• 제목/요약/키워드: X-ray apparatus

검색결과 102건 처리시간 0.027초

절삭가공시 잔류응력에 관한 연구 (A Study on Residual stress at Cutting work)

  • 주호윤
    • 한국생산제조학회지
    • /
    • 제6권3호
    • /
    • pp.111-117
    • /
    • 1997
  • The sudden-stop apparatus is made to measure the residual stress of the infinitesimal area at the turning work surface by using the X-ray stress apparatus. This study is trued to make the cutting work the instantaneous stopping state in the normal working state. The behaviour of work material near the tool is estimated. The estimation method is that the distribution of residual stress can be also measured. The object is to clarify and control the mechanism to leave the adequate stress of the finishing surface. It's beginning is due to observe the occurrence state of the residual stress at the cutting work. The result obtained by this study is as follows. The chips are not separated from the work materials at all the cutting experiments of built-up edges or the shearing areas etc. which can be precisely observed by using the sudden-stop apparatus. The strain of movable system which can be seen at the part of working layer means the size of strain. This experiment proves that the working strain should be lessened to make the size of strain control the residual stress happened at the cutting surface.

  • PDF

RF magnetron 스파터링법으로 제작한 TiNx 박막의 XPS 분석 (XPS Analysis of TiNx Thin Films by RF Magnetron Sputtering)

  • 박문찬;오정홍;황보창권
    • 한국안광학회지
    • /
    • 제3권1호
    • /
    • pp.115-120
    • /
    • 1998
  • RF(radio-frequency) magnetron 스퍼터링 장치에 질소가스와 아르곤가스를 동시에 주입하면서 Ti 타켓을 스퍼터링하여 $TiN_x$ 박막을 유리기판위에 제작하였다. 박막제작시 RF power supply 출력을 240W로, 증착기 내부의 온도는 $200^{\circ}C$를 유지하였다. $TiN_x$ 박막은 알곤 가스를 20sccm으로 고정시킨 상태에서 질소를 3sccm부터 9sccm까지 변화시켜가며 증착시켰다. 이때 박막의 화학적 조성과 성분비를 분석하기 위하여 XPS를 사용하였다.

  • PDF

ALVIM Phantom을 이용한 화질관리 (Image Quality Management Using ALVIM Phantom)

  • 임득춘;동경래;박용순;김창복;류영환
    • 대한디지털의료영상학회논문지
    • /
    • 제11권2호
    • /
    • pp.63-68
    • /
    • 2009
  • Among various physical or subjective assessments of the quality of X-ray images, physical assessments can be quantitative but they are eventually judged by the view of observers thus subjective assessments including the aspect of observers are required. The changes in the ability to detect lesions caused by changes in the thickness of acrylic plates were tested with the ROC interpretation method that has taken into consideration, all the features of physical assessments as well as observers' ability to observe and mental stages and even surrounding environments using an Alvim phantom and the result indicated that as the thickness of acrylic plates increased, the amount of noises occurred increased compared to signals and thus the ability to detect signals as well as the sensitivity that is an ability to signals accurately and the ability to distinguish noises from signals thus it is considered that more efforts of radiologic technologists will be required to detect small lesions of fat patients with diagnostic X-ray generating apparatus.

  • PDF

Linear Accelerator를 이용한 Stereotactic Radiosurgery 방법 (A Method of Stereotactic Radiosurgery Using A Linear Accelerator)

  • 나수경;박재일
    • 대한방사선치료학회지
    • /
    • 제6권1호
    • /
    • pp.146-153
    • /
    • 1994
  • A modified irradiation technique utilizing a linear accelerator for radiation surgery within the brain was performed in 41 cases of patients with anteriovenous malformation(AVM), astrocytoma, meningioma. etc. The treatment planning and dosimetry of small field for stereotactic radiosurgery with 10 MV X-ray isocentically mounted linear accelerator will be presented dose with field size, the central axis persent depth dose and the combined moving beam dose distribution. The three dimensional dose planning of stereotactic focusing irradiation on small size tumor region was perfomed with dose planning computer system(Therac 2300) and was verified with film dosimetry. The more the number of strip and the wider the angle of arc rotation, the larger were the dose delivered on tumor and the less the dose to surrounding the normal tissues. In this study, the using machine and method was as fellowing. 1) Apparatus : NELAC-1018 10MV X-ray 2) Strip No. : Select the 5-7 strips 3) Cone and field size are from $1{\times}1cm^2$ to $3.5{\times}3.5cm^2$, and special circular cone designed for the purpose of minimized the risk to normal tissue and those size are $0.7{\~}3.6cm{\phi}$.

  • PDF

모래 입자의 형상과 내부마찰각의 상관관계에 관한 연구 (Shear Resistance of Sandy Soils Depending on Particle Shape)

  • 서형석;조유민;윤태섭;김광염
    • 한국지반공학회논문집
    • /
    • 제32권6호
    • /
    • pp.41-48
    • /
    • 2016
  • 본 연구에서는 영상처리 기법을 이용해 총 9개의 모래 시료의 형상을 정량화하여 전단강도와의 상관관계를 분석하였다. 분석 시료는 6개의 자연모래 시료와 3개의 부순모래 시료이며 이를 고해상도 3차원 X-ray CT 촬영하여 그로부터 개별 입자 영상을 분리하고 구형도(Sphericity) 및 이완도(Elongation)와 같은 형상 계수를 통해 모래 시편의 형상을 정량화 하였다. 또한 시료의 상대밀도를 다르게 조성하여 직접전단시험을 수행해 첨두내부마찰각(Peak friction angle)과 극한내부마찰각(Critical state friction angle)을 획득하였다. 시료의 구형도가 감소하고 이완도가 증가할수록, 첨두내부마찰각과 극한내부마찰각은 유사한 기울기를 보이며 증가함을 확인하였으며 두 내부마찰각 사이 절댓값 차이는 입자 형상보다는 상대밀도 차이로부터 기인함을 확인하였다.

$Mg_2NiH_x$ 수소저장합금의 미세결정구조 및 수소화 특성평가 (Evaluations of Microstructure and Hydrogenation Properties on $Mg_2NiH_x$)

  • 석송;신경;권순용;어순철;이영근;홍태환
    • 한국수소및신에너지학회논문집
    • /
    • 제16권3호
    • /
    • pp.238-243
    • /
    • 2005
  • Mg and Mg-based alloys are most important hydrogen storage materials. It is a lightweight and low-cost materials with high hydrogen storage capacity. However, the formation of hydride at high temperature, the deterioration effect, the hydriding and dehydriding kinetics are bad factor for application. In this study, Mg and Ni have been produced by hydrogen induced mechanical alloying(HIMA) process. The raw materials, Mg(purity 99.9%) chip and Ni(purity 99.95%) chip was prepared by using a planetary ball mill apparatus(FRITSCH pulverisette 5). The balls to chips mass ratio(BCR) are 30:1. The hydrogen pressure induced 2.0MPa and milling times were 12, 24, 48, 72, 96 hours with a rotating speed of 200rpm. X-ray diffraction(XRD) analysis was made to characterize the crystallite size and misfit strain. The crystallite size measured by laser particle size analysis(PSA). Microstructure changes were investigated by scanning electron microscopy(SEM) and the transmission electron microscopy(TEM). The hydrogen storage properties were evaluated by using an Sivert's type automatic pressure-composition-therm(PCT) apparatus.

스프링클러 구리배관의 공식 파손 억제 (Inhibition of Pitting Corrosion Failure of Copper Tubes in Wet Sprinkler Systems)

  • 서상희;서영준;이종혁;권혁상
    • Corrosion Science and Technology
    • /
    • 제19권2호
    • /
    • pp.89-99
    • /
    • 2020
  • The inhibition of pitting corrosion failure of copper sprinkler tubes in wet sprinkler systems was studied. First, an apparatus and technology for removing air in the sprinkler tubes by vacuum pumping and then filling the tubes with water were developed. Using this apparatus and technology, three methods for inhibiting the pitting corrosion of the copper sprinkler tubes installed in several apartment complexes were tested. The first one was filling the sprinkler tubes with water bubbled by high-pressure nitrogen gas to reduce the dissolved oxygen concentration to lower than 2 ppm. In the second method, the dissolved oxygen concentration of water was further reduced to lower than 0.01 ppm by sodium sulfite. In the third method, the sprinkler tubes were filled with benzotriazole (BTAH) dissolved in water. The third method was the most effective, reducing the failure frequency of the sprinkler tubes due to pitting corrosion by more than 80%. X-ray photoelectron spectroscopy analyses confirmed that a Cu-BTA layer was well coated on the inside surface of the corrosion pit, protecting it from corrosion. A potentiodynamic polarization test showed that BTAH should be very effective in reducing the corrosion rate of copper in the acidic environment of the corrosion pit.

RF magnetron 스파터링법으로 제작한 TiNx 박막의 면저항분석 (Sheet Reisistance Analysis of TiNx Thin Film by RF Magnetron Sputtering)

  • 박문찬;오정홍;김남영;황보창권
    • 한국안광학회지
    • /
    • 제4권1호
    • /
    • pp.21-25
    • /
    • 1999
  • RF(radio-frequency) magnetron 스퍼터링 장치에 질소가스와 아르곤가스를 동시에 주입하면서 Ti 타켓을 스퍼터링하여 TiN, 박막을 유리기판위에 제작하였다. 박막제작시 RF power supply 출력은 240W로, 증착기 내부의 온도는 $200^{\circ}C$를 유지하였다. TiN, 박막은 알곤 가스를 20sccm으로 고정시킨 상태에서 질소를 3sccm부터 9secm까지 변화시켜가며 증착시켰다. 이때 박막의 면저항과 화학적 조성과의 관계를 분석하기 위하여 XPS depth profiling과 4점 탐침법을 사용하였다.

  • PDF

X선 진단장치의 고압정류방식이 대조도 향상에 미치는 영향 (Effects of Contrast Improvement on High Voltage Rectification Type of X-ray Diagnostic Apparatus)

  • 이후민;윤준;김현주
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권3호
    • /
    • pp.187-193
    • /
    • 2014
  • 본 연구는 X선 진단장치의 고압정류방식이 그리드 성능을 측정하는 선택도(selectivity)와 대조도 향상능력(contrast improvement ability : K factor)에 미치는 영향을 분석하고자 산란선 함유율을 측정하였다. 정류방식이 서로 다른 X선발생장치를 대상으로 각 장치의 관전압과, 관전류량을 측정하여 출력선량의 정확도를 측정 및 교정한 후 각 장치별 노출조건을 동일하게 설정하고 형광량계를 이용하여 아크릴을 투과한 X선의 산란선 함유율을 측정하였다. Grid 미사용 시 피사체를 투과한 X선의 산란선 함유율 측정 결과는 단상정류방식장치에서 가장 낮은 함유율(34.158%)이 측정되었고, 인버터 정류방식(37.043%)과 삼상24피크 정류방식(37.447%)은 산란선 함유율이 증가하였다. 각 장치들의 산란선 함유율 차이는 최저 0.404%에서 최고 3.289%의 차이를 보였다. 8:1 Gird 사용 시 피사체를 투과한 X선의 산란선 함유율을 측정한 결과는 단상정류방식장치에서 가장 낮은 함유율(18.258%)로 측정되었고, 인버터정류방식(25.502%)과 삼상24피크정류방식에서 산란선 함유율(24.217%)이 증가하였다. 그리드 선택도에 따라 단상정류방식과 정전압(인버터와 삼상24피크)정류방식에서 산란선함유율의 차이는 최저 1.285%에서 최고 7.244%의 차이를 보였다. 통계분석 결과 단상정류방식 및 정전압정류방식에서 대조도 향상계수(K factor)에서도 유의한 차이를 보였다. 결론적으로 그리드 선택도와 대조도 향상계수는 정전압정류방식보다는 단상전파방식에서 모두 증가하여 그리드의 사용으로 선택도 향상과 대조도의 개선효과가 증가함을 알 수 있었다.

ARAS용 TiNx 광학박막의 설계제작과 특성연구 (The design and characteristic of the TiNx optical film for ARAS coating)

  • 박문찬;정부영;황보창권
    • 한국안광학회지
    • /
    • 제6권2호
    • /
    • pp.31-35
    • /
    • 2001
  • $TiN_xW_y$ 전도박막층으로 무반사, 무정전 광학박막을 Essential Macleod 프로그램을 이용하여 설계한 결과 [공가 ${\mid}TiN_xW_y{\mid}SiO_2{\mid}$ 유리]층은 단 두층코팅막으로 가시광선 파장영역 (450~700 nm)에서 넓게 AR 코팅이 되었다. RF magnetron 스퍼터링 장치에 질소가스와 아르곤가스를 동시에 주입하면서 Ti 타켓을 스퍼터링하여 $TiN_x$ 광학박막을 7 nm에서 10 nm의 두께로 유리기판 위에 제작하였다. 이 때 박막의 화학적 조성과 성분비를 분석하기 위해 XPS를 사용하였고, 박막의 면저항과 화화적 조성과의 관계를 분석하기 위하여 XPS depth profiling과 4점탐침법을 사용하였다.

  • PDF