• 제목/요약/키워드: X-ray Imaging System

검색결과 290건 처리시간 0.024초

Rotating-Gantry-Based X-Ray Micro-Tomography System with the Sliding Mechanism Capable of Zoom-In Imaging

  • Cho, Min-Hyoung;Lee, Dong-Hun;Han, Byung-Hee;Lee, Soo-Yeol
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권2호
    • /
    • pp.107-113
    • /
    • 2008
  • We introduce a rotating-gantry-based x-ray micro-tomography system to be used for small animal imaging studies. It has the zoom-in imaging capability for high resolution imaging of a local region inside the animal subject without any contrast anomalies arising from truncation of the projection data. With the sliding mechanism mounted on the rotating gantry holding the x-ray source and the x-ray detector, we can control the magnification ratio of the x-ray projection data. By combining the projection data from the large field of view (FOV) scan of the whole animal subject and the projection data from the small FOV scan of the region of interest, we can obtain artifact-free zoomed-in images of the region of interest. For the acquisition of x-ray projection data, we use a $1248{\times}1248$ flat-panel x-ray detector with the pixel pitch of 100 mm. It has been experimentally found that the developed system has the spatial resolution of up to 121p/mm when the highest magnification ratio of 5:1 is applied to the zoom-in imaging. We present some in vivo rat femur images to demonstrate utility of the developed system for small animal imaging.

X선 3차원 영상 시스템에서의 영상 왜곡 및 영상 좌표계 보정 (Correction of Image Distortion and Coordinate Calibration of the x-ray three dimensional imaging system)

  • 노영준;김재완;조형석;전형조;김형철;주효남
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.413-413
    • /
    • 2000
  • In this paper, we propose a series of calibrations f3r the x-ray three dimensional imaging system. In the developed x-ray system, a three dimensional inner and outer shape of an object can be reconstructed out of two dimensional transmitted x-ray image set, which are acquired by projecting x-ray to the object from different views. To achieve this, a reconstruction algorithm which estimates and updates the three dimensional volume from x-ray images is developed. The algorithm is named as uniform and simultaneous algebraic reconstruction technique(USART) which is an iterative method estimating a 3D volume based on its projected images. In this method, it is assumed that the imaging conditions that are the relative positions between the x-ray sources, object and the image planes are blown. Practically it is not easy to know the three dimensional coordinate of the components of the system, since the x-ray is not visible and the image distortions are present due to the optical components in the system. In this paper, methods of correcting image distortions are present firstly. Then the coordinates of the x-ray systems are calibrated from the x-ray images of the grid pattern. Some experimental results on these calibrations are present and discussed.

  • PDF

이중 에너지 검출기를 이용한 영상 시스템 (Image System Using Dual Energy Detector)

  • 여화연
    • 한국산학기술학회논문지
    • /
    • 제11권9호
    • /
    • pp.3517-3523
    • /
    • 2010
  • 본 논문은 이중 에너지 DR(Digital Radiography) 방식 중, 단일 조사 X-선(single shot X-ray exposure) 장치와 이중 모드 검출기 모듈 (Low Energy Detector & High Energy Detector)을 이용한 이중 X-선 이미징이 가능한 검출기 모듈에 관한 연구이다. 상용 BIS(baggage inspection system)에서 사용되고 있는 X-선 발생장치의 스펙트럼과 이중 모드 검출기에 대한 특징 및 방사선적 특성을 분석하여 새롭게 제안 할 검출기 모듈의 최적 설계 방향을 기술하고 상용화된 용화된 LED 및 HED 검출기와 새롭게 제안 한 검출기 모듈에 대해 전기적, 광학적, 방사선적 특성 실험을 실시하여, 새롭게 제안된 검출기 모듈이 BIS 용도로 사용 가능함을 증명하였다. 새롭게 제안 된 검출기 모듈이 적용된 BIS에 대해, 기본 특성 실험에 대한 X-선 영상을 획득하여 실험 및 분석을 실시하였다.

소형 동물의 생체 촬영을 위한 고해상도 Micro-CT 시스템의 개발 (Development of High Resolution Micro-CT System for In Vivo Small Animal Imaging)

  • 박정진;이수열;조민형
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.95-101
    • /
    • 2007
  • Recently, small-animal imaging technology has been rapidly developed for longitudinal screening of laboratory animals such as mice and rats. One of newly developed imaging modalities for small animals is an x-ray micro-CT (computed tomography). We have developed two types of x-ray micro-CT systems for small animal imaging. Both systems use flat-panel x-ray detectors and micro-focus x-ray sources to obtain high spatial resolution of $10{\mu}m$. In spite of the relatively large field-of-view (FOV) of flat-panel detectors, the spatial resolution in the whole-body imaging of rats should be sacrificed down to the order of $100{\mu}m$ due to the limited number of x-ray detector pixels. Though the spatial resolution of cone-beam CTs can be improved by moving an object toward an x-ray source, the FOV should be reduced and the object size is also limited. To overcome the limitation of the object size and resolution, we introduce zoom-in micro-tomography for high-resolution imaging of a local region-of-interest (ROI) inside a large object. For zoom-in imaging, we use two kinds of projection data in combination, one from a full FOV scan of the whole object and the other from a limited FOV scan of the ROI. Both of our micro-CT systems have zoom-in micro-tomography capability. One of both is a micro-CT system with a fixed gantry mounted with an x-ray source and a detector. An imaged object is laid on a rotating table between a source and a detector. The other micro-CT system has a rotating gantry with a fixed object table, which makes whole scans without rotating an object. In this paper, we report the results of in vivo small animal study using the developed micro-CTs.

캐비닛 엑스선 검색장비 이미지품질평가 고도화 방안 연구 (Improving Imaging Quality Assessment of Cabinet X-Ray Security Systems)

  • 윤연아;정진형;김용수
    • 품질경영학회지
    • /
    • 제49권1호
    • /
    • pp.47-60
    • /
    • 2021
  • Purpose: This study proposes methods and procedures for evaluating imaging security systems quality of cabinet x-ray screening system to enhance performance certification technology. Also, conducted a comparative analysis of the literature of test-kit for imaging security quality evaluation. Methods: Comparative analysis of the test-kits and related documents for image quality assessment of cabinet x-ray screening equipment. This allows assessment items were selected and the methods for each assessment item were proposed. In addition, the configuration method of the assessment team was established by applying the technology readiness assessment(TRA). Results: Four of the assessment items were selected when estimate image quality by a comparative analysis of literature. For each assessment item, the evaluation method and minimum level of availability were determined. Finally, this paper proposes an imaging quality assessment of cabinet X-ray imaging security systems. Conclusion: Development of imaging security systems evaluation procedures for cabinet X-ray screening systems can be help improve performance certification of aviation security equipment.

대면적 X-ray 검출기를 위한 분할 구동 시스템 (Seperate Driving System For Large Area X-ray Detector In Radiology)

  • 이동길;박지군;김대환;남상희;안상호;박효덕
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.388-391
    • /
    • 2003
  • The properties of these detectors can be controlled by electronics and exposure conditions. Flat-panel detectors for digital diagnostic imaging convert incident x-ray images to charge images. Flat panel detectors gain more interest real time medical x-ray imaging. Active area of flat panel detector is $14{\times}17$ inch. Detector is based on a $2560{\times}3072$ away of photoconductor and TFT pixels. X-ray conversion layer is deposited upper TFT array flat panel with a 500m by thermal deposition technology. Thickness uniformity of this layer is made of thickness control technology(5%) of thermal deposition system. Each $139m{\times}139m$ pixel is made of thin film transistor technology, a storage capacitor and charge collection electrode having geometrical fill factor of 86%. Using the separate driving system of two dimensional mosaic modules for large area, that is able to 4.2 second per frame. Imaging performance is suited for digital radiography imaging substitute by conventional radiography film system..

  • PDF

의료영상장치의 전자파 안전에 대한 연구 (A Study on the Safety of Electromagnetic Wave of Medical Imaging System)

  • 선종률;이원정;임재동
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2010년도 추계학술대회
    • /
    • pp.103-112
    • /
    • 2010
  • This study was done to provide basic data on the safety of professionals in medical imaging system by measuring the electromagnetic waves generated in the medical imaging system being used in medical organization. The studied medical imaging systems were general X-ray system, computed tomography(CT), ultrasonographic system, magnetic resonance imaging(MRI), PET-CT and fluoroscopic system, and through these devices, electric field and magnetic field were measured and analyzed. As a result of the analysis, the measured values classified by the medical organizations were not much significant, but in the measurement by the medical imaging systems, there were high hazard elements in the sequential order of electric field PET-CT($17.7{\pm}22.9$)v/m, CT($10.3{\pm}8.7$)v/m, general X-ray system ($8.8{\pm}8.8$)v/m, magnetic field general X-ray system($5.06{\pm}8.26$)mG, CT($2.71{\pm}4.53$)mG and PET-CT($0.74{\pm}0.34$)mG, the systems that adopted X-ray as main ray source, and the more aged the medical imaging systems, the greater the effects of electro-magnetic waves($10.6{\pm}15.93v/m$ for 5 years or more, $6.14{\pm}5.60v/m$ for 5 years or less). The effects of electromagnetic waves on medical imaging systems or facilities were not much when the notification of ministry of knowledge economy is considered, but in the overall perspective considering all the equipments and facility of the medical organization, such effects were significant. It is determined that sustainable safety managements of electric field and magnetic field must be done during process from medical imaging system installation to maintenance to rule out such factors.

  • PDF

의료영상장치의 전자파 안전에 대한 연구 (A Study on the Safety of Electromagnetic Wave of Medical Imaging System)

  • 선종률;이원정;임재동
    • 대한안전경영과학회지
    • /
    • 제12권4호
    • /
    • pp.67-72
    • /
    • 2010
  • This study was done to provide basic data on the safety of professionals in medical imaging system by measuring the electromagnetic waves generated in the medical imaging system being used in medical organization. The studied medical imaging systems were general X-ray system, computed tomography(CT), ultrasonographic(USG) system, magnetic resonance imaging(MRI), PET-CT and fluoroscopic(R/F) system, and through these devices, electric field and magnetic field were measured and analyzed. As a result of the analysis, the measured values classified by the medical organizations were not much significant, but in the measurement by the medical imaging systems, there were high hazard elements in the sequential order of electric field PET-CT($17.7{\pm}22.9$)v/m, CT($10.3{\pm}8.7$)v/m, general X-ray system($8.8{\pm}8.8$)v/m, magnetic field general X-ray system($5.06{\pm}8.26$)mG, CT($2.71{\pm}4.53$)mG and PET-CT($0.74{\pm}0.34$)mG, the systems that adopted X-ray as main ray source, and the more aged the medical imaging systems, the greater the effects of electro-magnetic waves($10.6{\pm}15.93v/m$ for 5 years or more, $6.14{\pm}5.60v/m$ for 5 years or less). The effects of electromagnetic waves on medical imaging systems or facilities were not much when the notification of ministry of knowledge economy is considered, but in the overall perspective considering all the equipments and facility of the medical organization, such effects were significant. It is determined that sustainable safety managements of electric field and magnetic field must be done during process from medical imaging system installation to maintenance to rule out such factors.

방사광 위상차 현미경을 이용한 생체조직의 미세구조 영상 (Synchrotron Radiation Imaging of Tissues Using Phase Contrast Technique)

  • 강보선;이동열;김기홍
    • 한국방사선학회논문지
    • /
    • 제2권2호
    • /
    • pp.23-30
    • /
    • 2008
  • 방사광 X-선 현미경은 임상실험에 유용한 도구로 높은 배율과 고 해상도로 동물 장기조직 시료의 세부 구조를 관찰할 수 있다. X-선 영상은 위상 대조도 메커니즘으로 설명할 수 있다. 우리는 쥐의 꼬리, 신경 및 허파의 in-vivo 및 in-vitro위상 대조도 영상을 8 KeV mono 빔으로부터 10배 현미경대물렌즈와 CCD 카메라를 이용하여 얻었다. 기존의 흡수 X-선 영상 보다 SR 영상이 세밀한 구조의 높은 분해능 영상을 볼 수 있었다. SR 영상은 생물학, 재료 및 임상 연구에 무한한 가능성을 가지고 있다.

  • PDF

A Volume Reconstruction Algorithm and a Coordinate Calibration of an X-ray Three Dimensional Imaging System

  • Roh, Young-Jun;Cho, Hyung-Suck;Jeon, Hyoung-Jo;Kim, Hyeong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.63.3-63
    • /
    • 2001
  • Inspection and shape measurement of three-dimensional objects are widely needed in industries for quality monitoring and control. In this paper, we propose a three dimensional volume reconstruction method, which is an iterative method and as uniform and simulated algebraic reconstruction technique (USART). In this method, two or more x-ray images projected from different views are needed, and also the geometry of the imaging system need to be a priori identified well. That is to say, the relative locations between the x-ray source, imaging plane and the object should be determined exactly by calibration. To achieve this, we propose a series of coordinate calibration methods of the x-ray imaging system using grid pattern images. Some experimental results of these calibrations is presented and discussed in detail ...

  • PDF