• Title/Summary/Keyword: X-ray measurement

Search Result 1,305, Processing Time 0.039 seconds

Microstructural and Magnetic Characterization of Fe Nanosized Powder Synthesized by Pulsed Wire Evaporation

  • Kim, Deok Hyeon;Lee, Bo Wha
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.100-103
    • /
    • 2017
  • We studied the microstructure and magnetic properties of Fe nanosized powder synthesized by the pulsed wire evaporation method. The x-ray diffraction spectrum confirmed that this powder had a pure ${\alpha}$-Fe phase. Scanning electron microscope and transmission electron microscope measurements indicated that the prepared powder had uniform spherical shape with core-shell structure. The mean powder size was about 35 nm and the thickness of the surface passivation layer was about 5 nm. Energy dispersive X-ray spectroscopy measurement indicated that the surface passivation layer was iron oxide. Magnetic field dependent magnetization measurement at room temperature showed that the maximum magnetization of the prepared powder was 177.1 emu/g at 1 T.

A Comparative Study on the Changes of Pelvic Alignment between AP View of the Pelvis in Standing and Supine Position (Pelvic AP X-ray 촬영 자세에 따른 골반변위 변화의 비교 연구)

  • Lee, Kyung-Moo;Park, Dong-Su;Kim, Soon-Joong;Jeong, Su-Hyeon
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.18 no.4
    • /
    • pp.161-169
    • /
    • 2008
  • Objectives : This study was carried out to investigate the relationship of pelvic alignment between AP view of the pelvis in standing and supine position. Methods : Sixteen healthy peoples who get $51.59{\pm}4.14$ as average in SF-36 were evaluated by X-ray findings. After measuring innomiate measurement, off centering measurement, sacral ala measurement, illium shadow measurement, the area of obturator foramen, those were analyzed statistically. Results : It was not all to be corresponded to distort pelvic alignment of AP view of the pelvis in standing and in supine. Sometimes it was the opposite result. Conclusions : These results suggest that the diagnosis of pelvic alignment to go through on each position is brought about disagreement with each other.

Simulation of the Digital Image Processing Algorithm for the Coating Thickness Automatic Measurement of the TRISO-coated Fuel Particle

  • Kim, Woong-Ki;Lee, Young-Woo;Ra, Sung-Woong
    • Journal of Information Processing Systems
    • /
    • v.1 no.1 s.1
    • /
    • pp.36-40
    • /
    • 2005
  • TRISO (Tri-Isotropic)-coated fuel particle is widely applied due to its higher stability at high temperature and its efficient retention capability for fission products in the HTGR (high temperature gas-cooled reactor), one of the highly efficient Generation IV reactors. The typical ball-type TRISO-coated fuel particle with a diameter of about 1 mm is composed of a nuclear fuel particle as a kernel and of outer coating layers. The coating layers consist of a buffer PyC, inner PyC, SiC, and outer PyC layer. In this study, a digital image processing algorithm is proposed to automatically measure the thickness of the coating layers. An FBP (filtered backprojection) algorithm was applied to reconstruct the CT image using virtual X-ray radiographic images for a simulated TRISO-coated fuel particle. The automatic measurement algorithm was developed to measure the coating thickness for the reconstructed image with noises. The boundary lines were automatically detected, then the coating thickness was circularly by the algorithm. The simulation result showed that the measurement error rate was less than 1.4%.

Using the X-ray Image, Augmented Reality based electrocardiogram measurement system Development (X-ray 이미지를 활용한 증강현실 기반 심전도 측정시스템 개발)

  • Lee, Kwang-In;Jang, Jin-Soo;Lee, Tae-Ro
    • Journal of Digital Convergence
    • /
    • v.14 no.9
    • /
    • pp.331-339
    • /
    • 2016
  • Chronic diseases are increasing nowadays as daily habits changed due to economic growth. Among chronic diseases, heart cerebrovascular disease is one of the major causes of death in South Korea that accounts for approximately 20% of mortality. Tests to measure anomaly of the heart is ECG tests, which measures and analyzes the electrical heart activity. Any mistakes in lead attachment location critically affects ECG testings, and statistical facts showed that only 2.8% of the nurses properly located leads to patients. As a solution, this paper proposes a system based on a projection-based augmented reality technology to generate X-ray images to the patient's chest to point out exact attachment locations of ECG leads. Evaluation comparison results showed a 2.6 cm difference between the conventional system and the proposed system. ECG test results also showed significant signal differences between the systems in leads V1, V2, and V3. The ECG measured accurately by the proposed system would help greatly in patient management and clinical decisions of clinicians.

X-ray properties measurement of Flat panel Digital X-ray gas detector (평판형 디지털 엑스레이 가스 검출기의 엑스선 특성 측정기술에 관한 연구)

  • Yoon, Min-Seok;Cho, Sung-Ho;Oh, Kyung-Min;Jung, Suk-Hee;Nam, Sang-Hee;Park, Ji-Goon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.1
    • /
    • pp.17-21
    • /
    • 2009
  • The Recently, large area matrix-addressed image detectors are investigated for X-ray imaging with medical diagnostic and other applications. In this paper, a new flat panel gas detector for diagnostic X-ray imaging is proposed, and its characteristics are investigated. The research of flat panel gas detector is not exist at all. Because of difficulty to inject gas against to atmospheric pressure. So almost gas detector made by chamber shape. We made flat panel sample by display technique. (ex: PDP, Fed, etc.) The experimental measurements, the transparent electrodes, dielectric layer, and the MgO protection layer were formed in front glass. And, the X-ray phosphor layer and address electrodes are formed in the rare glass. The dark current, the x-ray sensitivity and linearity as a function of electric field were measured to investigate the electrical properties. From the results, the stabilized dark current density and the significant x-ray sensitivity were obtained. And the good linearity as a function of exposure dose was showed in wide diagnostic energy range. These results means that the passive matrix-addressed flat panel gas detector can be used for digital x-ray imaging.

  • PDF

A Study on the Fatigue-Fractured Surface of Normalized SS41 Steel and M.E.F. Dual Phase Steel by an X-ray Diffraction Technique (X-선 회절에 의한 SS41 불림재와 M.E.F. 복합 조직강의 피로 파단면 해석에 관한 연구)

  • Oh, Sae-Wook;Park, Young-Chul;Park, Soo-Young;Kim, Deug-Jin;Hue, Sun-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.1
    • /
    • pp.10-18
    • /
    • 1996
  • This study verified the relationship between fracture mechanics parameters and X-ray parameters for normalized SS41 steel with homogeneous crystal structure and M.E.F. dual phase steel(martensite encapsulated islands of ferrite). The fatigue crack propagation test were carried out and X-ray diffraction technique was applied to fatigue fractured surface. The change in X-ray parameters(residual stress, half-value breadth) according to the depth of fatigue fractured surface were investigated. The depth of maximum plastic zone, $w_y$, were determined on the basis of the distribution of the half-value breadth for normalized SS41 steel and that of the residual stress for M.E.F. dual phase steel. $K_{max}$ could be estimated by the measurement of $w_y$.

  • PDF

The Analysis of Lattice Distortion of $Ba(Zn_{1/3}Ta_{2/3})O_3$ by X-ray Diffraction (X-선 회절분석법에 의한 $Ba(Zn_{1/3}Ta_{2/3})O_3$의 격자 비틀림 측정)

  • Kim, Chong-Don;Kim, In-Tae;Je, Hae-June
    • Analytical Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.111-114
    • /
    • 1992
  • Ordering phenomena were observed for Zn and Ta cations of $Ba(Zn_{1/3}Ta_{2/3})O_3$ under particular heat treatments, followed by a considerable lattice distortion. This lattice distortion was measured by X-ray powder diffraction with a precision of higher than 1/10,000. From this investigation, a significant lattice distortion occurred within 30 min. of sintering at $1350^{\circ}C$, and it was increased with sintering time.

  • PDF

Assessment of Congruence Angle according to the Central X-ray in the Merchant View of Patellofemoral Joint (슬대퇴관절의 Merchant View에서 중심 X선 위치에 따른 일치각 평가)

  • Kim, Hyun-jin;Joo, Yeong-chul;Choi, Jae-ho;Lim, Woo-taek
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.423-428
    • /
    • 2019
  • The Precise measurement of the knee's Congruence angle is required for diagnosis of patella dislocation. The purpose of this study is to consider the distortion diagram and usefulness about the test of the bilateral side and one side through the evaluating congruence angle from Merchant view of patellofemoral joint to central X-ray. We've evaluated the sulcus angle and Congruence angle following central X-ray's changes when we took Merchant view of patellofemoral joint aimed to right lower limb from human whole body phantom. The subject of the evaluation was classified as normal group and varus group, and the varus group has experimented with External rotation of legs as 15° and 30°. When normal groups result as 0, 7.5, 15 cm, it was measured as 17.25 ± 1.34°, 19.60 ± 1.41°, 20.55 ± 1.77° each. The gap between minimal and maximum angle was 3.3°, and the value was shown as getting bigger when it further away from the centeral X-ray. When Congruence angle in 15° varus group was 0, 7.5, 15 cm, it was each 16.45 ± 1.34°, 17.10 ± 0.99°, 17.80 ± 1.13°. And when Congruence angle in 30° varus group was 0, 7.5, 15 cm, it was measured each 18.35 ± 1.63°, 18.95 ± 1.06°, 19.60 ± 1.41°. The difference between minimum and maximum of angle in 15° varus group and 30° varus group was each 1.35° and 1.25°, the angles have shown as increasing the further away from the center. The patellofemoral joint showed that the congruence angle increases as the further away from Central X-ray, and also it is judged that is possible to change the congruence angle by a degree of varus knee. Thus, accurate measurement of the congruence angle is shown to advantage that methods for examining by split each side at two times than methods for examining both sides at a time. Therefore, it is expected to helpful on the diagnostic side of patella dislocation and subluxation.

Electrical and Optical Properties of Vacuum-Evaporated CdS Films for the Window Layer of $CdS/CuInSe_2$ Solar Cells. ($CdS/CuInSe_2$태양전지의 Window Layer로 쓰이는 CdS박막의 진공증착법에 따른 전기적.광학적 성질)

  • Nam, Hee-Dong;Lee, Byung-Ha;Park, Sung
    • Korean Journal of Crystallography
    • /
    • v.8 no.2
    • /
    • pp.105-110
    • /
    • 1997
  • 1μm-CdS films for a window layer of CdS/CuInSe2 solar cell have been prepared by vacuum of 1x10-3 mTorr. Source and substrate temperature ranges were used 800-1100'C and 50-200℃ respectively. Structural, electircal and optical properties of CdS films have been investigated by X-ray diffractometer (XRD), scanning electron microscopy (SSEM), electrical resistivity, the Hall measurement and optical transmission spectra. Electrical resistivity and optical transmission of the CdS films decreased with the increase in CdS source temperature without substrate heating. All the films had hexagonal structure and strong texture with (002) orientation of grain normal to the substrate glass. CdS films evaporated at 1000℃ were the highest electrical conductivity of 0.9(S/cm). Electrical resistivity and optical transmission at the substrate temperature of 100℃ were 40(Ω,cm) and 80% respectively.

  • PDF