• 제목/요약/키워드: X-ray methods

검색결과 2,175건 처리시간 0.025초

요추 단순 방사선 검사와 체형분석 기기를 통한 변위진단과 상관관계 분석 (Correlation Analysis about Subluxation Diagnosis Using Lumbar X-ray and Body Shape Analysis System)

  • 이지원;주민수;고연석;임이건;황현호
    • 한방재활의학과학회지
    • /
    • 제33권4호
    • /
    • pp.195-201
    • /
    • 2023
  • Objectives This study analyzed the correlation between lumbar spine and pelvic body parameters measured using body shape analysis system and X-ray view. Methods Body shape analysis system and X-ray view were performed for 100 patients to diagnose subluxation using body parameters such as pelvic obliquity angle, anterior superior iliac spine to posterior superior iliac spine angle (ASIS-PSIS angle), lumbar lateral flexion angle. The correlation analysis using body parameters obtained through the body shape analysis system and X-ray view was performed by measuring the Pearson correlation coefficient, a parameter test. Results Significant correlations were observed between the values for pelvic obliquity angle, ASIS-PSIS angle, lumbar lateral flexion angle measured by X-ray view and body shape analysis system. The most significant correlation was observed in the value of pelvic obliquity angle. Conclusions Body parameters and posture analysis measured by the body shape analysis system can be used in place of X-ray view. Additional research and samples are still necessary.

형광 X선에 의한 대기분진중의 미량성분의 측정(II): 대기부유분진 중 경원소의 X-선 형광분석 (Determination of Trace Elements in Atmospheric Dust by X-Ray Fluorescence Spectrometry(II) : X-ray Fluorescence Spectrometric Determination of Light Elements)

  • 이용근;박현미;이동수;이보경
    • 한국대기환경학회지
    • /
    • 제9권3호
    • /
    • pp.247-254
    • /
    • 1993
  • A simple and direct method is developed for the determination of light Elements in atmospheric particulates by X-ray fluorescence spectrometry. Calibration standards for the light elements such as Al, Mg, K, Ca, etc are prepared by filtering real atmospheric particulates over variable time and subsequently standardizing them by Inductively Coupled Plasma-Mass Spectrometry(ICP-MS) or Atomic Absorption Spectrophotometry(AAS) analysis. The validity of this calibration method is tested by analyzing more than 100 aerosol samples, collected at urban(Seoul) and rural(Padori) sites over a two year period with this method and then comparing them with those by other accuracy proven methods such as AAS or ICP-MS: for all metals tested the results showed reasonably good agreements (R $\geq$ 0.95).

  • PDF

X-RAY SOURCES WITH NO COUNTERPARTS IN OTHER WAVELENGTH BANDS

  • Kim, Chulhee;Moon, Byung-Kwon;Park, Hong Soo
    • 천문학회지
    • /
    • 제47권5호
    • /
    • pp.163-166
    • /
    • 2014
  • In order to identify peculiar X-ray sources, we select 442 sources with no counterparts in other wavelength bands (as of the year 1999) from the ROSAT All-Sky Survey Bright Source Catalog. We cross-correlate this initial list with the NASA/IPAC Extragalactic Database, the USNO and WISE catalogs, and the HEASARC XRAY Master Catalog. Eventually, we are left with four unidentified sources with no counterparts in other wavelength bands. We present these four sources and their X-ray properties in this paper.

소아의 방광 요관 역류 진단시 X-ray 배뇨성 방광 요도 조영술(X-ray VCUG)과 방사성 동위원소 배뇨성 방광 요도 조영술(RI VCUG)의 비교 (Comparison of X-ray VCUG with RI VCUG for Diagnosing VUR in Children)

  • 홍현숙;최득린;김은미;김성준
    • Childhood Kidney Diseases
    • /
    • 제3권2호
    • /
    • pp.187-195
    • /
    • 1999
  • 목적 : 방광요관역류는 방광에서 요관과 신장으로 소변이 역류하는 현상으로 요로감염증의 약 1/3에서 발견되며 정도는 1도에서 5도까지 나눌수 있다. 소아의 방광요관역류의 진단에 있어 사용되는 RI VCUG(Radioisotope voiding cystourethrography(이하 VCUG)) 와 X-ray VCUG의 결과를 비교하여 방광요관역류의 진단에 어느 방법이 더 유용한지 평가하고자 본 연구를 시행하였다. 방법 : 1991년 1월부터 1998년 7월까지 7년 6개월동안 순천향병원 소아과 외래를 방문한 환아중 잦은 요로감염증이나 초음파 검사상 이상소견을 보인 9개월에서 17세까지 평균 5년 6개월의 남아 19명, 여아 21명을 대상으로 대상환아들에게 X-ray VCUG나 RI VCUG 또는 두가지 방법을 동시에 시행하였으며 요검사와 소변 배양검사를 1개월마다, 신장 초음파 검사를 3개월마다, RI VCUG를 6개월마다 추적검사를 시행하여 방광요관역류의 소실여부를 관찰하며 예후를 평가하였다. 결과 : 대상환아중 24명이 RI VCUG를 시행하여 17명이 방광요관역류소견을 보여 70.1%의 양성률을 보였고 22명이 X-ray VCUG를 시행하여 9명이 방광요관역류소견을 보여 40.1%의 양성률을 보였으며 19명이 두가지 검사를 모두 시행하여 15명이 RI VCUG상 양성소견을 보였고 이중 7명이 X-ray VCUG상 양성소견을 보였고 RI VCUG상 음성소견을 보인 4명은 X-ray VCUG 상에서도 음성소견을 보였다. 방광요관역류환아의 예후는 중복신장을 동반한 1례에서는 수술로 교정되었으며 다낭포신을 동반한 1례에서는 역류가 지속되었고 그외 단순한 역류에서는 자연소실과 반혼의 형성이 각각 8명이었으며 역류가 지속된 경우가 5명, 수술로 교정된 경우는 2명, 신기능이 감소된 경우가1명, 추적관찰이 되지않은 경우가 1명이었다. DMSA(2,3-dimercaptosuccinic acid 이하 DMSA) sacn상 방광요관역류환아 9명중 8명이 반흔을 형성하였고 역류가 없던 8명에서는 반흔을 형성하지 않았다. 요배양검사상 방광요관역류환아가 19명중 17명으로 역류가 없던 환아 21명중 15명이 양성소견을 보인것보다 양성률이 높았으며 원인균으로는 대장균이 가장많았고 방광요관역류환아에서 요로감염이 없던 기간은 14개월로 방광요관역류가 없는 환아에서의 26개월보다 짧았다. 결론 : 소아의 방광요관 역류의 진단에 있어 RI VCUG가 X-ray VCUG보다 양성률이 높음을 확인할수 있었다. 그러므로 초기진단시 방광요관 역류가 의심되나 X-ray VCUG로 발견되지 않은 경우에는 RI VCUG를 꼭 시행하는 것이 방광요관역류의 정확한 진단을 하는데 도움이 된다.

  • PDF

치과용 초소형 X-선 튜브의 선량평가 (Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging)

  • 지윤서;김연우;이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제26권3호
    • /
    • pp.160-167
    • /
    • 2015
  • 의료용 x선 촬영 장치에 있어서 환자에게 피폭되는 선량이 가장 중요한 관심사 중의 하나이다. 본 연구팀에서는 전 세계 최초로 입안에 삽입이 가능한 초소형 x-선 영상 장치가 개발되었는데 이러한 영상장치를 임상에서 사용하기 위해서는 피폭 선량의 평가가 필수적이다. 따라서 본 연구에서는 신개념 치과용 영상장치의 선량을 평가하기 위하여 1) 돼지 턱뼈 팬텀을 직접 제작하여 영상의 질을 평가 하였고, 2) 실제 임상에서 사용가능한 촬영 조건을 결정하였으며, 3) 결정된 촬영 조건에서의 선량을 평가 하였다. 한국 식약처에서 제시하는 치근단 촬영에 대한 환자 선량 권고량(DRLs) 기준에 근거하여 새 개발 장비의 입사표면선량(ESD)와 면적선량(DAP) 측정 방법을 고안하고 각각의 선량 값을 측정하였다. 관전압이 45~55 kV, 관전류가 300 mA 까지 사용 가능한 xoft 사의 초소형 x선 튜브를 사용하였다. 사용된 검출기는 active area가 $72{\times}72mm$ 이고 픽셀 사이즈는 $48{\mu}m$ 이다. 제작된 돼지턱뼈 팬텀은 1 frame/sec의 조건하에 영상을 획득 하였으며, 촬영 조건 최적화를 위하여 관전류를 $20{\sim}80{\mu}A$로 변화시키면서 50 frame씩 영상을 획득하였다. 또한, 상용화 치과용 영상시스템(모델명: CS 2100, 제조사: Carestream Dental LLC 및 모델명: EXARO, 제조사: HIOSSEN)을 이용하여 돼지턱뼈 팬텀의 비교영상 평가를 시행하였다. CS 2100는 60 kV, 7 mA (노출시간:0.125 s)로 하였으며, EXARO는 60 kV, 2 mA로 설정하였다. 선량 평가는 광자극 형광 선량계를 이용하여 입사표면선량을 측정하였으며, 팬텀은 PMMA 재질의 제작된 원통형 팬텀을 이용하였다. 선량계는 팬텀 표면상의 조사야 내부에 2개 및 소스와의 5 cm 거리상에 1개를 위치하여 측정하였다. 빔 조사 조건은 51, 101, 141, $196{\mu}As$로 설정하였다. 면적선량은 소스와 검출기간의 거리가 5 cm 위치에 배치하여 측정하였으며, 이 때 촬영조건은, 관전류 41, 99, 144, 207, $276{\mu}As$의 조건하에서 측정하였다. 임상에서 적용 가능한 관전압과 관전류는 X-선 세기 8000~9000인 지점에서의 관전류 값인 0.051 mAs 이다. 상용화 장비와 영상비교를 한 결과, 개발 장비의 조사야가 훨씬 작음에도 불구하고 치아 및 치아 주위 조직의 영상이 더 우수함을 확인하였다. 또한, 영상 최적화 조사조건인 $51{\mu}As$에서 입사표면선량(ESD)은 식약처 및 IAEA의 권고치보다 훨씬 낮은 1.369 mGy 이다. 조사야 내부의 선량 분포는 표준편차 5~10% 내외로 균일성이 우수 하였다. 측정된 면적선량(DAP)은 $82.4mGy*cm^2$으로 상용화 장비보다 조사야가 훨씬 작음에도 불구하고 식약처의 권고치보다 낮은 값을 보였다. 이러한 연구를 통해서 새 개발 장비의 영상의 우수성과 기존 장비 대비 방사선량에 대한 저감 효과를 확인 할 수 있었으며 치과 장비 개발에 있어서 X선 특성 연구에 대한 기술과 노하우를 축적할 수 있었다.

랜덤 포레스트를 이용한 X-선 혈관조영영상에서의 혈관 자동 영역화 알고리즘 (An Automatic Algorithm for Vessel Segmentation in X-Ray Angiogram using Random Forest)

  • 정성희;이수찬;심학준;정호엽;허용석;장혁재
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권4호
    • /
    • pp.79-85
    • /
    • 2015
  • The purpose of this study is to develop an automatic algorithm for vessel segmentation in X-Ray angiogram using Random Forest (RF). The proposed algorithm is composed of the following steps: First, the multiscale hessian-based filtering is performed in order to enhance the vessel structure. Second, eigenvalues and eigenvectors of hessian matrix are used to learn the RF classifier as feature vectors. Finally, we can get the result through the trained RF. We evaluated the similarity between the result of proposed algorithm and the manual segmentation using 349 frames, and compared with the results of the following two methods: Frangi et al. and Krissian et al. According to the experimental results, the proposed algorithm showed high similarity compared to other two methods.

PREDICTION OF DAILY MAXIMUM X-RAY FLUX USING MULTILINEAR REGRESSION AND AUTOREGRESSIVE TIME-SERIES METHODS

  • Lee, J.Y.;Moon, Y.J.;Kim, K.S.;Park, Y.D.;Fletcher, A.B.
    • 천문학회지
    • /
    • 제40권4호
    • /
    • pp.99-106
    • /
    • 2007
  • Statistical analyses were performed to investigate the relative success and accuracy of daily maximum X-ray flux (MXF) predictions, using both multilinear regression and autoregressive time-series prediction methods. As input data for this work, we used 14 solar activity parameters recorded over the prior 2 year period (1989-1990) during the solar maximum of cycle 22. We applied the multilinear regression method to the following three groups: all 14 variables (G1), the 2 so-called 'cause' variables (sunspot complexity and sunspot group area) showing the highest correlations with MXF (G2), and the 2 'effect' variables (previous day MXF and the number of flares stronger than C4 class) showing the highest correlations with MXF (G3). For the advanced three days forecast, we applied the autoregressive timeseries method to the MXF data (GT). We compared the statistical results of these groups for 1991 data, using several statistical measures obtained from a $2{\times}2$ contingency table for forecasted versus observed events. As a result, we found that the statistical results of G1 and G3 are nearly the same each other and the 'effect' variables (G3) are more reliable predictors than the 'cause' variables. It is also found that while the statistical results of GT are a little worse than those of G1 for relatively weak flares, they are comparable to each other for strong flares. In general, all statistical measures show good predictions from all groups, provided that the flares are weaker than about M5 class; stronger flares rapidly become difficult to predict well, which is probably due to statistical inaccuracies arising from their rarity. Our statistical results of all flares except for the X-class flares were confirmed by Yates' $X^2$ statistical significance tests, at the 99% confidence level. Based on our model testing, we recommend a practical strategy for solar X-ray flare predictions.

엑스선 컴퓨터 단층면 조사를 통한 나전연상 백골의 제작기법 연구 (Study of the Production Method of the Framework of Lacquerware Inlaid with Mother-of-pearl Using X-ray Computed Tomography)

  • 박영만;양석진
    • 박물관보존과학
    • /
    • 제24권
    • /
    • pp.75-80
    • /
    • 2020
  • 엑스선 컴퓨터 단층면의 관찰은 문화재의 내부 구조조사를 위한 것으로 육안으로 확인할 수 없는 칠기 공예품의 제작 기법을 조사하는데 매우 유용한 방법이다. 특히 나전칠기는 옻칠과 나전을 사용하여 제작한 한국 전통공예품으로써 매우 중요한 연구 대상품이다. 하지만 특수한 환경에서 구조적으로 손상되어 있지 않는 한 백골의 제작기술을 파악하기에는 어렵다. 그 동안의 나전칠기 공예품의 가치 연구는 옻칠 기법과 나전 공예기술에 관한 연구가 주류가 되고 있지만 나전칠기의 뼈대가 되는 백골의 제작기법에 관한 연구는 이루어지지 않고 있는 실정이다. 본 연구는 조선시대 나전칠기에 대하여 컴퓨터 단층촬영[CT: Computed Tomography]을 실시하여 나전칠기 백골의 재질과 목공기술에 대한 결과를 제공하였다. 목재는 침엽수를 사용하였고 기둥목과 쇠목(기둥과 기둥 사이를 가로질러 대는 목재)의 결합은 삼방연귀짜임 방식을 사용하였으며 그 외의 결구 방법은 못을 사용하였음을 알 수 있었다.

EDXRF 스펙트럼을 위한 효율적인 배경 모델링과 보정 방법 (An Efficient Background Modeling and Correction Method for EDXRF Spectra)

  • 박동선;자가디산 수카니아;진문용;윤숙
    • 전자공학회논문지
    • /
    • 제50권8호
    • /
    • pp.238-244
    • /
    • 2013
  • 에너지 분산형 X-선 형광(EDXRF) 분석에서 X-선 스펙트럼에 존재하는 컨티넘(continuum)의 추정 및 제거는 필수적이다. 이를 위해 일반적으로 사용되는 알고리즘들은 많은 주의가 필요하며 복잡하다. 보통 이 알고리즘들은 제약적이거나 컨티넘의 데이터나 모양에 대한 가설을 필요로 한다. 본 논문에서는 제안된 에너지 분산형 X-선 형광 스펙트럼을 위한 효율적인 배경(background) 보정 방법은 배경 모델링과 배경 보정으로 구성된다. 이 방법은 스펙트럼에서 백그라운드영역과 피크영역을 구분하는 기본 개념을 기반으로 하며 성능향상을 위하여 SNIP알고리즘을 사용한다. 스펙트럼으로부터 배경에 속하는 점들을 획득한 후 이를 기반으로 곡선 근사화를 통해 배경을 모델링한다. 이후 획득된 배경 모델을 원 스펙트럼에서 뺌으로써 배경이 보정된 스펙트럼을 얻는다. 제안된 방법은 상대적으로 적은 사전 지식을 요구하면서 기존의 몇몇 방법들에 비해 우수한 결과를 보여주었다.

교통사고 후 한방병원에 입원한 일자목증후군 환자를 대상으로 한 진단방법의 비교 평가 및 경침사용의 유효성 연구 (The Study of Effectiveness of Wooden Pillow and Comparison Evaluation of diagnosis method on Straightening of Cervical Curvature Patient)

  • 이치호;전동휘;이은정;오민석
    • 혜화의학회지
    • /
    • 제24권2호
    • /
    • pp.1-16
    • /
    • 2016
  • Objectives : This study was designed to evaluate various tools including C-spine X-ray for estimating cervical curvature and identify the effect of wooden pillow on patients diagnosed with straightening of cervical curvature. Methods : This study was carried out on 51 subjects who were encountered traffic accident suffering cervical pain and diagnosed with straightening of cervical curvature by X-ray. 51 subjects were divided into wooden pillow(experimental) group and conservative therapy(control) group. Visual analogue scale, neck disability index and lateral pictures were used and compared after treatment. C-spine AP., Lat. X-ray were used on admission day to calculate cervical curvature and scoliosis by various ways. Results : 4 different measurements of cervical curvature didn't show common results. Both wooden pillow(experimental) group and conservative therapy(control) group showed significant improvement in the visual analogue scale(VAS) and neck disability index(NDI) after hospital treatment. Comparison between center line pictured by lateral view and C-spine Lat. pictured by X-ray showed significant difference in cervical curvature. Lateral deviation of cervical vertebra showed lengthened distance between mastoid process and spinous process of C7. Conclusion : As a result of this research, I found out that various tools for calculating cervical lordosis could derive different results and C-spine AP., Lat X-ray could cause artificial cervical lordosis. According to visual analogue scale(VAS) and neck disability index(NDI) wooden pillow was not effective to reduce pain & disability caused by straightening of cervical curvature. Futhermore, correction effect of straightening of cervical curvature and scoliosis by wooden pillow was weak.