• 제목/요약/키워드: X-ray equipment

검색결과 313건 처리시간 0.031초

진단용 X선장치의 성능 실태 조사연구 (A Study on the Test of Efficiency of the Diagnostic X-ray Equipment according to Their Rectifications)

  • 선종률
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권2호
    • /
    • pp.44-48
    • /
    • 1997
  • For the efficient management of the diagnostic x-ray equipment, a nation-wide inspection of hospitals was performed by an inspection institute in Taejon in the first half of 1997. Among those hospitals inspected, 28 equipments(machines) which were over 500 mA were randomly selected according to their characteristics : 7 condenser type x-ray equipments, 7 three control phase of full wave rectification of type remote control x-ray equipments, 7 single phase of full wave rectification type for general radiography equipments, and 7 single phase of full wave rectification type of R/F equipments. We obtained the following results by conducting the experiment based on the efficiency of the equipments mentioned above. 1) When the equipments are analyzed, 2 out of 7 single phase of full wave rectification type of general radiography equipments(28.6%), 3 out of 7 single phase of full wave rectification type of R/F equipments(42.9%), 5 out of 7 three phase of full wave rectification type remote of control x-ray equipments(71.4%), and 4 out of 7 condenser type of x-ray equipments(57.1%) showed suitability. It proves the superiority of the three phase of full wave rectification type of remote control x-ray equipments. 2) From the overall analysis, only about 50% of the equipments(suitability of 14 out of 28) maintain the efficient management. Therefore, maintenance management of equipments is more necessary. If the efficiency of the x-ray equipment is uniformly maintained and managed to prevent the breakdown(trouble) beforehand especially through the continuous inspection of tube voltage, tube current, exposure time, and collimator, the financial loss and exposure dose to the patient, as well as the workers engaged in radiation, can be reduced for better medical service.

  • PDF

진단용 X선 기기의 선질 분석 (Radiation Quality Analysis of Diagnostic X-ray Equipment)

  • 김태곤;김영표;천민우;박용필
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 추계학술대회
    • /
    • pp.771-772
    • /
    • 2010
  • 환자의 진단에 유용하게 사용되고 있는 X선 장치는 X선을 인체에 조사할 때 나타나는 피폭이 큰 단점으로 지적되고 있으며 ICRP에서는 인체의 방사선 노출 허용량을 제한하고 있다. 이러한 피폭을 줄이기 위해 많은 연구 개발이 진행되고 있다. 본 연구에서는 X선의 발생 효율 증가 및 정밀한 출력 제어가 가능한 인버터 방식의 고전압 발생장치를 제작하였다. 또한 X선관에 인가되는 직류 고전압에 발생 가능한 리플을 최소화하기 위해 전파 정류방식을 적용하였으며, 이를 환자의 진단에 사용하기 위해 조사재현성 및 선질을 평가하였다.

  • PDF

촬영 및 투시용 X선 장치의 기본안전과 필수 성능에 관한 개별 기준규격의 동향 (The Tendency of Medical Electrical Equipment - IEC 60601-2-54: Particular Requirements for the Basic Safety and Essential Performance of X-ray Equipment for Radiography and Radioscopy)

  • 노영훈;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권4호
    • /
    • pp.331-336
    • /
    • 2015
  • 식품의약품안전처 고시 "의료기기의 전기 기계적 안전에 관한 공통기준규격"이 IEC 60601-1 [3판] 따라 개정되었고 IEC-60601-1의 개별규격인 IEC 60601-2-54 또한 촬영 및 투시용 X선 장치의 기본 안전과 필수 성능에 관한 개별 기준규격으로 고시화 될 예정이다. 따라서 개별 규격의 도입에 앞서 주요 요건을 소개하고자 이 기술보고서를 작성하였다. IEC 60601-2-54의 목적은 촬영 및 투시를 위한 의료용 전기기기(이하 ME 기기) 및 ME 시스템에 요구되는 기본 안전과 필수 성능 요구사항을 확보하려는 것이다. IEC 60601-2-54는 방사선 촬영 및 투시장치의 X선 고전압장치, X선 기계장치, 방사선 방어 등에 관한 내용이다. 의료기기의 전기 기계적 안전에 관한 공통기준규격, 의료기기의 전자파 안전에 관한 공통기준규격, 의료기기의 방사선안전에 관한 보조기준 규격이 본 규격에 적용되었다. IEC-60601-2-54가 고시화될 경우 촬영 및 투시용 X선 장치의 기본 안전과 필수 성능에 관한 이해를 넓히고 국내 의료기기 산업의 국제화에 일조할 것이라고 판단된다.

PC기반 치과 CT용 고전압 펄스 발생장치 개발 (Development of PC based High Voltage Generator for Dental CT)

  • 김학성;오준용;송상훈;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.580-582
    • /
    • 2008
  • The object of this paper is develope the PC based controlled high voltage power supply and studies 1.2kW(120kV, 10mA) pulse power X-ray generator possible to adapt fluoroscopy of Dental CT X-ray generator and industrial X-ray pulse power equipment. The developed pulse power X-ray generator consisted of mono-block tank include X-ray tube and high voltage X-ray power supply circuit and high voltage control unit with RS232C/422 communication port. The PC control program of pulse power X-ray generator uses LabVIEW, and the size of high voltage transformer and high voltage generator is minimized by high voltage high frequency inverter has 100kHz switching frequency. Also this paper shows result of X-ray tube voltage and tube current correspond to variable load.

  • PDF

응급의료체계와 스포츠손상에서 휴대용 X-ray 장치의 도입 필요성 (The Necessary of Portable X-ray Equipment for Emergency Medical Service System and Sports Injures)

  • 조동헌;구경완;조진만
    • 한국응급구조학회지
    • /
    • 제8권1호
    • /
    • pp.189-197
    • /
    • 2004
  • The fate of a emergency patient is decided upon the extent of first aid in one hour after accident. Suitable diagnosis and treatment can raise the possibility of patient's life and reduce the recuperation time. We surveys papers which were The Korean Society Of Sports Medicine(1993-2004 yeas 405papers)and The Korean Society Of Emergency Medicine (1990-2004 yeas 797 papers). This paper got the following results through analyses of problems in emergency medical service system and of injures from sports. First, portable X-RAY equipment is needed to apply it to emergency. Second, it should have small and light structure compared with old equipments and have high voltage generator unit for X-RAY using inverter. Third, it should be able to send the shot data that is digital detector type without film to doctors in emergency center.

  • PDF

체형변화에 적합한 X-선 검사대 일체형 Merchant 보조장비의 유용성 평가 (Usefulness Evaluation of Merchant Auxiliary Equipment of Body Type Changing Suitable for X-ray Table Integral Type)

  • 성열훈
    • 한국산학기술학회논문지
    • /
    • 제14권6호
    • /
    • pp.2773-2779
    • /
    • 2013
  • 본 연구에서는 인체의 대퇴부 두께에 따른 다양한 무릎뼈의 굴곡각도가 가능하고 사용이 편리한 새로운 보조기구를 개발하고 유용성을 평가하고자 하였다. 검사 대상자는 연구 목적에 동의하고 과거 무릎 관련 질병이 없는 정상인 중 넙다리 둘레가 얇은 A 그룹과 두꺼운 B 그룹을 선발하였다. 무릎뼈의 축방 영상을 획득하기 위해 무릎굴곡각도를 $5^{\circ}$씩 증가시켜 $35^{\circ}$, $45^{\circ}$, $55^{\circ}$로 설정하였으며, 각 각도별로 X-선 입사각도를 $40^{\circ}$, $50^{\circ}$, $60^{\circ}$로 변화시켜 9 개의 검사 조합으로 검사하였다. 그 결과, 사용이 편리하고 체형변화에 적응할 수 있도록 다양한 무릎관절 각도가 가능한 검사대 일체형 무릎뼈 방사선영상검사 보조장비를 개발하였다. 그리고 이 보조장비를 이용하여 A 그룹에서는 무릎굴곡 각도가 $45^{\circ}$에서 X-선 입사 각도가 $60^{\circ}$$50^{\circ}$ 그리고 B 그룹에서는 X-선 입사 각도가 $60^{\circ}$에서 무릎굴곡 각도가 $35^{\circ}$$45^{\circ}$에서 우수한 영상이 도출되었다. 향후 다양한 체형의 환자들의 검사에 매우 유용할 것으로 사료된다.

엑스선에 의한 반도체 소자의 방사선 손상 (Radiation Damage of Semiconductor Device by X-ray)

  • 김동성;홍현승;박혜민;김정호;주관식
    • Journal of Radiation Protection and Research
    • /
    • 제40권2호
    • /
    • pp.110-117
    • /
    • 2015
  • 최근 방사선을 이용한 반도체 검사장비 산업의 증가로 이에 대한 기술 연구 수요 또한 증가하고 있다. 반도체 검사장비는 저에너지 엑스선으로 최저 40 keV에서 최고 120 keV의 에너지 영역을 사용하고 있지만, 국내에서는 저에너지 엑스선이 주는 방사선 손상 연구가 미흡한 상황이다. 따라서 본 연구는 저에너지 엑스선을 이용하여 반도체 소자의 한 종류인 BJT (bipolor junction transistor)가 받는 방사선 손상에 관한 것이다. BJT는 NXP반도체사의 BC817-25(NPN type)를 사용하였으며, 엑스선 발생장치를 사용하여 엑스선을 조사하였다. BJT의 방사선 손상 여부는 엑스선 조사 전과 후에 전류 이득을 10으로 고정하고, 콜렉터 전류에 따른 콜렉터-이미터 전압을 측정하여 변화 정도를 분석하여 확인하였다. 엑스선 발생장치의 관전압은 40 kVp, 60 kVp, 80 kVp, 100 kVp, 120 kVp 등 다섯 가지로, 조사 시간은 60초, 120초, 180초, 360초, 540초 등 다섯 가지로 변수를 두었다. 실험 결과 BJT에서 저에너지 엑스선 즉, 120 keV 이하의 엑스선을 조사하여도 방사선 손상이 발생하는 것을 확인하였고, 특히 80 kVp에서 가장 큰 방사선 손상이 발생되었다. 이는 ELDRS (enhanced low dose rate sensitivity) 현상이 80 kVp을 기준으로 발생되는 것으로 판단된다. 본 연구의 결과는 저에너지 엑스선을 이용한 반도체 검사장비의 효율적인 선량관리와 엑스선 여과기의 연구 및 개발에 기여할 것으로 기대한다.

디지털 엑스선 기술과 응용 (Digital X-Ray Technology and Applications)

  • 정진우;강준태;김재우;박소라;이명래;송윤호
    • 전자통신동향분석
    • /
    • 제34권5호
    • /
    • pp.1-13
    • /
    • 2019
  • In modern times, X-ray imaging has become a necessary tool for early diagnosis, quality control, nondestructive testing, and security screening. X-ray imaging equipment generally comprises an X-ray generator and an image sensor. Most commercially available X-ray generators employ filament-thermionic electron-based X-ray tubes, thus demonstrating typical analog behavior, such as slow response and large stray X-rays. Furthermore, digital X-ray sources, which have been studied extensively using field electron emitters manufactured from nanometer-scale materials, provide fast and accurately controlled ultra-shot X-rays. This could usher in a new era of X-ray imaging in medical diagnosis and nondestructive inspections. Specifically, digital X-ray sources, with reduced X-ray dose, can significantly improve the temporal and spatial resolution of fluoroscopy and computed tomography. Recently, digital X-ray tube technologies based on carbon nanotubes, developed by Electronics and Telecommunications Research Institute, have been transferred to several companies and commercialized for dental imaging for the first time.

진단용엑스선촬영장치의 간접 선량 계산법 개발 (Development of Indirect Dosimetry by Calculation Method in the Diagnostic X-ray Equipment)

  • 김정수;김성환;전민철;주원하;정민규;김미정;이승열;이태희;성열훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.587-594
    • /
    • 2018
  • The purpose of this study was to develop the indirect dosimetry by calculation (IDC) method for diagnostic X-ray equipment. The experiments were performed with inverter type X-ray tubes: Toshiba (E7252X, Japan) and Varian (RAD-14, USA). For the development method, we first applied the standard quality of X-ray beam shown in the TRS457 document, and second, to produce the constants of trendline for the IDC, the total filtration on X-ray beam was subdivided. Third, in order to increase the precision, the energy region was divided into the high energy region and the low energy region and developed by the IDC. In order to verify the IDC, mean dose (mR) values were measured for three Toshiba X-ray tubes and three Varian X-ray tubes at clinical medical institutions and then compared with the IDC on the 2013. As a result, compared with the previous study, the accuracy of the IDC of this study were improved by 2.71% and 9.91% in Toshiba and Varian X-ray tubes, respectively.