• 제목/요약/키워드: X-ray generator control

검색결과 36건 처리시간 0.027초

디지털 평판형 검출기에서 Control Panel의 Density Display와 Sensitivity 설정이 조사선량(mAs)과 획득영상에 미치는 영향에 관한 연구 (Study on the Exposure Dose(mAs) and acquisition Image set up Density Display and Sensitivity of control Panel for the Digital Flat-Panel-Detector)

  • 김병기;김상건;차선화;최준구;이준;이민우;김순배;김경수
    • 대한디지털의료영상학회논문지
    • /
    • 제9권2호
    • /
    • pp.17-21
    • /
    • 2007
  • The purpose to recognize change of average pixel value of acquisition image by control panel's density and right set up method of speed (sensitivity) and exposure dose(mAs) change that dose in purpose digital flatpanel-detector. X -ray generator DHF-158H2(Hitachi, Japan). Detector CXDI 4OG(Canon, Japan), 12 : 1 grid and exposure ray 135 kVp, 250 mA, 10 ms. focus-detector distance 180 cm and used AEC mode. DICOM reflex analysis program used image J that is digital reflex analysis program that offer in United States America National Health Center(National Institutes of Health : NlH) phantom used chest phantom(Anthromorphic : Flukebrome.medicaI USA). An experiment chest phantom that consist by formation equivalence material use because density value( -3${\sim}$+3) in X-ray control panel and seep that is speed step(slow, medium, fast) each control experimentalize. image analysis reflex neted through an experiment using image j each image compare. These was change in dose according to slow, medium, fast and density's change in an experiment result. According to detector sensitivity and density condition set, dose was relationship dissimilarity 500% from 200%. The dose came highest when is density +3 to slow. and dose more increases gray scale's extent could know that rise. Could know whether how equipment set is important through this experiment. cause of disease which change by digital radiography system forward is thought to increase more, it is considered that suitable education by this and continuous interest about equipment need absolutely.

  • PDF

유방촬영용 방사선발생장치의 관전압과 관전류 시험 분석 (Testing and Analysis of Tube Voltage and Tube Current in The Radiation Generator for Mammography)

  • 정홍량;홍동희;한범희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권1호
    • /
    • pp.1-6
    • /
    • 2014
  • 유방촬영용 방사선발생장치의 성능 관리 및 품질관리에 적용되는 관전압과 관전류량을 IEC(International Electrotechnical Commission; 국제 전기 기술위원회) 60601-2-45에서 제시한 표준을 근거로 시험하고 분석한 결과 다음과 같은 결론을 얻었다. 관전압에 따른 제조년도별 표준편차 값은 2001~2010 사이에서 3.15로 가장 크게 나타났고, 관전류량에 따른 제조년도별 표준편차 값은 2000년 이전에서 6.38로 가장 크게 나타났으며, 2011년 이후에 제조된 장치에서는 PAE(Percent Average Error; 백분률표준오차)의 표준편차가 비교적 적게 나타났다. 이는 최근에 제조된 유방촬영용 방사선발생장치의 관전압과 관전류량이 정확한 성능을 유지하고 있음을 알 수 있다. 본 연구결과를 기초자료로 활용하여 유방촬영용 방사선발생장치의 성능 및 품질 관리를 유지하므로 현재 식품의약품안전청의 "진단용 방사선발생장치의 안전관리에 관한 규칙"에서 규정하고 있는 3년 검사주기 동안에 자가 점검으로 방사선발생장치의 방사선에 대한 안전성 확보와 사용하는 X선 장치의 성능을 일관성(constancy) 있게 유지하도록 함으로서 궁극적으로 방사선에 대한 국민피폭선량을 줄일 수 있는 기대효과가 있을 것으로 기대된다.

Investigation of Standard Evaluation for the Quality Control of General X-ray Systems

  • Kang, Byung-Sam;Son, Jin-Hyun;Kim, Byoung-Jun;Park, Deok-Woo;Jung, Byoung-Hoon;Lee, Hyo-Jin;Hong, Ji-Young;Kim, Seung-Chul
    • 대한디지털의료영상학회논문지
    • /
    • 제12권2호
    • /
    • pp.71-79
    • /
    • 2010
  • Thanks to the great development of technology in radiation, we are now able to reduce radiation exposure to the patients, and the radiographer and expenses in medical sector. We are also trying to produce ideal images which maintain useful information. These kinds of effort are increasing over the world. For that reason, we should get images which include necessary data of patients. Then it also can help to reduce radiation exposure to the patients. Therefore, we need to know the problems that cause a falling off in image's quality and check on generator in case of their electronic and mechanical errors. And moreover, we should anticipate the possibility of devices errors and prevent them with regular quality control. This investigation was conducted in medical institutions, institute of educations and hospitals. They are all in Seongnam-City. We used PMX-III, kVp meter to implement kVp test, mR / mAs output test, light fiel / beam alignment test, Reproducibility of exposure dose, half value layer test, reproducibility of exposure time test. in the case of hospitals, they perceive the importance of regular quality control and organize the regular quality control team so they can be satisfied with the error standard in most experiments. On the other hand, when it comes to medical institutions and institute of educations, they perceive the importance of regular quality control less than hospitals do. Radiographer need to understand the importance of regular quality control and practice it so they can get the fine ideal image with the lower dose to the patient.

  • PDF

진단용 방사선 발생장치의 수시 정도관리 항목 및 기준에 관한 기초 연구 (A Base Study on the Constancy Quality Control Test and Clause of Diagnosis Radiation Equipment)

  • 허예지;김교태;노시철;남상희;박지군
    • 한국방사선학회논문지
    • /
    • 제8권3호
    • /
    • pp.105-110
    • /
    • 2014
  • 국내 진단용 방사선 발생장치는 3년 주기로 시행되는 정기적인 정도관리 검사에 앞서 일별, 주별, 월별, 분기 반기별로 시행하는 수시 정도 관리에 대한 항목 및 규정이 명확하게 지정되어 있지 않다. 미국과 유럽 등의 선진국에서는 정도 관리 항목에 대해 검사를 수행하는 검사자를 구분하여 국가 기관에 보고하도록 되어 있으므로 체계적인 검사 수행과 더불어 검토가 가능하다. 그러므로 의료 장비의 현대화가 이루어지는 시점에서 국외의 주기별 정도관리 시스템을 국내 진단용 방사선 발생 장치에 적합하도록 도입하여 정도관리 항목과 기준의 재정립이 반드시 필요하다. 이에 본 논문에서는 진단용 방사선 발생장치 중 가장 빈번히 사용되고 있는 일반 X선 촬영 장치의 3년 정기점검 사이에 주기적인 수시 정도 관리 검사 항목과 방법 및 기준 수립을 위해 미국, 캐나다 등의 국외 문헌 조사 및 국제 전자 기술 위원회(International Electro-technical Commission, IEC)의 규정 항목과 비교하였다. 이를 바탕으로 국내 수시 정도관리 항목 신설 시 필요한 검사 항목 및 기준 설정을 위한 기초 자료로 제시하고자 하였다.

Dual-energy 컴퓨터단층촬영에서 장비 제공선량과 측정선량 비교 (Comparison of Estimated and Measured Doses of Dual-energy Computed Tomography)

  • 김영균;김연민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권5호
    • /
    • pp.405-411
    • /
    • 2018
  • We will provide basic data on the evaluation of patient dose in terms of DECT quality control by comparing the equipment-provided dose with the measured dose according to the configuration method of the X-ray generator by the manufacturer of the dual-energy CT unit. For computed tomography (CT) equipment, Discovery 750HD, Aquilion ONE GENESIS Edition, and Somatom Definition Flash were used. The $CTDI_{vol}$ value was measured by inserting the Unfors Xi ion chamber into a 32 cm PMMA acryl Phantom. The results of estimated $CTDI_{vol}$ DECT and measured $CTDI_{vol}$ showed that the dose difference between DECT 80 + 140 kVp of G company was at least 0.51% and -1.90% max, and measured $CTDI_{vol}$ was slightly lower (p<0.05). The difference of 80 + 140 kVp of S company was the minimum of 5.84% and the maximum of 7.52% (p<0.05). The measured $CTDI_{vol}$ was less than estimated $CTDI_{vol}$. The C company's 80 + 135 kVp showed a difference of at least 7.58% and a maximum of 13.58% (P<0.05), and all of measured $CTDI_{vol}$ was less. The linearity of exposure dose for all DECT equipment was very linearly reflected with $R^2$ being 0.97 or above, and the measured dose of the ionization chamber was less than the predicted dose of the monitor.

방사선 측정장치의 저준위 방사선 측정과 방사선량의 급격한 변화에 따른 장치의 반응 속도개선에 관한 연구 (A Study On Low Radiation Measurement of Radiation Measuring Devices and Improvement of Reaction Speed according to the Rapid Change of Radiation Dose)

  • 이주현;이승호
    • 전기전자학회논문지
    • /
    • 제18권4호
    • /
    • pp.544-551
    • /
    • 2014
  • 본 논문에서는 방사선 측정장치의 저준위 방사선 측정 알고리즘과 방사선량의 급격한 변화에 따른 장치의 반응 속도개선을 위한 알고리즘 및 장치의 구성을 제안한다. 저준위 방사선 측정의 측정 정밀도를 개선하기 위한 알고리즘은 방사선 측정센서로부터 수집된 펄스의 누적평균을 기준으로 하는 듀얼 윈도우 방사선 수치 측정법을 사용한다. 방사선량의 급격한 변화에 따른 장치의 반응 속도개선을 위한 알고리즘은 신규로 입력된 6초 동안의 데이터 패턴분석을 통한 듀얼 윈도우 방사선 수치 측정법을 사용한다. 제안된 알고리즘의 검증을 위한 하드웨어 장치로는 센서 및 고전압 발생부, 제어부, 충전 및 전원회로부, 무선통신부, 디스플레이부 등으로 구성되어 있다. 제안된 알고리즘에서 사용한 듀얼 윈도우 방사선 수치 측정법을 실험한 결과, 기존 5uSv/h 수준의 저선량 한계에서 대체로 불확도가 낮아지고 선형성이 개선됨을 확인할 수 있었다. 또한 급격한 방사선량의 변화에 대한 장비의 반응속도 개선에 대해 실측실험을 통해 6초 이후에 변화된 수치가 반응함을 확인하였다. 따라서 제안된 알고리즘이 급격한 변화에 따른 장치의 반응속도가 개선됨을 확인할 수 있었다.