• 제목/요약/키워드: X-ray film

검색결과 2,285건 처리시간 0.028초

Temperature Dependent Octahedral Tilting Behaviors of Monoclinic and Tetragonal SrRuO3 Thin Films

  • Lee, Sung Su;Seo, Okkyun;Kim, Jaemyung;Song, Chulho;Hiroi, Satoshi;Chen, Yanna;Katsuya, Yoshio;Sakata, Osami
    • Journal of the Korean Physical Society
    • /
    • 제73권10호
    • /
    • pp.1529-1534
    • /
    • 2018
  • We used in-situ synchrotron X-ray scattering to investigate phase transformations of octahedral tilted monoclinic $SrRuO_3$ (MSRO) and tetragonal SRO (TSRO) thin films on $SrTiO_3$ (STO) substrates. The octahedral tilted MSRO thin films were highly crystalline and the monoclinic distortion angle was $0.45^{\circ}$. The phase transition temperature from the MSRO to TSRO phase occurred at approximately $200^{\circ}C$ as a second order transition. Conversely, no phase transformations of the TSRO thin film occurred within the range from RT to $250^{\circ}C$. The octahedral $RuO_6$ rotation was strongly affected by the phase transformation in the SRO thin films.

피사체(被射體)두께에 따른 선량분포(線量分布) (Dosimetry according to the Object Thickness)

  • 이상석;박성옥
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제2권1호
    • /
    • pp.85-88
    • /
    • 1979
  • When X-radiation passes through the human body; some is transmitted some is truly absorbed, and some is scattered. In diagnostic radiography, scattered radiation can reach the film if no protective measures are taken. This scattered ray increased density which not necessary for image formation. We studied about absorbtion, scattered ray and the way of get rid of scatter ray according to the x-ray tube kilovoltage and obtained results as follow; 1. Absorbtion ray increased proportion to KVP. 2. Scattered ray increased at high KVP and thick object. 3. Secondary radiation of the primary increased at high KVP and thick object. 4. Remove .ate of scattered ray decreased at thick object and increase at low KVP make use of 6:1 grid ratio

  • PDF

소동물 X-선 진단에 있어서 광범위 관용도 필림의 이용에 관하여 (Application of Wide Latitude Film to Radiographic Diagnosis in Small Animal)

  • 최민철
    • 한국임상수의학회지
    • /
    • 제9권2호
    • /
    • pp.473-481
    • /
    • 1992
  • To elucidate the applicability of the wide latitude X-ray film for radiographic diagnosis and treatment of diseases in small animals, the quality of the wide latitude film was compared with that of the standard latitude film which is commonly used in veterinary clinic. The images of head, neck, thorax, abdomen, extremities and joints were radiographed with the wide latitude and standard latitude film in fourteen dogs. In soft tissues such as abdominal organs, lung, skin, mammary glands, the clearer and higher contrast of the image was observed on the wide latitude film. And these advantages were more apparent in pneumoeritoneography. Therefore. it can be suggested that the wide latitude film is practically useful for the evaluation of the images of soft tissues, and also can be used on hard tissue radiography with the same quality as the standard latitude film.

  • PDF

비정질 셀레늄의 박막 제조공정에 따른 미세구조와 IV특성 (The X-ray Detection and morphology Characteristics on Evaporation Temperature of amorphous Selenium based digital X-ray detector)

  • 공현기;차병열;이규홍;김재형;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 센서 박막재료 반도체재료 기술교육
    • /
    • pp.51-54
    • /
    • 2002
  • Recently, due to its better photosensitivity in X-ray, the amorphous selenium based photoreceptor is used on digital direct method conversion material. Compared to other photoconductive material, amorphous selenium has good X-ray response characteristic and low leakage current. It has many parameters of detecting X-ray response on selenium. Among of them, it is well known that manufacture of a-Se is the most basic element. In this paper, we fabricated two types of amorphous selenium sample which had time variable. The one was fabricated continuous deposition sample and the other was step by step sample. Thickness of sample was $300{\mu}m$ and top electrode was evaporated gold. We investigated the leakage current and photo current of them and analysed their electrical characteristics. For analyzing morphology of samples, SEM and surface was pictured. We found that step by step deposition method could be applied for novel fabricating amorphous selenium film.

  • PDF

PIB법을 이용한 대면적 $HgI_2$ 검출기의 I-V 특성평가 (I-V Measurements of large area $HgI_2$ X-ray detector produced by PIB method)

  • 김경진;박지군;강상식;차병열;조성호;신정욱;문치웅;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.254-255
    • /
    • 2005
  • In this paper, we investigated electrical characteristics of the X-ray detector of mercuric iodide (HgI2) film fabricated by PIB(Particle-in-Binder) Method on ITO substrates 17cm$\times$20cm in size with thicknesses ranging from approximately 200${\mu}m$ to 240${\mu}m$. In the present study, using I-V measurements, their electrical properties such as leakage current, X-ray sensitivity, and signal-to-noise ratio (SNR),were investigated. The results of our study can be useful in the future design and optimization of direct active-matrix flat-panel detectors (AMFPD) for various digital X-ray imaging modalities.

  • PDF

Barge 방식에 의한 요추부 척추측만증과 추간판 탈출증의 X-ray 비교분석 (The Comparative analysis of X-ray film on Lumbar Scoliosis and HNP by Barge Method)

  • 김규섭
    • 척추신경추나의학회지
    • /
    • 제6권1호
    • /
    • pp.53-61
    • /
    • 2011
  • Objective: The purpose of this study is to evaluate the disc block subluxation for lumbar scoliosis and herniation of nucleus pulpous (HNP). Methods: We used AP & Lateral view X-ray for patients. And we measured of disc wedge angle, vertebral body rotation to evaluate the typical and atypical disc block subluxation. Results: On the analysis of the lateral view X-ray, 4th lumbar intervertebral disc angle (I.V.D angle) showed $4^{\circ}$, $5^{\circ}$, $3^{\circ}$, $0^{\circ}$ in the cases. On the 4th lumbar analysis of the AP view X-ray, lumbar scoliosis showed right disc wedge angle was $11^{\circ}$ (case 1), $17^{\circ}$ (case 2) and left vertebral body rotation was 13mm, 6mm. Lumbar HNP showed left disc wedge angle was $5^{\circ}$ (case 3), $4^{\circ}$ (case 4) and left vertebral body rotation was 2mm, 4mm. Conclusions: Disc block subluxation has been in lumbar scoliosis, but not been in lumbar HNP.

  • PDF

디지털 X-ray imaging을 위한 Hybrid 방식의 다층구조 설계 (Multi-layer design of Hybrid method for digital X-ray imaging)

  • 조성호;박지군;이동길;김대환;김재형;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 센서 박막재료 반도체 세라믹
    • /
    • pp.75-78
    • /
    • 2003
  • In recent years, there has been keen interest in developing flat panel detectors for all modalities of radiology, including gerneral radiology, fluoroscopy, electronic portal imaging, and mammography. In this paper, we report the new hybrid x-ray detector consisted of ZnS(Ag) photoemission layer and a-Se photoconductor layer to resolve problem of conventional x-ray detector such as the direct detector and the indirect detector. To design the structure of ZnS(Ag)/a-Se detector, the penetrated energy spectrum and absorption fraction was estimated using MCNP 4C code. Also, we carried out the experiment to demonstrate the result of MCNP 4C code. Experimental results showed that the absorption fraction of $500{\mu}m$-ZnS(Ag) film was above 87%, 75% at 60 and 80 kVp. As a results, we can determined the thickness of suitable phosphor and the thickness of photoconductor.

  • PDF

분무열분해법으로 성장한 $Ru_{1-x}Ir_xO_2$ 박막의 구조와 전기적 특성 (Structure and Electrical Properties of $Ru_{1-x}Ir_xO_2$ Films Deposited by a Spray Phrolysis)

  • 서동주;이관교;이재연
    • 한국진공학회지
    • /
    • 제5권1호
    • /
    • pp.67-72
    • /
    • 1996
  • $RU_{1-x}Ir_xO_2$ films were deposited on the quartz substrate by a spray pyrolysis method. The x-ray diffraction patterns showed that the structure of the $RU_{1-x}Ir_xO_2$ film was tetragonal and the lattice constant $a_o$ and $c_o$ were increased from 4.495 A to 4.058 A and from 3.092A to 3.156 A, respectively as the Ir composition varied from 0.0 to 1.0. The $RU_{1-x}Ir_xO_2$ film was metallic and the resistivity of the samples was increased from $7{\times}10^{-5}{\Omega}\textrm{cm}$ to $48{\times}10^{-5}{\Omega}\textrm{cm}$ with increasing the Ir x. The surface of the sample was slightly roughed, the grain size and the grain boundary width were increased as the Ir composition varied from 0.0 to 1.0.

  • PDF

XAS Studies of Ion Irradaited MgO Thin Films

  • Suk, Jae-Kwon;Gautam, Sanjeev;Song, Jin-Ho;Lee, Jae-Yong;Kim, Jae-Yeoul;Kim, Joon-Kon;Song, Jong-Han;Chae, Keun-Hwa
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.312-312
    • /
    • 2012
  • Magnesium oxide has become focus for research activities due to its use in magnetic tunnel junctions and for understanding of do ferromagnetism. Theoretical investigations on such type of system indicate that the presence of defects greater than a threshold value is responsible for the magnetic behaviour. It has also been shown experimentally that by decreasing the film thickness and size of nanoparticles, enhancement/increase in magnetization can be achieved. Apart from the change in dimension, swift heavy ions (SHI) are well known for creating defects and modifying the properties of the materials. In the present work, we have studied the irradiation induced effects in magnesium oxide thin film deposited on quartz substrate via X-ray absorption spectroscopy (XAS). Magnesium oxide thin films of thickness 50nm were deposited on quartz substrate by using e-beam evaporation method. These films were irradiated by 200 MeV Ag15+ ion beam at fluence of $1{\times}10^{11}$, $5{\times}10^{11}$, $1{\times}10^{12}$, $3{\times}10^{12}$ and $5{\times}10^{12}ions/cm^2$ at Nuclear Science Centre, IUAC, New Delhi (India). The grain size was observed (as studied by AFM) to be decreased from 37 nm (pristine film) to 23 nm ($1{\times}10^{12}ions/cm^2$) and thereafter it increases upto a fluence of $5{\times}10^{12}ions/cm^2$. The electronic structure of the system has been investigated by X-ray absorption spectroscopy (XAS) measurements performed at the high energy spherical grating monochromator 20A1 XAS (HSGM) beamline in the National Synchrotron Radiation Research Center (NSRRC), Taiwan. Oxides of light elements like MgO/ZnO possess many unique physical properties with potentials for novel application in various fields. These irradiated thin films are also studied with different polarization (left and right circularly polarized) of incident x-ray beam at 05B3 EPU- Soft x-ray scattering beamline of NSRRC. The detailed analysis of observed results in the wake of existing theories is discussed.

  • PDF