• 제목/요약/키워드: X-ray exposure parameters

검색결과 43건 처리시간 0.025초

한국 폐경 여성의 골다공증 위험 인자에 관한 연구 (Risk Factors for Postmenopausal Osteoporosis in Korea)

  • 이동윤;구승엽;김석현;최영민;문신용;김정구
    • 한국건강관리협회지
    • /
    • 제2권2호
    • /
    • pp.137-148
    • /
    • 2004
  • Objective : To identify the risk factors for postmenopausal osteoporosis in Korea Materials and methods : Bone mineral density (BMD) at the lumbar spine and femoral neck was measured by dual energy X-ray absorptiometry in 808 apparently normal postmenopausal Korean women. Questions about life style, demographic parameters, medical history and social habits etc. were asked on these women; 2ll women with normal bone mineral density, and 597 women with osteopenia or osteoporosis. Results 'Age of >50 years, low body mass index (BMI; <18.5 kg/m2), long duration of menopause(>10 years), and previous history of fracture were associated with increased prevalence of osteopenia or osteoporosis. Women without the outside activity also showed a higher frequency of low bone mass, Risk for osteopenia or osteoporosis was low in women with high BMI (>23 kg/m2) and women with job. The prevalence of low bone mass appeared to be independent of the following parameters: socioeconomic status, familial history, smoking, drinking, exercise, previous use of oral contraceptive, coffee or milk consumption, and degree of sunlight exposure. Conclusion 'Age, BMI, duration of menopause, previous history of fracture and degree of outside activity are the risk factors for postmenopausal osteoporosis in Korea.

  • PDF

반복적인 복부 컴퓨터단층촬영 시행 시 환자선량 감소를 위한 관전압 변화 적용의 유용성 (Usefulness of Application of Tube Voltage Changes to Reduce Patient Dose during Abdominal CT Follow up)

  • 윤준;김현주
    • 한국방사선학회논문지
    • /
    • 제15권3호
    • /
    • pp.293-299
    • /
    • 2021
  • CT 장치를 이용하여 주기적인 검사를 시행하는 환자의 불가항력적 방사선 피폭을 줄이기 위해 다양한 스캔 파라미터 중 X선의 투과력과 밀접한 관전압의 변화를 통해 환자 선량을 감소시킬 수 있는 스캔 방법을 알아보았다. 실험결과 일반적으로 임상에서 많이 적용하는 120 kVp 대신 100 kVp를 적용하여 스캔 시 CTDI가 약 41 % 감소하였다. 또한 화질 변화정도는 CT value는 1046.1±3.7 HU, Pixel value는 71.4±7.9로 측정되었으며 통계분석결과 큰 차이가 없는 것으로 분석되었다(0.05

PET/CT에서 Pitch와 Rotation Time의 변화를 이용한 능동적인 프로토콜 사용에 대한 연구 (A Study on the Use of Active Protocol Using the Change of Pitch and Rotation Time in PET/CT)

  • 장의순;곽인석;박선명;최춘기;이혁;김수영;최성욱
    • 핵의학기술
    • /
    • 제17권2호
    • /
    • pp.67-71
    • /
    • 2013
  • PET/CT검사에서 CT촬영조건의 변화는 영상의 화질 및 환자가 받는 피폭선량에 영향을 미친다. 본 연구는 CT 매개 변수 중 Pitch와 X-선관 회전시간 변화에 따른 선량대비 CT 영상의 질과 이로 인해 PET상에서 SUV에 미치는 영향을 비교 평가하고자 하였다. Discovery STe PET/CT 장비를 이용하여 영상을 획득하였다. QA Phantom과 AAPM Phantom을 이용한 CT 영상 획득 시 Pitch는 0.562, 0.938, 1.375, 1.75:1로 4단계, X-선관 회전시간은 0.5에서 1.0까지 0.1초씩 증가시켜 6단계로 나누어 총 24개 조합을 적용한 영상을 각각 획득하였다. PET 영상은 $^{18}F-FDG$ 5.3 kBq/mL가 채워진 1994 NEMA PET Phantom을 이용하여 프레임당 2분 30초의 방출영상을 획득하였다. 각 조합의 CT 영상에 관심영역을 설정하고 CT number의 표준편차를 측정하였다. 동일한 영상에서 DLP변화에 따른 영상잡음의 예측값을 계산하여 예측값 대비 실측값의 비율을 구해 선량대비 영상잡음 효과를 비교하는 척도로 사용하였다. AAPM Phantom 영상에서 1.0 mm까지 식별이 가능한 지 확인하였다. NEMA PET Phantom의 방출영상에 관심영 역을 설정하고 SUV를 비교 평가하였다. Pitch가 0.562, 0.938, 1.375, 1.75:1로 변화할 때 영상잡음 효과는 QA Phantom에서 1.00, 1.03, 1.01, 0.96, AAPM Phantom에서 1.00, 1.04, 1.02, 0.97로 측정되었다. 회전시간의 증가에 따른 경우 QA Phantom에서 0.99, 1.02, 1.00, 1.00, 0.99, 0.99이었고, AAPM Phantom에서 1.01, 1.01, 0.99, 1.01, 1.01, 1.01로 SPSS Ver. 18을 이용하여 상관관계를 분석한 결과 피어슨 상관계수는 -0.059로 나타났다. 공간분해능에 대한 평가는 24개의 조합 모두에서 1.0 mm까지 육안으로 구별이 가능하였다. SUV의 경우 평균 SUV는 모든 조합에서 1.1로 모두 동일한 값을 나타내었다. Pitch 변화에 따른 CT 영상 평가에서 1.75:1을 적용 시 선량대비 가장 적은 영상잡음 효과를 보이며 공간분해능과 SUV에는 영향을 미치지 않는다. 그러나 회전시간 변화가 영상에 미치는 영향에는 유의한 차이가 없음을 알 수 있다. 결과에서와 같이 각 장비에 따른 선량대비 영상잡음이 적은 Pitch를 사용하고 환자의 체격에 따른 적절한 X-선관 회전시간을 이용한다면 환자의 피폭선량을 줄이면서 최적의 화질을 얻을 수 있는 프로토콜을 구성하는데 도움이 될 것이라 사료된다.

  • PDF

복부 방사선검사 자세가 유방선량에 미치는 영향 (Effects of Breast Dose on Plain Abdominal Position)

  • 주영철;김승혁
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권3호
    • /
    • pp.155-159
    • /
    • 2020
  • The purpose of this study is to investigate the effect of posture changes(Anteroposterior projection, Posteroanterior projection) in the plain abdominal examination on breast dose and to examine its clinical usefulness. This study was used a human body phantom and a glass dosimeter. Glass dosimeters were directly inserted from the center and outside of medial and lateral. In this study, the deep dose was measured in the right breast and the surface dose in the left breast. During the abdominal examination, the central X-ray incident point was perpendicularly incident to the image receptor 5 cm above the iliac crest. The exposure parameters were 82 kVp, 320 mA, 50 ms, x-ray field size 14×17 inch The distance between the center X-ray and the detector was fixed at 110 cm, and only the top two AEC chambers were used. As a result of this study, the medial and lateral side doses of the right breast were 535.73±30.68 μGy and 414.46±33.52 μGy for erect AP, and 145.80±18.52 μGy and 148.76±12.92 μGy in erect PA. The superficial breast dose was 754.00±68.36 μGy on the medial side and 674.06±45.58 μGy on the lateral side in the erect AP, 70.66±7.98 μGy on the medial side, and 86.46±15.35 μGy on the lateral side in the erect PA. There was a statistically significant difference in the difference between the mean values of the medial and lateral side doses in the deep and superficial areas of the breast according to the postural change (p <0.01). As a result of this study, If the abdominal radiography was examined in the PA position, the dose reduction effect was 72.78% on the medial side, 64.10% on the lateral side of the deep breast, 90.62% on the medial side, and 87.17% on the lateral side of the superficial breast compared to the AP position.

Isocyanates 폭로 근로자들의 기관지 과민성 (Bronchial Hyperresponsiveness in Workers Exposed to Isocyanates)

  • 최경숙;김규상;최병순;최정근;이세휘;문영한
    • Journal of Preventive Medicine and Public Health
    • /
    • 제29권1호
    • /
    • pp.103-112
    • /
    • 1996
  • We studied the association of nonspecific bronchial hyperresponsiveness with general characteristics, exposure concentration, respiratory symptoms, chest x-ray findings, past histories and pulmonary function. We determined bronchial hyperresponsiveness by methacholine challenge test. And we conducted a respiratory symptom questionnaire and performed spirometry on 111 workers occupationally exposed to isocyanates in various industries. About 21.6% of subjects had bronchial hyperresponsiveness. No significant differences were observed between the hyperresponsive and non-responsive group with respect to age, sex, employment period, height, and smoking histories. Cough and breathlessness were significantly associated with the bronchial hyperresponsiveness. The hyperresponsive group had more experience of bronchitis and asthma in the past than the non-responsive group. The lower $FEV_1\;and\;FEV_1%$ were closely related with bronchial hyperresponsiveness. Bronchial hyperresponsiveness seems to be associated with some of respiratory symptoms, past histories and pulmonary function parameters in workers exposed to isocyanates.

  • PDF

소아 흉부촬영 시 나이와 체격에 따른 입사피부선량 (Entrance Skin Dose According to Age and Body Size for Pediatric Chest Radiography)

  • 신귀순;민기열;김두한;이광재;박지환;이귀원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권4호
    • /
    • pp.327-334
    • /
    • 2010
  • 전리방사선의 피폭에 의한 암 유발확률은 소아가 성인에 비해 크기 때문에 소아 X선 검사 시의 환자선량을 정확히 파악하는 일은 중요하다. 그러나 우리나라는 소아 환자선량에 대한 연구가 활발하지 않다. 그러므로 본 연구에서는 7세 미만 소아를 대상으로 전리함을 이용하여 흉부검사 시의 입사피부선량(entrance skin dose, ESD)을 측정하여 나이, 키, 체중, 가슴두께와 ESD의 관계를 비교한 결과는 다음과 같았다. 소아는 나이에 따라서 키, 체중 및 가슴두께가 비슷한 양상으로 증가하므로, 흉부촬영 시 측정하기 힘든 가슴두께 대신에 나이에 따라서 촬영조건을 설정해도 무방함을 알 수 있었다. 2세 미만 소아의 흉부 A-P 검사 시, kVp는 A병원에서 더 높았으나, mAs는 반대로 B병원에서 높아, ESD 값이 B병원에서 약 1.7배 높았다. 그러나 4세 이상 소아의 흉부 P-A 검사 시에는 mAs는 같았고 kVp는 B 병원에서 7 kVp 높았으나, ESD값은 FID가 먼 B병원(180 cm)에서보다 더 가까운 A병원(130 cm)에서 1.4배 정도 높았다. 또한 같은 나이라도 A-P가 P-A보다 ESD값이 높았다. 나이별에 따른 ESD값을 보면, 1세 미만은 $154{\mu}Gy$, 1세에서 4세 미만은 $194{\mu}Gy$, 4세에서 7세 미만은 $138{\mu}Gy$으로 나타났다. 이 값은 일본의 JART의 권고량($200{\mu}Gy$)보다 낮으나, EC(유럽위원회)나 영국의 NRPB의 권고량보다 높으며, 2009년 12월에 식품의약품안전평가원에 제출된 용역보고서의 진단참고준위(5세 소아에서의 중간값이 $100{\mu}Gy$)보다 높다. 결론적으로 ESD는 X선장치 시스템의 차이보다는 방사선사의 경험적 실행에 의한 촬영조건의 차이에 의해서 크게 달라짐을 알 수 있었으며, 또한 나이가 많다고 더 많은 선량을 받는 것은 아니다. 따라서 나이에 따른 소아의 적정 참고준위의 확립과 점진적인 환자선량의 저감화가 반드시 필요하다.

나선형 단층방사선사진촬영에서 촬영조건이 악골 단면상의 높이, 폭 및 인지도에 미치는 영향 (The effect of different radiographic parameters on the height, width and visibility of cross-sectional image of mandible in spiral tomography)

  • 이태완;한원정;김은경
    • Imaging Science in Dentistry
    • /
    • 제33권1호
    • /
    • pp.43-49
    • /
    • 2003
  • Purpose : To evaluate the differences in bone height, bone width, and visibility of posterior spiral tomographic images according to various exposure directions, image layer thickness, and inclination of the mandibular inferior border. Materials and Methods: Six partially and completely edentulous dry mandibles were radiographed using Scanora spiral tomography. Spiral tomography was performed at different exposure directions (dentotangential and maxillotangential projection), image layer thicknesses (2 mm, 4 mm and 8 mm), and at various inclinations to the mandibular border (+ 100, 00 and -10°). The bone height and width was measured using selected tomographic images. The visibility of mandibular canal, crestal bone, and buccal and lingual surfaces were graded as 0, 1, or 2. Results : The bone width at the maxillo-tangential projection was wider than at the dento-tangential projection (p < 0.05). The visibility of buccal and lingual surface at the maxillo-tangential projection was higher than at the dento-tangential projection (p<0.05). Thinner image layer thicknesses resulted in greater visibility of buccal and lingual surfaces (p < 0.05). Bone height was greatest in the -10° group, and at the same time the bone width of the same group was the narrowest (p < 0.05). The visibility of alveolar crest and buccal surface of the + 10° group was the highest, while the visibility of the mandibular canal was greatest in the 00 group. Conclusion: When spiral tomography is performed at the mandibular posterior portion for visualization prior to implant surgery, it is important that the inferior border of mandible be positioned as parallel as possible to the floor. A greater improvement of visibility can be achieved by maintaining a thin image layer thickness when performing spiral tomography.

  • PDF

Assessing the anion type effect on the hydro-mechanical properties of smectite from macro and micro-structure aspects

  • Goodarzi, Amir R.;Akbari, Hamid R.
    • Geomechanics and Engineering
    • /
    • 제7권2호
    • /
    • pp.183-200
    • /
    • 2014
  • The expansivity of clayey soils is a complicated phenomenon which may affect the stability of geotechnical structures and geo-environmental projects. In all common factors for the monitoring of soil expansion, less attention is given to anion type of pore space solutions. Therefore, this paper is concerned with the impact of various concentrations of different inorganic salts including NaCl, $Na_2SO_4$, and $Na_2CO_3$ on the macro and microstructure behavior of the expandable smectite clay. Comparison of the responses of the smectite/NaCl and smectite/$Na_2SO_4$ mixtures indicates that the effect of anion valance on the soil engineering properties is not very pronounced, regardless of the electrolyte concentration. However, at presence of carbonate as potential determining ions (PDIs) the swelling power increases up to 1.5 times compared to sulfate or chloride ions. The samples with $Na_2CO_3$ are also more deformable and show lower osmotic compressibility than the other mixtures. This demonstrates that the barrier performance of smectite greatly decreases in case of anions with the non-specific adsorption (e.g., $Cl^-$ and $SO{_4}^{2-}$) as the salinity of solution increases. Based on the results of the X-ray diffraction and sedimentation tests, the high soil volumetric changes upon exposure to carbonate is attributed to an increase in the repulsive forces between smectite basic unit layers due to the PDI effect of $CO{_3}^{2-}$ and increasing the pH level which enhance the buffering capacity of smectite. The study concluded that the nature of anion through its influence on the re-arrangement of soil microstructure and osmotic phenomena governs the hydro-mechanical parameters of expansive clays. It seems not coinciding with the double layer theory of the Gouy-Chapman double layer model.

MDCT 장치의 z-축 기하학적 선량효율에 관한 연구 (Research of z-axis geometric dose efficiency in multi-detector computed tomography)

  • 김유현;김문찬
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권3호
    • /
    • pp.167-175
    • /
    • 2006
  • 최근의 나선형 CT와 MDCT는 기존의 고식적 CT보다 X-선 조사시의 겹침 현상과 영상 재구성에 있어서의 보간삽입처리로 인해 보다 높은 선량을 환자에게 주게 되었다. MDCT와 나선형 CT장치가 보다 많은 의학적 정보를 제공하는 것에도 불구하고 환자가 받는 방사선 노출은 기존의 고식적 CT검사에 비해 $2{\sim}4$배 정도로 증가되고 있는 실정이므로, 그 잠재적 위험성을 아무리 강조해도 지나침이 없다. CT장치에서의 보다 많은 X-선에 관련된 자료들, 특히 선량효율적 디자인이나 X-선 조절 소프트웨어에 대한 자료들이 필요하다. 왜냐하면 CT장치의 디자인 요소는 임상적 진단에 있어서 환자선량을 성공적으로 줄일 수 있는 중요한 요소이기 때문이다. 이에 본 연구에서는 최근 급격히 확산되어 사용되고 있는 여러 단계의 MDCT의 z-축 선량효율을 측정하여 SDCT와 비교하였다. 그리고 MDCT에서 스캔 시 채택하는 focal spot size와 beam collimation, 검출기 조합 등을 비롯한 파라메터들의 변화에 따른 z-축 선량효율을 파악하여 다음과 같은 결과를 얻었다. 1. SDCT가 z-축 기하학적 선량효율이 가장 높았고, 4 슬라이스 MDCT가 가장 낮았다. MDCT 중에서는 small beam collimation 적용 시 64 MDCT가 기하학적 선량효율이 가장 높았고 16, 8, 4 슬라이스 MDCT 순이었으며, large beam collimation 적용 시에는 small focal spot에서는 8 MDCT가, large focal spot에서는 16 MDCT가 가장 높았다. 2. MDCT의 경우 large focal spot에 비해 small focal spot의 z-축 기하학적 선량효율이 최저 0.67%에서 최대 13.62%의 범위에서 높았다. 3. MDCT의 경우 small beam collimation에 비해 large beam collimation의 z-축 기하학적 선량효율이 $3.13{\sim}51.52%$의 범위에서 높았다. 4. 동일한 focal spot size와 beam collimation을 채택한 상태에서 detector combination 차이에 따른 z-축 기하학적 선량효율은 4 슬라이스 MDCT의 모든 경우와 8 슬라이스 MDCT의 large beam collimation에서 일정하였다. 하지만 8 슬라이스 MDCT의 small beam collimation과 16 슬라이스 MDCT에서는 z-축 기하학적 선량효율이 차이를 보였으며 변화의 일률성은 없었다. 5. 동일한 스캔 파라메터를 적용시 나선형 스캔과 고식적 스캔 모드의 z-축 기하학적 선량효율은 동일하였으며, pitch를 변화시키거나 영상재구성 시 슬라이스 두께와 간격을 변화시켜도 z-축 기하학적 선량효율은 변화가 없었다. 결론적으로, CT검사 시 환자가 받는 X-선 피폭선량을 줄이기 위해 연구자는 CT장치의 선량효율에 대해 각별히 주의하여야 하며, Z-축 선량효율성을 높이는 동시에 최적의 임상적 정보를 보존할 수 있는 스캔 파라메터를 선택하여야 한다.

  • PDF

A dose monitoring system for dental radiography

  • Lee, Chena;Lee, Sam-Sun;Kim, Jo-Eun;Symkhampha, Khanthaly;Lee, Woo-Jin;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul;Yeom, Heon-Young
    • Imaging Science in Dentistry
    • /
    • 제46권2호
    • /
    • pp.103-108
    • /
    • 2016
  • Purpose: The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. Materials and Methods: An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. Results: The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. Conclusion: A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose.