, 2021, 560 patients (excluding readmission) were analyzed. The mean age of 560 patients was 53.26±17.20 years. There were 52 patients with abnormal findings, and their mean age was 69.62±15.59 years. Many of these patients had chest symptoms and a history of chest disease. There was no case that showed a significant diagnostic result by chest X-ray examination. Conclusion: The diagnostic usefulness of routine chest X-rays in Korean medicine hospital admission is low. But this does not mean that there is no need to perform routine chest X-rays upon admission.